Why V/F Ratio is Maintained Constant in VFD | Variable Frequency Drive | Hindi

แชร์
ฝัง
  • เผยแพร่เมื่อ 26 ส.ค. 2024
  • Queries Solved:
    1. Why V/F Ratio is Maintained Constant in VFD.
    2. Variable frequency drive.
    3. Torque in induction motor.
    Hello friends in this video we discussed about motor, Transformers, Power system and electrical system in the simplest way possible.
    About channel:
    In this channel we cover the topic like Machines, Power system and general electrical in the simplest way possible.
    #variablefrequencydrive
    #inductionmotor
    #Interview
    #electricalwithabhishekjoshi
    Kindly subscribe.
    Thank you.

ความคิดเห็น • 68

  • @sahilhirapara6969
    @sahilhirapara6969 2 ปีที่แล้ว +12

    very informative sir, I wanna add something v/f ratio is proportional to flux density if we not constant flux density hysteresis loss in motor core increases because in case of flux density not constant hysteresis loss inversely proportional to the frequency and proportional to the voltage, means if we run motor at normal voltage at low frequency that cause heating in the motor this is also can be a reason. if we constant v/f ratio hysteresis loss is proportional to the frequency.

    • @rahulkv7976
      @rahulkv7976 2 ปีที่แล้ว

      That's the point

  • @jaydevbhadreswara423
    @jaydevbhadreswara423 2 หลายเดือนก่อน

    Thank you sir for most help
    Sir. when I gave the interview I was afraid because I had full knowledge but I could not explain that knowledge fully
    So how to remove Fear in interview. Please make a video related remove fear in interview.

  • @scitechpedia168
    @scitechpedia168 4 หลายเดือนก่อน

    Superb, Excellent and informative video with Knowledgeable Person..keep it up

  • @abdullahzafar1704
    @abdullahzafar1704 6 วันที่ผ่านมา

    Sir please make a video on input and output chokes of VFD drives. And what is the purpose of using them.

  • @souravkarmakar1868
    @souravkarmakar1868 ปีที่แล้ว +1

    Siemens k VFD mai parameter kaise set kare.. Or fault ko clear kaise kare?? Or Reset kaise kare VFD ko or reset karne se kiya sab delete ho jayega program please detail mai ek video

  • @Maddyharyana3821
    @Maddyharyana3821 ปีที่แล้ว +1

    Sir v/f waha use krte hai..jaha humara variable torque hota hai..
    Or vector control waha use krte hai jaha hume constant tourque chaiye hota hai..
    Isiliye hum v/f ke case main energy saving kr pate hai..
    Vector main nhi..kyunki vector control frequency toh chnge hoti hai..par motor terminal par voltage torque ke according chnge hota hai..

  • @yahyarasheed6392
    @yahyarasheed6392 ปีที่แล้ว +1

    If we have problem of low input voltage due to which the motors are burnt, can we use the VFD, which allows the frequence to drop, keeping v/f constant and enabling the motor to produce a constant torque ?

  • @rajeshsteelplant4453
    @rajeshsteelplant4453 ปีที่แล้ว +2

    Sir drive में voltage बढ़ानेसे करंट बढ़ता हे...??

  • @ShadabKhan-ks4hf
    @ShadabKhan-ks4hf ปีที่แล้ว +1

    Sir vfd m hum motor rpm ko kam jyada karne k liye Frequency aur voltage dono vary karte hain
    Lekin jab motor 1500 rpm p run karti h toh frequency 50 hz aur voltage 6.6 kv hota h
    Fir 1800 rpm p run karte hain toh Frequency 60 hz hoti h lekin voltage 6.6 kv hi kyu rahta voltage kyu nhi badhta

  • @tekramsahu9050
    @tekramsahu9050 2 ปีที่แล้ว +2

    Sir DTC mode par video banaiye n

  • @Sanatan_dharamm108
    @Sanatan_dharamm108 2 ปีที่แล้ว +2

    Sir plz make a video on speed control of induction motor

  • @meetpitroda8413
    @meetpitroda8413 ปีที่แล้ว +1

    Motor overloads at 10hz frequency at full load and no load both. What is the issue ? Is there any solution for that. I know it should not be less than 15hz for normal induction motor but i need it to go that low sometimes.

  • @kshitijmohan4428
    @kshitijmohan4428 2 ปีที่แล้ว +3

    Hi Abhishek sir,I have one query why CT base relay taken ammeter feedback only from Y phase not from R & B -phase.Explain it with technical info .....

  • @prittamsingh6973
    @prittamsingh6973 2 ปีที่แล้ว +1

    Sir VFD me input current high output current low kyon hota hai at 50hz par bhi .is par video banao

    • @fazalurrehman7433
      @fazalurrehman7433 ปีที่แล้ว

      Input pe current low and output pe high hota hai

  • @anilsahooofficial8054
    @anilsahooofficial8054 2 ปีที่แล้ว +1

    Very informative 👌

  • @sunilsuman1250
    @sunilsuman1250 ปีที่แล้ว

    Very informative video sir thank you

  • @pradumndubey3951
    @pradumndubey3951 ปีที่แล้ว

    Thank

  • @apurbaroy3482
    @apurbaroy3482 5 หลายเดือนก่อน

    Sir, I have connect one motor with vfd but the motor operated with dol starter on off push button. Is it possible? If possible then please send the connection drawing. Waiting for your reply.

  • @smdcgaming558
    @smdcgaming558 ปีที่แล้ว +1

    Sir what is the formula for calculating the breaking capacity of breaker (vCB)

  • @ambarshrivastav3688
    @ambarshrivastav3688 2 ปีที่แล้ว +1

    Sir make telegram channel for cement industry requirement related

  • @ronitraj2825
    @ronitraj2825 2 ปีที่แล้ว

    Very helpful and to the point thank you sir

  • @sunandposhiya2220
    @sunandposhiya2220 2 ปีที่แล้ว +1

    Totel how many motor control mode please explain?? For example vector control mode, sensor less control mode .

  • @abhishekgound7479
    @abhishekgound7479 ปีที่แล้ว

    Sir vfd ki frequency change karne par moter ki efficiency par kya fark padta h

  • @wjames092
    @wjames092 ปีที่แล้ว

    with vfd we can control torque as well as speed then why do we use gearbox?

  • @mohibatharhashmi
    @mohibatharhashmi 2 ปีที่แล้ว +1

    Prv ke liye NO NC samjha dijiye sir

  • @ravindradeshmukh2112
    @ravindradeshmukh2112 ปีที่แล้ว

    Very good video sir

  • @bhagyaranjanmishra1846
    @bhagyaranjanmishra1846 2 ปีที่แล้ว

    Thanks for good knowledge boss

  • @manjujoshi6735
    @manjujoshi6735 2 ปีที่แล้ว

    Very informative

  • @rajendrapaliwal239
    @rajendrapaliwal239 ปีที่แล้ว

    Vector control k barre me bhi kuch bataiye sir

  • @PragatiSrivastava-ce5cg
    @PragatiSrivastava-ce5cg ปีที่แล้ว

    soft starter and auto transformer starter are same ?

  • @faizanpashamohammad4762
    @faizanpashamohammad4762 2 ปีที่แล้ว

    RMU connection and install process ke upar video kariye sir

  • @rushikeshgangawane4850
    @rushikeshgangawane4850 ปีที่แล้ว

    🙏🙏👍👍

  • @SUNILKUMARYADAV-vf5lj
    @SUNILKUMARYADAV-vf5lj 2 ปีที่แล้ว

    Sir VFD ko relay ke threw forward and reverse and inching and programming bataye pls

  • @ayushjptechnical5740
    @ayushjptechnical5740 10 หลายเดือนก่อน

    VVFD where used please make one video VVFD and VFD different

  • @arunjoshi2089
    @arunjoshi2089 2 ปีที่แล้ว

    Nice video 👍

  • @ravindradeshmukh2112
    @ravindradeshmukh2112 ปีที่แล้ว

    Sir please VFD vector and scler mode video

  • @tahirtabussam9918
    @tahirtabussam9918 ปีที่แล้ว

    Why we cannot use dimmer to change the voltages?

  • @shrinumukherjee5007
    @shrinumukherjee5007 2 ปีที่แล้ว

    Very nice

  • @networkingknowledge2184
    @networkingknowledge2184 2 ปีที่แล้ว

    Continue 👊

  • @udaypratap9187
    @udaypratap9187 2 ปีที่แล้ว

    Sir please upload alternator protection video.

  • @user-kc2hr3cs9v
    @user-kc2hr3cs9v ปีที่แล้ว

    To Keep torque constant,and vary speed.

  • @patelsanjay9735
    @patelsanjay9735 2 ปีที่แล้ว

    Vfd me F Kam karne se voltage Kam hota hai ya bathata hai

  • @paraggawade2568
    @paraggawade2568 2 ปีที่แล้ว

    Thanks sir

  • @kajalkoli5686
    @kajalkoli5686 2 ปีที่แล้ว +1

    Or sir current

  • @studywithap6474
    @studywithap6474 2 ปีที่แล้ว

    Are there disadvantages of low voltage applying to motor through vfd due to maintaining v/f ratio constant?

    • @bch2780
      @bch2780 ปีที่แล้ว

      The VFD have function IR compensate to boost voltage at low frequency

  • @soumyaranjannayak9078
    @soumyaranjannayak9078 2 ปีที่แล้ว

    Sir please make a video on full wave rectifier when input ac voltage is 220 and output voltage 320v and what's it's solution

  • @rahulprusty1369
    @rahulprusty1369 4 หลายเดือนก่อน

    Sir ek doubt tha agar, vfd me input bhi ac hai or output bhi ac hai phir usse dc me convert hi kyu kar rhe hai iska ek proper reason dije or vfd me aisa kya laga rehta hai jo uske frequency ko vary kar raha hai

    • @hemantverma5625
      @hemantverma5625 9 วันที่ผ่านมา

      Freqency ko kam jayada karne ke liye hi ac to DC phir (rectifier) phir DC to ac (igbt invertor circiut) kiya jaata hai igbt ke switching se frequency kam jaada hota hai vfd single phase input three phase out pu or three phase input three phase output dono model mai aataa hai jaada rating ki motor ke liye three phase input vaala vff use kiya jaata hai single phase ho ya three phase vo input hone ke baad DC hi banta hai phir DC to ac banta hai varieble frequency ke saath

    • @hemantverma5625
      @hemantverma5625 9 วันที่ผ่านมา

      Freqency ko kam jayada karne ke liye hi ac to DC phir (rectifier) phir DC to ac (igbt invertor circiut) kiya jaata hai igbt ke switching se frequency kam jaada hota hai vfd single phase input three phase out pu or three phase input three phase output dono model mai aataa hai jaada rating ki motor ke liye three phase input vaala vff use kiya jaata hai single phase ho ya three phase vo input hone ke baad DC hi banta hai phir DC to ac banta hai varieble frequency ke saath

  • @ravikumarvishwakarma2852
    @ravikumarvishwakarma2852 2 ปีที่แล้ว

    Pls specify with numerical example

  • @SurajsinhKarande
    @SurajsinhKarande ปีที่แล้ว

    Sir but VFD me ac to DC or DC to AC conversion q hota hai.... Or direct veriable transformer q nahi use karate speed control ke liye...

    • @hemantverma5625
      @hemantverma5625 ปีที่แล้ว

      Bhai tfr se frequency change nahi hota isliye invertor circuit use karte hai

  • @arifpathan7787
    @arifpathan7787 2 ปีที่แล้ว +1

    Sir types of electrical maintenance pe ek video banaa dijiye plz sir kaafi time se aapko request kar raha hu

  • @vaibhavidahotre8541
    @vaibhavidahotre8541 ปีที่แล้ว

    Why v by. F ratio is constant

  • @shyamshingadiya6586
    @shyamshingadiya6586 2 ปีที่แล้ว

    Sir can u explain whats happening if we increase frequency abov 50Hz in drive ??

    • @bch2780
      @bch2780 ปีที่แล้ว

      The flux of motor reduce proportional, So the torque of motor also reduce

  • @chandub523
    @chandub523 2 ปีที่แล้ว

    Sir in a soft starter v/f ratio is constant or not? Why

    • @bch2780
      @bch2780 ปีที่แล้ว

      Softstarter only reduce voltage at starting , frequency always 50Hz

  • @sankarmaity3659
    @sankarmaity3659 2 ปีที่แล้ว +2

    Sir how voltage to be varied to maintain constant V/F ratio.

    • @AjaySharmaIND
      @AjaySharmaIND 2 ปีที่แล้ว

      Using Potentiometer

    • @bch2780
      @bch2780 ปีที่แล้ว

      Vary PWM patterns