Bohat hi wadia video sir aap ne to ek ek chiz badi bariki se btai,baki chanels wale kam kush kar ke btate nahi or muh se hi bol bol ke bakwas marte rehte hai or bolte hai ke video jada lamba ho jata,lekin aap ne bohat hi ashe se btaya very nice.
It is always great to see good repairs. In Australia the smallest problem means replacing everything. The refrigerant gas is so expensive here, repairs are not economical. I looked it up today: in Australia it is $AUD150 per kilo for R410a, 23 times more expensive than India. Imagine throwing away installed units, just because of the high gas price. All that copper, the compressor, all the electronics, all gets junked. What a waste of carbon.
All the units can be repairable and will work perfectly OK. Throwing the units is a waste. But how will AC companies make money? Also R22 gas is the best and most efficient gas for refrigeration but is banned just because companies wanted to sell expensive gases. Deplation of Ozone layer is not proved scientifically.
Sir app key video muje bohat assa laga.... Sobche asslagi ap ne jo olding gun key matha mey sapport sit cipak diye o bohat barriya idea.... Thank you sirji
सर जी बहुत बहुत धन्यवाद बहुत ही मस्त वीडियो बनाया मुझे लगा गैस बेल्डिंग में समय खिंच गया नही तो ओर भी कुछ नया देखने को मिलता आप स्वास्थ्य सुखी रहें शुभकामनाएं ।
You are a great technician with a great teaching skill. Does the compressor come with oil? Do I add oil through suction line or discharge line of the compressor provided the compressor is empty?
Please use nitrogen flow when you do the brazing, and also keep wet cloth for covering electrical, and for accumulator, I am Indian I have 30 years of experience, right now I am in New Zealand,
@ravind singh Check your capacitor first, check condenser coil for blockage, check condenser fan motor, remove all refrigerant from the system, weight the gas, and check for manufacturer details, probably over charged gas,
Sir, Which one is good Brand in terms of reliability in long run sir GMCC, whirlpool & bluestar. am converting my inverter ac to non inverter ac so am in the process of buying new compressor and whichone would be best choice and R-22 or R-32 ?
Allah tumhe salamat rakhe mere bhai bahot achhi information di aap ne ❤❤❤❤Bhai ac choking hai ya nahi kaese pata kare clamp metar ke zariye or clamp metar na ho to kaese pata kare bhai is par bhi video bana do
Hi friend, I have a question and would appreciate a lot if you would answer. I have an Inverter AC Hisense Energy Pro Plus that is really good and powerful, but it is installed in a small room (20 square meters) so when temperatures outside are above 8 degrees celsius AC heats the room quickly, and AC goes into stand by mode because it cannot modulate power below 400w. When it's even warmer outside +10 C and above, the ac goes into these standy mutiple times in a day, sometimes even 3-4 times in an hour. My question is, are those freequent stand by and compressor shutting off and powering on bad for ac lifetime ? can it cause failure over time or this has little or no impact on AC lifetime ?
Frequent cycling of an air conditioner, where it goes into standby mode and the compressor shuts off and powers on multiple times, can indeed have an impact on the unit's lifetime, although the severity of this impact can vary depending on several factors. Compressor Wear: The compressor is one of the most critical components of an air conditioner, and frequent cycling can lead to increased wear and tear on this component. Each time the compressor starts up, it undergoes a surge in electrical current and mechanical stress, which can contribute to its deterioration over time. Electrical Components: In addition to the compressor, other electrical components such as relays, capacitors, and contactors may also experience increased stress with frequent cycling. Over time, this can lead to component failure. Efficiency and Performance: Frequent cycling can also impact the overall efficiency and performance of the air conditioner. When the unit repeatedly cycles on and off, it may not have sufficient time to effectively dehumidify the air or maintain consistent temperatures, leading to discomfort and potentially higher energy consumption. Refrigerant Issues: Rapid cycling can also affect the refrigerant system, potentially causing fluctuations in pressure and temperature within the system, which may impact its overall performance and efficiency. While occasional cycling is normal for air conditioners, excessively frequent cycling, as you described, can accelerate wear and potentially shorten the lifespan of the unit. However, it's essential to consider that modern air conditioners are designed to withstand a certain degree of cycling, and their lifespan can be influenced by various factors, including maintenance, usage patterns, and environmental conditions. To mitigate the impact of frequent cycling and ensure the longevity of your air conditioner, consider the following steps: Optimize Settings: Adjust the temperature settings to minimize the frequency of cycling while still maintaining comfort. Proper Sizing: Ensure that the air conditioner is appropriately sized for the room. Oversized units can cycle on and off more frequently in smaller spaces. Regular Maintenance: Keep the air conditioner well-maintained by cleaning or replacing filters, checking refrigerant levels, and scheduling regular professional inspections. Consideration for Replacement: If frequent cycling becomes a significant issue and significantly impacts comfort or energy efficiency, you may consider upgrading to a unit with better modulation capabilities or seeking alternative solutions such as additional insulation or shading to reduce heat gain in the room. Overall, while frequent cycling can impact the lifespan of an air conditioner, proper maintenance and considerations for usage can help mitigate these effects and ensure optimal performance and longevity.
Aap ne mistake ki hai discharge joint ke time terminal par Gila kapda rakhna tha aur capplery aur stainor change Karna tha you are a best technition but some things is wrong
Nice, two questions please: 1_ are new compressors already filled with gas or you have to fill them? 2_ could anyone please give us information about the torch he is using and the rods? Thanks
compressor don;t come filled with gas. we have to fill later after fixing to system. and this torch is made in india. PKL kabson. and rod is copper breezing rod
@@SomaElectricals ha ye baat pata hai mujhe par jaise aapne bhi is video me position change kiya na compressor ka kya us tarike se nahi ho sakta hai means agar copper pipe align ho jaye to baki jaise aapne kiye vaise ho jana chahiye na
unfortunately, you unintentionally ignored some steps of the process 1. You didn't wash the line of condenser and evaporator coil (to clean from the previous compressor oil) 2. the way of welding is a bit weird I admire your work more power on your muscles
Mere pas nitrogen avelebal nahi he tho kya ham likej check karneke liye dusare fridge ke compressor se pressure testing kartehe kya ager tho koi dusra idea ho jese ki indoor me tho gas 200gram dal ke and outdoor me gas pressure se testing kare please batana
from Saudi 🇸🇦 Arabia
I am saying thank you very much
You are welcome
hi soma❤❤
Bohat hi wadia video sir aap ne to ek ek chiz badi bariki se btai,baki chanels wale kam kush kar ke btate nahi or muh se hi bol bol ke bakwas marte rehte hai or bolte hai ke video jada lamba ho jata,lekin aap ne bohat hi ashe se btaya very nice.
thank you
Sir apki video me kuch naya dekhne ko milta hai THANK YOU SIR
It is always great to see good repairs. In Australia the smallest problem means replacing everything. The refrigerant gas is so expensive here, repairs are not economical. I looked it up today: in Australia it is $AUD150 per kilo for R410a, 23 times more expensive than India. Imagine throwing away installed units, just because of the high gas price. All that copper, the compressor, all the electronics, all gets junked. What a waste of carbon.
may be AUS govt eco friendly 😂😂
@@SomaElectricals hi
Damn, that shouldn't be happening 💔 being a hvac tech i feel those junk units are so valuable
All jobes must sfltey need mustok
All the units can be repairable and will work perfectly OK. Throwing the units is a waste. But how will AC companies make money? Also R22 gas is the best and most efficient gas for refrigeration but is banned just because companies wanted to sell expensive gases. Deplation of Ozone layer is not proved scientifically.
Bro your brazing kit is amazing...
you guys are amazing workers🙏🏼👍👍👍
Very nice demonstration. Hats off
thank you
Sir app key video muje bohat assa laga.... Sobche asslagi ap ne jo olding gun key matha mey sapport sit cipak diye o bohat barriya idea.... Thank you sirji
thank you
Nice work buddy
Ekdam super sir aapka samjhane ka tarika achha hai 👌👌👌
thank you
सर जी बहुत बहुत धन्यवाद बहुत ही मस्त वीडियो बनाया मुझे लगा गैस बेल्डिंग में समय खिंच गया नही तो ओर भी कुछ नया देखने को मिलता आप स्वास्थ्य सुखी रहें शुभकामनाएं ।
You are a great technician with a great teaching skill. Does the compressor come with oil? Do I add oil through suction line or discharge line of the compressor provided the compressor is empty?
compressor will come with oil filled
Nice ... Very simple way
Please use nitrogen flow when you do the brazing, and also keep wet cloth for covering electrical, and for accumulator,
I am Indian I have 30 years of experience, right now I am in New Zealand,
@ravind singh
Check your capacitor first, check condenser coil for blockage, check condenser fan motor, remove all refrigerant from the system, weight the gas, and check for manufacturer details, probably over charged gas,
Sir, Which one is good Brand in terms of reliability in long run sir GMCC, whirlpool & bluestar. am converting my inverter ac to non inverter ac so am in the process of buying new compressor and whichone would be best choice and R-22 or R-32 ?
GMCC
Sir boht hi nice video ha very informative video ha
Sooper,man
Thank you so much
Nice work flip flops.
Sir thanks a lot for nice vdo
Most welcome
Good good very good sir ..🖒🖒🖒
Thanks and welcome
Nice jop brooo well done
Very Nice Video Sir
You Explained Like An ITI Instructor
Jai Hind ❤️
Allah tumhe salamat rakhe mere bhai bahot achhi information di aap ne ❤❤❤❤Bhai ac choking hai ya nahi kaese pata kare clamp metar ke zariye or clamp metar na ho to kaese pata kare bhai is par bhi video bana do
Super...work fantastic
Thank you so much 😀
Excellent job 👍
Good work systematic work for you i liked new macanic usebal video
Keep watching
great job bro .. i was looking for that video .. thank u
Welcome 👍
Speak&transalate every clear I understand it everygood.
Nice video sir
Bahut achi knowledgeable video aap banate hain
Thanks sir
Good job bro ,cool cool cool ,salam dingin froom jogjakarta indonesia
Bahut Achhhaa Video Sir
Bahut badhitya.
Very good! Thanks
Thank you for this video
I have one question
After replacing compressor by new one is it need to fill it by oil or NO need?
My best wishes for you.
No need. factory oil charged
Welcome gues tjankyu boss
Bahutt..vadia.jankari
thank you
Bhai jordar kam kar rahe ho duwa lagegi aapko sikhane ke liye.👌👌🙏🙏🙏 bhai wiring diagram kaise chek karte hai wo bhi video banaye sir
ok jaroor
Very nice sir
Keep watching
Very nice work. Thank you for sharing such valuable lesson.
Glad you liked it!
Thanku so much brother
Welcome
Hi friend, I have a question and would appreciate a lot if you would answer. I have an Inverter AC Hisense Energy Pro Plus that is really good and powerful, but it is installed in a small room (20 square meters) so when temperatures outside are above 8 degrees celsius AC heats the room quickly, and AC goes into stand by mode because it cannot modulate power below 400w.
When it's even warmer outside +10 C and above, the ac goes into these standy mutiple times in a day, sometimes even 3-4 times in an hour. My question is, are those freequent stand by and compressor shutting off and powering on bad for ac lifetime ? can it cause failure over time or this has little or no impact on AC lifetime ?
Frequent cycling of an air conditioner, where it goes into standby mode and the compressor shuts off and powers on multiple times, can indeed have an impact on the unit's lifetime, although the severity of this impact can vary depending on several factors.
Compressor Wear: The compressor is one of the most critical components of an air conditioner, and frequent cycling can lead to increased wear and tear on this component. Each time the compressor starts up, it undergoes a surge in electrical current and mechanical stress, which can contribute to its deterioration over time.
Electrical Components: In addition to the compressor, other electrical components such as relays, capacitors, and contactors may also experience increased stress with frequent cycling. Over time, this can lead to component failure.
Efficiency and Performance: Frequent cycling can also impact the overall efficiency and performance of the air conditioner. When the unit repeatedly cycles on and off, it may not have sufficient time to effectively dehumidify the air or maintain consistent temperatures, leading to discomfort and potentially higher energy consumption.
Refrigerant Issues: Rapid cycling can also affect the refrigerant system, potentially causing fluctuations in pressure and temperature within the system, which may impact its overall performance and efficiency.
While occasional cycling is normal for air conditioners, excessively frequent cycling, as you described, can accelerate wear and potentially shorten the lifespan of the unit. However, it's essential to consider that modern air conditioners are designed to withstand a certain degree of cycling, and their lifespan can be influenced by various factors, including maintenance, usage patterns, and environmental conditions.
To mitigate the impact of frequent cycling and ensure the longevity of your air conditioner, consider the following steps:
Optimize Settings: Adjust the temperature settings to minimize the frequency of cycling while still maintaining comfort.
Proper Sizing: Ensure that the air conditioner is appropriately sized for the room. Oversized units can cycle on and off more frequently in smaller spaces.
Regular Maintenance: Keep the air conditioner well-maintained by cleaning or replacing filters, checking refrigerant levels, and scheduling regular professional inspections.
Consideration for Replacement: If frequent cycling becomes a significant issue and significantly impacts comfort or energy efficiency, you may consider upgrading to a unit with better modulation capabilities or seeking alternative solutions such as additional insulation or shading to reduce heat gain in the room.
Overall, while frequent cycling can impact the lifespan of an air conditioner, proper maintenance and considerations for usage can help mitigate these effects and ensure optimal performance and longevity.
Excellent 👍
Thanks for the visit
Very Good Job 😎
Good job.
Thanks!
Aap ne mistake ki hai discharge joint ke time terminal par Gila kapda rakhna tha aur capplery aur stainor change Karna tha you are a best technition but some things is wrong
THANK YOU SO MUCH!!!
You're welcome!
Nice, two questions please:
1_ are new compressors already filled with gas or you have to fill them?
2_ could anyone please give us information about the torch he is using and the rods?
Thanks
compressor don;t come filled with gas. we have to fill later after fixing to system. and this torch is made in india. PKL kabson. and rod is copper breezing rod
No sir there is no filled gas in new compressor .
You have to fill gas ok
@@SomaElectricals how many R410a is needed to fill the compressor?
@@rockraholy2298 depends on ac models, u can see in outdoor sticker
Your work is good thank
Nyc video sharing!
Thanks for visiting
nice bai replace compressor
Hii
Good video 👍
Voltas ka 1.5 ton ka compressor price kya hai
8600rs
Very good
great work!!!!!
thank you
I am impresh in your work so I tried to learn sir
All the best
@@SomaElectricals Ek bat batao 0.8 ton ya 1 ton wale model me 1.5 ya 2 ton ka compressor lag jayga na,
kyunki pipe ki jagah to same hogi..
@@RamSharma-90_64 nahi laga saktey . kuon her compressor ka outdoor condesor and indoor ka design alag alag hota.
@@SomaElectricals ha ye baat pata hai mujhe par jaise aapne bhi is video me position change kiya na compressor ka kya us tarike se nahi ho sakta hai means agar copper pipe align ho jaye to baki jaise aapne kiye vaise ho jana chahiye na
@@SomaElectricals aur vaise 1 ton compressor aur 2 ton compressor ki price me kitna difference hoga
Nice job
Great tutorial... thx
Apki tips bahut achihe bhai ac me indoor mejerment kese karke leval botal se kese fitting kare us ka koi idea do
Super sir thanq
Nice 👌 video
Very good 🙏🙏🙏
Thank you! Cheers!
Very nice ji
Thanks
Sir good video ...but ap ny system flash nahi kia??
flushing ka video dusara hai
@@SomaElectricals Wow😁
Brother sometime compressor have default so before brushing must be check pressure for the compressor
@ravind singh change capacitor I
Point point sir
When we have to chek tha pressure before opening the cover or something else
Sir o reciver nahi he ...Accumuleter he reciver Commersial me use karte he 😋 dekne me bahat bara hota he 😋
sir, in replacing a compressor, is BTU need to address? or the LRA?
ok
Soma Electricals
ok what?
@@renantejosesiguiente1442 LRA
Good luck
Sir duba katar se bi cut kar sak te the naa but aisaa q kiyaa ?
Nice video
आपने एक स्टेप लोगों को नहीं बताया ओह है जब आपने न्यू कंप्रेसर सर का रबर निकाला तो जो एयर इंपोर्टेंट क्या है
good explanation good experience me sir thanks so much for the video sir
Always welcome
Kya 2ton non inverter voltas ac mein Lg ya kisi aur brand ka compressor laga sakte hain?? Voltas ka compressor bohot aawaz karta tha.
haan laga saktey hain. compressor 2 ton ka hona chahiye
is it possible to place an 48v ac compressor instead, not inverter ?
yes it can be
Super
Thanks
Thank you for this video. Nice job! Greetings from Germany :-)
R22 system me R32 ka compressor laga sakte hai??
yes laga saktey hain
I like the protection torch on your tool. What’s the name
flame deflector
unfortunately, you unintentionally ignored some steps of the process
1. You didn't wash the line of condenser and evaporator coil (to clean from the previous compressor oil)
2. the way of welding is a bit weird
I admire your work
more power on your muscles
u sure might find it weird, but still in India that's the regular process (with good accuracy)
THANKS
You're welcome!
Mashallah ❤️
Very nice but u have no change the filter and capalry change
paka
Brother ap ka torch ka refillable cylinder ka link desaktha kya ? very good video 🙏👍
ye online nahi milta hai aap spare parts shop main check karo clix torch and cylinder
@@SomaElectricals ok bhai thank you 🙏👍
Mere pas nitrogen avelebal nahi he tho kya ham likej check karneke liye dusare fridge ke compressor se pressure testing kartehe kya ager tho koi dusra idea ho jese ki indoor me tho gas 200gram dal ke and outdoor me gas pressure se testing kare please batana
aap dusrey compressor say air bhar kay bhi test kar saktey. ya nahi tho r32 ya r410 dal kar bhi leak test kar saktey ho
Sir nice work kya hum r32 ki jagah r22 ka compressor LGA sakte hai
haan laga saktey ho. but ac non inverter hona chahiye
@@SomaElectricals sir kya cappilary ka data same hota hai
Nice
Thanks
Cost of new compressor gree 1ton ac or is it worth to get the sec hand compressor. .? Please bta den hm bht preshan Hain
better buy new compressor i will cost around 7000rs
@@SomaElectricals I can't afford new ... Can I go for sec hand...?
@@daydreamer8943 yes
@@daydreamer8943 used u will get around 2500 with old replacement
Sir, which city are you located?
@@raghuarmani8341 sir I m ac ticnetion from kpk bunir is a time I m jelam Panjab cergat pectree
❤❤❤❤❤
hyderabad
क्या ब्रेजिंग राड के साथ फ्लक्स (बोरेक्स) इस्तेमाल करना चाहिए।
copper to copper joint kay liye jaroorat nahi hai. cooper to iron kay liye flux use karna padtha hai
Kon sa compressor
GMCC ka compressor hai
nice video....
Sir pls tell I have Hitachi 1.5 ton window AC kya aap bata sakte hai ki uska compressor kite tak ka pad jayega?🙏
12000 tak with fitting and gas filling
Nice jankari sir
Hi
What is Price of Compressor AOGG12JLCA ogeneral Ac 1.0 T ? Pl
O general not available u need to fix another company compressor, the cost will be around 7500 only compressor price fix and gas filling will be extra
Mst Videos hhh Sir,,,, But
Bhai sirf rubber bush change karne ke liye bhi compressor ko nikalna parega
kar saktey hain thoda muskil hoga
Sir voltas 1.5 ton inverter AC ka compressor kitne ka price hai aur kaun se brand ka compressor achha hoga ?
inverter compressor abhi market main nahi mil raha hai. aap ko company say lena padega per wo nahi sale kartey aap ko unsay hee replace karwana padega
Good
Sir ji R32 सिस्टम r 22 का compressor लगा सकते हैं क्या
yes laga saktey hain non inverter AC hona chahiye
Thanks
Ap welding set use karare?
Sir where is your workshop?
Hyderabad
Sir me AC technician hu me bhi kam karna chata hu apke pass Hyderabad mein my number 9910753138 sir reply please bhut jarurat he kam ki
5 sal hogae kam karte karte me main Hyderabad mein karna chahta hu