FILAMENT EXTRUDER PART 8 * HOW TO WIRE * BERME REX-C100 * FOTEK SSR-40DA *HEATER ELEMENT*TERMOCOUPLE

แชร์
ฝัง
  • เผยแพร่เมื่อ 29 มี.ค. 2019
  • THIS IS STEP BY STEP INSTRUCTIONS.
    ---------------------------------------------------------------------------------------------------
    DIY FILAMENT EXTRUDER • FILAMENT EXTRUDER PART...
    DIY FILAMENT EXTRUDER • FILAMENT EXTRUDER PART...
    DIY FIRST HDPE 3D PRINT • FIRST HDPE 3D PRINT WI...
    DIY CNC ROUTER • CNC ROUTER MY SECOND P...
    DIY 3D PRINTER • 3D PRINTER BUILD PART...
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 79

  • @CNCEVOLUTION
    @CNCEVOLUTION  4 ปีที่แล้ว +5

    IF YOU LIKE THIS VIDEO PLEASE GIVE A LIKE, SHARE AND SUBSCRIBE

  • @deathmog1
    @deathmog1 3 ปีที่แล้ว +6

    it took me forever to find a video as straight-forward as this. thank you!!

  • @Tadek5
    @Tadek5 3 หลายเดือนก่อน +1

    Short and to the point. No empty talk. You have a big plus for these presentations. Regards.

  • @bouchaibbisbis6757
    @bouchaibbisbis6757 ปีที่แล้ว

    the best tutorial about wiring rex-c100, I've tested it just now and it works well. thank you mate

  • @RuboaArts
    @RuboaArts 3 ปีที่แล้ว +2

    That is all I needed. And the first out of many to give to me straight. Thanks

  • @chrisyu98
    @chrisyu98 2 ปีที่แล้ว +1

    straightforward, simple, best of all no stupid music!

  • @richsrandomcollection9352
    @richsrandomcollection9352 4 ปีที่แล้ว +4

    Easiest explanation I have seen, thank you

  • @nedjokovanovic9100
    @nedjokovanovic9100 4 ปีที่แล้ว +2

    Thank you man! You saved me the pain!

  • @clarkgriswold2181
    @clarkgriswold2181 5 หลายเดือนก่อน +2

    Best video ever 🎉

  • @bradleymcglynn5219
    @bradleymcglynn5219 4 ปีที่แล้ว +1

    Straight forward..... thanks mate 👍🏻

  • @1whatever100
    @1whatever100 4 ปีที่แล้ว +1

    Thank you for making it so I could understand.

  • @beekeeperDV
    @beekeeperDV 4 ปีที่แล้ว +1

    Best of the best

  • @unclealig
    @unclealig 3 ปีที่แล้ว +1

    whats the PID output pin 4+5 (to connect the SSR)? is it a TTL or Logic output?

  • @doughsnakes
    @doughsnakes 7 หลายเดือนก่อน

    Thank you

  • @nimnem5759
    @nimnem5759 3 ปีที่แล้ว +1

    Can you make the video about connecting heater band with barrel of injection molding machine?

  • @eduardogarzavaldez3745
    @eduardogarzavaldez3745 2 ปีที่แล้ว +1

    I got a crouzet solid state input & output AC, cannot connect the output resistance correctly, I would be very grateful if someone could explain me

  • @winterxshiroe3762
    @winterxshiroe3762 2 ปีที่แล้ว +1

    Can I connect a 12v dc silicone heater?

  • @omarrendon2480
    @omarrendon2480 3 ปีที่แล้ว +1

    If I need to connect 3 bands to the same pid, i have to connect them in parallel?, I mean, must I connect the three to pin 2 of ssr relay?

    • @CNCEVOLUTION
      @CNCEVOLUTION  3 ปีที่แล้ว +1

      If you want to connect 3 heating strips, yes, they must be connected in parallel. Connect three band terminals to terminal 2 of the SSR relay and the other three terminals to neutral. Attention, the amperage of the relay must be higher than the amperage consumed by the three heating strips. Depending on the type of machine you are building, several heating strips can be mounted on a single PID temperature controller or a PID temperature controller may be required for each heating strip. In any case, if you install the heating strips in parallel, it is desirable that they be of the same type and the same power.

  • @arkadybaskin5716
    @arkadybaskin5716 3 ปีที่แล้ว +1

    Hi, can I attach the thermoregulator to heating device, what it's maximal possible working temperature?

    • @CNCEVOLUTION
      @CNCEVOLUTION  3 ปีที่แล้ว

      the heating element must only be attached to a relay, it is not attached directly to the thermoregulator

  • @abderrahimkamal8944
    @abderrahimkamal8944 2 ปีที่แล้ว +1

    Svp comment augmentez la tension de sortie entre4.5 de REX -C1000( les paramtére)

  • @user-CzK
    @user-CzK 3 ปีที่แล้ว +1

    Do you have tutorial video how to fix underscale?

  • @kubrakocakoc4859
    @kubrakocakoc4859 2 ปีที่แล้ว +1

    hello, can we use 1 rex 100 and 2 heating clamps? Is there a problem with the heating of the clamps? I want to use 2 handcuffs, 2 mi rex 2

    • @CNCEVOLUTION
      @CNCEVOLUTION  2 ปีที่แล้ว

      you can also use 2 heating strips connected to a single temperature regulator but the strips must be connected in parallel. in this case their voltage will be the same but the amperage adds up or doubles if the bands are identical.

  • @indiaffandi3637
    @indiaffandi3637 3 ปีที่แล้ว +1

    Is the heater band a must? Because when I bought the controller online it didn’t come with the heater band

    • @CNCEVOLUTION
      @CNCEVOLUTION  3 ปีที่แล้ว

      The heating strip does not come with the temperature controller and must be purchased separately.

  • @panjiutomo5253
    @panjiutomo5253 ปีที่แล้ว +1

    Question ,,, what size cable is used *unit millimeter
    Please answer help me , thankyou

  • @user-po6vq1sm9g
    @user-po6vq1sm9g 3 ปีที่แล้ว +2

    Hi, What size of awg wire do you use for connectings?

    • @CNCEVOLUTION
      @CNCEVOLUTION  3 ปีที่แล้ว

      I used a 2 mm cable but you can tell by the temperature of the cable if it is good it is not allowed to heat at all. what installation do you want to do?

    • @user-po6vq1sm9g
      @user-po6vq1sm9g 3 ปีที่แล้ว

      Thank you for reply!!! I'd like to repair furnance for glass (max. aprrox. 1000℃). Its heater don't broken, but Temp. meter don't increase. So, I wanna make Temp. control system.

  • @asr1039
    @asr1039 3 ปีที่แล้ว +1

    Bro i did the same connection the heater does not heats please help me bro

  • @RoyWanfried
    @RoyWanfried ปีที่แล้ว +1

    Hi, i buy an Rex-700 with 4-20mA Output to connect these Output to an Voltage Regulator SSR-40LA with an 4-20mA Input. The Rex-C handle the SSR on and off, but not Volatge up and down like i hope. I cant find the function in settings. Can you help?

    • @CNCEVOLUTION
      @CNCEVOLUTION  ปีที่แล้ว +1

      I don't know this type of temperature regulator, but I did a search on the net and found that you need to change the SL6 parameter in the manual from this link www.aliexpress.com/item/32619348367.html?spm=a2g0o. %2117.0%21%21%21%21%21%402101d64d16618762965143805e68d5%2159353549794%21sea&curPageLogUid=XE5XpdHl7ofl and I also found a video on youtube with something similar th-cam.com/video/6ehal2oFKJE/w-d-xo.html

    • @RoyWanfried
      @RoyWanfried ปีที่แล้ว

      @@CNCEVOLUTION tx, this Parameter is set to 1. But unfortunately its not working right. The relay goes on/of not voltage up/down.

  • @sawmill9392
    @sawmill9392 ปีที่แล้ว +1

    Can the REX C-100 be powered with 12 volt DC auto battery? thanks.

    • @CNCEVOLUTION
      @CNCEVOLUTION  ปีที่แล้ว

      probably just modifying the internal components

  • @Marc2OVER
    @Marc2OVER 11 หลายเดือนก่อน +1

    What about for 100W 220V Heater band? How to connect them to the REX-C100?

    • @CNCEVOLUTION
      @CNCEVOLUTION  11 หลายเดือนก่อน +1

      for 100w 220v the connection is done the same way. the only difference is that the higher the heating band resistance, the bigger the relay must be. for 100w 220v theoretically a 0.5 ampere relay would be enough, but anyway put a bigger one. if you put several heating bands in parallel on the same relay, then their amperage increases proportionally and you will have to use an even bigger relay

  • @omarrendon2480
    @omarrendon2480 3 ปีที่แล้ว +1

    How do you put the heater band at ground?

    • @CNCEVOLUTION
      @CNCEVOLUTION  3 ปีที่แล้ว +1

      in this video the heating band is not grounded but you can put the machine on which you will mount the heating band on the ground

  • @swathis474
    @swathis474 2 ปีที่แล้ว +1

    Can i wire two 300 watt heater to 1 rexc100 pid controller is the power any problem

    • @CNCEVOLUTION
      @CNCEVOLUTION  2 ปีที่แล้ว

      the heating strips do not connect directly to the temperature controller, they connect to a relay and the relay must have a higher amperage than the heating strips. to calculate the amperage you need to know several parameters of the circuit such as the supply voltage and the power factor. The heating strips I have have an alternating 220 volt supply voltage.
      yes you can put two heating strips but you have to connect them in parallel and use a relay as large as possible. I have a 40 amp relay.
      also be careful that the electricity is very dangerous.

  • @andras6592
    @andras6592 3 ปีที่แล้ว +1

    Buna. Am si eu un Rex C100 si un releu Foter SSR 50DA as dori sa- l setez sa-mi intrerupa curentul la o rezistenta (ca un termostat) la 90 de grade (temperatura apei). Efectiv nu-mi dau seama cum? Mie imi cupleaza la temperatura setata. Cum inversez, sa nu cupleze, ci sa-mi decupleze? Te rog daca poti ajuta-ma. Thx.

    • @CNCEVOLUTION
      @CNCEVOLUTION  3 ปีที่แล้ว

      Daca cupleaza la 90 de grade 🤔 apa cum ajunge la 90 de grade? Cine alimenteaza rezistenta pana apa atinge 90 de grade?

    • @andras6592
      @andras6592 3 ปีที่แล้ว

      @@CNCEVOLUTION ​ @CNC EVOLUTION Am 10 panouri solare cu un invertor EAsun I SVII 5kw. Acest sistem o sa alimenteze o rezistenta de 2500W care este introdus intr-un butoi de bere Inox (60 litri) si legat paralel cu cazanul pe lemne. Sistemul meu de incalzire are cam 300 litri de apa. Rezistenta o sa incalzeasca acest sistem dar daca apa din butoi ajunge la 90-95 de grade as dori sa decuplez rezistenta sa nu ajunga la punctul de fierbere. Nu stiu cum sa-l setez. La ARU am setat si valoarea 1 si valoarea 0 dar el cupleaza la temperatura setata nu decupleaza.

    • @andras6592
      @andras6592 3 ปีที่แล้ว +1

      @@CNCEVOLUTION Am rezolvat. La SL 1 am introdus codul 0111 si la SL 6 codul 0101. Merge brici. Multumesc pentru timpul acordat.

  • @evpover1897
    @evpover1897 5 ปีที่แล้ว

    Salut
    Resistenza trebuie sa fie de 220?
    Cum pot sa stiu la priza unde ii plus si Minus ? Sau pot sa le schimb Intre ele

    • @CNCEVOLUTION
      @CNCEVOLUTION  5 ปีที่แล้ว +1

      Salut, daca te referi la rezistenta de tip banda din clip aceasta este pentru curent alternativ (+ si - se schimba de mai multe ori pe secunda) acesta este format din faza si nul de lucru si da nu conteaza cum o conectezi , dar daca nu cunosti nici cele mai elementare principii despre curentul electric din prize nu trebuie sa umbli acolo sub nici o forma, este mortal si e de ajuns sa gresesti o singura data intr-o singura secunda.

  • @adarshchandra12
    @adarshchandra12 ปีที่แล้ว +1

    Hello Sir, i am taking A 12VDC ceramic heater as a load. What is going to be my relay selection for this?

    • @CNCEVOLUTION
      @CNCEVOLUTION  ปีที่แล้ว +1

      You did not specify if you use the rex c100 thermoregulator, nor the power or amperage of the ceramic heater. For the rex c100 thermoregulator you need a SSR-DD relay (DC CONTROL DC) with DC input around 11 volts (fotek 3-32 VDC is good) and the load voltage part around 12 volts (fotek 5-60 VDC is good), the choice of amperage remains, so the SSR-10DD works at 10 amperes. It is good to choose an amperage higher than the amperage of the ceramic heater.
      Specification
      DC Control DC
      Model: SSR-10DD, SSR-25DD, SSR-40DD, SSR-60DD, SSR-80DD, SSR-100DD
      Control mode: DC Control DC(DC-DC)
      Input Voltage: 3-32VDC
      Output Load voltage: 5-60VDC
      Output current: 10A, 25A, 40A, 60A, 80A, 100A
      Control current: 5-25Ma
      On-state voltage:

    • @clamman7505
      @clamman7505 7 หลายเดือนก่อน

      Digital PID Temperature Controller Thermostat REX-C100, only using car battery, heating 12v 50w, would you know are there any instructions or would you have these please?

    • @CNCEVOLUTION
      @CNCEVOLUTION  7 หลายเดือนก่อน

      @@clamman7505 for your requirements rex c100 is not good
      I don't know what kind of heating element you have and at what temperature you use it, but a thermoregulator for a 12v battery would be this it controls up to a maximum of 120 degrees, but you can find many types on AliExpress
      vi.aliexpress.com/item/4001251902793.html?spm=a2g0o.productlist.main.35.3125ElpZElpZnr&algo_pvid=ca15c7f4-523f-4c42-afd3-6bbd7f46d599&aem_p4p_detail=2023110501424320023840273377450002819565&algo_exp_id=ca15c7f4-523f-4c42-afd3-6bbd7f46d599-17&pdp_npi=4%40dis%21RON%2113.06%2113.06%21%21%212.73%21%21%40210324a716991773638193185edb8b%2110000015471624949%21sea%21RO%211703831701%21&curPageLogUid=2N4cneO17hW4&search_p4p_id=2023110501424320023840273377450002819565_18

  • @jkdj4471
    @jkdj4471 3 หลายเดือนก่อน +1

    I need advice about the REX-C100 and the tube heater, what kind of SSR relay should I put?
    Neither SSR40VA nor SSR40DA work for me.😢 How can I contact you privately?

    • @CNCEVOLUTION
      @CNCEVOLUTION  3 หลายเดือนก่อน +1

      it all depends on the cartridge heater you have, usually those with low voltage of 12 and 24 volts are connected to dc, so an ssr-40dd relay is good. if the cartridge heater has 120 or 220 v, it is usually ac and therefore a ssr-40da relay is good, but in this equation it also matters what kind of output the thermoregulator has in my case rex-c100 f k 02 - v * an dn, letter v it means that it has an output for the ssr relay. other letters mean that the thermoregulator has a different output.

    • @Tadek5
      @Tadek5 3 หลายเดือนก่อน

      @@CNCEVOLUTION Hello. I have REX C100 , without inscription SSR between electrical terminals 3 and 4. Can I connect This REX C100 to SSR ? That is, I want to connect the electrical system as shown in this video. The only difference is that there is no SSR inscription on my controller.

    • @CNCEVOLUTION
      @CNCEVOLUTION  3 หลายเดือนก่อน

      @@Tadek5 rex c100 has a code on the side label as in this link. the letter V indicates that it has an output for ssr and it connects to terminals 4+ and 5- www.aliexpress.com/item/1005004495865211.html?spm=a2g0o.productlist.main.11.115f20ccml4pN3&algo_pvid=38bea948-d045-47ca-9f0b-264aae91c5ac&algo_exp_id=38bea948-d045-47ca-9f0b-264aae91c5ac-5&pdp_npi=4%40dis%21RON%2125.43%2125.43%21%21%215.48%215.48%21%402101df0e17099746084551546e30e8%2112000029360963310%21sea%21RO%211703831701%21&curPageLogUid=4SyLgS9XvEDx&utparam-url=scene%3Asearch%7Cquery_from%3A

    • @Tadek5
      @Tadek5 3 หลายเดือนก่อน

      @@CNCEVOLUTION thank you. On my REX C100, on right side there is : output - RELAY. My question is: if something can go wrong if I connect my REX to SRR properly as on this video. I Have heater 230-5 A but this rex allow only 3 A. So I want to use terminals 4 and 5 as a controll voltage.

    • @CNCEVOLUTION
      @CNCEVOLUTION  3 หลายเดือนก่อน

      @@Tadek5 facebook.com/groups/661991900940461/ add photo with your rex c100 at this group

  • @incubadorasranyar7263
    @incubadorasranyar7263 3 ปีที่แล้ว +1

    Its necesary conect ssr?

  • @nimnem5249
    @nimnem5249 ปีที่แล้ว +1

    Can you tell me, how many watts of heater band?

    • @CNCEVOLUTION
      @CNCEVOLUTION  ปีที่แล้ว +1

      voltage and watts are limited by the relay you use. it is best to choose the relay according to the heating band you have

    • @nimnem5249
      @nimnem5249 ปีที่แล้ว +1

      @@CNCEVOLUTION many thanks 🥰👍

  • @NicuProiecteH
    @NicuProiecteH 5 ปีที่แล้ว +1

    Atenție ! Această schemă nu funcționează, deoarece acel SSR trebuie alimentat cu o tensiune,între 3v și 32 v. maxim, pinul 4 și pinul 5 de la REX-C100, au contact normal deschis,doar această funcție si trebuie alimentat cu o tensiune pentru a funcționa acel modul SSD. Cu stimă Nicu!

    • @CNCEVOLUTION
      @CNCEVOLUTION  5 ปีที่แล้ว

      Este functionala, o am pe extruderul meu, SSR ul primeste tensiune de la REX-C100.

    • @NicuProiecteH
      @NicuProiecteH 5 ปีที่แล้ว +1

      Scuze da ai dreptate Rex-C700 ,are releu cu contacte separate.

    • @CNCEVOLUTION
      @CNCEVOLUTION  5 ปีที่แล้ว

      Probabil te referi la cele japoneze, asta al meu este o copie chinezeasca si probabil nu au multe in comun cu originalele.

  • @ousmanekone7018
    @ousmanekone7018 3 ปีที่แล้ว +1

    And for c700

  • @nimnem5759
    @nimnem5759 3 ปีที่แล้ว +1

    I don't understand where can I connect to the ground!

    • @CNCEVOLUTION
      @CNCEVOLUTION  3 ปีที่แล้ว

      It depends on the type of machine built. In this case, the heating strips come in direct contact with the metal part of the machine, so it is enough to connect the earthing wire to the machine housing, more precisely to the metal part. What machinery do you build?

    • @nimnem5759
      @nimnem5759 3 ปีที่แล้ว

      Many thanks, I want to build injection molding machine.

  • @NicuProiecteH
    @NicuProiecteH 5 ปีที่แล้ว +1

    Da întradevăr se vede că nu este de origine .

    • @siongnimincoulibaly
      @siongnimincoulibaly 3 ปีที่แล้ว +1

      Salut, svp montrer moi le même câblage avec le XMTD 3001

  • @kizunakami2887
    @kizunakami2887 4 ปีที่แล้ว +1

    Why don't you actually perform this?