  • The scope of this install made it quite the challenge, but it resulted in a huge system that's overproducing solar!
    Fun fact: we measured the trench and it ended up being 775 feet long!
    Get ARK Lithium battery storage:
    practicalprepp...
    Let's discuss your solar goals:
    practicalprepp...
    Get an EMP hardened DIY kit:
    practicalprepp...
    Order the Sol-Ark 15k inverter:
    bit.ly/3m7DGYZ
    Order the KB 450W solar panels:
    practicalprepp...
    Our pressure canners are back in stock and in fun new colors!
    bit.ly/3IdOgWJ
    Get an eBike:
    Join our Discord server!
    / discord
    Follow me!
    / practprepllc
    / engineer775
    / simplysustainabl. .
    / practicalpreppers

ความคิดเห็น • 66

  • @frumious2946
    @frumious2946 ปีที่แล้ว +3

    Great job as always, Scott. I'm still in awe of the retaining wall behind the pond. Very nice.

  • @awbean5254
    @awbean5254 ปีที่แล้ว +3

    SCOTT, CONGRATULATIONS TO YOU & YOUR TEAM ON ANOTHER GREAT DUAL SOL-ARK 15k JOB! 🎉

  • @AdamDeLayDIY
    @AdamDeLayDIY ปีที่แล้ว +1

    Thanks for the overview! I’ve gotten a lot of tips for my own install by watching!

  • @peterking1134
    @peterking1134 11 หลายเดือนก่อน +1

    Hopefully you charge for the disconnect and reconnect of all those dsl & cameras!

  • @iamkorbendallas
    @iamkorbendallas ปีที่แล้ว +2

    Incredible custom builds. You and your team are a talented group. Thank you for another great video!

  • @SolarSamOffGrid
    @SolarSamOffGrid ปีที่แล้ว

    That was an awesome look at a large residential set up. The video makes it seem so easy. I’m sure there were many challenges to get that customer up on going.
    Great job done

  • @Roll2Videos
    @Roll2Videos ปีที่แล้ว +1

    That is a thing of beauty! When I win a lottery I'll have you help me build out my property lol. Great work. 👍

  • @RJ-cc1fz
    @RJ-cc1fz ปีที่แล้ว

    What a job.. good thing you got good help. Hard for everyone to just relax and do it bit by bit

  • @willistisdale4293
    @willistisdale4293 ปีที่แล้ว +5

    I’d like to apologize for filming vertically

    • @simonpaine2347
      @simonpaine2347 ปีที่แล้ว +1

      No need to apologise. It was fine. Good clean, tidy work.

  • @BobZell
    @BobZell ปีที่แล้ว +7

    Huge project, great job! What was the array DC cable size you settled on for that crazy long run?

  • @loucinci3922
    @loucinci3922 ปีที่แล้ว +1

    Great job. looks fantastic

  • @CatCrazyFamily
    @CatCrazyFamily ปีที่แล้ว +1

    Artis at work. Beautiful work. Well more like amazing work!

  • @jeffmotes2129
    @jeffmotes2129 ปีที่แล้ว +1

    Another great video. Thanks!

  • @1rallod
    @1rallod ปีที่แล้ว +1

    Another awesome job!

  • @cereus57
    @cereus57 ปีที่แล้ว +1

    It certainly is awesome to have such great people working on these projects!

  • @MRNC
    @MRNC ปีที่แล้ว +1

    nice job! you guys are top notch.

  • @alessandroinacio424
    @alessandroinacio424 ปีที่แล้ว +1

    Very good.

  • @Sylvan_dB
    @Sylvan_dB ปีที่แล้ว +1

    Wow, that D.C. run is crazy. I hope it is high voltage D.C. otherwise I think maybe micro-inverters or a power shed at the panels and then 240v to the house would have been more economical. My house is surrounded by trees and I'm thinking of building a nice big garage 100-150 feet away over near where I can put some solar and then the garage will house my power system.

  • @user-kf5zw8uq7r
    @user-kf5zw8uq7r ปีที่แล้ว

    This guy knows what he's doing.

  • @Madactionmedia
    @Madactionmedia ปีที่แล้ว

    So awesome!

  • @Flowing23
    @Flowing23 ปีที่แล้ว

    good work 👍👍

  • @OscarGonzalez-ct6no
    @OscarGonzalez-ct6no ปีที่แล้ว +1

    hell yea brother!

  • @MrMoparMan
    @MrMoparMan 6 หลายเดือนก่อน

    Another great install, great job! I have a question about the dual bypass...Both are fed by the combined Load side of the Solarks, and then feed separate breaker panels. I imagine care must be taken when using bypass as not to feed grid to the load side of the Solark if only one is in bypass?

    • @peteryates7505
      @peteryates7505 5 หลายเดือนก่อน

      did you get an answer on this? I am looking at the same and understand i must use 200A downstream of each sol ark

  • @rocky7gd
    @rocky7gd ปีที่แล้ว +6

    What is the voltage drop and what is the gauge of those long cable runs?

  • @bradspaugh9827
    @bradspaugh9827 ปีที่แล้ว

    Chris is a wizard

    • @engineer775
      @engineer775  ปีที่แล้ว

      Yes, Chris has a lot of tricks up his sleeve.

  • @jdlutz1965
    @jdlutz1965 ปีที่แล้ว +3

    Just curious on all the specs with size of solar array and cost (ballpark is fine). With the amount of trenching, wire, complexity and such.... I'd guess around $200K?!

  • @peteryates7505
    @peteryates7505 6 หลายเดือนก่อน

    Nicw job...is this a parallel system design with combiners or 2 independent solark systems? I am looking at ding 2 independent for each of my 2 200A circuits.

  • @johnstone-gh9nj
    @johnstone-gh9nj ปีที่แล้ว +1

    Hello Scott,
    I contacted you some time ago about your TechLuck PV water controller. When it would be available again. Can you please tell me If you are producing It again. Jimginn from Ohio mentioned It being off market. Then he said It Is back on the market. Is It on the market or Is there problems with the design. Thanks.

  • @RaymondMatos7
    @RaymondMatos7 6 หลายเดือนก่อน

    Have some questions, for the grid in, are you bringing in 2 x 4/0 lines and then using a distribution block to join them, then going into the grid on the solark?
    For the load out from solark are you going out to another distribution block first then to each bypass switch?
    Any load shedding?

  • @simonpaine2347
    @simonpaine2347 ปีที่แล้ว

    I'm curious about the bypass wiring.
    I'm assuming that the mains feed is in the centre and swings to feed the Sol-Ark at the bottom and the panel at the top.
    However when it's up and connected to the mains, surely the Sol-Ark feed to the panel is live from a backfeed from the panel? Or am I missing something?

  • @jackwalsh1468
    @jackwalsh1468 ปีที่แล้ว

    Scott, another awesome job, but the esoteric crowd would like to know. Did you throw in a Solar powered "Kitchen Sink" too??? Cheers, Mate.

  • @jybuis3939
    @jybuis3939 ปีที่แล้ว

    Awesome build. What gauge did you use for the 775 ft PV run, and what were the PV specs after combiners -- OC voltage and short-circuit amps? Love to know those deets..thanks

  • @xity
    @xity 11 หลายเดือนก่อน

    Hi Engineer775, why did you choose to use a fusable disconnect over a non-fused disconnect? I'm asking because I'm planning an off-grid install and couldn't convince myself that I needed a fusable disco with with a solark 30K inverter.

  • @DrDan268
    @DrDan268 ปีที่แล้ว

    How big was the generator?

  • @EastyUK
    @EastyUK ปีที่แล้ว

    Anyone know a way to limit solar load from generator? I have an issue where if I set charge to max of the generator then any large home load will trip the generator. So I have to only charge from gen with enough buffer it doesn’t get tripped.

  • @tj11391
    @tj11391 10 หลายเดือนก่อน

    What wire is the flexible 4/0?

  • @balrog006
    @balrog006 ปีที่แล้ว

    48 panels on a single Sinclair-NICE!

  • @xzibit8614
    @xzibit8614 ปีที่แล้ว +1

    How much voltage drop on a 775ft run?

    • @Projectzeroto60
      @Projectzeroto60 ปีที่แล้ว

      There will be 4.13 percent drop, assuming those panels make 20 amps and 200 volts per string

  • @solarcharging9743
    @solarcharging9743 ปีที่แล้ว

    The Solark doesn't have a high enough surge capacity nor a long enough life expectany to meet my needs. I chose a heavier duty, longer lived, much higher surge capacity, low frequency, transformer based inverter for my off grid home's system.

    • @engineer775
      @engineer775  ปีที่แล้ว

      What is your round trip efficiency?

    • @solarcharging9743
      @solarcharging9743 ปีที่แล้ว

      I'm not concerned about my system's round trip efficiency because I have adequately sized my battery bank with more capacity than I need for my daily consumption, taking into consideration, 3 days of no solar production. If I were using my inverters for a mobile application, with limited energy storage, then maybe, maybe, I might be concerned about round trip efficiency. Besides, you're only talking about an efficiency difference of maybe 3% to 4% which is not worth considering for a shorter inverter life expectancy and a much lower surge capacity for starting and running critical loads. @@engineer775

  • @OldePhart
    @OldePhart ปีที่แล้ว

    Impressive work there. I'm using one of those SolArks instead of a generator at a telemetry site whose normal draw was far too low for a generator most of the time. I'm mostly happy how this worked out but seems that 5 SimpliFi batteries didn't give me enough runtime to account for a drunk driver taking out the poles from the grid requiring days of backup... Tell me more about these batteries you selected? Can I mix more of those into this pack or should I stick with the SimpliFi? These also have their own built in BMS but do not expose it for outside monitoring so the Solark is not doing it either. I'm a SCADA and Controls guy so I want to be able to see everything if I choose to do so and batteries rarely let me at this scale... which is odd to me as the consumer sizes often do.
    And Yea, the touchscreens on the SolArks are terrible and hard to see in sunlight... so is the wired ethernet connection if you have no DHCP available. They gotta think just a little more industrial and allow static IP settings that actually work.

    • @ewouk61
      @ewouk61 ปีที่แล้ว

      Have you tried a raspberry pi with a usb to serial converter plugged into the solark?

    • @OldePhart
      @OldePhart ปีที่แล้ว

      @@ewouk61I can and do read the solark through the modbus interface just fine, I can't read the batteries themselves because they each have their own BMS and don't expose an interface of any kind.

  • @rafaelbeltraobronzon6192
    @rafaelbeltraobronzon6192 ปีที่แล้ว

    If I may ask, why use 2x Solark 15k instead of a 30k?

    • @engineer775
      @engineer775  ปีที่แล้ว +2

      The 30k is a three phase 208 volt inverter so it is not the right inverter for this split phase job.

  • @SI-lg2vp
    @SI-lg2vp ปีที่แล้ว

    Suggestion. Cell phone video is very distracting with the split video. Most people would prefer just watching the main video without the side screen effects.

  • @guidedbygreen1480
    @guidedbygreen1480 ปีที่แล้ว

    Wow 775 feet of HVDC ... Shoulda used Enphase and could have made that long homerun cabling AC.

    • @jacobh8834
      @jacobh8834 ปีที่แล้ว +3

      Why would enphase be preferable? DC system can be higher voltage than 240v ac which means less voltage drop and smaller wire.

    • @bradspaugh9827
      @bradspaugh9827 ปีที่แล้ว

      That would be way worse!

    • @guidedbygreen1480
      @guidedbygreen1480 ปีที่แล้ว

      @@jacobh8834 same reason why the utility prefers transmitting AC over long distances over DC.

    • @isovideo7497
      @isovideo7497 ปีที่แล้ว

      @@guidedbygreen1480 DC is actually preferred over AC - capacitative and inductive losses become negligible. The utilities like AC because it can directly feed transformers.

    • @jacobh8834
      @jacobh8834 ปีที่แล้ว

      @@guidedbygreen1480 ​Yeah but utility transmission lines operate at thousands of volts while enphase only operates at 240v. Its not that AC is better over distances, its just that its easier to step up/down voltages for with transformers.

  • @mohdsharif4209
    @mohdsharif4209 ปีที่แล้ว

    @Outdoor with morgan house….

  • @chucksanders7131
    @chucksanders7131 ปีที่แล้ว +1

    If the owner runs his inverters at full bore for 2 hours, they will drain the entire battery bank in 2 hours. Then you are running off the generator.... In a situation that the owner is preparing for, it will be a matter of time before they run out of fuel. Hopefully the owner doesn't live in a place with long cold winter with dark days and or has wood fired heat. Looks like you took someones fuck you money and sold them "security" lol. A sucker is born every second. I am sure the locals know where this is, and it won't work out well for the owner long term in a SHTF situation. The best part is that the owner won't know how to do any troubleshooting if the system has any issus, because he is the type to just pay someone else to worry about it. My guess is that you charged the shlep around 150k to build that. I built a system half that size with a clear view of the south for around 35k. Also, bifacial is usually a waste.

    • @rustyshackle917
      @rustyshackle917 ปีที่แล้ว

      Clear case of more money than sense.

    • @silverbackag9790
      @silverbackag9790 ปีที่แล้ว

      Hop off your ass and start filming then and show us all how it’s done.

  • @40motomike
    @40motomike 27 วันที่ผ่านมา +1

    @engineer775 what wire is that you are ising? @13:40 the 4/0 flexible feeder wire? Is that the same as the SER or is that DC?
    Trying to find some flexible SER cable presently. Can i use MTW or is there a specific easier to work with wire to go from the meter out ...