To my experience do not use redymade foot valve which has small holes and short in size instead make ur own foot valve like old model that is making big holes in HDPE hose itself and inserting bend air hose inside make it upto 6 feet long try to put more number of holes which gives more water for long period of time
Air delivery nala iruka bro Compressior la air outlet la union irukum atha kalatitu air flow epdi iruku nu patuinga kaiya vashu paruinga kaiya vea air thalum
Hello, if we don't fit the dummy at the bottom, may I know what will be the impact? In our village, we will not close the foot valve with dummy. I feel this method is very effective so thought of checking. Thank you.
@@EverythingLearningToday thanks bro. I recently installed the compressor pump in my borewell which is about 930 feet. Very newly installed (12 Sep 2020). I am not satisfied with the output. I noticed there are few air leaks at the joint in the air pipe and the water discharge is poor. For every 5 mins of compressing I get 2.5 mins of discharge. The next discharge is after 5 mins of compressing. This could be due to air leak which i will fix it in couple of days. Since I have not covered the foot valve with dummy, I also got a doubt that the poor discharge may be for not putting the dummy. The water head is at 472 feet
@@EverythingLearningToday It is 2 HP, 2 stage, compressor with 3 phase motor. BAC make (Bakgiyam Engineering Pvt ltd). When I posted the requirement in India mart website many suppliers from Coimbatore contacted me and asked my requirement. My requirement was to pump the water from 930 feet and the water head is at 472 feet. So the accumulated water level in the borewell is 458 feet. Out of 10 suppliers, everyone recommended either 3 hp or 5 hp except BAC. Based on their promise and wordings I went with their recommendation. I am yet to completely experience the outcome as there are some air leaks. Once I fix all the leaks, I will come to know the real picture. When I called them, their response was "is compressor working? I said, yes; is air is coming? I said, yes. Then the compressor is fine. The problem would be there is no water when I clearly know there is enough water (458 feet of water inside my bore). They also said if you don't have enough source even if you put 100 hp motor you will not get water. Which we all know. But in my case I clearly said them that there is water for 458 feet but there are not in a position to hear me out.
Hi BRO agriculture use ku 5hp two stage compressor with diesel engine connect pannlanu plan pannirukom.water pipe 1 1/2 inch ,air pipe 3/4 inch use pannalama? Bore depth 400ft Water level 50ft Bore size 6 1/2 inch Please advise which pipe size is suitable for my condition? Water pipe size ? Air pipe size?
Very helpful for my instalation thanku thaliva👏
தண்ணி வந்தா பாக்கலாம்னு பாத்தா மறைவா அடிச்சிட்டியே😁😁😁😁😁
This is local make pipe.....we are manufacturing pvc foot valve pipe for 20yrs with good quality supplier for texmo, v guard ,Crompton,
Why should we close the foot valve by dummy?
To my experience do not use redymade foot valve which has small holes and short in size instead make ur own foot valve like old model that is making big holes in HDPE hose itself and inserting bend air hose inside make it upto 6 feet long try to put more number of holes which gives more water for long period of time
Bro air compressor water கூட mud calcium வருது இது pipe la அடசுக்குது எப்படி சரி செய்வது
Bore hole oda hose height kamiya irukanum bro
hose ah fulla bore hole earakuna ipdi problem varum
Super
Water out put video poduinga anna
Future video la kandipa poduran bro
போர் போட்ட பிறகு எவ்வளவு நேரம் கழித்து air compressor பயன்படுத்தலாம்
Water level ah poruthu iruku
@@EverythingLearningToday ok thank you
Bro water compressor sound over please tell me solut
Change the oil and check it's piston rings
👍supper
Bro nanga 430 feet ku hose erakumom frst thanni nalla vandhuchu ipo one year kalichu thanni 1 hour ku 5 kodam thanni dhan varudhu enna prblm bro
Ena motor bro
@@EverythingLearningToday suguna 2 hp compressor bro
Air delivery nala iruka bro
Compressior la air outlet la union irukum atha kalatitu air flow epdi iruku nu patuinga kaiya vashu paruinga kaiya vea air thalum
Apdi air flow nala irutha bore hole la ula hose ah lift panni paruinga easy ah thuika varum apdi varala na hose siki irukum athunala kuda water kidakathu
@@EverythingLearningToday motor la pipe la hole irundhuruku BRO adhan air leak airuku sari panniyachu thnks bro
Bro, ippo neenga mathunathu nalla irukku air pipela air varamatinguthu thampi yeara matinguthu enna problemah irukkum please reply me
Compressor la air leak iruka akka
Illa pa
Air delivery compressor la nala iruka check pannuinga
Bro intha pipe mathiyachu theni trumla pottu pathom thanni veliya koppulikuthu ithu sariya ana thanni lighta eruthu tankla eramatinguthu enna problem bro lock downla yarum vara matingranga
wasima261@gmail.com ithu en mail ID akka ithuku unga problem ah video anupuinga nan pathu sollura
Superb
please give company name where you had buy it
This is local make pipe.....we are manufacturing for 20yrs with good quality supplier for texmo, v guard ,Crompton,
Hello, if we don't fit the dummy at the bottom, may I know what will be the impact? In our village, we will not close the foot valve with dummy. I feel this method is very effective so thought of checking. Thank you.
Yes bro dummy is not compulsary,
Dummy is preventive from root block and soil block issues
@@EverythingLearningToday thanks bro. I recently installed the compressor pump in my borewell which is about 930 feet. Very newly installed (12 Sep 2020). I am not satisfied with the output. I noticed there are few air leaks at the joint in the air pipe and the water discharge is poor.
For every 5 mins of compressing I get 2.5 mins of discharge. The next discharge is after 5 mins of compressing. This could be due to air leak which i will fix it in couple of days. Since I have not covered the foot valve with dummy, I also got a doubt that the poor discharge may be for not putting the dummy.
The water head is at 472 feet
No bro dummy is only for dust prevention,
What is your compressor hp ?
@@EverythingLearningToday It is 2 HP, 2 stage, compressor with 3 phase motor. BAC make (Bakgiyam Engineering Pvt ltd). When I posted the requirement in India mart website many suppliers from Coimbatore contacted me and asked my requirement. My requirement was to pump the water from 930 feet and the water head is at 472 feet. So the accumulated water level in the borewell is 458 feet. Out of 10 suppliers, everyone recommended either 3 hp or 5 hp except BAC. Based on their promise and wordings I went with their recommendation. I am yet to completely experience the outcome as there are some air leaks. Once I fix all the leaks, I will come to know the real picture. When I called them, their response was "is compressor working? I said, yes; is air is coming? I said, yes. Then the compressor is fine. The problem would be there is no water when I clearly know there is enough water (458 feet of water inside my bore). They also said if you don't have enough source even if you put 100 hp motor you will not get water. Which we all know. But in my case I clearly said them that there is water for 458 feet but there are not in a position to hear me out.
wasima261@gmail.com this is my mail ID bro pls sent the output of ur compressor and HDEP hose
Aiyoo yagayum water illa water niga panurathu 300 to 500 feet thana poduriga 🙏
350 feet bro
Can we use casing pipe itself for delivery of water
Sorry bro i can not understand ur word
Cap illenna ethavuth pechana irukka..
Problem illa,
Cap podalana dust aadakathu most ah root adachukum apdi eathum problem illatha place la cap poda venam
i want company details so that i can buy it
You need a brand detail of metrial
550 அடி ஒஸ் இறக்கு உள்ளோம் 2 HP BAC compressor 400 அடி வரை உள்ள தண்ணீர் மட்டுமே வருகிறது அதற்கு மேல் உள்ள நீர் மிக மிக குறைவாக வருகிறது காரணம் என்ன?
Bore length ena brother
Borewell 900 ft water level ipa 400 ft la iruku
Compressor oil change pannuinga air flow nala iruka
Delivery air heat ah varutha nu paruinga
Air nala varudhu bro and air heat ila apro 350 varaikum water nala varuthu athuku Mela tha rompa late agudhu
Hindi me
Hi BRO
agriculture use ku 5hp two stage compressor with diesel engine connect pannlanu plan pannirukom.water pipe 1 1/2 inch ,air pipe 3/4 inch use pannalama?
Bore depth 400ft
Water level 50ft
Bore size 6 1/2 inch
Please advise which pipe size is suitable for my condition?
Water pipe size ?
Air pipe size?
Pipe size and air hose size rendum correct ah select pannirukinga eathum change panna venam correct ah irukum
@@EverythingLearningToday
Thanks for your repley.
Bro appa water pipe 1 1/2 Inch
Air pipe 3/4 inch use pannalanu solringala.
Yes