Leaking lead pipe repair | Lead-Loc

แชร์
ฝัง
  • เผยแพร่เมื่อ 31 ธ.ค. 2024

ความคิดเห็น • 172

  • @loafersheffield
    @loafersheffield 5 ปีที่แล้ว +12

    Note of caution folks! If you have to turn off the mains water authority stop tap in the street, particularly when working in terraced properties in UK, ensure that it does not serve more than the property you are working at. Quite often, it may serve 2 or more properties.
    It is essential that you seek the permission of the neighbours first and usually verbal approval is enough. Diplomatically explain that they extend this courtesy as in turn, they may want this extended to themselves in future.
    I had this job around 3-4 years ago. The mains stop in the street served 3 houses. I sought permission from one property but could not get the other householders to answer the door. I presumed that there was no-one in residence. I posted a note just in case they returned whilst I was working.
    Within an hour, I had both Yorkshire Water and South Yorkshire Police attend and threaten to serve me with a section 42 notice, for turning off the water in the street. Thankfully, I had a 7lb lead-loc with me (the most common size required for this job) I did not have to take a cut out section to the plumbers merchants to get a correct size. I reinstated the water within an hour of turning it off in the street. The job was in Rotherham. One would have presumed that the police in particular, would have had better things to occupy their time

    • @ultimatehandyman
      @ultimatehandyman  5 ปีที่แล้ว +1

      Blimey, what a waste of police time!
      At my old house the stop tap was at the end of the row of terraced houses and if you turned it off, it turned off the whole row, unless they had had their lead pipe replaced with MDPE.
      Thanks for the info ;-)

    • @loafersheffield
      @loafersheffield 5 ปีที่แล้ว

      You're welcome.

    • @mladenenglang
      @mladenenglang 9 หลายเดือนก่อน

      What's wrong with these people? Who is calling a police for this? We have One Stop shop next to our house. They have got same shoplifters every day, that steal things without any shy by big bags! No one does anything about it.

  • @slaterryan123
    @slaterryan123 3 ปีที่แล้ว +1

    Great video. Just fixed a leak in my bathroom thanks to your guide here.

    • @ultimatehandyman
      @ultimatehandyman  3 ปีที่แล้ว

      I'm glad the video helped
      Thanks for the comment 👍

  • @DavidBrown-pr6kj
    @DavidBrown-pr6kj 7 หลายเดือนก่อน

    Brilliant and so informative, thank you as that clear and concise guide is gonna get me out a hole!

  • @keepitmoving5440
    @keepitmoving5440 5 ปีที่แล้ว

    Glad i watch this, it has put my mind at ease with lead pipes. I do alot of copper but my first time with lead. Thanks mosh

  • @WayneBurgess1
    @WayneBurgess1 12 ปีที่แล้ว +1

    A hooked lead knife is good to have in your box too for things like this and also for flashings.No problem doing it the way you have just harder to control a stanley knife and easy to snap the blade. :)

  • @Gez734
    @Gez734 3 ปีที่แล้ว

    excellent video. Really clear and concise. Thank you. Wish i watched this 2 weeks ago, but done job for me here.

  • @ateleskier7066
    @ateleskier7066 6 ปีที่แล้ว

    Excellent video as ever; clear and concise with all key points covered - very useful. Thanks for sharing.

  • @nsoo85
    @nsoo85 ปีที่แล้ว

    Mi brother thanks you so much master of masters 🙏 thanks you ... I am from maryland just another plumber nice vidoe ❤

    • @ultimatehandyman
      @ultimatehandyman  ปีที่แล้ว

      You are welcome
      Thanks for the comment 👍

  • @ningis21
    @ningis21 12 ปีที่แล้ว

    Kevan, Thank you for pointing out that you need to be Gas Safe Registered, This I was aware of, but, noticed that in several you tube videos from several sources, on this topic, that the use of this type of joint on lead pipe was unacceptable and I thought that I would bring this issue up for the benefit of everyone watching. You seem to be the only one to mention being G.S.R. to work on Gas, however, the video producers in all cases stated that the Leadloc joint was unsuitable for Gas. TNX

  • @WayneBurgess1
    @WayneBurgess1 12 ปีที่แล้ว +8

    Do't forget to cut in a drain off, directly above the stop tap :)

  • @loisgriffiths8562
    @loisgriffiths8562 8 ปีที่แล้ว +4

    Great video - and quite possibly the worlds finestLlancashire accent...

  • @KevRCDrift
    @KevRCDrift 11 ปีที่แล้ว +1

    Lead isn't used in pipes in the UK and hasn't been for donkeys years but there's still miles of the stuff in use in old houses

  • @ernestchadwell9069
    @ernestchadwell9069 ปีที่แล้ว +1

    Lead swarf has already gone down the pipe when you cut it with the hacksaw.

    • @ultimatehandyman
      @ultimatehandyman  ปีที่แล้ว +1

      It will soon flush out, when you open the tap 👍

  • @jamieanderson8875
    @jamieanderson8875 2 ปีที่แล้ว

    Hi I have an old lead main beaten flat under a first floor tiled toilet room. It seems there was no stop cock so the builders hammered it flat. It’s now weeping and I’ve cut a hole in the kitchen ceiling below to expose it. What is the best was to fit a lead lock if I can’t isolate the water supply? Thanks 😊

    • @ultimatehandyman
      @ultimatehandyman  2 ปีที่แล้ว

      Really, that pipe needs disconnecting at its source. A pipe should never be capped like that, as the water can go stagnant and can contaminate the whole water main (or so I have been led to believe).

  • @Injusticestinks
    @Injusticestinks 9 ปีที่แล้ว

    Not a bad video, - what to do if you're on a common supply? The old communal stop taps rarely shut off completely so it prudent to have the neighbours on side before attempting this job.

    • @ultimatehandyman
      @ultimatehandyman  9 ปีที่แล้ว

      Graham Oliver
      We used to be on a communal supply, which was lead but luckily most of the other neighbours had had their own MDPE supply installed so only a few people on the street were affected. I normally tried to do any work requiring the stop tap to be shut off when everyone was out or at work.
      If the stop tap is not shutting off properly, can you not get the utility company to fix it as it's normally their responsibility?

    • @malachy1847
      @malachy1847 7 ปีที่แล้ว +1

      ...Indeed correct it's the Utility providers problem......Great Upload......[couldn't even find my old Boundary Stopcock got onto the Local Authority here in Rural Ireland they came out used an Ultrasonic Sounder to locate mine simply when running a tap on our property they could then hear the hiss of the pressure drop and cavitation across the stopcock and exposed same.... all was good until i tried isolating same but stopcock was passing lol... they came back and fitted a proper Boundary Box...No domestic water utility bills here in Ireland as yet the folks took to the streets and protested regarding same.... ]

  • @mladenenglang
    @mladenenglang 9 หลายเดือนก่อน

    Yesterday I was using 22mm to 15mm reducer to make this job. It's very insecure and leaking. I used all the white tape, then I used black PVC tape, but it's still leaking. I'll try this one today.

    • @ultimatehandyman
      @ultimatehandyman  9 หลายเดือนก่อน

      These are great on lead, or you can also use a Philmac UTC-
      th-cam.com/video/_k5NS5Y-KHg/w-d-xo.html

  • @JohnSmith-vz8pc
    @JohnSmith-vz8pc 6 ปีที่แล้ว +2

    Sorry, I could hear you for the first part of the video, as you were in an echoing brick shell, and not wearing a microphone. I think you should have made the second cut first, and it would have taken the weight off where you were cutting the lead pipe. 4.30 Don't you have plumbing spanners in your toolbox?

    • @ultimatehandyman
      @ultimatehandyman  6 ปีที่แล้ว

      No, I don't use plumbing spanners. Most of the plumbers I know use either an adjustable or water pump pliers.
      I did but a specific spanner once for compression fittings- but it was a pile of junk (stamped steel)
      Thanks for the comment

    • @gasgiant7122
      @gasgiant7122 4 ปีที่แล้ว

      Armchair tradesman!

  • @trench01
    @trench01 2 ปีที่แล้ว

    can i used "SELF FUSING PIPE REPAIR TAPE" if their is a hole as shown on youtube on a lead pipe?
    Also how much would what you did cost? if it it on an elbow entering the home?

    • @ultimatehandyman
      @ultimatehandyman  2 ปีที่แล้ว

      You could do, but I do not know how long the tape will last.
      I think it's about £15 for a lead loc, but it depends on the size.
      I don't think they make lead lock elbows- you would have to alter the pipework.

  • @JJ-jc8yv
    @JJ-jc8yv หลายเดือนก่อน

    Would you only recommend to use lead loc by melimatic or any other as good as?

    • @ultimatehandyman
      @ultimatehandyman  หลายเดือนก่อน

      I have only used the lead Loc fittings on lead pipes and they have always been good, but I’m sure you can also use Philmac universal transitional couplings too (both of these manufacturers are trusted) th-cam.com/video/_k5NS5Y-KHg/w-d-xo.html
      👍

  • @MrMagsimus
    @MrMagsimus 3 ปีที่แล้ว

    Top video mate , loved it very simple and great information thanks pal 👌✊

    • @ultimatehandyman
      @ultimatehandyman  3 ปีที่แล้ว

      I'll try to do that in future
      Thanks for the comment 👍

  • @westonsunset
    @westonsunset ปีที่แล้ว

    Hi Ultimate H, I very much enjoy your videos and have learnt a lot from you over the last couple of years, I wondered what is the brand of the pump grips you use please? Best wishes, Mark.

    • @ultimatehandyman
      @ultimatehandyman  ปีที่แล้ว +1

      Hi Mark, that’s great to hear 😉
      I have about 4 different pairs of water pump pliers.
      I think the ones in the video were both made by C.K tools, although I do also have Knipex 👍

  • @andrewhaines8603
    @andrewhaines8603 5 ปีที่แล้ว

    Just seen this today after puncturing the lead main pipe in the kitchen of a house we are doing up. Don't ask, but I was actually carefully chasing out some ring main cable and the water pipe was immediately below it! Yes thankfully I had the sense to turn off the electricity otherwise I'd not be here now! (If it had been copper I'd have just bounced off it.) The pipe will need to be moved anyway as the wall is coming out, but it is too misshaped to fit a lead lock. Can it be temporarily repaired with plumbers mait or similar?

    • @ultimatehandyman
      @ultimatehandyman  5 ปีที่แล้ว

      You could perhaps wrap the pipe with a repair bandage, or even some of that special tape designed for leaking pipes- as a temporary measure?

    • @andrewhaines8603
      @andrewhaines8603 5 ปีที่แล้ว

      @@ultimatehandyman cheers. The pipe is still quite buried in the wall so I'm very wary of chopping out around the pipe. Just need it back on to put the heating on. Wet electrics are something else! Any products to recommend?

    • @ultimatehandyman
      @ultimatehandyman  5 ปีที่แล้ว

      You might be as well using something like this- fave.co/37g7pTx
      I've never tried it myself, but obviously you do not want to disturb the pipe!

  • @cvarsani2190
    @cvarsani2190 5 ปีที่แล้ว

    Is there any harm in shaving off too much lead, will the lead loc be loose and issue with grab repair ngs or washers not tighning properly

    • @ultimatehandyman
      @ultimatehandyman  5 ปีที่แล้ว

      Yes, you do not want to shave too much off!
      Thanks for the comment 👍

  • @thisandthat797
    @thisandthat797 4 ปีที่แล้ว

    My lead pipe was leaking and the pipe was too small for the lead lock..iv gt a temporary compression fitting on..any advice on more permanent solution (apart from the mde pipe) thanks

    • @ultimatehandyman
      @ultimatehandyman  4 ปีที่แล้ว

      Philmac make a fitting that will work on lead pipe, or any pipe, you can also get them to reduce at the other end.
      th-cam.com/video/_k5NS5Y-KHg/w-d-xo.html
      I hope this helps ;-)

  • @kevanrimmer3583
    @kevanrimmer3583 12 ปีที่แล้ว

    There are some fantastic videos here

  • @123a-o5d
    @123a-o5d 10 ปีที่แล้ว

    Can I join lead to plastic to copper (my hot water lead pipe leaks)? Are these fittings suitable for blue MDPE only or can they be used with standard grey barrier? I have 1 5/16" diameter lead pipe (it's big), to be joined to 22mm copper...

    • @ultimatehandyman
      @ultimatehandyman  10 ปีที่แล้ว

      Take a look at the universal transitional coupling ;-)
      Universal Transitional Coupling | Philmac UTC

    • @123a-o5d
      @123a-o5d 10 ปีที่แล้ว

      ***** thanks, UTCs are for cold only though. I have however found a lead-loc big enough for this pipe, I'll have to shave it a bit though...so I'll have a go with that. BTW Lead-loc's advice is it should be ok with barrier instead of copper but they haven't yet tested this (they've tested only with mdpe and copper).

    • @ultimatehandyman
      @ultimatehandyman  10 ปีที่แล้ว

      123a
      I forgot the utc's were only for cold water- sorry!
      Glad you have found a solution ;-)
      Thanks for the comments

    • @kimboly4213
      @kimboly4213 8 ปีที่แล้ว

      123a

  • @jmr54
    @jmr54 ปีที่แล้ว

    Why must the lead be shaved off is it just to fit or give an edge

  • @michealjordan6754
    @michealjordan6754 3 ปีที่แล้ว

    Where can I purchase one of theese from? do they sell in store anywhere

    • @ultimatehandyman
      @ultimatehandyman  3 ปีที่แล้ว

      This is their website, which has a list of distributors, but most plumbers merchants stock them-
      www.melimatic.com/

  • @karlos2040
    @karlos2040 11 ปีที่แล้ว

    hi thanks for the video, you mention a united utilities scheme to replace the led? can you tell me more about it, i have the same set up in my house as this video

    • @ultimatehandyman
      @ultimatehandyman  11 ปีที่แล้ว

      Yes, they have a scheme where if you replace the lead pipe going from your boundary to your property (as in this video Lead pipe replacement ), they will come and disconnect the old lead pipe and connect the new pipe up. You have to ring them first and be accepted onto the scheme before starting, they also send out an inspector to check the work before sending out the guys to dig up and do the connections.

    • @karlos2040
      @karlos2040 11 ปีที่แล้ว

      great ill get on to them, thanks again for the video and getting back to me

    • @ultimatehandyman
      @ultimatehandyman  11 ปีที่แล้ว

      Ka Chri
      You are welcome

  • @finallymadeusername
    @finallymadeusername 11 ปีที่แล้ว

    Going to try this on our leak until landlord decides to fix it. Should I be worried worried about breaking the lead pipe when I tighten the connector around it? Couple of plumbers told me they wouldn't do this kind of fix because lead is so soft.

  • @ningis21
    @ningis21 12 ปีที่แล้ว

    Just a couple of points Kevan, You have presumed that I am not GSR.. and suggested that I would put other peoples lives at risk doing such a stupid thing as using a Leadloc on lead Gas pipe. You have made a mistake.
    I asked the question ...for everyone elses benefit, but I would like to thank you for pointing out that you need to be Gas Safe Registered to work on Gas. Thanks again Kevan, and to the video producers for stating that Leadlocs are NOT suitable for GAS.

  • @ericthekingthekingtheking4842
    @ericthekingthekingtheking4842 9 ปีที่แล้ว

    hi handyman on a slightly different agenda how can i move my stop tap its in a really inacessable place how do you go about turning the water off thats coming into the property so i can extend / move the tap .any advice be appreciated cheers

    • @ultimatehandyman
      @ultimatehandyman  9 ปีที่แล้ว +1

      +Roy Kirkham
      There should be a stopcock at the boundary of the property, which you should be able to isolate. But moving it will be a pain!
      Some people leave the existing on where it is and then install another one in a more convenient location, you can then use either of them to isolate the water ;-)

    • @ericthekingthekingtheking4842
      @ericthekingthekingtheking4842 9 ปีที่แล้ว

      +Ultimate Handyman
      so do you mean extend from existing stop tap to a new tap .say under the sink an obviously the old stop tap will need to be left turned on.
      also whats the process for turning it off at the boundary do you need special tools / spanners or out .sorry for my naivity

    • @ultimatehandyman
      @ultimatehandyman  9 ปีที่แล้ว

      +Roy Kirkham
      Yes, you should be able to isolate the existing stop tap in the property, then cut the pipe at a convenient location after it (under the sink if that's convenient), then install a second stop tap. Then you leave the original stop tap open and use the new one to do the isolation in future.
      How to isolate the water is here- www.ultimatehandyman.co.uk/how-to/plumbing/isolate-the-water-supply
      If you don't have a stopcock key you can make one from some scraps of timber- www.ultimatehandyman.co.uk/how-to/woodworking/stop-cock-key
      Sometimes you find that the outside tap has seized, I'm pretty certain that it is the water companies responsibility to ensure it can be isolated.
      Thanks for the comments ;-)

    • @ericthekingthekingtheking4842
      @ericthekingthekingtheking4842 9 ปีที่แล้ว

      +Ultimate Handyman
      cheers pal my tap is right in a corner of a deep cupboard .think il put a second tap in as suggested.thanks for the info your a wealth of knowledge 👍

    • @ultimatehandyman
      @ultimatehandyman  9 ปีที่แล้ว +1

      +Roy Kirkham
      You are welcome ;-)

  • @ArksE8
    @ArksE8 9 ปีที่แล้ว

    The stopcock in my house is on lead pipe. If i use 2 lead locks to join to copper, once i remove the stopcock. and put a new stopcock on the copper will this work??

    • @ultimatehandyman
      @ultimatehandyman  9 ปีที่แล้ว

      +Arks Shackerwell (ArksE8)
      You only need the one lead loc fitting as you can get one that is for lead on one side of the fitting and copper on the other side.

    • @ArksE8
      @ArksE8 9 ปีที่แล้ว

      ***** Thanks for the quick response. the whole pipe is lead so what do you think?? Just watched one of your vids about utc fittings. 👍👍👍 love your channel

    • @ultimatehandyman
      @ultimatehandyman  9 ปีที่แล้ว

      +Arks Shackerwell (ArksE8)
      It depends how high up the pipe the stopcock is. As long as there is plenty of room you should be able to switch off the water in the street, then cut the lead and use either a lead loc or a UTC to connect to copper and put a new stopcock in the copper. I know it's a big job but have you considered replacing the lead pipe?
      th-cam.com/video/6MWSWz3YVPo/w-d-xo.html

    • @ArksE8
      @ArksE8 9 ปีที่แล้ว

      yes I have given it a thought I just need to find the time. When are you going to employ from youtube?? lol

    • @ultimatehandyman
      @ultimatehandyman  9 ปีที่แล้ว

      +Arks Shackerwell (ArksE8)
      LOL

  • @romandarko2415
    @romandarko2415 5 ปีที่แล้ว

    excellent demo !

  • @neiluk4983
    @neiluk4983 4 ปีที่แล้ว

    I need to cap mine off altogether and bury it what do I need thanks.

    • @ultimatehandyman
      @ultimatehandyman  4 ปีที่แล้ว +1

      You have to ensure that you do not create a dead leg, where water can collect and go stagnant. So you have to cap it off at the feed end of the pipe. This might be useful-
      www.melimatic.com/7.html

  • @kulespi
    @kulespi 11 ปีที่แล้ว

    I need an advice from an expert. Lets say you have a lead pipe drain in the bathroom, going from the bathtub across bathroom. So about 2 meters of horizontal drain. Pipes are 30 years old. So if you exclude faulty joints (where the leak will obviously appear), is it possible for those lead pipes to corrode and leak because of corrosion somewhere in the middle of the pipe? If there is a joint of lead pipe with cast iron bathtub, cast iron will corrode much faster or?

    • @arcfired3615
      @arcfired3615 11 หลายเดือนก่อน

      nots sure

  • @cassalisepropertyworks7324
    @cassalisepropertyworks7324 11 ปีที่แล้ว

    where do you get the lead loc fittings?

  • @Craneformers
    @Craneformers 5 ปีที่แล้ว

    How best to connect lead mains pipe to MDPE?

    • @ultimatehandyman
      @ultimatehandyman  5 ปีที่แล้ว

      You can use a lead loc connector, or a Universal transitional coupling- th-cam.com/video/_k5NS5Y-KHg/w-d-xo.html
      Thanks for the comment ;-)

  • @ningis21
    @ningis21 12 ปีที่แล้ว

    Hi ... Good Video... Just wanted to check something with you.....These Leadloc's.. Are they safe on Gas pipes (lead to copper) ?? All the videos show them being used soley on lead water pipe.

  • @METHVS02
    @METHVS02 5 ปีที่แล้ว

    How do you work out what lb rated fitting you need?

    • @ultimatehandyman
      @ultimatehandyman  5 ปีที่แล้ว

      It tells you on this page, starting at number 8 - www.melimatic.com/7.html

  • @dom85ross
    @dom85ross 4 ปีที่แล้ว

    Are lead water mains usually 1inch?

    • @ultimatehandyman
      @ultimatehandyman  4 ปีที่แล้ว

      I've only ever seen about three lead pipes in my life, they vary depending on where you live (according to a guy in my local plumbers).
      TechTip: To determine the outside diameter of the pipe, wind a length of cotton twice around the pipe without stretching it and then measure its length.
      Divide this result by 44 and multiply this answer by 7.
      This is then the diameter of the pipe.
      Taken from here- www.melimatic.com/7.html

    • @rhys406
      @rhys406 2 ปีที่แล้ว

      The ones ive worked on are 1/2 inch 7lb or 9lb, using calipers is more convenient.

  • @TheTomplum
    @TheTomplum 12 ปีที่แล้ว +5

    you can be sure with a leadloc, I;ve never known one to fail, and lead itself is really good material, as you know it lasts for years and years, pity its poisonous ( so they say), all the old people I've ever known, drank water from lead pipes, don't think I know any long timers who drank from plastic pipes, but we'll see,
    all the best Chez, happy Easter

    • @commodoresixfour7478
      @commodoresixfour7478 2 ปีที่แล้ว +1

      Well it doesn't matter if the water comes from a treatment plant because the water is treated to not allow lead to leach into the supply.

    • @mladenenglang
      @mladenenglang 9 หลายเดือนก่อน

      My led pipe got a lever of scale inside. So I don't think it poisonous water anymore

  • @gurdipvirk9925
    @gurdipvirk9925 3 ปีที่แล้ว

    Anything wrong using Plastic?

    • @ultimatehandyman
      @ultimatehandyman  3 ปีที่แล้ว

      Plastic fittings are fine, Philmac make one- th-cam.com/video/_k5NS5Y-KHg/w-d-xo.html

  • @bad_luna5222
    @bad_luna5222 5 ปีที่แล้ว

    How does this compare to a Ford fitting?

    • @ultimatehandyman
      @ultimatehandyman  5 ปีที่แล้ว

      After a quick Google search- they seem pretty similar. I've not heard of Ford fittings before, perhaps they are not widely available in the UK.
      Thanks for the comment 👍

  • @toni160970
    @toni160970 5 ปีที่แล้ว

    very good job

  • @WayneBurgess1
    @WayneBurgess1 12 ปีที่แล้ว +1

    Ironic but for old plumbers like me who miss lead work our job is named after the stuff Plumbo the roman word for lead.
    And now theres hardly any lead in our job at all

    • @spendtimesavemoneydiy
      @spendtimesavemoneydiy 6 ปีที่แล้ว

      Wayne Burgess I hear lead work plumbing was highly skilled work! Not like today's push fit and flexi hose!

  • @TheTomplum
    @TheTomplum 12 ปีที่แล้ว

    where's that knaccky little battery junior saw you have ?, It would have pissed through the lead in seconds,
    good video thou' Chez, :-)

  • @mladenenglang
    @mladenenglang 9 หลายเดือนก่อน

    That's what I need to buy!

  • @chuck07660
    @chuck07660 8 ปีที่แล้ว

    Is this available in the US?

    • @ultimatehandyman
      @ultimatehandyman  8 ปีที่แล้ว +2

      I'm not sure, but you could ask the company that makes them- www.melimatic.com/3.html
      Or Philmac make a coupling that can be used to join virtually any type of pipe- th-cam.com/video/_k5NS5Y-KHg/w-d-xo.html

    • @njstalker8
      @njstalker8 6 ปีที่แล้ว

      Legend and Ford both sell in the US. I just bought a Legend fitting on Ebay which shipped out of New York to accomplish what's shown in the video.

  • @Vidata
    @Vidata 3 ปีที่แล้ว

    In the us we would be required by law to rip all of the lead out to wherever it ends to copper or brass or a more modern plastic pipe.

  • @11982463
    @11982463 4 ปีที่แล้ว

    Two pairs grips to tighten? No. A pair of grips and an adjustable spanner. However,great video

    • @daraghevans7637
      @daraghevans7637 4 ปีที่แล้ว

      No harm using a grips if you know what you are doing,

  • @MrBestEditing
    @MrBestEditing 9 ปีที่แล้ว

    Hi Pal,
    I recently used this fitting but very small
    Dripping
    any advise please ?
    Regards

    • @ultimatehandyman
      @ultimatehandyman  9 ปีที่แล้ว

      +MrBestEditing
      Have you tried tightening the compression nuts?
      Which side of the joint is it leaking from the lead side or the other side?

    • @MrBestEditing
      @MrBestEditing 9 ปีที่แล้ว +1

      Hi,
      Yeah After Watching Your Video, bit tighten more and it worked..Pal
      Thanks for your response buddy.

    • @ultimatehandyman
      @ultimatehandyman  9 ปีที่แล้ว +1

      +MrBestEditing
      I'm glad you fixed it ;-)
      Thanks for the update!

    • @MrBestEditing
      @MrBestEditing 9 ปีที่แล้ว

      cheers

  • @WayneBurgess1
    @WayneBurgess1 12 ปีที่แล้ว

    Not too sure a hacksall would have been much quicker than the big hacksaw but it would probably have vibrated the crap out of it LOL :)

  • @blueslsd
    @blueslsd 11 หลายเดือนก่อน

    Thank you I got one under the stairs so will be swearing a lot. Cheers .😅😅

    • @ultimatehandyman
      @ultimatehandyman  11 หลายเดือนก่อน

      I swear a lot too- I just edit it out of the video 😂
      Best of luck with it 👍

  • @johnhamill5822
    @johnhamill5822 2 ปีที่แล้ว

    Cool

  • @MrMedicalUK
    @MrMedicalUK 10 หลายเดือนก่อน

    You know ratchet pipe cutters go through lead pipe right?

  • @briancrews3218
    @briancrews3218 3 ปีที่แล้ว +1

    Haven't you people heard of lead poisoning

    • @ultimatehandyman
      @ultimatehandyman  3 ปีที่แล้ว

      Of course 😉
      They actually put a chemical in the water to prevent the lead from leaching, now they are also adding fluoride.
      Drink tap water at your own risk 😉

  • @kierangoddard2198
    @kierangoddard2198 4 ปีที่แล้ว

    I used to wipe lead joints 50 years ago but now I would always rip out all the old lead pipes and replace them with copper.

    • @ultimatehandyman
      @ultimatehandyman  4 ปีที่แล้ว

      It's always best to replace them if you can. I think it's illegal to wipe lead joints in the UK now (or so I was told)
      Thanks for the comment 👍

  • @Plumbermark
    @Plumbermark 2 หลายเดือนก่อน

    Yes thats all fine.......When the street stop works !

    • @ultimatehandyman
      @ultimatehandyman  2 หลายเดือนก่อน

      Nightmare job now, but I believe that the water supplier has to provide a way of isolating the water (I could be wrong).

  • @garyuk761
    @garyuk761 3 ปีที่แล้ว

    5 hours later we have a temp water feed... around the houses

  • @kamlesh7562
    @kamlesh7562 3 ปีที่แล้ว

    You did not replace from outside shut off valve to meter.

    • @ultimatehandyman
      @ultimatehandyman  3 ปีที่แล้ว

      That is correct, I repaired a lead pipe.
      To replace the incoming lead pipe, you need to speak to your utility company first, then do this- th-cam.com/video/6MWSWz3YVPo/w-d-xo.html&t

  • @WayneBurgess1
    @WayneBurgess1 12 ปีที่แล้ว

    And you are ducting the pipe through the wall and up to finished floor level inside :)

  • @Mrcatcherye
    @Mrcatcherye 6 ปีที่แล้ว

    tightening up with grips tut tut..wheres yr adjustables!!

    • @ultimatehandyman
      @ultimatehandyman  6 ปีที่แล้ว +1

      Water pump pliers are great on hexagonal fittings ;-)

  • @josephwright6154
    @josephwright6154 ปีที่แล้ว

    Better using a rasp to shave the lead pipe

  • @jimmywalker1568
    @jimmywalker1568 8 ปีที่แล้ว

    No shave hook

    • @ultimatehandyman
      @ultimatehandyman  8 ปีที่แล้ว +1

      +Jimmy Walker I have one somewhere, but not sure where it is exactly.

    • @jimmywalker1568
      @jimmywalker1568 8 ปีที่แล้ว +2

      Not that much lead pipe around to keep a Shave hook in tool bag even a flat dresser for the roof

  • @joeelwell162
    @joeelwell162 4 ปีที่แล้ว

    where in the world are you that plumbing codes would allow you to keep using that lead water service to the house .need to replace with a new service fronm the street,you know lead is dangerous

    • @ultimatehandyman
      @ultimatehandyman  4 ปีที่แล้ว +1

      Yes, I know lead is dangerous! There are lots of lead pipes still in the UK, this shows how to repair a lead pipe.
      Not everybody can afford to spend a few hundred pounds replacing the main supply pipe to their property, although I did with this one-
      th-cam.com/video/6MWSWz3YVPo/w-d-xo.html
      Thanks for the comment 👍

    • @rhys406
      @rhys406 2 ปีที่แล้ว

      Lead is still pretty common in the UK unfortunately.

  • @andysergeant538
    @andysergeant538 4 ปีที่แล้ว +1

    Looked like you was trimming a kebab not a lead pipe! Haha :p

  • @71dembonesTV
    @71dembonesTV 11 ปีที่แล้ว

    LOL Nice job!

  • @kevanrimmer3583
    @kevanrimmer3583 12 ปีที่แล้ว

    If you were GSR you'd know the answer to this, you're obviously not and shouldn't be putting other peoples lives at risk contemplating doing something so stupid, call a GSR person to advise you on the work you need doing - I'd suggest the ripping the lead out back to the meter and starting afresh with copper pipe, but you'll need a Gas Safe Registered person to do this as any work on a gas pipe legally requires a competent and registered person.

  • @socaljusticewarrior558
    @socaljusticewarrior558 3 ปีที่แล้ว

    I mean, they're banned for good reason, but damn if lead isn't an easy material to work with.

    • @ultimatehandyman
      @ultimatehandyman  3 ปีที่แล้ว +1

      Yeah, but I guess at the time it was all they had!
      Thanks for the comment 👍

    • @socaljusticewarrior558
      @socaljusticewarrior558 3 ปีที่แล้ว

      @@ultimatehandyman Prior to the steel revolution at the turn of the 20th century, it was either cast iron or lead. Cast iron is obviously not going to last very long, but it was the less expensive option.
      Lead has the advantage of being malleable. It was the Pex of its time, really. Chicago still has 700k lead lines in service, and it's highly doubtful that it's going to change any time soon. They've been talking about replacing lines for over 40 years, and they haven't gotten to it yet because Chicago is incredibly corrupt and dysfunctional

    • @ultimatehandyman
      @ultimatehandyman  3 ปีที่แล้ว

      @@socaljusticewarrior558 We also have a lot of lead pipes in my home town, although the utility company has replaced most of the main pipes (I believe). At my late mothers old house I once got a knock on the door from the utility company that wanted to test the tap water, the guy took a sample and said that lead does not leach from the pipes anymore, as they add a chemical to the water to prevent it 😱
      Thanks for the comments

  • @MrCinimod93
    @MrCinimod93 11 ปีที่แล้ว

    how do peopel not get sick that whole pipe should be replaced asap

    • @useyourbrain362
      @useyourbrain362 5 ปีที่แล้ว

      I'm going to guess the MSM has brainwashed you into not questioning what they are really saying.
      LIke the flint water fiasco '100,000 people have been exposed to lead.'
      1 part per trillion would make that statement true.
      They say they switched their water source to the flint river. Where did the lead come from? Oh. I mean lead the MSM tells you that is in the water.
      Oh, and you know pretty much every product you pick up is KNOWN (lol) to the state of california to cause birth defects.
      Fear mongering and manipulation is what my government loves to do.

  • @VickyKumar-oi2jl
    @VickyKumar-oi2jl 2 ปีที่แล้ว

    🇬🇧 🏳⚽️🌈👍🚲very good job 👍 thanks 👍

  • @kurluk04
    @kurluk04 4 ปีที่แล้ว

    Looks like 7lb lead 👍

    • @ultimatehandyman
      @ultimatehandyman  4 ปีที่แล้ว

      I can't remember now, but I'm glad I replaced the pipe with MDPE a few months later.
      Thanks for the comment 👍

  • @mrmmhxx
    @mrmmhxx 12 ปีที่แล้ว

    good thanks !!!!!

  • @gl7118
    @gl7118 2 ปีที่แล้ว

    Can not understand you

    • @ultimatehandyman
      @ultimatehandyman  2 ปีที่แล้ว

      Closed captions should be on the video 👍

  • @wingnut26261
    @wingnut26261 6 ปีที่แล้ว

    Dude shouldve cut that compression coupling too and just did the whole run from plastic to lead..or repipe the house

    • @ultimatehandyman
      @ultimatehandyman  6 ปีที่แล้ว +1

      The lead pipe was replaced a few days later ;-)
      Thanks for the comment

  • @metro2409
    @metro2409 6 ปีที่แล้ว

    Thank good vídeo i need to Fox m.i

  • @anthonyschneider8331
    @anthonyschneider8331 ปีที่แล้ว

    Ultimate handyman knows nothing about the proper connection from lead to copper. U need Ford fitting not compression

    • @ultimatehandyman
      @ultimatehandyman  ปีที่แล้ว +1

      Oh Dear, perhaps you could refrain from commenting on products that you don’t understand 😉

  • @WayneBurgess1
    @WayneBurgess1 12 ปีที่แล้ว

    :)