Checking on a gas pack Adjusting gas pressure with fieldpiece SDMN6. Abnormal flame caught on camera

แชร์
ฝัง
  • เผยแพร่เมื่อ 6 ต.ค. 2024
  • I was called out to this call because there was no heat in the morning. It later started to produce heat. I still checked on it. I adjusted gas pressure with the fieldpiece SDMN6. Found a very rusty heat shield, which I replaced. I also noted an abnormal flame in the first burner. #hvac #hvaclife #fieldpiece #rheem #SDMN6 #makita

ความคิดเห็น • 37

  • @GeminiSeven43
    @GeminiSeven43 6 วันที่ผ่านมา

    Nothing worse than piping or electrical boxes blocking panels....GRRRRRR!!!!!!! thank God for Cutoff saws and a little ingenuity. Thanks so much for taking us along on this one.

  • @k-laus9435
    @k-laus9435 8 หลายเดือนก่อน +2

    As a service manager now after being in the field for last 29 years the toughest thing to deal with is getting younger techs to take the effort to do the calls the RIGHT way. Taking the time and energy to check all of the unit like this heatexchanger inspection. The extra effort not to bail on it even though things like rotted screws get in the way. “Well I wasn’t there for that” is the go-to response when the call comes back in.

    • @camolance
      @camolance 6 หลายเดือนก่อน +1

      Wanting the techs to do a detailed checks on all calls is fine , but are the techs giving enough time to do all that or they are bambarge with calls , repairs and maintenance all in one day ?

  • @brianporter4352
    @brianporter4352 2 ปีที่แล้ว +4

    I work for a Rheem dealer in Burlington NC, and we service a lot of gas packs like this. I find that the stainless steel heat exchangers are very robust, but like you mentioned in the video, they tend to fail on the backplate. The radiation shield is a commonly replaced part, because they are a sacrificial lamb so to say. Always rusting out. We carry them as part of our truck stock. The Rheem/Ruud packs are very easy to work on though, and very easy to diagnose problems. Great video, thanks for sharing your knowledge. What you work on is pretty much what I work on here in NC

    • @HVACGUY
      @HVACGUY  2 ปีที่แล้ว

      Thanks for watching

  • @tyleraustin4720
    @tyleraustin4720 ปีที่แล้ว +2

    Hello sir I just want to thank you for posting this info. I learn from you're daily experiences as a relatively new tech. As a prior service member I see the attention to detail you share. Thanks again.

  • @1776cootsflybynight
    @1776cootsflybynight 2 ปีที่แล้ว +2

    I saw it! You have quickly became one of my favorite hvac channels. I was cleaning out my van this afternoon and was listening to an older video of yours where you had metallica playing in your van. Rock on 🤘

  • @boby115
    @boby115 2 ปีที่แล้ว +4

    I am a little concerned with your startup pressure. Next time you do this you should take pressures from both sides, Inlet and Outlet gas pressures on that valve. Sometimes the gas company has a problem with something called a creeping regulator ( when the unit is turned off the pressure on the inlet side should escalate a little bit and then lock up, we call this lockup pressure but in the event the pressure keeps escalating a little bit and a little bit more and a little bit more we call this a creeping regulator and the gas utility should be contacted about a possible pressure problem). Hope this information helps and stay safe out there 👍🛠.
    PS- you may want to use your CO2 condensate drain cleaner on the burner Venturis in order to clean any debris or spider webs🕸🕷.

    • @HVACGUY
      @HVACGUY  2 ปีที่แล้ว +5

      Thanks, I’m always open to help.

    • @boby115
      @boby115 2 ปีที่แล้ว +3

      @@HVACGUY , just sharing information and experiences. Thank you for sharing your experiences, knowledge and TH-cam content👍🛠.

    • @throttlebottle5906
      @throttlebottle5906 2 ปีที่แล้ว +2

      something looks fishy there for sure, I've seen bugs and people painting meters fill the regulator vent screens with paint/mud daubers and make it react very slow and over-pressure.
      for sure need to check incoming and manifold outlet, as that could be gas co. regulator or the gas valve itself. not good either way.

    • @boby115
      @boby115 2 ปีที่แล้ว +2

      @@throttlebottle5906 , you're absolutely right. I was a first responder / service technician 35 years for the full service gas utility in St Louis, Missouri and probably replaced well over 20, 000 Regulators in my career. Everything you said is all possible causes and one of the most common causes is as simple as debris on the regulator seat or a torn regulator seat ,this is why taking inlet pressures (lock up & working) is so important.👍🛠.

  • @realestateservicessaleshea99
    @realestateservicessaleshea99 2 ปีที่แล้ว +1

    That's close to condemnable from here ,looks like it's not gonna be to long before the scrap yard calls!🤔🤣
    Thanks again for the videos!
    🍺🍺🍺🥃🥃🎯🍿
    Retired (werk'n)keyboard super tech. Wear your safety glasses!

  • @jimsumner7360
    @jimsumner7360 5 หลายเดือนก่อน

    I guess I missed where you cleaned flame sensor, burners, brass orifice, vacuum port on draft motor 😂

  • @Parabellum-X
    @Parabellum-X ปีที่แล้ว +1

    That 2000, 3.5-ton gas pack had the most rusty-lookin coil I have ever seen.

  • @hughholt121
    @hughholt121 2 ปีที่แล้ว

    Nice work Bud. Another combo unit. Thanks for posting

  • @johnwalker890
    @johnwalker890 2 ปีที่แล้ว

    Good job Curtis.

  • @carlossaenz4075
    @carlossaenz4075 5 หลายเดือนก่อน

    U also need to do close up at to where u put the hose at the gas valve and the adjustment place

  • @thesilentonevictor
    @thesilentonevictor 2 ปีที่แล้ว +1

    Good work on this one

  • @ReliableHVACR
    @ReliableHVACR 2 ปีที่แล้ว +1

    Nice one

  • @Jack-ur6gx
    @Jack-ur6gx 2 ปีที่แล้ว +1

    I've had that happen to me on a conversion, gas pressure was too low. That low starting pressure likely issue, gas valve might be faulty.

    • @HVACGUY
      @HVACGUY  2 ปีที่แล้ว +1

      Yes, I agree.

  • @graymodeler
    @graymodeler 2 ปีที่แล้ว

    Might have been a spider web in the burner. I saw it too.

  • @stevealoia
    @stevealoia ปีที่แล้ว

    I seen a flash on the left burner

  • @joehead1294
    @joehead1294 2 ปีที่แล้ว +1

    Those bells ringing was kinda nice. Must be a church close by?

    • @HVACGUY
      @HVACGUY  2 ปีที่แล้ว

      Right across the street

    • @GeminiSeven43
      @GeminiSeven43 6 วันที่ผ่านมา

      That was the bells of doom for that gas pack....lol

  • @johnthomson3691
    @johnthomson3691 ปีที่แล้ว

    Compressor variable control

  • @seadeas
    @seadeas 2 ปีที่แล้ว +1

    👍

  • @hvaclifeatx7012
    @hvaclifeatx7012 2 ปีที่แล้ว +1

    👍🏻💯

  • @danbell1733
    @danbell1733 2 ปีที่แล้ว

    👍nice! Thank u

  • @carlossaenz4075
    @carlossaenz4075 5 หลายเดือนก่อน

    Burners need to cleaned !!!!!

  • @tomwalker9184
    @tomwalker9184 2 ปีที่แล้ว

    Is that coupling Allowed in the fire box area???

    • @HVACGUY
      @HVACGUY  2 ปีที่แล้ว

      Locally, yes. I think that gas code says different though.

  • @carlossaenz4075
    @carlossaenz4075 5 หลายเดือนก่อน

    Roll out