My alarm system will not stop beeping how do I shut it off Honeywell

แชร์
ฝัง
  • เผยแพร่เมื่อ 29 ม.ค. 2022
  • This will show you how to stop the beeping from your alarm panel and maybe help figure out what the problem that caused it was.
    VISTA-20P
    VISTA® Control Panel
    The high capacity, feature-rich VISTA-20P lets you deliver more value to your customers on each and every sale with up to 48 zones of protection, Internet uploading/downloading, graphic keypad support and dual partitions. VISTA-20P gives you the ability to send alarm signals and upload/download via an Internet Protocol (IP), improving the speed at which information can be delivered to and from the control panel. In addition, the VISTA-20P, used with an AlarmNet® Internet or LTE communicator can be installed in premises without TELCO lines. The panel’s installation advantages, innovative end-user benefits and robust system capacity make the value-priced VISTA-20P an ideal choice for higher end installations.
    Features
    Documents
    Ordering Info
    Related
    IP alarm reporting and uploading/ downloading capability for Internet and Intranet use via iGSMV4G, 7845i-ENT, GSMV4G or GSMX4G
    Supports four graphic touchscreen keypads
    Wireless keys can be programmed without using zones
    Eight on-board hardwired zones standard (15 when Zone Doubling feature is used)
    - 40 hardwire expansion zones
    - 40 wireless expansion zones
    Two low current on-board trigger outputs
    100 Event Log viewable at system keypads with time/date stamp
    48 system user codes assignable to either partition
    Expandable to 48 total zones when used with hardwired and/or wireless expansion modules
    Two independent partitions plus a common partition
    - Global Arming from any system keypad
    - Go to function to view or operate one partition from the other
    - Separate partition account numbers
    16 output devices
    - Relays (Model 4204 Relay Modules, or 4229 Expansion Module)
    Four installer-configurable zone types allows the installer to create custom zone types by assigning all zone attributes
    Supports four-wire and up to 16 two-wire smokes
    - Works with Sentrol CleanMe™ maintenance signal
    Multiple actions on output devices depending on system state
    - Turns lights off when system arms
    - Turns the same light on when system disarms
    - Flashes same lights when system is in alarm
    Built-in phone line cut monitor with programmable delay and annunciation options
    - Display on system keypads
    - Trigger local sounders
    - Trigger system bell
    Security Dealer Features
    Automatic System Load Shed
    - During extended AC power fail, the system battery will be disconnected to prevent irreversible battery failure. Reduces service calls to replace batteries.
    Dynamic Signaling
    - Reduces redundant reporting to the central station when multiple reporting methods are used; i.e. digital dialer and AlarmNet radio
    Valuable End-User Features
    Viewable on system keypads:
    - Exit countdown
    - Time and date display*
    - Event log*
    Auto keypad backlighting on entry
    Keyswitch arming
    Programmable macro buttons and single-button arming
    Supports a variety of wireless remote controls for single-button operation
    User Scheduling
    - Latchkey reports to pagers
    - Auto arm/disarm
    - “User access” time windows
    VIP Module allows system control from any touchtone phone
    Chime by zone
    *Requires custom alpha keypad
    6160
    Alpha Display Keypad
    The 6160 Deluxe Keypad is easy to install and simple to use. The attractive white
    console blends with any décor and features a contoured, removable door that
    conceals illuminated soft-touch keys. The 6160 also features a new larger and
    brighter 32-character display with easy-to-read plain-English status messages.
    The oversized function keys are easily accessed even when the keypad door is
    closed, and can be programmed for fire, burglary, personal emergencies and other
    operations. Colored self-adhesive labels are included.
    FEATURES AND BENEFITS
    • Large, easy-to-use keypad
    • Keys continuously backlit for greater
    visibility
    • Speaker with audible beeps
    to indicate:
    - System status
    - Entry/exit delay
    - Other alarm situations
    • Zones and system events displayed
    in plain English
    • No confusing blinking lights
    • Four programmable function keys
    • System functions clearly labeled
    • Functions performed by just entering
    security code plus command
    • White with removable door blends
    with any décor
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 8

  • @msmissygrl974
    @msmissygrl974 หลายเดือนก่อน

    It worked! Thank you! It was getting on my nerves!

  • @hannahpuff-basketball2154
    @hannahpuff-basketball2154 ปีที่แล้ว

    thanks for the help!

  • @ADAyINFLorida
    @ADAyINFLorida 10 วันที่ผ่านมา

    It didn’t fix my issue I don’t even have a system I moved in and it was here it beeps every few minutes super annoying

  • @copetv43
    @copetv43 ปีที่แล้ว +4

    My screen says nothing

  • @user-em9cr8pg7n
    @user-em9cr8pg7n 6 หลายเดือนก่อน

    Local retailors selling an Honeywell Carbon Monoxide Alarm XC70

  • @cavitycreep
    @cavitycreep ปีที่แล้ว

    remove it