How to Hipot Test

แชร์
ฝัง
  • เผยแพร่เมื่อ 24 พ.ย. 2024

ความคิดเห็น • 59

  • @lexvanheel
    @lexvanheel 2 ปีที่แล้ว +2

    Very good explanation of HiPot testing! Thanks for making this available.

  • @MarcoMoreno5757
    @MarcoMoreno5757 4 ปีที่แล้ว +3

    Thank you for sharing. Now I know the basics for Hipot Test.

  • @KIlango-x9j
    @KIlango-x9j ปีที่แล้ว

    Very simple video to know the hipot test. Thanks for the video. He is saying micro amps instead of milli amps.

  • @anthonyheak3479
    @anthonyheak3479 หลายเดือนก่อน

    Great explanation on the hi-pot test. Wish your microphone was a little louder, but anyway great job!

  • @Graham_Wideman
    @Graham_Wideman 2 ปีที่แล้ว +1

    2:55 and following -- the electron flow direction is drawn and described backwards. If the line/neutral circuit is attached to a positive voltage, and there is leakage to the grounded case, then there will be a positive current in the direction from the circuit to the case. A positive current, in this situation, is composed of the negative charges carried by electrons flowing in the opposite direction. Or to put it another way, the positive voltage on the circuit corresponds to a _deficit_ of electrons, and when that deficit is sufficient (high enough voltage), then electrons will be attracted from the case.

  • @Nobel0
    @Nobel0 4 ปีที่แล้ว +2

    Thank you sir for the video it really help knowing what is hipot test,, as i am a mechanic i have no clue what was this ^^ Thanks again

  • @胡二-w9v
    @胡二-w9v ปีที่แล้ว

    6:09 Great video! I wander if the leakage is 19mA, so we can say that the product pass the test? Another word, can I raise the break down current value to 50mA?
    And, if I test different reels of cable, different length has different value on same cable.

  • @MountainsAndCycling
    @MountainsAndCycling ปีที่แล้ว

    Really good explanation. Congratulations!

  • @madhan5923
    @madhan5923 11 วันที่ผ่านมา

    What if we have product with plastic body and where we can connect the ground?

  • @NightbladeNotty
    @NightbladeNotty หลายเดือนก่อน

    So you are testing the integrity of the insulation, rather than the circuit itself?

  • @fawzih.4610
    @fawzih.4610 2 ปีที่แล้ว +1

    Great video! Will have an audit next week and this helped a lot. Thank you very much.

  • @SanjaySharma-rc5sc
    @SanjaySharma-rc5sc 3 ปีที่แล้ว

    You should tell that how we decided high pot test volt to different equipments👍👍👍

  • @thomaskauffman9886
    @thomaskauffman9886 5 ปีที่แล้ว +4

    Good video, but I can't use it because when you run the test you fail to use the provided guards for your test equipment. Safety is crucial in our training. Thanks

    • @stickboyfpv4742
      @stickboyfpv4742 4 ปีที่แล้ว

      They aren't provided! they cost extra! And you could just implement them and still do it this way..

    • @Dvalle53
      @Dvalle53 4 ปีที่แล้ว

      Safety is number 1 that is a given. Take the video for the good info.... he made a really good video . Hold your criticism

    • @thomaskauffman9886
      @thomaskauffman9886 4 ปีที่แล้ว +1

      David Valle, if safety is #1 and is a “given”, then why is it that so many electronic engineers and testing technicians get shocked every year, and in some cases they end up in the hospital?
      I didn’t criticize the content, in fact I recognized that it’s a good video, but when trainees see the trainer bypassing or avoiding safety devices (without a clear disclaimer) they figure they can do the same.
      It’s dangerous to think that safety is a given, processes such as this need to be poke-yoked. I have had to sit in front of OSHA and explain where our training, supervision and lack of safety devices failed to protect a seasoned and very experienced UL testing technician and what we were going to do differently to prevent from having another shock injury.
      Oh, and please don’t be so thin skinned when it comes to criticism

    • @justinjuhan1635
      @justinjuhan1635 3 ปีที่แล้ว

      Did he make the video for your commercial use?

    • @michaellapierre1244
      @michaellapierre1244 3 ปีที่แล้ว +2

      Is the argument that safety barriers should be in place during the hipot test to prevent someone from making contact with the UUT (unit under test)? Are you saying the hipot test can make the grounded metal of the UUT live at a high voltage if the dialectic is not sufficient? I ask because someone told me to press start on a hipot tester while he rested his arms on the enclosure. I refused and he got irritated. It was a 2200 volt test of a UL 508 enclosure. Thanks

  • @w_yew
    @w_yew 2 ปีที่แล้ว

    Hi, why do we disconnect all the neutral conductor in the switchboard when we do hipot test?

  • @bobbauvian7700
    @bobbauvian7700 2 ปีที่แล้ว +1

    what is the difference on a hipot test and a megger test when it comes to motor winding?

    • @30mAkills
      @30mAkills 2 ปีที่แล้ว

      Meggering = insulation integrity. Non destructive.
      Hi pot = Insulation breakdown or dielectric withstand strength. This can be destructive or non destructive.

  • @helendu5241
    @helendu5241 3 ปีที่แล้ว

    Do you need to remove the cable from SWGR before the cable test? What are the cons if the cable is connected on both ends of it

  • @nimishkhandelwal454
    @nimishkhandelwal454 ปีที่แล้ว

    Great explanation

  • @andrewsong1841
    @andrewsong1841 2 ปีที่แล้ว

    Hello I have a question what if we have 3pins, and test pin 1 to pin2 and pin1 to pin3, which one is going to be output lead?

  • @sasiprapachomthong8772
    @sasiprapachomthong8772 ปีที่แล้ว

    How to calculate resistance from the withstanding test, if I use 2.2 kV and I got 0.02 mA. Can I use V = IR?

  • @vaibhavgunjal8103
    @vaibhavgunjal8103 4 ปีที่แล้ว

    thank you for the informative video Sir,
    wanted to understand this test for 3phase motor as well.
    can you specify what should be the time and leakage current allowed for production test of a 3 phase motor rated for 110V AC.?

    • @michaellapierre1244
      @michaellapierre1244 3 ปีที่แล้ว

      It should be written in the electrical code the motors are meeting.

  • @dodolutopias
    @dodolutopias 4 ปีที่แล้ว

    Great content and explanation!

  • @trongkhiem4172
    @trongkhiem4172 4 ปีที่แล้ว

    I have question for a test tool.
    What value off current which can detected Pass or Fail?

  • @sachingiri9236
    @sachingiri9236 2 ปีที่แล้ว

    How can we do AC 6 KV di electric underwater test of piercing connector?

  • @_RnD_
    @_RnD_ 5 ปีที่แล้ว +1

    Thanks for the video. If we do Hipot test kind of computer's power supply, should we turn on its On/Off switch or leave it off?

    • @arhipotatassociatedresearc4958
      @arhipotatassociatedresearc4958 5 ปีที่แล้ว +1

      Thanks for your question Roman. We recommend the power switch of your DUT be in the ON position to close any contacts or relays. This allows the Hipot test to check the entire circuit for leakage. If your DUT is in the OFF position you may only be testing up to the power switch and fail to test the entire DUT as intended.

    • @restartlife407
      @restartlife407 5 ปีที่แล้ว +1

      You have to turn on the power supply switch because you have to allow electrons to pass through the switch to the circuit.

  • @minhnguyen-ig4my
    @minhnguyen-ig4my 2 ปีที่แล้ว

    Thank for your sharing

  • @KamranB1
    @KamranB1 2 ปีที่แล้ว

    Nice explanation !

  • @murrbuck3081
    @murrbuck3081 4 ปีที่แล้ว

    This was a great informative video. Thanks.

  • @sir7586
    @sir7586 5 ปีที่แล้ว

    Hello,
    A question: why hipot test lasts for a few seconds? what's going to happen if it last for a longer say 10 sec 1 min ?

  • @dillongere3322
    @dillongere3322 2 ปีที่แล้ว

    Great video thank you

  • @bobbauvian7700
    @bobbauvian7700 2 ปีที่แล้ว

    can hipot be used for testing leakage on capacitors?

  • @iqbalshahiran1490
    @iqbalshahiran1490 4 ปีที่แล้ว

    Can i know the procedure of hipot testing

  • @syntheticsol
    @syntheticsol 3 ปีที่แล้ว

    Nice one! Ty

  • @kostagrammatis6820
    @kostagrammatis6820 3 ปีที่แล้ว +2

    You frequently reference microamps (μA), but I believe you mean milliamps (mA) - which is what the screen of your device shows.

    • @thatonepanch
      @thatonepanch 3 ปีที่แล้ว +1

      1milliamp = 1000 microamps I believe. he just reads it in microamps. you are right the screen does display milliamps

  • @abdessamedghettas7167
    @abdessamedghettas7167 2 ปีที่แล้ว

    Thanks well explained

  • @sjamesking6605
    @sjamesking6605 3 ปีที่แล้ว

    Great job

  • @Ls-uv9cb
    @Ls-uv9cb 4 ปีที่แล้ว

    Very helpful, thank you.

  • @Kh-zf1kd
    @Kh-zf1kd 5 หลายเดือนก่อน

    gret video thank you.

  • @sohailjanjua123
    @sohailjanjua123 ปีที่แล้ว

    Hi, I like your video. Thanks

  • @vanhelsing3225
    @vanhelsing3225 5 ปีที่แล้ว

    Thanks for the video man...

  • @budi0251
    @budi0251 4 ปีที่แล้ว

    Can we do hipot test with standard insulation tester?
    Some can do up to 1kv, 5kv, even 10kv; granted they give result in mega/gigaohms but can you work out the current through ohm's law and we're already know the voltage?

    • @ajgio
      @ajgio 3 ปีที่แล้ว

      Hi-Pot testers can limit the maximum current and therefore not cause damage to the equipment when detecting it has bad insulation. Insulation resistance testers generally don't have the ability to control the current, therefore on higher voltages you can fry sensitive electronic equipment (if present). You may be able to repair the equipment insulation and keep using it when detecting it with a HI-POT, compared to if you IR test it on a higher voltage while you may detect faulty insulation, you have also probably destroyed the electronics if the current is able to flow across it.

  • @alairsilvajunior7814
    @alairsilvajunior7814 4 ปีที่แล้ว

    great video

  • @tamilselvantamilselvan6428
    @tamilselvantamilselvan6428 3 ปีที่แล้ว

    Thanks

  • @themonitoringgroup4956
    @themonitoringgroup4956 3 ปีที่แล้ว

    That’s check out Roy l clay he is the orginaj

  • @jorgebourdette4276
    @jorgebourdette4276 3 ปีที่แล้ว

    Nice video. But I think he is exposing too much, not safe. Shouldn't he close the lid, and make sure there is no voltage before touching anything?

  • @sanatghosh9278
    @sanatghosh9278 5 ปีที่แล้ว

    it is helpful

  • @Googlename699
    @Googlename699 6 หลายเดือนก่อน

    Good. I am engineeing from Iraq

  • @LupaKhali
    @LupaKhali ปีที่แล้ว

    Those are "milli" NOT "micro" amps