    @HVACKnowItAll  5 หลายเดือนก่อน +2

    Nitrogen brazing is a thing

  • @dpayne3195
    @dpayne3195 3 หลายเดือนก่อน +1

    Fan of the podcast from out of North Carolina

    • @HVACKnowItAll
      @HVACKnowItAll  3 หลายเดือนก่อน

      Thank you, I appreciate that!

  • @l.crossjr
    @l.crossjr 4 หลายเดือนก่อน +1

    Geat video. I know you did not flow nitro for demonstration purposes, what is the best way to remove those flakes from that txv afterwards?

    • @HVACKnowItAll
      @HVACKnowItAll  4 หลายเดือนก่อน

      Using a flush system like RX11 flush but nitrogen will avoid all that. In reality RX11 is only for linsets

  • @USA-GreedyMenOfNoIntegrity
    @USA-GreedyMenOfNoIntegrity 5 หลายเดือนก่อน

    Heat the joint first. If your gap is snug, heat will transfer quickly to pipe. If not snug, use a lever type swaging tool.

  • @hliz8818
    @hliz8818 5 หลายเดือนก่อน +1

    Cool Video. Brazing with Nitrogen is cool.. i put regulator on 3.. at 6 I notice nitrogen pushing out filler... had that ever happened to you

    • @HVACKnowItAll
      @HVACKnowItAll  5 หลายเดือนก่อน

      If the flow is too high yes, that can happen

  • @Dicofol1
    @Dicofol1 5 หลายเดือนก่อน +1

    Can you make a video about Stay Brite 8 as an alternative to high temp brazing?

    • @HVACKnowItAll
      @HVACKnowItAll  5 หลายเดือนก่อน +1

      I'm working on it

  • @chrissipple1018
    @chrissipple1018 5 หลายเดือนก่อน +1

    Always ask if the nitrogen cylinder has been used for clean nitrogen only. Sometimes the cylinder was used for some other gas and it just gets repainted. If it has had some other gas in it you now have dirty nitrogen and you can get high levels of copper oxide inside even though it's clean gas. If possible get only medical grade nitrogen, the sales person will probably give you a strange look but tell them that is what you want. And even with clean and pure nitrogen you will get some copper oxide build up.

    • @HVACKnowItAll
      @HVACKnowItAll  4 หลายเดือนก่อน

      Counter guy will zero idea about this

  • @NestorDelgado-fr6pu
    @NestorDelgado-fr6pu 5 หลายเดือนก่อน

    Do you recommend always change your txv when changing a compresor.?

  • @thecurious6721
    @thecurious6721 หลายเดือนก่อน

    The reason people make negative comments about your brazing because every "expert" teaches brazing differently. Some say start at the pipe than move to the fitting, this one said to start at the fitting then move heat to the pipe 😂 Even harris and lucas-milhaupt "experts" cant agree on the type of flame if it must be neutral or reducing 😂

  • @rollaae82
    @rollaae82 5 หลายเดือนก่อน

    What is the main reason for the acces port?

  • @ayoutubewatcher7009
    @ayoutubewatcher7009 5 หลายเดือนก่อน +2

    Heat the pipe then the joint

    • @HVACKnowItAll
      @HVACKnowItAll  5 หลายเดือนก่อน

      Heat the joint them move the heat away not bring it towards

    • @eastcoast186
      @eastcoast186 5 หลายเดือนก่อน +1

      Fantastic video and info thanks

    • @HVACKnowItAll
      @HVACKnowItAll  5 หลายเดือนก่อน

      My pleasure thank you! ​@@eastcoast186

  • @thecurious6721
    @thecurious6721 หลายเดือนก่อน

    Funny thing. In real life I've never seen anyone using nitrogen (except myself when I was green).