Preparing Tris Buffer

แชร์
ฝัง
  • เผยแพร่เมื่อ 20 ต.ค. 2024

ความคิดเห็น • 42

  • @ZulhilmiHusni
    @ZulhilmiHusni 11 ปีที่แล้ว +8

    Did you know that TRIS will form precipitate with Ag+ in conventional pH meter electrode?
    One does not simply measure TRIS buffer in pH meter with Ag/AgCl electrode with single junction reference electrode (mostly used in conventional pH meter now days) because it will poisons the reference electrode.
    using calomel electrode or double junction reference electrode is the correct way
    it seems that your using single junction electrode (i can see it clearly) and therefore your actual pH in not 7.8.

  • @nathancoleman8648
    @nathancoleman8648 ปีที่แล้ว

    Great video, very helpful, but I think your N on the NaOH bottle is backwards.

  • @DocScoop7
    @DocScoop7 ปีที่แล้ว +2

    no calculations mentioned, how do we know we need to add 15.14g of powder? where does it come from

  • @onnorokom2023
    @onnorokom2023 5 ปีที่แล้ว +4

    The use of single-junction pH electrodes that contain silver should be avoided when determining the pH of a solution containing Tris buffer

  • @the-spiritual-thoughts
    @the-spiritual-thoughts ปีที่แล้ว

    Why we only use HCl and not any other acid for stabilizing ph please answer

  • @dmadhav4867
    @dmadhav4867 ปีที่แล้ว

    how can we know to add 15.4g of tris buffer in sample water

  • @aminaferielkadri1248
    @aminaferielkadri1248 2 ปีที่แล้ว

    can you make a video about how to prepare lysis buffer

  • @bbmeesci5950
    @bbmeesci5950 6 ปีที่แล้ว +3

    I had no idea that you could add HCl to your buffer to alter the PH. my mind is blown.

    • @sasidharankr2344
      @sasidharankr2344 5 ปีที่แล้ว

      Yes you r rite..it should not be done so

    • @WeezyGR
      @WeezyGR 3 หลายเดือนก่อน

      this is the correct way, what do you suggest​@@sasidharankr2344

  • @coca833
    @coca833 11 ปีที่แล้ว +2

    I have a question, if I want to prepare a solution at a concentration of 100 mM pH: 7.8 from this solution(0.5M, pH:7.8), I have to re-measure your pH? Thanks for you video.

  • @erygusman4557
    @erygusman4557 2 ปีที่แล้ว +1

    Thank you for the Video, it's really helpful. What we put instead of HCl to increase our pH Buffer solution?, for example if my buffer pH is 8,5 but I want it pH at 9.0

  • @NOURALB_24
    @NOURALB_24 3 ปีที่แล้ว

    Why we didnt use boric acid?

  • @XxXnonameAsDXxX
    @XxXnonameAsDXxX 3 ปีที่แล้ว

    When i add the tris my solution becomes cloudy. I have to adjust the pH with hcl. Only after it will be clear again. I'm using 1 g/l of tris(THAM). Is this normal?

  • @medineadin4700
    @medineadin4700 6 ปีที่แล้ว

    Thank you it helped me a lot !

  • @nahlaalshaikh581
    @nahlaalshaikh581 10 ปีที่แล้ว +2

    Good video

  • @monsabas5771
    @monsabas5771 9 ปีที่แล้ว

    good video ,,thanks alot,,, but can you help me about the best buffer that can be used in my experiment when my drug is unstable at phosphate buffer,,,, means that when i prepared the phosphate buffer the uv absorbance was not stable that changed with time but i need the same absorbance for 14 days !!!! so what the solution ?? plz help me :((

  • @larissabts6638
    @larissabts6638 3 ปีที่แล้ว

    So amazing 💗💗💗

  • @ryanpersaud95
    @ryanpersaud95 5 ปีที่แล้ว

    Very helpful thank you

  • @maryambibiabdullatifzargar6521
    @maryambibiabdullatifzargar6521 5 ปีที่แล้ว

    how to prepare 10mM tris buffer needed for DNA extraction??

  • @wardahmustahsan888
    @wardahmustahsan888 8 ปีที่แล้ว

    can you do a video on CTAB buffer?

  • @khuntalhashah6433
    @khuntalhashah6433 7 ปีที่แล้ว

    can you please upload some video on kreb henseleit buffer?

  • @muhammadfarazali4251
    @muhammadfarazali4251 6 ปีที่แล้ว

    Which powder u have used?

  • @kailed
    @kailed 4 ปีที่แล้ว

    does it work with amylase?

  • @bhupendrabhatta5850
    @bhupendrabhatta5850 ปีที่แล้ว +1

    What is the temperature and time for autoclaving?

  • @msr9452
    @msr9452 4 ปีที่แล้ว

    Great 👍

  • @mariadeassis5484
    @mariadeassis5484 2 ปีที่แล้ว

    Olá...muito legal.

  • @HamburgoYT
    @HamburgoYT 7 ปีที่แล้ว +1

    Aren't ph meter bars aren't as accurate as ph paper?

    • @joeriv5462
      @joeriv5462 7 ปีที่แล้ว +1

      You switched it. pH paper is not as accurate as pH meters

    • @HamburgoYT
      @HamburgoYT 7 ปีที่แล้ว

      joeriv5462 That's weird?!! In our biotech lab they prefer us using ph paper and said it was accurate. I think its because its faster...

    • @joeriv5462
      @joeriv5462 7 ปีที่แล้ว +1

      Hamburgo pH paper can be faster since all you have to do is insert it into your solution and look for color change. pH meters are quantitative so you can determine the exact pH of your solution.

    • @HamburgoYT
      @HamburgoYT 7 ปีที่แล้ว

      joeriv5462 Sweet! Really appreciate it :D

    • @babubassa8434
      @babubassa8434 7 ปีที่แล้ว

      No. They cannot be.

  • @darklight1030
    @darklight1030 5 ปีที่แล้ว

    what!? I dont even know if I should autoclave or filter!

    • @brnkaik
      @brnkaik 4 ปีที่แล้ว

      me neither

  • @deryacelik7743
    @deryacelik7743 4 ปีที่แล้ว

    tnks to video

  • @maryambibiabdullatifzargar6521
    @maryambibiabdullatifzargar6521 5 ปีที่แล้ว

    great

  • @leewilliam3417
    @leewilliam3417 ปีที่แล้ว

    Mmmmnn😊

  • @martinez3499
    @martinez3499 3 ปีที่แล้ว

    I'm spiderman

  • @TheAquaventures
    @TheAquaventures 6 ปีที่แล้ว

    0:58 do NOT stick your scoopula directly into a reagent bottle!