Hola, Primero de todo, muchas gracias por contactarnos. Por favor, ¿nos puede decir desde dónde nos escribe y si nos escribe como particular o empresa? Muchas gracias. Un saludo. El equipo de Fronius
Hi, I am writing as a consumer. My setup is a gen 24 plus 6.0, 5.4kWp, HVS 5.12kWh and a smart meter. I live in Greece where I am being charged for per phase energy consumption. So the new asymmetric power distribution is a huge advantage with the new firmware (thank you!). A few problems to note: 1) Solarweb doesn't take account per phase energy transfer but takes the sum of the phases. From the web interface of the inverter I can see from the smartmeter the energy transfer correctly and in HomeAssistant I can track my correct feed in/out energy. Please add an option in solarweb for countries that charge per phase energy transfer and not altogether. 2) Wattpilot does not take into account the above problem so when I have surplus 3.000w it tries to charge with the same amount using 1 phase which exceeds my inverters capability of asymmetric distribution (max 2.000w). So instead of charging only with energy surplus I end up feeding-in 1000w and feeding-out 1000w! If there is a better place to communicate/chat please let me know. Thank you, Theodoros
Hi @Theodoros-um8ls Thank you for your question. Please get in contact with our support team: shorturl.at/h6Grx They will assist you quickly. Best regards, Daniela from Fronius
Hola, Primero de todo, muchas gracias por contactarnos. Por favor, ¿nos puede decir desde dónde nos escribe y si nos escribe como particular o empresa? Muchas gracias. Un saludo. El equipo de Fronius
01:06 missed serving the users wishlist 🤷🏻♂️
Hola,
Primero de todo, muchas gracias por contactarnos.
Por favor, ¿nos puede decir desde dónde nos escribe y si nos escribe como particular o empresa?
Muchas gracias. Un saludo. El equipo de Fronius
Hi,
I am writing as a consumer. My setup is a gen 24 plus 6.0, 5.4kWp, HVS 5.12kWh and a smart meter. I live in Greece where I am being charged for per phase energy consumption. So the new asymmetric power distribution is a huge advantage with the new firmware (thank you!).
A few problems to note:
1) Solarweb doesn't take account per phase energy transfer but takes the sum of the phases. From the web interface of the inverter I can see from the smartmeter the energy transfer correctly and in HomeAssistant I can track my correct feed in/out energy. Please add an option in solarweb for countries that charge per phase energy transfer and not altogether.
2) Wattpilot does not take into account the above problem so when I have surplus 3.000w it tries to charge with the same amount using 1 phase which exceeds my inverters capability of asymmetric distribution (max 2.000w). So instead of charging only with energy surplus I end up feeding-in 1000w and feeding-out 1000w!
If there is a better place to communicate/chat please let me know.
Thank you,
Theodoros
Hi @Theodoros-um8ls
Thank you for your question. Please get in contact with our support team: shorturl.at/h6Grx They will assist you quickly.
Best regards,
Daniela from Fronius
Hola tengo una configuración aislada de victron con fronius en ac coupling en este caso integrar un cargador de fronius es la mejor opción???
Hola,
Primero de todo, muchas gracias por contactarnos.
Por favor, ¿nos puede decir desde dónde nos escribe y si nos escribe como particular o empresa?
Muchas gracias. Un saludo. El equipo de Fronius