Experiment Parallel inverter non SYNC...what happen?...KABOMM Part 1

แชร์
ฝัง
  • เผยแพร่เมื่อ 21 ต.ค. 2024

ความคิดเห็น • 144

  • @onemytech196
    @onemytech196 3 ปีที่แล้ว +61

    Brother it was not an a stupid experiment it was a worth experiment for the electrical and electronic technicians and engineers.

  • @JR-kk6ce
    @JR-kk6ce ปีที่แล้ว +7

    No such thing as a stupid experiment in my view. Thanks buddy.

  • @belspace
    @belspace 3 ปีที่แล้ว +32

    Thanks for sharing. You have lost 2 inverters for us! Thanks man! Hopefully, subscription will compensate that!

  • @republicoftutorials6068
    @republicoftutorials6068 3 ปีที่แล้ว +13

    This is not stupid this experiment worth millions, you lost 2 inverter for us, Thank you for this & Please if you can make a tutorial about synchronization of two inverters

  • @omoleogedengbe3007
    @omoleogedengbe3007 3 ปีที่แล้ว +17

    Man your experiment is great to learn from! thanks guy.

  • @obiecanobie919
    @obiecanobie919 3 ปีที่แล้ว +6

    Try turning them on one by one first with a 100watt resistor in series on one of the wires , interesting experiment ,,a great sacrifice for scientific community watching it .

  • @emypena
    @emypena 2 หลายเดือนก่อน

    I know that it wil result in a disaster but no idea how grave. I give you a thumbs up for really showing connecting parallel inverter without syncronizing the sine wave.

  • @bien2t
    @bien2t 2 ปีที่แล้ว +6

    I've always wondered what would happen. 😅 good job. Just maybe next time set the switch/breaker a bit further from the inverters. Haha.

  • @josepeixoto3384
    @josepeixoto3384 2 ปีที่แล้ว +4

    Now please do a video where you do just like what you said: synchronize them;
    OPEN them up,modify them ,one master one slave, so that both outputs are in sync,then put the lamp BETWEEN them, in series,and if the lamp does NOT light (no current flowing),then hook them up; better with a dual trace oscilloscope...we'd love to see that.

  • @electrotsmishar
    @electrotsmishar 4 หลายเดือนก่อน +1

    thanks man!!! I had been searching for this for a long time

  • @wilfredomarino3413
    @wilfredomarino3413 ปีที่แล้ว +1

    Wow you share it very clear.hope yotube will pay your verry nice expirement brother

  • @jimmym2719
    @jimmym2719 2 ปีที่แล้ว +5

    Thank you bro..You are awesome, many of us will try if not for you. Very much appreciate your Experiment 👍

  • @bigmindmotivational1846
    @bigmindmotivational1846 5 หลายเดือนก่อน +1

    Thanks bro, I learned a lot as a technician

  • @vipinsaini7443
    @vipinsaini7443 3 ปีที่แล้ว +4

    It was a great experiment bro

  • @marvinbautista5663
    @marvinbautista5663 4 หลายเดือนก่อน +1

    thanks for your sacrifice bro.. worth it experiment

  • @lucasthijssen9844
    @lucasthijssen9844 ปีที่แล้ว

    LOL, that was what I expected to happen but never had the courage to do it myself! thanks bro

  • @davepetro5676
    @davepetro5676 ปีที่แล้ว +1

    I always wonder and I was to afraid to do it my self thank for video

  • @jasminpadernal2704
    @jasminpadernal2704 หลายเดือนก่อน

    I used to have a project of using two 3kva in parallel. Good thing i used to watch your vid first. What that sencronizer looks like? Please

  • @NIKELAKEINJECTIONSUBSTATION
    @NIKELAKEINJECTIONSUBSTATION 9 หลายเดือนก่อน

    Omor, it's not a stupid experiment. Thanks for this 👍👍

  • @JackSmith-wb7rr
    @JackSmith-wb7rr 2 ปีที่แล้ว

    Lol 😂 oh really you lucky caught on fire 🔥

  • @marklapez1649
    @marklapez1649 4 หลายเดือนก่อน

    Very good 👍🏼👍🏼👍🏼👍🏼 didn't need to experience that wow

  • @TechnoEveryday
    @TechnoEveryday 7 หลายเดือนก่อน +1

    What you can do is:
    Open both the inverters. Connect the DC side 300V capacitors of both the inverters in parallel and you're done

    • @cmnk8840
      @cmnk8840 5 หลายเดือนก่อน

      I don't think that would help. The issue is with making both inverters run with the same frequency and phase

    • @TechnoEveryday
      @TechnoEveryday 5 หลายเดือนก่อน

      @@cmnk8840 i am suggesting dc side (before the h-bridge where 370VDC are made). On dc side there's no frequency matching or synchronization issue

    • @cmnk8840
      @cmnk8840 5 หลายเดือนก่อน

      @@TechnoEveryday I understand your suggestion to parallel on the DC side. But that would not help because, after the DC side is the inverter stage on both inverters where both the inverters would run without synchronisation which is the main problem here.

    • @TechnoEveryday
      @TechnoEveryday 5 หลายเดือนก่อน

      @@cmnk8840 hmm i saw this somewhere on TH-cam

  • @Mr.J41M
    @Mr.J41M 3 ปีที่แล้ว +1

    Thanks to your Experiment...

  • @youandwhatarmy1
    @youandwhatarmy1 ปีที่แล้ว

    Thanks for taking it for the team, 😜

  • @peteroneill2991
    @peteroneill2991 2 ปีที่แล้ว +1

    Thank you saved me 2 inverters new subscriber.

  • @ahmetmutlu348
    @ahmetmutlu348 ปีที่แล้ว

    yeah booth inverters start working as referse inverters :P and that probably burnt tcoils and mofsets makes sense.
    so probably we need to disable one of the control signals and use only one of mofset drivers circuits instead ... ie copy /paralel connections from one mofsets gate plus and negative signals to other. so signals will be in sync. and probably even on alternate side polarities needs to be checked. as for mofsets its polarity switching circuit which means they are actually still dc on input and output. if you consider 50hz timings

  • @MegaCyrik
    @MegaCyrik ปีที่แล้ว

    Thank you. It was nice to see, now i will never forget.

  • @WinHlaing-zn1gc
    @WinHlaing-zn1gc ปีที่แล้ว

    Are you sure Phase and Neutral each inverter connection?I did not see using tester that phase or Neutral.

  • @smbuyaus
    @smbuyaus ปีที่แล้ว

    You saved me from killing my invertor. ✌👊

  • @sccofdrm274
    @sccofdrm274 2 ปีที่แล้ว

    Thanks for that experiment,
    Am so sorry for that damage

  • @samuelbellamy4218
    @samuelbellamy4218 2 ปีที่แล้ว

    Could you set them up like you would parallel a generator plug parallel cables plug and turn on one inverter and the turn on the second one. Woul that sync them? Not have them on before you connect them but after. When paralleling generators you don’t fire them both up and then connect them together

  • @Andrew-tw1pe
    @Andrew-tw1pe ปีที่แล้ว

    Hi there this is not a stupid video I see you've got about at 81 comments you've taught us what not to do,cuz I was about to do it with 2-ups thanks yor

  • @screen-protector
    @screen-protector ปีที่แล้ว

    I see red and black wires and wondering - are you ElectroBoom YT channel, or what? :D If you'd not reverse the polarity, maybe it would not blow ;). I'd say for sure would not blow.

  • @annel30626
    @annel30626 ปีที่แล้ว

    Nice experiment bro.unfortunately for two power inverter.this also can give me knowledge.thank you.

  • @napat327
    @napat327 2 ปีที่แล้ว

    I wonder for a long time. Thanks a lot for your sacrificing. Let’s see the solution.

  • @salmanahmed9464
    @salmanahmed9464 ปีที่แล้ว

    Great work at least we see the output

  • @TechnoEveryday
    @TechnoEveryday 7 หลายเดือนก่อน

    You successfully converted one inverter into a bird bell 🎉🎉🎉🎉

  • @MuhammadHanif-bx4pb
    @MuhammadHanif-bx4pb 3 ปีที่แล้ว +1

    tbh, I expect some explosion hehe. nice demo!

  • @agustinguzman6375
    @agustinguzman6375 3 ปีที่แล้ว

    yeah... this really didn't need that experiment.... but funny to see!

  • @Swenser
    @Swenser 4 ปีที่แล้ว +4

    OK. Now do synchronisation project thanks

  • @larryroyovitz7829
    @larryroyovitz7829 ปีที่แล้ว

    Budget Electroboom over here...

  • @kimhengkoy
    @kimhengkoy 2 ปีที่แล้ว +1

    Thank you for experimenting

  • @jualanled5563
    @jualanled5563 3 ปีที่แล้ว

    terima ksaih banyak Bang sudah mencoba ekperimen ini, dan manfaat untuk orang lain adalah agar jangan melakukan hal yg sama ..... dan akan fal akibatnya. trima kasih semoga sharenya banyak manfaatnya.

  • @kreampiemebowen7725
    @kreampiemebowen7725 9 หลายเดือนก่อน

    so how do you synchronize two inverters of same frequency and same voltage?

  • @brentjeffsonflorendo9664
    @brentjeffsonflorendo9664 5 หลายเดือนก่อน

    Thank you, this is very helpful.

  • @JB-po2mv
    @JB-po2mv 2 ปีที่แล้ว

    First of all thank you for the experiment .but wait a minute what about positive to one inverter and common shared to both inverters for your power into the inverters and then use your sync harness .do you think it's a possibility?can you share a sync video with us on how to master slave ???????

  • @alxp-zd1zj
    @alxp-zd1zj 4 หลายเดือนก่อน

    I bought a vevor inverter very expensive and should do 3kw peak 6kw. I used it alone not with another and used max 600w on it and after a month smoke came out and it was on fire. Would like to build my own or use a lot of cheap ones say 150w ones to make a string to make up the lot. Anyone has any ideas on how to do this without blowing it?

  • @MegaCyrik
    @MegaCyrik ปีที่แล้ว

    Can you try a gridtie to a offgrid inverter?

  • @gntech4464
    @gntech4464 4 ปีที่แล้ว +1

    Wait for your vedio

  • @markskise
    @markskise 2 ปีที่แล้ว

    Thanks Bro for good experiment.

  • @QUANGNguyen-kw3lf
    @QUANGNguyen-kw3lf ปีที่แล้ว

    You are genius bro 😂

  • @Rcrdo072
    @Rcrdo072 2 ปีที่แล้ว

    But we can parallel connect the 2 inverters to one source of battery to atleast distribute the loads to both inverters?

  • @anthonydequina2822
    @anthonydequina2822 3 หลายเดือนก่อน

    can you do a video about parallel offgrid and grid tie inverter?

  • @judeagamugoro4538
    @judeagamugoro4538 2 ปีที่แล้ว

    Thanks for the experiment

  • @anasasp
    @anasasp 5 หลายเดือนก่อน

    Good job

  • @jaymar921
    @jaymar921 9 หลายเดือนก่อน

    Thank you your the sacrifice

  • @TheBry_Guy
    @TheBry_Guy ปีที่แล้ว

    Would it make any difference if you powered one, then connect, then power the second? I am fairly sure they need to be "syncable", i.e. smart enough to look for and sync to a sine wave. Thats how you are supposed to sync portable inverter generators, but definitely no expert. It was fun to see the magic smoke though!

  • @letter2km
    @letter2km 4 ปีที่แล้ว +2

    You saved my life

  • @OnucheSimeon-ks4fb
    @OnucheSimeon-ks4fb ปีที่แล้ว

    Nice

  • @TheBeltcp
    @TheBeltcp 3 ปีที่แล้ว +6

    How to syncronize 2 inverter ?

    • @TechnoEveryday
      @TechnoEveryday 7 หลายเดือนก่อน

      Open both the inverters. Connect the DC side 300V capacitors of both the inverters in parallel and you're done

    • @realboy271
      @realboy271 5 หลายเดือนก่อน

      please make a video for detail

  • @mattlawton4715
    @mattlawton4715 3 ปีที่แล้ว

    @wajaeboseben AGS TECH
    Thoes inverters can be joined together but you have to do it from the inside👍

  • @apilutify
    @apilutify 3 ปีที่แล้ว +1

    How can we success among two inveerter synchronization

  • @saviourisrael182
    @saviourisrael182 6 วันที่ผ่านมา

    I love you brother 😂😂😂

  • @basketballjones6782
    @basketballjones6782 3 หลายเดือนก่อน

    Not only do you have dead inverters, but apparently you're missing the left and right hand sides of your video camera as well.

  • @kannanr9533
    @kannanr9533 3 ปีที่แล้ว

    Not stupid. We are all learning. Thanks.

    • @stevelamperta865
      @stevelamperta865 3 ปีที่แล้ว

      Actually it was stupid and waistful , You could have just read the manual ! The manual tells you weather they are capable of this or not ! They even say why there not able to do this ! So if he would have just read the manual or looked this information up online he could have learned the same thing without burning up the equipment ! WOW ! I am never shocked anymore .

  • @Tranquilitarian
    @Tranquilitarian 5 หลายเดือนก่อน

    I would expect to see this video on ElectroBoom channel.

  • @thebugs4934
    @thebugs4934 ปีที่แล้ว

    So what happened?Why did it blow?

  • @QUANGNguyen-kw3lf
    @QUANGNguyen-kw3lf ปีที่แล้ว

    U helped many others

  • @talagangsolar8658
    @talagangsolar8658 4 ปีที่แล้ว +1

    Good R&D

  • @brookssolarengineering9596
    @brookssolarengineering9596 2 ปีที่แล้ว

    Salute you tought mi some sence I wanted to try

  • @YUNGAYCHILE
    @YUNGAYCHILE ปีที่แล้ว

    They weren't in phase, obviously, so you got an overload.

  • @LloydLouieOGuia
    @LloydLouieOGuia 2 ปีที่แล้ว

    Thank you for this experiment i learn a lot.

  • @mustafanofal3265
    @mustafanofal3265 ปีที่แล้ว

    Thank you though; It is a good to know and sure it was not easy to lose two inverters !

  • @derrickdoherty066
    @derrickdoherty066 2 ปีที่แล้ว +1

    Thanks I learned a lot from it

  • @allinno168
    @allinno168 2 ปีที่แล้ว

    Good inspiration . For this experiment , conclusion is strong old will burn out the weaker one. either one will death. what if we make them in phase?

  • @vuaeco
    @vuaeco 2 ปีที่แล้ว

    Stupid? I don't think so. Learn by making mistakes is the smartest thing to do. This is how the smartest people on earth learn. Mark Zuckerberg, Elon Musk, Steve Jobs... they all learn this way. In fact, they even encourage their employees to make mistakes and learn from them. Here's Zuckerberg work ethics: "Move fast and break things"!

  • @bassemkhaled1957
    @bassemkhaled1957 2 ปีที่แล้ว

    😄😄😄😄

  • @whitehatdaily82
    @whitehatdaily82 ปีที่แล้ว

    I will do thumbs up for you

  • @marwinmuegamandac6750
    @marwinmuegamandac6750 3 ปีที่แล้ว

    The views did not even compensate the lost money. Time spend on illustrations could have more cost effective and safe. It's not an stupid experiment, but not very educational either because not all audience really understood what actually happened. Wish you best with content making bro

  • @hansdegroot652
    @hansdegroot652 ปีที่แล้ว

    Thx for this exanmple how not to do things. i have 2 cheap 150 watts and was wondering if one could ac in parrallel. I guess only if the wave forms are synced. Now i am sure never to try this 😀

  • @kamudankemter
    @kamudankemter ปีที่แล้ว

    Well thanks bro

  • @arshedali244
    @arshedali244 6 หลายเดือนก่อน

    At least you should check positive and neutral side of both

  • @phinex1228
    @phinex1228 2 ปีที่แล้ว

    God bless you !

  • @johnmarkseno6529
    @johnmarkseno6529 11 หลายเดือนก่อน

    thanls I learned a lot from it 🥰🥰

  • @wholysrogerkoala5248
    @wholysrogerkoala5248 6 หลายเดือนก่อน

    Il faut une diode anti retour ac comme pour les panneaux solaires qui est en DC mais paraît-il que cela n' existe pas pour le moment.

  • @aftabali-iv9ds
    @aftabali-iv9ds 7 หลายเดือนก่อน

    Thanks i am wondering what will happend😅

  • @raymondbrowning762
    @raymondbrowning762 2 ปีที่แล้ว

    many thanks, not stupid, breaking things is good

  • @eddietee6305
    @eddietee6305 ปีที่แล้ว

    The sine waveforms from each inverter has to be synchronized or very close to being synchronized.

    • @curve5746
      @curve5746 ปีที่แล้ว

      Obviously. That is a given

  • @ukaszsobaszkiewicz6510
    @ukaszsobaszkiewicz6510 2 ปีที่แล้ว

    Thank you!

  • @zobayerkibrianione4962
    @zobayerkibrianione4962 8 หลายเดือนก่อน

    😂

  • @tgsharp1158
    @tgsharp1158 ปีที่แล้ว

    worthy experiment!!! thank you!!!!

  • @cap_fearless8696
    @cap_fearless8696 3 ปีที่แล้ว

    🤣 that awesome

  • @teluknagajaya4607
    @teluknagajaya4607 3 ปีที่แล้ว

    Nice i try to in my inverter

  • @gntech4464
    @gntech4464 4 ปีที่แล้ว

    Great bro

  • @booterone1
    @booterone1 3 ปีที่แล้ว

    You let out all the smoke. When that happens the devices quit working.

  • @Abelladele
    @Abelladele 4 หลายเดือนก่อน

    Thank you so much 😢

  • @jimryan8865
    @jimryan8865 ปีที่แล้ว

    Very stink indeed. Thank you for showing this to us

  • @earthenergyhex
    @earthenergyhex ปีที่แล้ว

    wow, fried it!!!

  • @sulaimanakhleken9909
    @sulaimanakhleken9909 3 ปีที่แล้ว

    masak o inverter..mahal pulak tu🤣

  • @jec_ecart
    @jec_ecart 4 ปีที่แล้ว

    Enjoyed it