Sir mujhe DC amp. meter Chahiye. Mere pas 100Amp. 75mv. Ka shunt or 3 digit ka amp meter hai Jo charging me negative polirity nhi batata. DC amp.Meter Kaha se purchase kare
Very helpful video, Thank you Sir. But One can connect the shunt in Positive wire also, and microcontroller will not Burnt as its own power supply is isolated. Microcontroller consider shunt potential voltage only.
Thanks for comment But the ground is common for whole circuit including microcontroller And any supply is w r t ground can demage device, I think so may be wrong, Thanks again
Aaj bahut sikheliya sir ji aab taak jo doubt hai clear hogai sir ji aap ko bahut dhanyvad sir ji. Sir ji inverter me shunt lagati haina sir ji vusiko bhi samajayiye sir ji role kya hoti hai inverter me
Sir you did an amazing job highly appreciate very well explain. Can you tell me what is mean by FL 19, FL 19B, FL 2C etc etc while buying DC shunt? what does that mean?
Sir ji me aap ke video ko dekhta hu aap kisi bhi circuit ko very easy karke samja dete hai thxxxxxxx kya aap ek help kar skte hai ek circuit banane me 60v DC to 12v and 5v DC , circuit me tino voltage use karni hai circuit heat problem bhi face na kare
माननीय वीडियो बहुत अच्छा लगा ❤ मेरी समस्या भी वर्तमान में इसी से रिलेटेड चल रही है, मेरे पास ELAK MK 2 AUTO ELECTRICAL TEST BENCH है, सरकारी नौकरी में हूं।बेंच पर मुख्य रूप से १२ एवं २४पावर सप्लाई, डिजिटल वोल्ट एवं एम्पियर मीटर लगे हैं तथा चार प्रकार के लोड लगे हैं वायरिंग पूरी डिस्टर्ब है। कुछ मदद कर सकें तो बतायें
Sir, apne kaha hai ki yadi shunt ko battery ke negative par na lagakar battery ke positive par lagayenge to is dpm ke analog circuit par with respect to ground 12 volt banega ,ye kaise ? kyonki shunt positive side lagayein ya negative side voltage drop across shunt 75 mv hoga.
Sir axiom e rickshaw 48V charger ka 3525 ic ka 9no. PIN me 0.2 volt nehi aaraha hai iska Kya solution hai (Problem is 30% charging led blinking fan is off)
Sir ak video pls pfc section p bno or ak pls amplify ic jitni b hoti h 358 lm 324 or or al video ki puri details ipm modul pls request h sir isko seekhane k liye log bhout pese mang rhe h
Dear sir mai multispan ka vaw 34 dc digital amp + voltmeter ke saath 200 amp75mv ka shunt use kar raha hu .......jab mai inverter ko backup load par chalata hu ok amp show karta hai but charging mode mai amp show nahi karta hai agar mai shunt wire inter change karta hu tabcharging amp show karta hai lekin backup par amp show nahi karta hai
Sir tv ma audio ic tda 7297 ka muting system details ma batayen. Ye sound ic LG tv , Samsung tv ar kuch local tv par bhi dekha jata hai. Mute transistor open karne par sound aa jata hai jabki mute transistor laga dene par sound nahi aata hai.bahut kosis kiya par original sound system repair nahi ho pata hai.jabki sub kuch theek hai.to problem kahan sa hota hai. Arbind Kumar Mandal. Dumka. Jharkhand.
Sir ye dc meter hmare Aligarh,Uttar Pradesh ke marcket me to mil hi nhi rha...sir ap online bhej sakte he kya... mujhe bhi testing board banana he apni shoap ke liye...
Sir Plz app kisi b normal inverter me grid charge enable disable siwich lga kr bataiye.. Ta k jo solar SMU k sath normal inverter jod kr jo sb se yada problem ati hai k rat mai inverter khud se battery charge krne lgta hai us se bcha ja ske..user apne hisab se grid charge enable disable kr ske... Plz sir ispe work kr k btaiye.. Je bht logo ke km aii ga... Mai b is se bht preshan hu...
Sir Sukam Falcon + singal battery sinewave inverter mein charging led blinking stop hone ke bawjood battery charge hota rehta hai jisse battery hit ho jati hai.. Please solve kijiye mere is problem को..
Sar ji ap sukam sine wave smiley 1400 main chargin fal aa rahi hai siresg bulb bhot hi jal raha hai main dane par kuch bata do sar kya program ho sakti hai ap ki bhot abhari rahenge sar
@@TotalPowerSolution sir mare pass pwm solar inverter h 50 amper change controlr vala 24v ka sir jab solar se 50 amper ate h tab both jeada amper se charg karta h Sir kush aisa jugad batae k battery ko 18 amper se jeada nahe Jane de
Bhut hi behatrin sir ji 🙏🙏 Sir ji 60 amp 75 mv drop Aap 6 amp pe 7.5 mv multimeter mein accurate show krega kya sir ji Sir ji charging mein positive symbol Aur discharging pe negative nhi hota kya ??
Aap ka video bahut he kaam ka Ho ta he sir today 2 3 video dekhta hu aur kaafi kuch sikha hu
Pawan sir really aap ke tarah itna depth knowledge maine youtube main really pahele kabhi nahi dekha
Very nice explanation,👌👌mere pass to time.hi ni hai channel banaane kaa very good keep going on God bless you
My pleasure
Keep watching
Total Power Solution
Very useful information on shunt resistance. Thank you very much. Good night 🙏
Always welcome
काश ऐसे गुरुजी पहले मिले होते।
My pleasure
Gud night
@@TotalPowerSolution good night sir
I work from 35 years electronics work but I like you
Bahut hee aacchea se samjhatea hai Aap
Aapke video bahut helpful hote hai . Thankyou very much,
Thanks
बहुत अच्छी तरह से समझाया है सर आपने ।👍
Sir ji bhot acha aap na smjaay good 👍
Thanks
पुरे जमिंपे आकर समझाया गया...thanks sir ji....
आपका आशीर्वाद बना रहे
@@TotalPowerSolutionthanks...
This is really very good sir Thanks you so much sir
Sir mujhe DC amp. meter Chahiye. Mere pas 100Amp. 75mv. Ka shunt or 3 digit ka amp meter hai Jo charging me negative polirity nhi batata. DC amp.Meter Kaha se purchase kare
Very helpful bhai to me.tq so much bro.
Always welcome
Very good sir , bahut hi badiya jankari
Lajawab ho sirji ap
Thanks
Very helpful video, Thank you Sir.
But One can connect the shunt in
Positive wire also, and microcontroller
will not Burnt as its own power supply
is isolated.
Microcontroller consider shunt
potential voltage only.
Thanks for comment
But the ground is common for whole circuit including microcontroller
And any supply is w r t ground can demage device, I think so may be wrong,
Thanks again
aapke vidio kafi jankari dete hai
thanks sir ji
Good tiching karte hai 👍👌👌👌👌👌👌👌👍👍👍👍👍👍👍
Good morning sir.video is best se bhi best
Thanks
Aaj bahut sikheliya sir ji aab taak jo doubt hai clear hogai sir ji aap ko bahut dhanyvad sir ji. Sir ji inverter me shunt lagati haina sir ji vusiko bhi samajayiye sir ji role kya hoti hai inverter me
boht khob, jeo bhai....
Thanks
Nice video sir thanks for sharing your information with us thank you so much
Most important digital meter constion thanks sirji 👍
Very good video sr 👍 👏 👌
Excellent. One correction at 30 Amps load corresponding mV will be 37.5.
Thanks
Yes
Thanks
Very very nice video thank you sir ji 🙏🌹👌👏👍
Always welcome
Very good and useful, lot of thanks.
Always welcome
Sir you did an amazing job highly appreciate very well explain. Can you tell me what is mean by FL 19, FL 19B, FL 2C etc etc while buying DC shunt? what does that mean?
👍 best information given sir, salut boss
Nice video sir
Thanks
Gud night
Thankyou for your excellent explain bhaiya
Thanks for your valuable like and comment
Nice video 👌 sar ji
Thanks
Sar is ki microcontrol ka program nikal na ho to sar
Thankyu pawan sir
👌👌👌... awosome.....lajavab
Thanks
Gud night
You are great sir you have solved my all doughts
Sir ji me aap ke video ko dekhta hu aap kisi bhi circuit ko very easy karke samja dete hai thxxxxxxx kya aap ek help kar skte hai ek circuit banane me 60v DC to 12v and 5v DC , circuit me tino voltage use karni hai circuit heat problem bhi face na kare
Very nice information sir thanks
Thanks
Nice sir जी
Thanks
Super sir ji
Thanks
Very nice helpful sir
Thanks
Very nice sir amazing👍👍👍
Thanks
Gud night
@@TotalPowerSolution gud nyt sir
माननीय वीडियो बहुत अच्छा लगा ❤ मेरी समस्या भी वर्तमान में इसी से रिलेटेड चल रही है, मेरे पास ELAK MK 2 AUTO ELECTRICAL TEST BENCH है, सरकारी नौकरी में हूं।बेंच पर मुख्य रूप से १२ एवं २४पावर सप्लाई, डिजिटल वोल्ट एवं एम्पियर मीटर लगे हैं तथा चार प्रकार के लोड लगे हैं वायरिंग पूरी डिस्टर्ब है। कुछ मदद कर सकें तो बतायें
Pl solve my problem/request
Very well explained.
Thank
Kalandar sir
Sir nice video
Your are great sir
Thanks
Sir I need to learn about cro.
I wii
Nice sir
Thanks
Sir, apne kaha hai ki yadi shunt ko battery ke negative par na lagakar battery ke positive par lagayenge to is dpm ke analog circuit par with respect to ground 12 volt banega ,ye kaise ? kyonki shunt positive side lagayein ya negative side voltage drop across shunt 75 mv hoga.
Excellent explanation
Well done sir
Sir axiom e rickshaw 48V charger ka 3525 ic ka 9no. PIN me 0.2 volt nehi aaraha hai iska Kya solution hai
(Problem is 30% charging led blinking fan is off)
Sir. Apke inverter testing bord me lage DPM DC amp miter kitane amp ka hai.
Aur DPM DC volt miter kitane volt ka hai.
Sir isaki price kitane ka hoga.
Excellent Explanation
Thanks thanks thanks very much sir
Best sir
Great job
Thank you
Always welcome
Waa bahot kam ka cicuit hai ye.
Nice video
You are greatly welcome 🙏
Sir ak video pls pfc section p bno or ak pls amplify ic jitni b hoti h 358 lm 324 or or al video ki puri details ipm modul pls request h sir isko seekhane k liye log bhout pese mang rhe h
Battery lead size or length ke upper bi ek video banaye please
Ok
Soon
Sire hum guwahati se.kaise he aap.meri torof se aap kou happy bihu.
Aapko bhi
Thanks sir
Always welcome
V good video
My inverter is Luminous Bravo 675.
It is charging continuously battery is getting heatedup what iis the problem
Excellent
Analog meter pe shunt ke uses pe bhi video bnaye
मस्त
Thanks
Bhai su kam 650va inverter ka ic program tumari taraf milega kya?
Sir kia is ko inverter pr permanent lga skte hai or 500 watt inverter pr battery lead kitne mm ki or kitni lmbi accurate hai ji
Dear sir mai multispan ka vaw 34 dc digital amp + voltmeter ke saath 200 amp75mv ka shunt use kar raha hu .......jab mai inverter ko backup load par chalata hu ok amp show karta hai but charging mode mai amp show nahi karta hai agar mai shunt wire inter change karta hu tabcharging amp show karta hai lekin backup par amp show nahi karta hai
Grate information Sir
Sir Kya inverter me bhi shunt resistor ka use hota h
Sir tv ma audio ic tda 7297 ka muting system details ma batayen. Ye sound ic LG tv , Samsung tv ar kuch local tv par bhi dekha jata hai. Mute transistor open karne par sound aa jata hai jabki mute transistor laga dene par sound nahi aata hai.bahut kosis kiya par original sound system repair nahi ho pata hai.jabki sub kuch theek hai.to problem kahan sa hota hai. Arbind Kumar Mandal. Dumka. Jharkhand.
Hi sir bus me itna hi kahunga jese gayak Mohammad Rafi Sahab ka koi jawab nhi bese hi apka koi jawab nhi
Thanks for your valuable like and comment
Sir ye dc meter hmare Aligarh,Uttar Pradesh ke marcket me to mil hi nhi rha...sir ap online bhej sakte he kya... mujhe bhi testing board banana he apni shoap ke liye...
9.99amp.tak mapne wale digital ampere meter se 20 ya 30 amp. mapna ho to kya shunt lagaakar kiya ja sakta hai sir ji. Yadi ha to kaise.
Sir
Plz app kisi b normal inverter me grid charge enable disable siwich lga kr bataiye..
Ta k jo solar SMU k sath normal inverter jod kr jo sb se yada problem ati hai k rat mai inverter khud se battery charge krne lgta hai us se bcha ja ske..user apne hisab se grid charge enable disable kr ske...
Plz sir ispe work kr k btaiye.. Je bht logo ke km aii ga... Mai b is se bht preshan hu...
Nice
Thanks
Sir Sukam Falcon + singal battery sinewave inverter mein charging led blinking stop hone ke bawjood battery charge hota rehta hai jisse battery hit ho jati hai.. Please solve kijiye mere is problem को..
Sir ye dono samaan hamare yahan nahi milte hai
Pavan bhai mico ke 26 no per 2 v nhi aaye to kya chek karna chahiye
Thank you very much sir
Ok sir
Thanks keep watching
Total Power Solution
Sar ji ap sukam sine wave smiley 1400 main chargin fal aa rahi hai siresg bulb bhot hi jal raha hai main dane par kuch bata do sar kya program ho sakti hai ap ki bhot abhari rahenge sar
Thank you 👍
Always welcome
Very nice👍👍👍👍👍
Nice 🙏
Pls explain us sir what is the use of analog and digital pin use in control ic..🙏
100 amp/54v charger , in make current limit 80 amp , we use tips??
Shunt value depending?
Hello 👋 sir sir kush aisa jugad batae jese laga kar hum battery ko 15 ja 18 amper se jeada charge na hone pae
Ok
@@TotalPowerSolution sir mare pass pwm solar inverter h 50 amper change controlr vala 24v ka sir jab solar se 50 amper ate h tab both jeada amper se charg karta h Sir kush aisa jugad batae k battery ko 18 amper se jeada nahe Jane de
Sir generator avr repairing par video banane ki kripa kare
Ok
Bhut hi behatrin sir ji 🙏🙏
Sir ji
60 amp 75 mv drop
Aap 6 amp pe 7.5 mv multimeter mein accurate show krega kya sir ji
Sir ji charging mein positive symbol
Aur discharging pe negative nhi hota kya ??
Kuch multimeter ka error ho sakta hai use less karna padega
Polarity ke liye aap interchange kar sakyein hain
Thanks
@@TotalPowerSolution sir ji 🙏🙏
Analog ampere meter pe AC/dc likha hota h kisi kisi pe
Kya hm dc ampere bhi check ke skte h kya usse
Brother ji, analog meter per bi shunt lagana padta hai,
Sir kya ap is meter ko curior se bhej shaktein hai. Shunt k sath. Mujhe iski zarurat hai. Replied please sir.
Thanks sir…........
Always welcome
Sar yah kaun si company ka hai Ek hamen bhi lena hai jo plus minus show Karen ab market Mein plus minus wale Nahin Mil Rahe Hain
Good luck
Thanks
Keep watching
Total Power Solution
Tq sir
Sir hmm jharkhand sa hi mere ko suntrajestan nahi mil raha hai kaha sa Mila ga sir ??