Panoorin nyo toh Bago kayo gumawa ng POSTE | Common Mistake.

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 ต.ค. 2024

ความคิดเห็น • 125

  • @julyemzconstructionidea
    @julyemzconstructionidea 2 ปีที่แล้ว +7

    Kung gusto mu matibay na foundation 16mm dapat Ang pinaka maliit na pwede mung gamitin sa 2storey

  • @tantan8825
    @tantan8825 2 ปีที่แล้ว +7

    Dagdag lang po sa 12mm na footing at 8mn na lateral ties rebar. Mababaw at masikip po yong hukay na 1meter para sa two storey

  • @michaelvillanueva658
    @michaelvillanueva658 2 ปีที่แล้ว +1

    Thank you for sharing your knowledge 👍👍👍

  • @ramercanlas525
    @ramercanlas525 2 ปีที่แล้ว +4

    2nd floor residence standard use of rebars are : 16mm -12mm- & 10mm...no need to used smaller bars.

    • @francisbriones6759
      @francisbriones6759 2 ปีที่แล้ว +1

      Relay on stractural plan not by your own standards.

  • @jakerubiales5946
    @jakerubiales5946 2 ปีที่แล้ว +1

    Pare, OK ang intension mo. Kaso Ang design ng foundation at structural components e dinedesign ng Authorize person. Civil engr or structural engr. Baka gayahin ito ng ibang tao. E di naman pare pareho ang design ng bawat bahay Or structure

  • @jamalodingmacalimpao3120
    @jamalodingmacalimpao3120 ปีที่แล้ว

    Nice content Bossing.

  • @valdovic5370
    @valdovic5370 4 หลายเดือนก่อน

    Depende sa laki ng bahay. Agree ako na medyo maliit 12mm sa malaki na 2 stories at mababaw. Pero kng 9 x 9 lang naman ka laki parang tamabayan lang ok na yan.

  • @michaelerwin8744
    @michaelerwin8744 2 ปีที่แล้ว +1

    Regarding rebars meron po talagang weldable type yung red painted tip.

  • @reynaldomangubat1070
    @reynaldomangubat1070 2 ปีที่แล้ว +2

    Undersize sir ang 8 mm na ties po ang tawag dyan. Sa beam apply yung stirrups

  • @marivetboysillotravel8223
    @marivetboysillotravel8223 2 ปีที่แล้ว +1

    watching lang dit my dear

  • @odragoreval6749
    @odragoreval6749 2 ปีที่แล้ว

    Boss mostly po ang mga rebars na nabibili po ngayon sa mga steel supplier ay weldable bars na po ,para if ever kailangan natin gamitan ng welding ay acceptable na at hindi kailangan mag suffer ang yield strength ng ating bakal po.

  • @cezexploresvlogs
    @cezexploresvlogs 2 ปีที่แล้ว

    Tama po yan....Nagppagawa din ako ng bahay wala foreman. Ako lang po ay isang simple n guro. Sinusunod ko ung nsa plano. Sa column nk dugtungan ay 1 meter ang pagitan n ang dulo ay nk offset ng ilang centimer para magka dugtong n maayos. If tuwid naman neede n ang overlap ay 1 meter. Kapag footing namn ay 1mx 1m or plus centimers ang tabon niya ay nsa 1 meter din sa footing n nag intersected ung column. Class A ung pinagamit ko 1:2:3. sa column, footing at beams at slab. Pero sa baba ay 1:2:4 sa flooring baba.Pagdating sa bakal 16mm gamit ko stirrup ko ay 12mm sana. Kaya lng umangal ang manggawa kz madyado n daw matigas. Kaya naging d 10 n lang. Pero kung papnsinin mo kung tibay ay matibay n sya. Prro masaigi p ding kapag 16mm strirrups ay 12 mm. kapag 12mm ang stirruod ay 1omm. Pagka horizontal 10mm. Never sa 0-9 mm. Thank u sa info...akala ko iverzied n gamit kong mga bakal.

  • @ydnarsniculacz7656
    @ydnarsniculacz7656 2 ปีที่แล้ว +4

    Sir engineer ka rin ho ba? Cguro kung hndi ho iwasan nyo magbigay ng advice about construction..........

    • @francisbriones6759
      @francisbriones6759 2 ปีที่แล้ว

      Base sa explaination hindi po approved sa structural plan.

  • @bitzbartz1515
    @bitzbartz1515 2 ปีที่แล้ว

    Lahat Pala Tayo engineer Dito.. thanks for sharing..

  • @johnmarksindol2868
    @johnmarksindol2868 2 ปีที่แล้ว

    Iba ang actual ky sa drawing.. Alam na yan kc cguro forman yan..

  • @godofredomacaraig9096
    @godofredomacaraig9096 2 ปีที่แล้ว +1

    I realy appreciate Napakaganda ng pagkadeliver ng topic brod... I salute ... Pero nagtaka lang ako bakit 8mm ang stirrup na itinuro mo.....

  • @relardztv605
    @relardztv605 2 ปีที่แล้ว

    Very nice job brad dahil sa vlog tutorial MO Maraming knowledge ang nakukuwa ko mula sa inyo about columns nasa mka punta kayo sa bahay ko at turuan mo ako paano

  • @eddierellores73
    @eddierellores73 2 ปีที่แล้ว +1

    kahit Hindi pantay Ang bakal Basta mahaba lng Ang pang dugtong.

    • @initing
      @initing  2 ปีที่แล้ว

      yes poh. tama kah

  • @ramirctinapan8249
    @ramirctinapan8249 2 ปีที่แล้ว +1

    Ok boss salamat magtatayo p naman ako ng 2 stories house

  • @paolopablo5292
    @paolopablo5292 2 ปีที่แล้ว +5

    Correction po , ayon sa ating Structural Code na batas, bawal po gumamit ng 12mm. rebars sa main component ng structure tulad ng footing, column, at biga. Dapat 16mm. yung minimum size na pwedeng gamitin kahit ito pa ay maliit ng bungalow house pa. Tapos yung sukat ng footing para sa 2 storey ay at least 1.2 x 1.2 x 0.40 meter minimum at yung depth at dapat 1.2 to 1.5 meters depende pa yan recommendation ng engineers. Tapos ugaliin maglagay muna ng graba na syang papatungan ng footing bago po ito ilagay. Dapat maglagay din ng porma sa gilid ng footing para hindi masira yung mixture ng ibubuhos ng konkreto.

    • @bisayakangdako3197
      @bisayakangdako3197 2 ปีที่แล้ว +1

      Nako masyado po kayong mahal😆😆😆😆😆😆😆😆😆 jowk.lang

    • @paolopablo5292
      @paolopablo5292 2 ปีที่แล้ว

      @@bisayakangdako3197 mas mahal po pag may naaksidente at mamatay dahil lng sa mahinang structure ng building kung ganun. Pwera pa yung babayaran mong danyos sa violation at penalty sa building official. =)

    • @reymondbajado8877
      @reymondbajado8877 ปีที่แล้ว

      @@bisayakangdako3197 tipirin niyo na lahat wag lang ung STRUCTURAL 👷🏗️

    • @Tusk-cg1zm
      @Tusk-cg1zm ปีที่แล้ว

      @@bisayakangdako3197 if mag papagawa po kayo ng bahay mas mabuti na pong gumastos kayo ng mas malaki for safety purposes pag dumating na yung mga unexpected calamities like earthquake

  • @wowideguzma1863
    @wowideguzma1863 2 ปีที่แล้ว +1

    Yung dowel sa chb dapat Ftb nalang kasi 2 storey bldg naman

  • @romeogilbertperalta8374
    @romeogilbertperalta8374 2 ปีที่แล้ว +1

    Simple at maliwanag na pagkaturo.
    Salamat po.

  • @rolandopineda8738
    @rolandopineda8738 2 ปีที่แล้ว +1

    boss..yung sakin lang kung gusto mung matibay ang bahay lagyan mu nang beam sa ilalim...sa akin lang kaso magatos cya....

    • @initing
      @initing  2 ปีที่แล้ว

      yes poh may tie beam yan.

  • @oliverumerez5531
    @oliverumerez5531 2 ปีที่แล้ว

    boss depende sa. klase ng lupa ang lalim ng hukay ng mga footing at poste

  • @obetmixtv1858
    @obetmixtv1858 2 ปีที่แล้ว +1

    Boss tanong lng po s ratio ng palitada... 1 is to 3 three nh.. Isa sako semento (25 kgs) by tatlo timba which is lagyan ng pintura (16kgs).. Tama po b ako sir....

    • @initing
      @initing  2 ปีที่แล้ว

      3 sako poh hnd timba

  • @nehpets2498
    @nehpets2498 2 ปีที่แล้ว +2

    Boss, kuha ko lahat ang explanation mo. Ang akin lang, kung meters or mm ang ginamit mo pg sukat, wag ka nang gumamit ng inch/inches. Na guguluhan yong mga bagohan, Buti kung engineers or architect ang nanood.✌️

    • @rafaelantonio8305
      @rafaelantonio8305 2 ปีที่แล้ว

      Dapat kasi meters and mm ang gmitin nalang, dahil ung inches is gmitnsa ibang bansa like america. Ang standard dito sa Pilipinas is M and MM

  • @kakubomaker2827
    @kakubomaker2827 2 ปีที่แล้ว +1

    Good too know t.y.👍👍👍👍

  • @obetmixtv1858
    @obetmixtv1858 2 ปีที่แล้ว +1

    Boss kung hndi n mn two storey ung ggawin...ano mainam ang sukat s footing...thanks boss...

    • @initing
      @initing  2 ปีที่แล้ว

      70-100cm poh

  • @rhodalynreyes3697
    @rhodalynreyes3697 2 ปีที่แล้ว

    Ok yan paliwanak mo pag mag taas kapa sa lebel ng 3mt pag 12mm ang materials ng post wag 8mm dapat 10 mm para kahit wag kana gumamit ng 16 mm sa birtical post

  • @yoyexka-angmaker5816
    @yoyexka-angmaker5816 2 ปีที่แล้ว +2

    Bakit inches gamit mo dapat cm or mm dahil ang nakalagay sa Plano skills mm madali e convert sa cm substandard gamit mo boss maliet ang 8mm Ang ginagamit 2nd floor 10mm ang anilyo 16mm ang culum bars

  • @junefallaria1075
    @junefallaria1075 2 ปีที่แล้ว +2

    IniTing ask q lng po, kayo ba ay civil engineer?

  • @goldendoubledragon5894
    @goldendoubledragon5894 2 ปีที่แล้ว +2

    antiohus kay diko kakita sa board heheheh

  • @allin3373
    @allin3373 2 ปีที่แล้ว +1

    Sino po dito ang gumagawa ng bahay papa renovate lang po yung 3rd floor at papa dagdagagn ng 4th Thanks sa sasagot

  • @wlalang4103
    @wlalang4103 2 ปีที่แล้ว

    Standard sa may pera😂

  • @reynaldomangubat1070
    @reynaldomangubat1070 2 ปีที่แล้ว +1

    Minimum po ay 16 mm. Vert. Bar...

  • @JenebebNamoc
    @JenebebNamoc 2 ปีที่แล้ว +1

    done JOIN. supporting ur channel

    • @initing
      @initing  2 ปีที่แล้ว

      maraming salamat sa supporta sir. god bless poh.

  • @d.master5634
    @d.master5634 2 ปีที่แล้ว

    now i know. salamat lodi.

    • @initing
      @initing  2 ปีที่แล้ว

      Welcome 😊

  • @Alnidtv
    @Alnidtv 2 ปีที่แล้ว +2

    Sir gusto ko magtanong, ung slab nang bahay ko umo uga uga pag may tao na maglakad lakad, ano dapat gawin para tumibay?

    • @initing
      @initing  2 ปีที่แล้ว

      try mong mag lagay ng i beam.

    • @Alnidtv
      @Alnidtv 2 ปีที่แล้ว

      If mag lagay nang i beam gagawa din ba nang poste?

  • @couplesforchrist3989
    @couplesforchrist3989 2 ปีที่แล้ว +5

    Hindi stirrups ties yan..basta sa concrete column, its a lateral ties, ang stirrups ties sa conc. beam lang yan..

    • @philippeandres7158
      @philippeandres7158 2 ปีที่แล้ว

      Tama un ung stirrups ay gingmit n term sa beam, mukhng ce ka sir kw lng nkatumbok ng tamang terms

    • @edenasay6618
      @edenasay6618 2 ปีที่แล้ว

      P

  • @buniknikvlog244
    @buniknikvlog244 2 ปีที่แล้ว +1

    Ok lang po ba kahit 9 mm at 10mm ang ginamit sa pagposte ng bahay? Ty.
    Tapos bukod pa po ba bakal pag me second floor?

    • @jomelmanalili7175
      @jomelmanalili7175 2 ปีที่แล้ว +1

      Pag wala second Floor ang bahay na papatayuan mo standard na bakal na gagamitin 12 mm to 10mm pag may second floor 16mm 20mm depende sa nag papagawa

    • @nelvintapulao340
      @nelvintapulao340 2 ปีที่แล้ว

      pag may second floor ka po at slab po delikado po. 16 mm dpt

  • @norliejanefabila3748
    @norliejanefabila3748 2 ปีที่แล้ว

    Sir meron paba remedyu Ang bahay pag di nilagyan Ng poste?..pinagdikit lng kase Ang hallow block pgkagawa

  • @alvinajoste8005
    @alvinajoste8005 2 ปีที่แล้ว

    Boss pag column ties ang tawag... Stirrups ang tawag pag beam.

  • @ronjamez4086
    @ronjamez4086 2 ปีที่แล้ว +1

    Bos sa sukat ng column at footing na sample mo sa 2 story pwedi ba yan kong roofdeck na 2 story?

    • @initing
      @initing  2 ปีที่แล้ว

      yes poh

  • @rferrer487
    @rferrer487 2 ปีที่แล้ว

    Threaded boss dapat un tali mahinayan

  • @lopezjaena6178
    @lopezjaena6178 2 ปีที่แล้ว +1

    Kung hind 2nd floor kailangan p rin ng footing?

    • @kuyaalex6826
      @kuyaalex6826 2 ปีที่แล้ว

      Kahit wall footing nlng pag bungalow

  • @JenebebNamoc
    @JenebebNamoc 2 ปีที่แล้ว +3

    dapat bah 16mm pag 2 story?

    • @initing
      @initing  2 ปีที่แล้ว

      12mm or 16mm poh

    • @rafaelantonio8305
      @rafaelantonio8305 2 ปีที่แล้ว

      16mm dapat boss, ang 12mm is for bungalow type. Sumunod tayo sa sinasabi sa nscp, wag base on experience lang. Maraming gingwa sa small construction na hnd nasusunod sa nscp.

  • @SNOWFEBROWN96
    @SNOWFEBROWN96 ปีที่แล้ว

    NAKULANGAN AKO SA PAGLAGAY NG CHB SA POSTE. KUNG HINDI HUHUKAYIN ANO ANG GAGAWIN? THANKS

  • @deliaballogan8048
    @deliaballogan8048 2 ปีที่แล้ว

    wala po sterrup ang poste si beam lng po ang may sterram lattaterel ties tawag jan.

  • @jozethuy9354
    @jozethuy9354 2 ปีที่แล้ว +1

    Boss may tanong ako 5"x5" sulat Ng pote bakal na ginamit 8mm 1floor matibay bah hun

    • @initing
      @initing  2 ปีที่แล้ว +1

      para sakin sir pag bahay ang pinag uusapan, hindi. ang 8mm pang stirrup lng yan. 10mm sana.

    • @rafaelantonio8305
      @rafaelantonio8305 2 ปีที่แล้ว

      Kapag bungalow boss gumamit ka na ng 12mm na rebars tska 10mm na anilyo. Tpos oag 2storey 16mm tska 10mm na anilyo

  • @jacintopawen4454
    @jacintopawen4454 2 ปีที่แล้ว +1

    Bos Parang mahina ata pag 2storey tas 12mm ang gamitin... 🤔

    • @initing
      @initing  2 ปีที่แล้ว

      16mm yan gamit ko boss

    • @sylviaatunayalojado3057
      @sylviaatunayalojado3057 2 ปีที่แล้ว

      Mahina talaga. Kpag second floor 2meters X 2meters ang hukay saka 16mm ang bakal

  • @kusinaqueen1874
    @kusinaqueen1874 2 ปีที่แล้ว +1

    tama poh kayu

  • @leovillafuerte1620
    @leovillafuerte1620 2 ปีที่แล้ว +1

    Anong sukat po sir ang layo ng joint or dugtong ng round bar?

    • @initing
      @initing  2 ปีที่แล้ว +1

      50cm poh

    • @leovillafuerte1620
      @leovillafuerte1620 2 ปีที่แล้ว

      @@initing slamat sir

    • @rafaelantonio8305
      @rafaelantonio8305 2 ปีที่แล้ว

      Mas safe, gmitin mo ung formula na 16d. Ung D is diameter ng rebars mo then multiply mo sa 16. Hnd kasi sa lahat ng size ng revars is 50cm ung idinidugtong. Ung sa 16mm kasi nasa 60cm na.

  • @rafaelantonio8305
    @rafaelantonio8305 2 ปีที่แล้ว +4

    As a civil engineering student, please sir wag ka magbigay ng gnyng details kung hnd ka engineer. Madami kang sinabi na halos hnd sasapak sa sinasabi sa NSCP. Hindi porke experience foreman or what so ever ka eh ok na yang mga sinasabi mo. May NSCP na pwedeng pagbasehan lalo na sa structural part ng bahay. Hindi basta basta dinidesign yan, it takes a long process pra magdecide sa sizes ng rebars, size ng columns and beams, depth ng footing at dami ng rebars.

    • @crisondesignandbuild2599
      @crisondesignandbuild2599 2 ปีที่แล้ว

      Tama ka sir .hndi rin ako engnr isa po akong foreman at small time contractor pero pero never pako nka encounter ng 1mtre na foundation and minimum rebars ko is 16mm minimum ng ties ko ahy 10mm..at ang structural design ahy nka depende Yan sa location kung malambot ba ang lupa sa Lugar mo h di pwde ang ganyang design ng structural..masmagandang I Consulta mo parin sa structural engineer pag dating sa ganyang,ang splicing ng main bar/vertical reinforcement bar ay L/3..or 33percent of height ng floor to another floor

    • @singianfamily1930
      @singianfamily1930 2 ปีที่แล้ว

      Yan ang problema sa mga ibang 4man, ang gusto nila mas marunong pa cla sa mga CE.

    • @petersmith5883
      @petersmith5883 2 ปีที่แล้ว

      Licensed nako marami na akong na encounter na gusto magpadagdag ng floors sa existing na bahay (2nd or 3rd floor up).
      Ang ending hindi na pwede kasi hindi na kaya ng footing/column ung idadagdag na floors.
      Sa panahon pa naman ngayon malalakas na ung bagyo. Malas mo pa kung malapit ka sa fault line.
      Kaya para sa peace of mind sa civil engineer kayo mag padesign.
      More or less makakatipid kayo since mas economical ung mga size ng column/beam/rebars.

    • @TotoPabilajr
      @TotoPabilajr 9 หลายเดือนก่อน

      Tama huwag mag advice Kong Hindi ka marunong baka gayahin nag iba

  • @saitamabaryonmode2533
    @saitamabaryonmode2533 2 ปีที่แล้ว +2

    Buti sayu standard nayan sayu eh samin 16 mm ginagamit tapos 10 mm

  • @Thefarmboy19
    @Thefarmboy19 2 ปีที่แล้ว +1

    sir tanong lng anong pwede size sa poste para ma flush ang #6 na chb salamat

    • @initing
      @initing  2 ปีที่แล้ว

      pwd poh

    • @Thefarmboy19
      @Thefarmboy19 2 ปีที่แล้ว

      @@initing anong dimension ng poste sir?
      salamat

    • @rafaelantonio8305
      @rafaelantonio8305 2 ปีที่แล้ว +1

      As per nscp, itinaas na nila ung minimum dimension sa 250x250 kapag bungalow then add k ng .5 kapag tataas ka ng storey. Kahit 6" chb mo sasapak yan jan bsta tama ung sukat nf column post mo

  • @joedelaluna8256
    @joedelaluna8256 2 ปีที่แล้ว +1

    Boss ang bhay ko ay sa pag ibig nkuha.duplex.ano po standard na poste Kong mg second floor.57 Sq.mter ang unit ko.fr.cavvite

  • @constructionfarming7449
    @constructionfarming7449 2 ปีที่แล้ว

    Boss kng my plano suminod kna lang sa pkano

  • @bzdk1010
    @bzdk1010 2 ปีที่แล้ว

    sir kng 1 storey lng at half concrete half amakan anu po suggestion nyu kalaki ang poste

    • @initing
      @initing  2 ปีที่แล้ว

      7x7 inches poh

  • @streetsmart89
    @streetsmart89 2 ปีที่แล้ว +1

    L/4 Yan boss engener Kaba or porman?

    • @initing
      @initing  2 ปีที่แล้ว

      yong L/4 para yan sa poste at bega.
      may video ako sa formula na yan.
      th-cam.com/video/1VbuK3NfJEI/w-d-xo.html

    • @Kahitanongchannel
      @Kahitanongchannel 2 ปีที่แล้ว

      @@initing Huwag kang magbigay ng instruction kung hindi ka license engr. bro. delikado yan ginagawa mo. Mag aral ka at kumuha ka muna ng license mo bago ka magbigay ng instruction tungkol sa bldgm construction. Sorry ha pero di mo karapatan ang magsabi ng ganyan. Mag consult muna kayo sa Engr. mismo. Huwag basta basta nagpapagawa ng bahay.

  • @Dynamity_hi
    @Dynamity_hi 2 ปีที่แล้ว

    hanap pcs man boss🤣🤣🤣

  • @jenebebnamoc8915
    @jenebebnamoc8915 2 ปีที่แล้ว +1

    2 story apat lng bah na 16mm sir?

    • @initing
      @initing  2 ปีที่แล้ว +1

      pwd 12mm poh dipindi sa design

    • @rafaelantonio8305
      @rafaelantonio8305 2 ปีที่แล้ว +1

      It should be 6 pcs and more boss, may formula yan na sinusunod para ma govern ng nscp. At wag 12mm gmitin mo, dapat 16mm.

  • @constructionfarming7449
    @constructionfarming7449 2 ปีที่แล้ว

    Boss engr. kba?

  • @joshuaildefonso227
    @joshuaildefonso227 2 ปีที่แล้ว

    Kami po 16mm at 10mm sir

  • @bontatanig4637
    @bontatanig4637 2 ปีที่แล้ว

    Mali ka sir!!!16mm ang gamitin mong bars para sa poste!10mm ang lateral ties!Magtie beam o flint beam ka rin!

  • @yousefteng1347
    @yousefteng1347 2 ปีที่แล้ว

    Hi po sir ask ko lang po ang location nyo plan ko po kasi mag send ng inquiries... salamat po

  • @rhandymujer3851
    @rhandymujer3851 2 ปีที่แล้ว

    Sir gaano karami yung 2 buhangin at 3 graba?

    • @initing
      @initing  2 ปีที่แล้ว

      yes poh

    • @rafaelantonio8305
      @rafaelantonio8305 2 ปีที่แล้ว

      Kapag may sako k ng semento dapat mapuno.mo un, un ung 2 buhangin same din sa graba. Or gawa ka ng kamaka na may sukat na 1x1x1m punuin mo un para tama ung proportion mo.

  • @ricardotogonon807
    @ricardotogonon807 2 ปีที่แล้ว

    Mahina ung bakal mo boss, dapat sa 2 storey 16mm 10mm para sa poste

  • @streetsmart89
    @streetsmart89 2 ปีที่แล้ว +1

    Sir paki sagot sa mga nagtatanong sa comment box mo

  • @joshuaildefonso227
    @joshuaildefonso227 2 ปีที่แล้ว

    Mahina po voice

  • @williamoseo3277
    @williamoseo3277 2 ปีที่แล้ว

    LANGYA naman contractor ka Pentel pen mo malabo, Hehehe

  • @alvingayoma4163
    @alvingayoma4163 2 ปีที่แล้ว

    Idol ask k lang paano naman pag binuhusan ang putting gaano dapat kakapal ang buhos ng isang poste

  • @elpidiocastillo3342
    @elpidiocastillo3342 2 ปีที่แล้ว

    Engineer ka ba?

  • @leandrobajacanjr.2172
    @leandrobajacanjr.2172 2 ปีที่แล้ว

    Ayusin mo ng kaunti drawin mo.

  • @norilyncavero308
    @norilyncavero308 2 ปีที่แล้ว

    hina boses mo, parang ako ang nahhirapan sa kakapakinig....

  • @rollyolpindo4891
    @rollyolpindo4891 2 ปีที่แล้ว

    Ang liliit naman ng sterup mo d bagay sa 16 mm na poste mo

  • @Kahitanongchannel
    @Kahitanongchannel 2 ปีที่แล้ว

    Ano ka ba? Sorry boss ha, Hindi ka pwedeng magbigay ng instruction about sa construction kung hindi ka Engr. Yon sinasabi mo lang ay siguro na experience mo. Walang pinagkaiba yan sa Doktor na license. Hindi ka pwde mag resita ng gamot kung hindi ka Doktor. Dapat may basihan ka kung bkt 16mm or 12mm ang bakal na ginagamit. ginagawan ng computations yan ng mga structural engr. May Soil investigations, load etc.

  • @Zionest-cc2gn
    @Zionest-cc2gn 3 หลายเดือนก่อน

    Wala no go Yung mga ginagamit mo na steel bars 2 storey 12mm Ang gagamit ka Ng 8mm nako Hindi Yan poydi sa akin, dapat matbay malalki Ang bakal na gamitin 20mm 16mm 12mm.

  • @patikchannel3558
    @patikchannel3558 2 ปีที่แล้ว +1

    salamat sir. gets ko nah