Hello Hope you are doing well, I just had a doubt regarding revit lookup tables When I do the manage lookup table it say that “The separator in the header is invalid. The acceptable separators are ,;: Can you help me out with this problem Thanks
Hi Saikumar Kurra, Yes we are doing good. Thanks for that. Hope you as well. Please check the excel sheet the first column is free from text. Second check you have saved the file as comma delimitated file. If its not clear mail me.
@@BIMModeller hello I did like you told me to do but still it says the same. But here at first I should do export then after I should import the file, but the main problem is I can’t export the file. Please help me with that!!! Thank you 😊
What if you do not want to have a default formula in the default space? What if you want to prompt the user to choose a different size if it isn't in the table? Is there an fprint to print an error function? "size_lookup(LookUp Table, "AOverall", ______ , Pipe Size)
I understand what you are asking. There is no workaround for this. If you are not giving the value automatically Revit will show up error. Based on that error we can create addin to show what was it. or People usually have Parameter named "Status" of the fittings once its placed. Based on that if size not matches It will show error.
I watch this vid and the older one, I also used 2018 and 2020 for this tutorial, but everytime i input "size_lookup(Lookup Table, "FID", Nominal Diameter -1 mm, Nominal Diameter)" I always get an "INVALID INPUT" error. :( Im so frustrated right now even i follow everything :(
Hi Guilbert Victa. Don't get frustrated. If you did one fitting then others will be easy piece. Check whether you have Look up table parameter and Nominal diameter parameter
All Revit Family Creation Tutorial Playlist
th-cam.com/play/PLM7hlfS3Tn5h1lqNmfvy_JbjgH3Vr71Jo.html
Subscribe TH-cam and Support
th-cam.com/users/BIMModellerdotcom
Thanks for the video.. You have really amazing content, and you took the time to explain things properly.. Really nice
Thank you Seyi O
Very good video and presentation. Thanks.
Thank you so much
Very informative. But please do the same for pipe elbow as well. Thanks
I'm glad. Do share it with your learning friends on LinkedIn.
For pipe elbow there is a new video did you checked?
Hello
Hope you are doing well,
I just had a doubt regarding revit lookup tables
When I do the manage lookup table it say that “The separator in the header is invalid. The acceptable separators are ,;:
Can you help me out with this problem
Thanks
Hi Saikumar Kurra, Yes we are doing good. Thanks for that. Hope you as well. Please check the excel sheet the first column is free from text. Second check you have saved the file as comma delimitated file. If its not clear mail me.
Can you please send me your mail I’d ??
Thank you
@@saikumarkurra375 rajkumar.nallusamy@bimmodeller.com
@@BIMModeller hello
I did like you told me to do but still it says the same. But here at first I should do export then after I should import the file, but the main problem is I can’t export the file. Please help me with that!!!
Thank you 😊
What if you do not want to have a default formula in the default space? What if you want to prompt the user to choose a different size if it isn't in the table? Is there an fprint to print an error function? "size_lookup(LookUp Table, "AOverall", ______ , Pipe Size)
I understand what you are asking. There is no workaround for this. If you are not giving the value automatically Revit will show up error. Based on that error we can create addin to show what was it. or People usually have Parameter named "Status" of the fittings once its placed. Based on that if size not matches It will show error.
nice video , thanks
Thank you @SamirAmmarcha
How come there is no FOD or FID for inches in the default look up tables?
You can Use imperial or metric Unit.
i have revit 2018 and i have no "manage lookup tabel" options. even i have no "family types" option
Hi Kenan. It's strange. Can you send me the snap so that I can see it Rajkumar.nallusamy@bimmodeller.com
I watch this vid and the older one, I also used 2018 and 2020 for this tutorial, but everytime i input "size_lookup(Lookup Table, "FID", Nominal Diameter -1 mm, Nominal Diameter)" I always get an "INVALID INPUT" error. :( Im so frustrated right now even i follow everything :(
Hi Guilbert Victa. Don't get frustrated. If you did one fitting then others will be easy piece. Check whether you have Look up table parameter and Nominal diameter parameter
the videos did not have sound
Hi This video must have sound.