Seismic analysis | STAAD.Pro ||By- Akash Pandey||
ฝัง
- เผยแพร่เมื่อ 6 ก.ย. 2024
- #Akashpandey #STAAD.Pro #SeismicAnalysis
►Like the Facebook Page:- / unique.civil.5
►Telegram:- @Unique civil
►Instagram:- / unique_civil_akash
►Twitter:- / akaspandey
►Website:- www.uniquecivil...
Hello friends...
This channel is related to Civil Engineering Career Growth, Subjects & Various Engineering Streams.
Structural Engineer Interview Questions|| Part 1||
• Structural Engineer In...
What are the Structure Engineering Interview Topic || Part-2 ||
• What are the Structure...
Top 5 Interview Question related to AutoCAD By Akash Pandey
• Top 5 Interview Questi... \
Basic introduction class of AutoCAD in Hindi
• Basic introduction cla...
How to Become a Structure Design Engineer
• How to Become a Struct...
Which profile is Best for Civil Engineer ||Career Options||
• Which profile is Best ...
New Option for Site Engineer||Career option||
• New Option for Site En...
for more visit our website:
www.uniquecivil...
Thanks for watching || Please like subscribe & share || Also don't forget to press the Bell Icon ||
►My Camera stand-
AmazonBasics 60-Inch Lightweight Tripod with Bag-amzn.to/33NdrbN
►My Mobile Realme U1 (Ambitious Black, 3GB RAM, 64GB Storage)
link-amzn.to/2P5uYb3
►My Mobile Stand-
Marklif Gorilla Tripod/Mini Tripod 13 inch for Mobile Phone with Holder for Mobile, Flexible Gorilla Stand for DSLR & Action Cameras-amzn.to/2J8c0Nb
►My Favorite Book-
Phir Meri Yaad / फिर मेरी याद-amzn.to/31zasT0
If you have any question comment below
Please show the manual calculation for EQ resisting structures. Also if you can upload a video on the terms used and their definitions like Damping ratio, time period etc it will be very helpful.
If you have already uploaded these videos then kindly share me the link.
As stadd v8i is not compatible with latest IS 1893 -2016.
is we have to apply joint weight also?
bahut hi acha padhaya aapne sach me kafi dino se sir padha rahe the samjh hi nahi aa raha tha. great sir
sesmic analysis of g+25 building using staad pro with different soil type zone condition and its cost estimation project topic ☝️
Thank you so much for valuable information sir
Sir apki classes bohut ache se samajh me aati h
Share videos on Dynamic Analysis of multistory irregular and regular building by response spectrum method with all basic data and knowledge in staad pro
How did you get the value member weight 12,1 kN/m?
Good job 👍
Very informative
It's very helpful sir
Please make video on Analysis and design of RC building using RESPONSE SPECTRUM ANALYSIS
Please share video on seismic analysis of multistory irregular building by response spectrum method in staad pro
Sir when i select is code generate option is not showing.. kindly help
In general we prefer staad editor to define seismic load and we have to methods to seismic analysis... I,e joint load method and member load method..... Joint load method is more accurate but we need to make two files which is very time consuming process😭😭
Plz sir make a vedio on Canopy structure analysis.
Sir please sesmic analysis.of pier of box grider bridge
help me to model in staadpro a concrete column with a recessed end and the other free side ,, column dimension 0.35mx0.35 at 4m height ,,, with a vertical load of 3 ton ,,, to analyze it with earthquake is 1893-2002
Sir please make video on rcdc staad pro
Sir I need a video on deck design please sir
Why u did not apply load combinations
Seismic definition creation failed i have put value of zone also that failed
Bro,
Mujhe storey drift ka value nahi dikh raha hai result pe.
Please, help.
Damping ratio is 0.05 or 0.5. Because 5% value is 0.05
Sir kbhi irc sp 114 k according kr k dikha do
Sir when we assign Eq load,wind load,LL and DL should we follow any sequence
YES,EQ MUST APPLIED FIRST OTHERWISE STAAD GIVE ERROR
Sir IS 1894 part 1 2016 ismey apply kar sakta hey kya?
Slab ka estimate ka video share kare sir🙏
Brother slab ka estimation manual krna pdta h ya phir excel se krna pdta h aapko kisse sikhna h.
Sir 0.05 hoga damping aap galat le leya sir sayad 0.5
sesmic analysis of g+25 building using staad pro with different soil type zone condition and its cost estimation project topic ☝️