Aspen Plus: Simulation of a Chemical Looping Combustion System
ฝัง
- เผยแพร่เมื่อ 12 ก.ย. 2024
- Chemical-looping combustion (CLC) is a technology that creates an almost pure CO2 stream.
A CLC system typically consists of two parallel processes, the fuel reaction and the air reaction, each taking place in separate fluidized bed reactors.
A metal oxide is employed as the oxygen carrier (OC) to transport the oxygen from the air reactor to the fuel reactor.
Typical OC species include Fe2O3 / Fe3O4, CuO / Cu, Mn2O3 / Mn3O4, and NiO / Ni, which are either impregnated, extruded or freeze granulated into porous support particles composed of materials such as Al2O3, TiO2 or ZrO2.
In the fuel reactor, the oxygen carrier is used as the bed material, which is reduced by the fuel producing CO2 and H2O.
The reduced oxygen carrier is transported to the air reactor where it is reoxidized by atmospheric air and transferred back to the fuel reactor to complete the loop.
In this video, a CLC system will be simulated with Aspen Plus.
The energy source is goal.
Source: William X. Meng, Subhodeep Banerjee, Xiao Zhang, Ramesh K. Agarwal. Process simulation of multi-stage chemical-looping combustion using Aspen Plus. Energy. 90. 2015. DOI: 10.1016/j.energy.2015.06.139
All Aspen simulations in this channel can be downloaded for a donation. After completing the donation, you will be redirected to the download page:
www.paypal.com...
kg.engineering.solutions@gmail.com
can you make simulation of toluene from benzene and hydrogen?
is in the videos list
Hello sir, you make very useful content for chemical engineers. Could you please make video on biodiesel production from waste cooking oil using Aspen Plus?
Your content helps me a lot.
Hello, Thank you. I write the simulation on the list.
Can I modify shell and tube HX as a reactor in Aspen Plus?
Unfortunately I do not know
Hello sir, it was very useful video. I simulated it, but I found warning in property environment, which I attached here
WARNING IN PHYSICAL PROPERTY SYSTEM
PARAMETER DCPLS/ELEMENT 1 (DATA SET 1)
UPPER BOUND VIOLATED FOR COMPONENT COS
VALUE = 0.97606E+14, UPPER BOUND = 0.10000E+10
could you please help me to overcome this warning
You're welcome
maybe it's the Aspen Plus version?
thank you so much sir@@kgengineeringsolutions