42.8 watts with 0.36PF is inverter idle draw. Currently, Idle draw supply is sourced from grid, not batteries or solar. If you disconnect the grid, idle draw will come from batteries and solar (these inverters do DC+DC mixing). You need to disconnect grid/mains to make sure that Inverter own power is not coming from Grid. Also SL4 setting will not help you since SL1-4 setting is for charge controller with RTC clock whereas your concern is with device/inverter own power draw. This is normal in all tranformer based inverters. 40watts consumption on aluminium based and 25-30 watts on copper based. Gamma 3350 also consumes 40 watts. If you are worried about 0.36 PF, just power on some load and PF will improve. Again this is by design on how transformer work. Currently, only Ashapower and UTL Gamma is the one which doesn't draw its own power consumption from Grid. Ashapower is far superior in all aspects but not value for money, especially if you have sized your solution appropriately and keep the grid disconnected. If you want some automation, just use a smart switch/relay to control Mains supply to inverter. My normal 12v 900va inverter idle draw is 24 watts. So you can relate that 42 watts is ok. I hope it helps.
Saggu Sahib. Thank you so much. It is nice help and describe in details. I have installed smart MCB and supplying main grid only two hours per day. Company said this product software is not updated. In ideal condition transformer should be get switched off.
From my view point your inverter is fully normal it will consume some current to run itself when you will install solar panels on it you will not feel the pinch of commercial supply. I am using 48 v model without adding gride supply in fact mains are switched off since second day of installation. Your decision of buying this inverter is correct and results will be seen after installing panels. Tks
You are right sir. Company accepted that this need to update software. After 45 mins charging transformer should shutdown but as of now it's on for 24 hours.
Hi Desi ji, Can you share any proof or written email from the company in which the Company accepted that need to update the software in inverter. I think you are miss guided or miss guide others.
Hi Vijay ji, You are right. It is the no load power consumption of the inverter during Grid Mode. All inverters in the market are coming with that loss. But EAPRO launch new series in which these losses are saved through technology. The EAPRO new series inverters are Power Saver series
@@anuragpandey5101 Yes, I have recorded the call details. I'm not misguiding. I don't have any business in the same. Call me 9041398230. will share call recordings where the company person is asking to update the software. Even though they agreed to send the product for updating, they stopped picking up my calls and I even stopped follow-ups.
@@anuragpandey5101 Right they asked me to share the serial number then came to me and asked to update the software. Sir, I'm not misguiding. even I said at the start of the video that the product is good but only this is the main problem.
Explore EAPRO new series of inverters Power Saver Series which will solve your problem Trust me no inverter manufacturers will help you to minimise those losses.
@@ajaykumarpilkhuwa chat.whatsapp.com/INEW6iGl96gCAOJVGzcsFJ Ye group join karo. Sab ans milega..mere pass utl nahi hai.. but log ashapwer acha Bata rahe hai
Sehi h sir m bi lyny ki soch he reha ta ...7-03-2024 pr ab nhi luga jb service me hi problem h to .. M haryana sy hu district Palwal 20k rs do or problem ho TB Rona kya fayda esy
@@rohansarode apke pass local eapro ka authorised dealer hai to eapro ki power saving searies le lo..but ye dekh lena eapro ka service hai ya nahi.. online mat lena local market main Jake lena.
This model is over hyped..... It has software program flaw... Overcast for few minutes, it will supply power from main instead of batteries... Where as Smarten will supply power from batteries after solar panel.. Only shift to main after discharging of batteries to a pre-selected value.... smart logic board or software program is far better with Smarten MPPT inverter. EAPRO has higher power rating, you can install more solar panel... But what's the use if it switch to main in daytime whenever little cloud. Of course you can manually disconnect the main... but why to intervene when one can design better software program.
सर् sl-4 की सेटिंग के बारे में डिटेल्स से बताइए क्योंकि sl 4 में सेट करने पर साथ ही ग्रिड से चार्जिंग ऑन होने पर और लोड डालने पर यह लोड को ग्रिड में शिफ्ट हो जाता है न कि बैटरी पर हालांकि चार्जिंग सोलर से ही करता है। और सुबह 6-10 (सेटिंग के अनुसार डिसएबल है)तक मे यह सारा लोड ग्रिड पर ही शिफ्ट करता है । मेरे पास 48 बोल्ट का सेट अप है 2200 वाट पैनल के साथ मे।
42w 24v inviter ok (mara Microteck12v non solar inviter 15h charging hota haa charging time 200w sa 280w normal full charging ki bad 30w sa 50w lata haa all time ) no problem 😀😀😀
सर हमारे पास लुमिनस का 2350 मॉडल नंबर इनवर्टर है सोलर इन्वर्टर वह इनवर्टर 60% बैटरी रहने के बाद इनवर्टर ऑफ हो जाता है कोई लोड नहीं चलता है इनवर्टर में 60% बैटरी बताता है उसके लिए सॉल्यूशन बताइए आपका सब चैनल सब्सक्राइब कर लिया है
@@kamtamaurya5180 app apna number de. Ya WhatsApp kare pls. 9041398230 Mai apko ik solar wale group mai add karuga. Mai to itna janta nahi ho but apka help jarur ki jayegi.
@@sbbjbilarabilara4736 panel ka voc kya hai.. Max input 110v hai.6x36=216 possible nahi hai .mene apne farm mai statcon ka lagaya hai jo jain irrigation ka system hai. Inverter ka input range 230v hai. And 7 panel series mai lagaye hai.
Agree karta hu..ye bat mere ko Pata nahi thi and eapro walo ne batayi. Seller ki mistake hai..kuch paisa ke liye apna product none service area mai bhej diya.
@@ankitchauhan1162 Bhai Maine India mart se liya tha yehi pata karna hai ki service hai ya nahi kanpur me kyu ki eapro ke customer care Wale reply Tak nahi kar rahe hai bahut bekar company hai kisi ko lene ke liye mat bolna
Delhi wale log bhi rote hai. waha bhi service nahi de pa rahe.. After sale service to achi hona hi chahiye. electronic cheese hai kabhi bi problem aa sakti hai.
Dear Desi ji, Can you share any proof of claim of software update. It is EAPRO new series of inverters Power Saver Series which have such power saving features.
Sir koi saman kitana achha kyo na ho lene se pahale service centre jarur check kar le. Dusari baat sir es inverter par aap 3500watts panel ke sath 2battery our add kar le sayad aapko grid ki jarurat hi nhi pade meri tarah.... Main 3 mont se bilkul bhi grid use nhi kar rha hu 575watts ke 4panel use kiya hu 4battery ke sath. Solar panel ke sath eska best result Milega aapko.
App sahi kahte ho.. seller se send Kar diya and mene check nahi kiya ki service hai ya nahi Maharashtra mai. Because eapro badi company hai.. baki sab Acha inverter hai.no doubt
0 consumption तो सायद ही जो किसी भी ट्रांसफार्मर वाले इन्वर्टर में फिर भी अन्य से तो हर तरह से अच्छा ही है मैं ख़ुद यूज करता हूँ। हा हो सकता है कंपनी अपना कार्य क्षेत्र अभी महाराष्ट्र में बढ़ा ना पायी हो. ये सब ऑनलाइन का जादू हो सकता है😅। और जहाँ तक मैं महसूस कर पाया हूँ आप तो ज्ञानी लग रहे हो तो आपने कुछ सोच कर और अच्छै से कॉम्पेरिजन करके ही लिया होगा। वैसे चलता तो अच्छा से परतीत हो रहा है फिर भी पता नहीं क्या शिकायत है
बिल्कुल सही कहा चलता तो बहुत अच्छा कोई भी प्रॉब्लम नहीं है और जिस डीलर से हमने लिया उसने झूठ बोला कि महाराष्ट्र में इसकी सर्विस है. लेकिन मैं कंपनी से बात किया, कंपनी ने सीरियल नंबर से चेक किया यह थोड़ा आउटडेटेड है इसमें सॉफ्टवेयर को अपडेट करना पड़ेगा. कंपनी ने बताया कि अगर बैटरी फुल चार्ज है तो 45 मिनट के बाद में ट्रांसफार्मर को बंद कर देना चाहिए यह सॉफ्टवेयर के दवारा होता है लेकिन यह अभी हो नहीं रहा तो यह इसमें फॉल्ट है
Bro.. self consumption to 4.32 watts hi hai.. video fir se dekho. Yaha main problem charging transformer ki hai Jo ki ideally shutdown hona chahiye. Self consumption and grid consumption dono alag topic hai..Mera point grid consumption se hai
Bahut hi ghatiya service h 10 din beet Gaye complaint kiye hue abhi tak koi bhi engineer nahin aaya naahi company se phone aaya nahin koi update company wale phone nahi uthate Hain
Invater ka kohi problem nehi Invater ka main line off karne se no load battery se 50watts lega or main hoga to main se 50,,70 watts legali legai....sabi inverter aisa hota he leking watts kam Jada hota...he... Asapower inverter kam leta he
Sabse ghatiya service hai apki problem kya hoti hai or change kya karte hain or arts ki price bhi alag alag batate hain or service se pahle payment maangte hain
Mera complaint karne ke bad banae bhi nahin to complaint band bhi kar diya vah kya kar diya dobara complaint ki bahut hadkaya ki Manali ka mukadma kar denge FIR karenge tab jakar ke aage banaya hai
@@imsudhirjha new Wale searis mai software update bol rahe hai..50. Min ke bad transformer band hona chahiye. But service centre dekh lena hai ya nahi pass mai.
मै भी ऐप्रो Company का Solar Inverter खरिद्नेके तैयारी थी, अब ये Video जब देखा तो बिल्कुल मना कर रहहु। दुसरा जो Custermer को आच्छा service provide करने वाला company का ही search करके खरिदुँगा।
@@sandeepvashishta3732 circuit DC par chalta hai.. Jo ki 0.1 Amp hai agree hu ki 0.1 Amp thik hai itna to leta hi hai and company ke user manual mai bhi itna hai..but AC ka 0.5 ka issue hai. Company ne agree kiya hai ki hum ise thik kar ke dege..
@@umedsingh1810 Nahi Bro.. ye seller/retailer ka galti hai.. Eapro ne bola ki Maharashtra mai hamara service nahi hai..seller se Bina Chek kiya send Kar diya.
Sir Solar ke sath es inverter me koi bhi problems aapko jaldi dekhane ko nhi milega aap khud es inverter ki tarif karege. Hamare yaha Ghazipur up me 24 hours ke ander service mil jati hai.
Mere pass iska naya model hai tron 3200 jab tak inverter ko subah reset na karo solar per battery charge karni shuru nahin karta company ne update ke naam pe dono card change kar diye ab software update karne ke liye kahte hain
42.8 watts with 0.36PF is inverter idle draw. Currently, Idle draw supply is sourced from grid, not batteries or solar. If you disconnect the grid, idle draw will come from batteries and solar (these inverters do DC+DC mixing). You need to disconnect grid/mains to make sure that Inverter own power is not coming from Grid. Also SL4 setting will not help you since SL1-4 setting is for charge controller with RTC clock whereas your concern is with device/inverter own power draw. This is normal in all tranformer based inverters. 40watts consumption on aluminium based and 25-30 watts on copper based. Gamma 3350 also consumes 40 watts.
If you are worried about 0.36 PF, just power on some load and PF will improve. Again this is by design on how transformer work.
Currently, only Ashapower and UTL Gamma is the one which doesn't draw its own power consumption from Grid.
Ashapower is far superior in all aspects but not value for money, especially if you have sized your solution appropriately and keep the grid disconnected.
If you want some automation, just use a smart switch/relay to control Mains supply to inverter.
My normal 12v 900va inverter idle draw is 24 watts. So you can relate that 42 watts is ok.
I hope it helps.
Saggu Sahib. Thank you so much. It is nice help and describe in details. I have installed smart MCB and supplying main grid only two hours per day. Company said this product software is not updated. In ideal condition transformer should be get switched off.
@@Desi.Engineer ask if they can replace card or update firmware/controller chip in future.
Best comment.
@@ZenInnovations yes, bhai bahut technical bamda hai
Hi Saggu ji,
Explore an EAPRO new series of inverters Power Saver Series, which consumes zero power form Grid when it seems battery is full.
From my view point your inverter is fully normal it will consume some current to run itself when you will install solar panels on it you will not feel the pinch of commercial supply. I am using 48 v model without adding gride supply in fact mains are switched off since second day of installation. Your decision of buying this inverter is correct and results will be seen after installing panels. Tks
You are right sir. Company accepted that this need to update software. After 45 mins charging transformer should shutdown but as of now it's on for 24 hours.
Hi Desi ji,
Can you share any proof or written email from the company in which the Company accepted that need to update the software in inverter. I think you are miss guided or miss guide others.
Hi Vijay ji,
You are right.
It is the no load power consumption of the inverter during Grid Mode. All inverters in the market are coming with that loss.
But EAPRO launch new series in which these losses are saved through technology. The EAPRO new series inverters are Power Saver series
@@anuragpandey5101 Yes, I have recorded the call details. I'm not misguiding. I don't have any business in the same. Call me 9041398230. will share call recordings where the company person is asking to update the software. Even though they agreed to send the product for updating, they stopped picking up my calls and I even stopped follow-ups.
@@anuragpandey5101 Right they asked me to share the serial number then came to me and asked to update the software. Sir, I'm not misguiding. even I said at the start of the video that the product is good but only this is the main problem.
Ye ap ka purana wala model hai ya AI wala new model hai?
Thik hua jo problem tha power factor ka?
Mere sath bhi yahi problem h epro3200 me
Vese utl 3350va ka ivertar kesa h
Utl bhi same hai..but eapro se thik hai
Explore EAPRO new series of inverters Power Saver Series which will solve your problem Trust me no inverter manufacturers will help you to minimise those losses.
@@Desi.Engineer mera epro3200 lod off karke 1 amp leta h utl pawar los kitna krta h
@@ajaykumarpilkhuwa chat.whatsapp.com/INEW6iGl96gCAOJVGzcsFJ
Ye group join karo. Sab ans milega..mere pass utl nahi hai.. but log ashapwer acha Bata rahe hai
Sehi h sir m bi lyny ki soch he reha ta ...7-03-2024 pr ab nhi luga jb service me hi problem h to ..
M haryana sy hu district Palwal
20k rs do or problem ho TB Rona kya fayda esy
Maine bhi liya hai 6 month ho gaye mast chal raha hai mere pass 3000 watt biyfacial panel laga hai grid 6 month se band hai 😅😅😅😅😅
Do not buy Eapro
Proper input & output ka connection kariye sahi ho jayega.
Please suggest me a good inverter in 24 volt
@@rohansarode apke pass local eapro ka authorised dealer hai to eapro ki power saving searies le lo..but ye dekh lena eapro ka service hai ya nahi.. online mat lena local market main Jake lena.
Me ahmednagar maharashtra se hu
Pune me service center nahi hai to hamare yaha khak milegi service
@@rohansarode fir eapro mat lena. UTL ka le lo. Acha hai 24 v mai
Durasol pcu 3370 madel
This model is over hyped..... It has software program flaw... Overcast for few minutes, it will supply power from main instead of batteries... Where as Smarten will supply power from batteries after solar panel.. Only shift to main after discharging of batteries to a pre-selected value.... smart logic board or software program is far better with Smarten MPPT inverter. EAPRO has higher power rating, you can install more solar panel... But what's the use if it switch to main in daytime whenever little cloud. Of course you can manually disconnect the main... but why to intervene when one can design better software program.
@@srisaikat totally agree with you, even company staff also agreed. They are just focus on raw output and input without manage.
सर् sl-4 की सेटिंग के बारे में डिटेल्स से बताइए क्योंकि sl 4 में सेट करने पर साथ ही ग्रिड से चार्जिंग ऑन होने पर और लोड डालने पर यह लोड को ग्रिड में शिफ्ट हो जाता है न कि बैटरी पर
हालांकि चार्जिंग सोलर से ही करता है।
और सुबह 6-10 (सेटिंग के अनुसार डिसएबल है)तक मे यह सारा लोड ग्रिड पर ही शिफ्ट करता है ।
मेरे पास 48 बोल्ट का सेट अप है 2200 वाट पैनल के साथ मे।
Apna number do. Apko ik group mai add karta hu
@@Desi.Engineer आप अपना नम्बर भी दे दे आपसे कुछ पूंछना है
@@shivamshuklaram 9041398230
42w 24v inviter ok (mara Microteck12v non solar inviter 15h charging hota haa charging time 200w sa 280w normal full charging ki bad 30w sa 50w lata haa all time ) no problem 😀😀😀
सर हमारे पास लुमिनस का 2350 मॉडल नंबर इनवर्टर है सोलर इन्वर्टर वह इनवर्टर 60% बैटरी रहने के बाद इनवर्टर ऑफ हो जाता है कोई लोड नहीं चलता है इनवर्टर में 60% बैटरी बताता है उसके लिए सॉल्यूशन बताइए आपका सब चैनल सब्सक्राइब कर लिया है
@@kamtamaurya5180 app apna number de. Ya WhatsApp kare pls. 9041398230
Mai apko ik solar wale group mai add karuga. Mai to itna janta nahi ho but apka help jarur ki jayegi.
@@kamtamaurya5180 aap humara isi channel pe desorption m solar group ka link Diya huya hai solarheplline channel
Sir Delhi main bhi nahi hai service mere paas bhi hai 48 volts kuch problem ayi thi phek ke doosra hi lagana pada
Name ka hi eapro global hai
@@Desi.Engineer global hai bhai america me lete to service milti, domestic nahi hai
, 6पैनल 330वॉट सीरीज मे लगा सकते हैं सर किया
@@sbbjbilarabilara4736 panel ka voc kya hai.. Max input 110v hai.6x36=216 possible nahi hai .mene apne farm mai statcon ka lagaya hai jo jain irrigation ka system hai. Inverter ka input range 230v hai. And 7 panel series mai lagaye hai.
th-cam.com/video/bqAZCTrKwfE/w-d-xo.htmlsi=D47PZzh0JRG2NoDw
same problem here
All transfarmer inverter do same power loss, use solar plates to reduce power loss.
Only using solar plates is solution.
Thanks.
Sir inverter us brand ka lena chahiye jeska service network aapke near me ho , aapne galti ki hai, epro ka network Pune side me bhut kam hai,
Agree karta hu..ye bat mere ko Pata nahi thi and eapro walo ne batayi. Seller ki mistake hai..kuch paisa ke liye apna product none service area mai bhej diya.
Kanpur me service hai kya
Kanpur ke liye aap eapro ke authorised dealer se baat kare bahi aapko sahi information denge.
@@ankitchauhan1162 Bhai Maine India mart se liya tha yehi pata karna hai ki service hai ya nahi kanpur me kyu ki eapro ke customer care Wale reply Tak nahi kar rahe hai bahut bekar company hai kisi ko lene ke liye mat bolna
@@kanpuroutlet hona chahiye. Ik bar toll free number par bat karo
aluminum tranformer ka loss hai ye
Bad service epro
Power factor har inverter mai hota hai aap cellcronic lagate usme power factor nahi hota
Agree, mera concern hai ki battery charge nahi kare tab transformer to off kar de. inka chip design aisa hona chahiye
Sir Aap Durasol company ka use kro 3370 model
Kya aap Durasol use ker rahe hai to uska information de
Sir Mera toh 7 month ho gaya h koi dikkat Nahi Huwa h
#capacitor lgao #pf thik hoga try karo different value ke
Sure bro
Solarhelpline official TH-cam channel h humara
Sir aapne sahi kaha hai ye phone ya email par koi response nhi dete hai
Delhi wale log bhi rote hai. waha bhi service nahi de pa rahe.. After sale service to achi hona hi chahiye. electronic cheese hai kabhi bi problem aa sakti hai.
I think you are that customer for which EAPRO was launched new series of inverters Power Saver Series which saves your energy during this time
Aap smart plug ya timer lga lo
Yes, laga diya..ab daily 3 hours main grid on karta hu
This is best inverter because I m use.
Aapka display meter sahi nhi h .
Mere Ghar par 0.00 load dikhata h.
Company claim Kar rahi hai ki iska software update karne wala hai. Mere pass 2 meter hai.. dono same reading late hai
Dear Desi ji,
Can you share any proof of claim of software update. It is EAPRO new series of inverters Power Saver Series which have such power saving features.
Eapro company is the worst company in Indian market. People working for Eapro are absolute idiots. Sales as well as service
What happened bro
Mera eapro sahi chal rha hai
लोड टेस्ट बताना कितना वॉट ले रहा है मीटर में
1800 watts test kiya huya hai..only battery par. Apka question kuch or hai to details mai pucho..jarur help karuga.
Inverter की लोड छमता क्या है अधिकतान कितना लोड उठा सकता है
3000 va है तो 2500 वॉट लोड छमता होना चाहिए बैटरी से लाइट बंद की हालत में
2150 watt 9.5 amp max solar panel ke sath thoda improve kar jata hai 2200 watt tak
Sir koi saman kitana achha kyo na ho lene se pahale service centre jarur check kar le. Dusari baat sir es inverter par aap 3500watts panel ke sath 2battery our add kar le sayad aapko grid ki jarurat hi nhi pade meri tarah.... Main 3 mont se bilkul bhi grid use nhi kar rha hu 575watts ke 4panel use kiya hu 4battery ke sath. Solar panel ke sath eska best result Milega aapko.
App sahi kahte ho.. seller se send Kar diya and mene check nahi kiya ki service hai ya nahi Maharashtra mai. Because eapro badi company hai.. baki sab Acha inverter hai.no doubt
Bhai raat main AC kaise chalayenge bina grid ke
Any update?
No bro. They are not picking phone. Problem is still there.
0 consumption तो सायद ही जो किसी भी ट्रांसफार्मर वाले इन्वर्टर में फिर भी अन्य से तो हर तरह से अच्छा ही है मैं ख़ुद यूज करता हूँ। हा हो सकता है कंपनी अपना कार्य क्षेत्र अभी महाराष्ट्र में बढ़ा ना पायी हो. ये सब ऑनलाइन का जादू हो सकता है😅। और जहाँ तक मैं महसूस कर पाया हूँ आप तो ज्ञानी लग रहे हो तो आपने कुछ सोच कर और अच्छै से कॉम्पेरिजन करके ही लिया होगा। वैसे चलता तो अच्छा से परतीत हो रहा है फिर भी पता नहीं क्या शिकायत है
बिल्कुल सही कहा चलता तो बहुत अच्छा कोई भी प्रॉब्लम नहीं है और जिस डीलर से हमने लिया उसने झूठ बोला कि महाराष्ट्र में इसकी सर्विस है. लेकिन मैं कंपनी से बात किया, कंपनी ने सीरियल नंबर से चेक किया यह थोड़ा आउटडेटेड है इसमें सॉफ्टवेयर को अपडेट करना पड़ेगा. कंपनी ने बताया कि अगर बैटरी फुल चार्ज है तो 45 मिनट के बाद में ट्रांसफार्मर को बंद कर देना चाहिए यह सॉफ्टवेयर के दवारा होता है लेकिन यह अभी हो नहीं रहा तो यह इसमें फॉल्ट है
apne kb lia tha manufacturing date kbki h m lene ka soch rha hu lu ya nhi m meerut up se hu @@Desi.Engineer
@@thetyagiunboxer2611 mene 15 months back liya tha. Ab new model aa gaya hai..wo le lo.
@@thetyagiunboxer2611Meerut main maine liya hai bahut slow service hai
Good job❤❤
Out put kitna watt hai
1800 watts tak only battery par test kiya huya hai.
Apne wire ko rol kiya h to amp bta rha h
@@Shahidali-hw8vf ok ji. Try karta hu role hata ke.. thanks
Bhai Maine bhi liya tha,mera bhi same problem tha,aur mera 2200rupya cut ker liya
42 watt inverter ki self consumption hai bhai sahab
Bro.. self consumption to 4.32 watts hi hai.. video fir se dekho. Yaha main problem charging transformer ki hai Jo ki ideally shutdown hona chahiye.
Self consumption and grid consumption dono alag topic hai..Mera point grid consumption se hai
बिल्कुल सही बात मैं मिर्जापुर से हू हमने भी 4 महीने से कॉल किया है आज तक कोई इंजीनियर नहीं आया इप्रो का इनवर्टर कभी नहीं लेना
@@Ashok_dhar_ bhai app mirjapur bol dete to mai samaj jata ki up mai hai😁. mirjapur ko kon nahi janta.
Yes true after sale service nahi hai.
Mera 7th Mahina ho gaya hai koi problem nahin aaya h
Mirzapur
Sahi hai
Up azamgarh Mera kharab hua tha 2 din me Sahi Karke dia tha❤❤
Doosre inverter ka bhi kya bharosa
Doosre inverter ka service mil jata hai na
Bahut hi ghatiya service h 10 din beet Gaye complaint kiye hue abhi tak koi bhi engineer nahin aaya naahi company se phone aaya nahin koi update company wale phone nahi uthate Hain
Same here..Mera phone bhi band Kar diya uthana.
Epro company vry bad and company service also vry bad...only 0 Star
Invater ka kohi problem nehi
Invater ka main line off karne se no load battery se 50watts lega or main hoga to main se 50,,70 watts legali legai....sabi inverter aisa hota he leking watts kam Jada hota...he...
Asapower inverter kam leta he
Ok. Sayed app sahi ho.. main off Kar test karta hu and update karta hu
Yes...main line off karne bath battery se and main line on kar k line se leta he all time 20wats se 30 watts
@@solerandelectric636 ok ji
Ap gride charging all time off kar do...fir dikho electric input ampire
.10 se .15 ho jayegi
Sabse ghatiya service hai apki problem kya hoti hai or change kya karte hain or arts ki price bhi alag alag batate hain or service se pahle payment maangte hain
After sale service to hai mere pass to 2-3 baar aya hai engineer
Pune mai nahi hai. Ye dealer ka problem hai. Without service zone check kiye send Kar diya
Mera complaint karne ke bad banae bhi nahin to complaint band bhi kar diya vah kya kar diya dobara complaint ki bahut hadkaya ki Manali ka mukadma kar denge FIR karenge tab jakar ke aage banaya hai
@@jamalquraishi9754 Mera to consumer ka complaint bhi close kar diya.bole none service area
Solar inverter solar se chalana h aap grid se kyun chalate h
यह सब लोकल ब्रांड है इसीलिए तो चोलेतो, साम तोक नहीं तो साल तोक 😅😊
@@AkhandBharatChanakyaNiti sahi bole app
Solar se related ke jankari ke liye humse contact kar sakte h
Inki service nahi hai
Are sir watt to only 42 hi h
Meter ki reading Amp par chalti hai...0.5 amp leta hai..power factor ka concept dekho
Zero after sell service
@@Vlog_bsr agree Dehli jaise location par service nahi hai to kya product selling Kar rahe hai..
@@Desi.Engineer mujhe 6 month ho gye the invertor buy kiye hue .abi thk mere invertor registered ni hua h. i don't find any way to register warranty.
@@Desi.Engineer customer care number milta ni h
@@Desi.Engineerth-cam.com/video/G-6FkOiJy_A/w-d-xo.htmlsi=xLLp9E1XhzIvz-ta
Bhai ye 2 ampere consume kar raha ha to v acha hai .. low frequency krta h itna
Charging off ke time Charging transformer off Kar Dena chahiye system ne.
😊😊😊😊
फिर दूसरा उपाय क्या है
@@imsudhirjha new Wale searis mai software update bol rahe hai..50. Min ke bad transformer band hona chahiye. But service centre dekh lena hai ya nahi pass mai.
Dosri Baar kharab hua to 2mahene tak aya hi nahi fir Apne paise se 1500. Dekar thek karvaya hun
Sarvic ghatiya hai😭😭😭😭😭😭😭😭
@@SaifSaif-v2s right service to nahi hai.. product acha hai but electronic cheese hai..kabhi kharab ho jaye to service milna chahiye
EAPRO INVERTER BAKWAS HAE Sarvesh Nahi deparahahe hai hamid electricals
Product ka price bahut low rakha hai isliye servicing afford nahi kar paa Rahi hogi company.
Agree.UTL bhi almost same hai
Are bhai 45 se 50 watt pcb khati h bina charging ke bhi
Ye transformer le raha hai..jab battery charge nahi kar rha hota to pcb design aisa ho ki transformer ki light cut kare.
@@Desi.Engineer are Itna are inverter lete Hoge aur isse jyada hi lete honge
मै भी ऐप्रो Company का Solar Inverter खरिद्नेके तैयारी थी, अब ये Video जब देखा तो बिल्कुल मना कर रहहु।
दुसरा जो Custermer को आच्छा service provide करने वाला company का ही search करके खरिदुँगा।
@@SanjayLimboo-uf8ni online mat lena. Local authorised dealer se Lena.. check karna authorised hai ya nahi dealer
Sir Mera 7 mahina ho gaya hai abhi Tak Koi Problem Nahi aya h
Please do not buy eapro inverter lot of problems i am facing I lost my 25000rs
What happened bro. Please share your problem in details so other can take help
हर transformer वाले inverter मे
इतना load तो होता ही है
ये कोई कमी नहीं है
Right.. but chip design aisa ho ki transformer ko band kar de. And aisa design normal hai 30 min idel ke bad transformer band ho jata hai
@@Desi.Engineer
Circuit को चलाने के लिए कुछ voltage तो चाहिए ही होती है
Cut कैसे कर देंगे
बार बार cut होने से mosfet उड़ जाएंगे
@@sandeepvashishta3732 company ne claim kiya hai ki isme problem hai.. and thik karne ko bola hai..
@@Desi.Engineer
ये कोई प्रॉब्लम नहीं है
इतना load हर inverter लेता है
Transformerless थोड़ा कम लेता है
लेकिन circuit चलाने के लिए कुछ load तो लेगा ही
@@sandeepvashishta3732 circuit DC par chalta hai.. Jo ki 0.1 Amp hai agree hu ki 0.1 Amp thik hai itna to leta hi hai and company ke user manual mai bhi itna hai..but AC ka 0.5 ka issue hai. Company ne agree kiya hai ki hum ise thik kar ke dege..
Pune bohat dur hei
Service keliye इंकार करेगा क्योंकि वहा पर कोई डीलर नही होंगे
Aap isko Din Me Solar pe chalaye
Raat ko By Pass kardo
Copper Based inverter khud hi Power Consume kar lete hai Yeh inki Nature hai.
right, Mai socity mai rahta hu and 1 saal tak solar panel nahi laga skta. Appril mai solar panel laga raha hu 1 year society buildup ke bad
Sir kya aap kisko directly electric supply par used krta ho???
Explore EAPRO new series of inverters Power Saver Series which saves your energy which is wasted by other inverter manufacturers.
Dinesh ji naya Power Saver Series inverter kharidiye jisme ye loss nahi hota.
Raat Ko bye pass per chalane per light jane pe andhera ho jayega
Mera to complaint karne ke bad
सर्विस सही नहीं देते
Pune mai service nahi hai
जन हित मे अच्छी जानकारी सांझा की प्रशंसा करनी तो बनती हे।
Thanks 😄
उपभोक्ता अदलात जरूर आपके साथ न्याय करेगी।
@@umedsingh1810 Nahi Bro.. ye seller/retailer ka galti hai.. Eapro ne bola ki Maharashtra mai hamara service nahi hai..seller se Bina Chek kiya send Kar diya.
j koi problem ni hai company walo ese gahak ko inverter nhi dena chahiye
Fudu inverter h koi na khride
😂😂😂
Thanks bhai m bhi lene ja rha tha but ab nhi
Explore EAPRO new series of inverters Power Saver Series which saves your energy which is wasted by other inverters.
Aap ispar 3000watt biyfacial panel laga de aap bhul jaooge power factor
yes, Main curt kar ke p[anel lagane wala hu.
Sir Solar ke sath es inverter me koi bhi problems aapko jaldi dekhane ko nhi milega aap khud es inverter ki tarif karege. Hamare yaha Ghazipur up me 24 hours ke ander service mil jati hai.
Agree. Baki to bahut Acha hai inverter.
Mere pass iska naya model hai tron 3200 jab tak inverter ko subah reset na karo solar per battery charge karni shuru nahin karta company ne update ke naam pe dono card change kar diye ab software update karne ke liye kahte hain
Up azamgarh Mera kharab hua tha 2 din me Sahi Karke dia tha❤❤
Hello Bhai mai bhi Azamgarh se hun mujhe bhi ye inverter Lena hai bataiye kaisa hai ye model
@@usfact_new modal to thek hai par sarvis nahi milti zero hai