  • Solis EPM1-5G Model has a maximum of 10 Solis GTi in parallel connection. The hardware is needed when you are doing parallel connection on your GTi when you want to limit your production.
    EPM serves as your governor to properly manage export power on each GTi connected to the system.

ความคิดเห็น • 30

  • @jovpal5685
    @jovpal5685 10 หลายเดือนก่อน

    Hi Sir can you use a standard 5-8kw CT clamp on a 60kw inverter? DI kasi nag tell si Supplier nga HINDI kasama yong CT clamp gusto kasi mag EMP yong may-ari ayaw mag net metering

    • @MarkMinoza
      @MarkMinoza  10 หลายเดือนก่อน

      hindi po puede pag EPM po gamit nyo. It should be 5a secondary coil.

    • @jovpal5685
      @jovpal5685 10 หลายเดือนก่อน

      @@MarkMinoza Sir anong alternative gawin muna namin don? mag order pa ako ng 5a coil
      at yong 60kw na pinag setup ko Sir may alarm error nga L & PE fail pero nag generate nman

    • @MarkMinoza
      @MarkMinoza  10 หลายเดือนก่อน

      @@jovpal5685 may local support si Solis, consult your seller to have you connected. pag EPM, walang ibang choices, pag mali ang CT na gamit, mali din ang reading. reduce muna the pv input as not to export power. as for your alarm, mag depende yan sa 3P grid type nyo, though you can disable it.

    • @jovpal5685
      @jovpal5685 10 หลายเดือนก่อน

      @@MarkMinoza Regarding sa alarm Sir baka ibang software na gamit kasi sinabi ng electrician namin walang daw ground wire sa AC area ng inverter
      may alam kaba sir pano mag disable ng alarm sakali?
      THANK YOU SO MUCH Sir subcribed na po

    • @MarkMinoza
      @MarkMinoza  10 หลายเดือนก่อน +1

      @@jovpal5685 consult the local support kasi po 3P po yan, hindi puedeng baliwalain. They can assess anong issue nyo pag nakita nila ang alarm.

  • @humbeym4878
    @humbeym4878 2 ปีที่แล้ว +1

    hi sir can we put WIFI dongle in COMMUNICATION port of EPM for monitoring in phone?

    • @MarkMinoza
      @MarkMinoza  2 ปีที่แล้ว +1

      You need Wifi Box for EPM. Wifi Stick is only for Inveters. Wifi Stick = 1 to 1, Wifi Box = 1 to many. Ill post how to configure and connect it on my next up coming video.

    • @humbeym4878
      @humbeym4878 2 ปีที่แล้ว

      @@MarkMinoza hi sir where to put EPM port in inverter how to connect it

    • @humbeym4878
      @humbeym4878 2 ปีที่แล้ว

      sa COM po ba ng inverter at COM INV ng EPM ikakabit ung cable? para magkonek sila

    • @humbeym4878
      @humbeym4878 2 ปีที่แล้ว

      kaya di na po mailagay ung WIFI dongle sa inverter kase dun nakakabit sa COM ng inverter ung EPM

    • @MarkMinoza
      @MarkMinoza  2 ปีที่แล้ว

      @@humbeym4878 that will be my next video, hopefully next week I'll post it.

  • @wirebrigade4306
    @wirebrigade4306 2 ปีที่แล้ว

    Can you fit 2 hybrid inverters on 1 phase with EPM1 unit?

    • @MarkMinoza
      @MarkMinoza  2 ปีที่แล้ว

      Hybrid is not yet compatible to use on EPM.

    • @wirebrigade4306
      @wirebrigade4306 2 ปีที่แล้ว

      On solis webinar it says to use one with 2 hybrids that’s why I bought it.

    • @MarkMinoza
      @MarkMinoza  2 ปีที่แล้ว

      @@wirebrigade4306 I have a hybrid and a GTi, I cant wire my Hybrid to EPM as per support. Its not compatible yet.

  • @jonathanvidal-n5p
    @jonathanvidal-n5p ปีที่แล้ว

    Sir how much the epm?

    • @MarkMinoza
      @MarkMinoza  ปีที่แล้ว

      25k when i bought it. Excluding the CT.

  • @amazingadrijana5636
    @amazingadrijana5636 3 หลายเดือนก่อน

    Comm-INV doesn’t fit please. It is different one

    • @MarkMinoza
      @MarkMinoza  3 หลายเดือนก่อน

      You might have a different model. But the connectivity should be the same.

  • @jfncmn8036
    @jfncmn8036 2 ปีที่แล้ว

    pwede maka pa online tutor sir. meron ako 30kw 3p solis i install

    • @MarkMinoza
      @MarkMinoza  2 ปีที่แล้ว

      You may join the Local Support sa FB. facebook.com/groups/413473389645478