Naeem bhai main mohammad adil india 🇮🇳 se.Naeem bhai window ac ke pure system ko nightrogen se flush kaese karte hai uske upar bhi video bana dijiye bhai plz
❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤ mashallah zabardast bhaijaan naeem bhai nera naam bhi shahzad h India Delhi se kese h aap har video aap ki dekhte h ek question tha k aap ne iski gas west kyo nhi ki na outdoor flesh kiya mere Ac m choking huyi thi mene campressor cheng kiya tha but fleshing nhi ki phir dubara sari gas west ki or is tarha se fleshing ki so aap ne kyo fleshing ki campressor cheng kiya tha kiya ya bina cheng k bhi ye problem aajati h and aap ne outdoor kyo nhi fleshing kiya or gas west kyo nhi ki plzzzzzzzzzzzzz reply
Dost Jaruri hai kya aese case me Aaj indor hi chowk ho or outdoor sahi ho,,,kya chowking condition me jab ice luquid line per aa ja rhi thi tab guge miter stable tha ya variable please bataiye
Naeem bhai aap electronic expension valve ke upar video bnao uska kya kaam ho ta he kis trike se kam karta he our use kese check karte he ye sahi he ya kharab
Pls tell that after flushing how to check the recommended compressor oil level that should be in the system for proper lubrication of compressor parts for prolong life. Pls also tell me that after each gas leakage repair, is it necessary to makeup oil level and how much fresh oil should be added. Thanks
I have read it somewhere that half liter compressor oil is required in 1.5 ton AC. So in my view if a AC gets 2 to 3 times leak then oil make up become necessary otherwise compressor may get seized.
@@khawajajodat8763 wud yu also k ow a good tech icia. For hiar hi window 1.5tone who cud want capillary..change filtee inside in Delhi Mehrauli area nebe reasonable in his charges nd if gas doesnt then can he avoid gaa recharge lime in this vedio ..though they used the cylinder
Hello brother I am from India 🙏 Brother aapse request hai ki aap ek video banae capillary data per aur yah bhi bataen window mein aur split mein capillary data mein kya fark hota hai , Aur jab bhi aap capillary data ke bare mein bataen to yah bhi bataen capillary single line leni hai ya FIR double line leni hai 🙏 Brother aapse request hai 🙏 Deep freezer 600 litre mai evaporator ki length kitni honi chahie aur condensar mein length kitni honi chahie fit ke hisab se bataiye aur capillary data bhi bataiye Aur capillary kitni lagani chahie single ya double , aur compressor kaun sa lagana chahiye 🙏
I have some questions 1) Discharge valve of oudoor unit was closed while doing flushing?2) Can we do flushing of indoor unit with air by another compressor then attach the discharge pipe and do vaccum by vaccum pump? 3) There is a loss if compressor oil , if not added some oil in compressor will it not damage the compressor?
Mere ac ka b same issue ara tha but koi b techician ka dhyan choking line par nahi gaya muje wo ac change karna pada kash yeh video mai pehle dekh pata mere hazaro rupees bach jate
Mashallah sir G Boht khoob AUR humesha k trah yeh video b zbrdast hy ❤️👍
Sir ma india cy ho pr lekin ma bi electricain hu bt ma app cy bout kush sekhny ku mila thnku so much ji
Masha Allah bohat khoob samjhaya ji Thank's
Zabardast perfect work bhai 👍
Nice sir ji bhut ache se samghaya hai aap ne
Asalmoalikum Bhai Masha Allah zaberdast video ha Allah AP ko kush the Bhai
Wah. Kya baat agar aapki shop india delhi me hoti to mai aapke sath hi kaam karta.
Bahut accha samjhaya sir apne 👌
Sir kaha se hai aap
Mashallah Naeem bhai zabardast
Ya kasy pata k indor mai hi choking Han outdoor mai be to ho Sakti Han choking caplari k ander ya filter mai
Gd question
Bahut hi acha sir.
Buhat khub jabardast 🎉
Thank u brother so much for help
Bohot bohot sukria
super idea 👌👌👌bro
Pa g tusi great ho azeem loogu k azeem kam
Shukriya Naeem bhai is jankari k liye N2 se bhi kar sakte h
Thanks vai
Sir, outdoor unit ko flushing nahi krna tha...yeh B toh ho sakta hai k is k caplery b chocking kr raho ho
Bhai us ny just indoor ki chocking thk ki ha
Outdoor ki Chocking next video me
Hahahaha us ka wait kryn 😅
Naeem bhai 1 outdoor 2 indoor system bane video upload keren shukria
Thank you sir❤
Tkanksssssss deear brooooo .❤🤲❤
Hi vhai🖐️ I am from Bangladesh ❤️
Very good video Bhai jaan
Very good Sir
zabardast ustad
Very good work
Nice video Sir 👌👍
Naeem bhai👍👍
Laken hamen kasy pta chaly ga k chocking indoor me he ha.
Or meter ki nidle b ni hill rahi the?
Gas ka pressure chocking me Kam ho jata ha?
Good job 💯
Super sir 👍👍👍👍👌👌👌👌👌💯💯💯💯
Good information ℹ️
Thank you sir
Good information
very good job
Ma Sha Allaah ❤
Bhai fleshing nitrogen se bhi to kr sakte the gas se hi kio ki iske bare me bataiyega.
Badhiya hai g
Aap nitrogen use kar sakte the..
Naeem bhai main mohammad adil india 🇮🇳 se.Naeem bhai window ac ke pure system ko nightrogen se flush kaese karte hai uske upar bhi video bana dijiye bhai plz
Good bahi Jan ilove
R jo gass bich may majud hai wo zaya kr ke new enter bhi kr sakta hai ya use save kr ke istamal kr ly bad my?
Sir ji gas ke badle me hum vacum bhi istamal karsakte he kiy please batao Bikram odisha
❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤ mashallah zabardast bhaijaan naeem bhai nera naam bhi shahzad h India Delhi se kese h aap har video aap ki dekhte h ek question tha k aap ne iski gas west kyo nhi ki na outdoor flesh kiya mere Ac m choking huyi thi mene campressor cheng kiya tha but fleshing nhi ki phir dubara sari gas west ki or is tarha se fleshing ki so aap ne kyo fleshing ki campressor cheng kiya tha kiya ya bina cheng k bhi ye problem aajati h and aap ne outdoor kyo nhi fleshing kiya or gas west kyo nhi ki plzzzzzzzzzzzzz reply
Air pressure sa bhi hojata. Gas kyu zaya ki?
Dost Jaruri hai kya aese case me Aaj indor hi chowk ho or outdoor sahi ho,,,kya chowking condition me jab ice luquid line per aa ja rhi thi tab guge miter stable tha ya variable please bataiye
Very good 👍
Outdor kaha se clean hua
Asalamwualaikum Neem bhai nitrogen ka istamal bhi ho sak ta tha
Thank u
Bhai jab chowking problem thi to aapne gas kese lock kari outdoor me🤔🤔🤔🤔 back pressure to a hi nhi ra hoga
very bad see your safety first it will harm envirment and also your hand
Very nice
Ap ke ladke badiya kam karte hai
Alki wall bai dono of rakhne hai?
Agar R410 gas ho to aise hi flash kar sakte hai plz reply
Very good 🙂
Very good
نعیم صاحب دی گریٹ۔ آپ کی ویڈیوز بہت آسان فہم اور ڈیٹیل کیساتھ ہوتی ہیں۔ آپکا جناب نمبر کیا ہے
vip ustad
First view first comment
Use nitrogen gas for flushing the pipe line. Vaccum the unit and gas charge.
Nigegeon and plushing and us last use bai R22..R11.ues and last which gas same use checkup goodflushing ga good vacune and charge solved..
Good video sir 👍
Thanks
bhi services valve band kr kaa flash karna ha indoor agr chock ho to
Oil kam ho gaya iska kya? Naya add on kiya?
❤❤❤❤❤❤ sir kya aap ne leakage test Kiya tha aap ne nhi kyo ki pressure 20 psi tha
Naeem bhai aap electronic expension valve ke upar video bnao uska kya kaam ho ta he kis trike se kam karta he our use kese check karte he ye sahi he ya kharab
Dear channel par already video mojood ha, kindly watch it
Assala mu alaikum bhai app ki video bahut dino ke baad aati hai aap jaldi jaldi video dala karo
Wa Alaikum Assalam
Will try
Nice bro
ya kesy confirm kya k oil choking he ha ? capillary be tu chock ho skti ha ??
Package unit ka full wiring ka bare ak video upload koriye
Llyod new inverter ac me vaccum krna zaruri h
Sir iski piping kitni meetar thi or gas kitni lagi isme plz bataye super video from india
10 ft pipe length
Half kg gas used aprox.
Gas nkalne k baad oil charge ni krna hota???
Mere pas haier ka dc inverter ac hai...
Kia gas k sath oil bhi charge krna hota hai??
Pls tell that after flushing how to check the recommended compressor oil level that should be in the system for proper lubrication of compressor parts for prolong life. Pls also tell me that after each gas leakage repair, is it necessary to makeup oil level and how much fresh oil should be added. Thanks
Ooo bhi is ma itna ni hota agar lek zada ho to oil chak kar lo
I have read it somewhere that half liter compressor oil is required in 1.5 ton AC. So in my view if a AC gets 2 to 3 times leak then oil make up become necessary otherwise compressor may get seized.
I'm an engineer and as per my knowledge at least 500ml compressor oil is required in 1.5 ton AC.
@@khawajajodat8763 wud yu also k ow a good tech icia. For hiar hi window 1.5tone who cud want capillary..change filtee inside in Delhi
Mehrauli area nebe reasonable in his charges nd if gas doesnt then can he avoid gaa recharge lime in this vedio ..though they used the cylinder
Capalary flashing nahi karte kya
Agar filter chok huaa tab?
Ek baat btaye mujhe jab aapne Suction line se charging pipe jode to L-key se Suction valve ya discharge valve kholna ya nhi??
Dono ko off hi rakhna hai
Hello brother I am from India 🙏
Brother aapse request hai ki aap ek video banae capillary data per aur yah bhi bataen window mein aur split mein capillary data mein kya fark hota hai ,
Aur jab bhi aap capillary data ke bare mein bataen to yah bhi bataen capillary single line leni hai ya FIR double line leni hai 🙏
Brother aapse request hai 🙏
Deep freezer 600 litre mai evaporator ki length kitni honi chahie aur condensar mein length kitni honi chahie fit ke hisab se bataiye aur capillary data bhi bataiye
Aur capillary kitni lagani chahie single ya double , aur compressor kaun sa lagana chahiye 🙏
Hi mester shirzad
My job is hvac system can I use of LPG capsoul for flash system
Sir N2 se kr sakate h ky???
Reply me
Good
Thank you 💕
Nice pogram.excellent.
Zbrdast
Mashallah & jazakallah 😊
❤jajakallha khairan
I have some questions 1) Discharge valve of oudoor unit was closed while doing flushing?2) Can we do flushing of indoor unit with air by another compressor then attach the discharge pipe and do vaccum by vaccum pump? 3) There is a loss if compressor oil , if not added some oil in compressor will it not damage the compressor?
Good qustion
Nice
System ko vacuum kyon nahin kiya bhai isase bhi problem a sakti hai
बहुत सुन्डर
Naeem bhai mera ak sawal hy ap sy agr kisi ac pr nahe likha howa k iss ma kn si gass dalny hy pr humain kisy pta chaly ga k iss ma kn si gass dlly gi
Nice 👍
Outdoor nhi hoga clean ise
Acha ji
Sir job to sahi hai magar aap ne N2 (nitrogen) gas se flushing karna or bhi sahi rahta
Apse Kam sikhne ka moka milta kash 🥰
Naeem bhai dobara chek karwsna tha
Mere ac ka b same issue ara tha but koi b techician ka dhyan choking line par nahi gaya muje wo ac change karna pada kash yeh video mai pehle dekh pata mere hazaro rupees bach jate
Gas lock krke indoor or outdoor unit ko vacume kr skte h???
Gas lock krke only indoor or uski piping vaccum ho payegi
Outdoor vaccum k liye outdoor pura khaali chaiye no gas
Kya R22 gas se flushing kr skte hi.. environment k liye r22 ka bahr air k sath mixed ho jana sahi hi
R22 me koe problem nhi ati agr bahar ki air mix jo jayegi to
Haa lekin thodi bahut
Very Very much