DB Inspections: Crabtree C50 👀
ฝัง
- เผยแพร่เมื่อ 8 ต.ค. 2024
- In this video, I go through the usual inspection plus a look at the infamous Crabtree C50 DB. This DB is regarded as one of the more dangerous DBs to work on due to the amount of exposed live parts and lack of barriers.
This video is aimed at learners and those new to the trade.
Work enquiries, please email: John@faultlesselectricalservices.co.uk
Website: www.faultlesse...
Instagram: www.instagram....
#electrical #electrician #eicr #testing #DB #consumerunit #fuseboard #crabtree #C50
Good video John. I enjoyed it and found it educational.
Quality ⚡⚡👊👊thanks John 👍
Well done John another great video 🤌
Great video and information. You certainly can't rush things on that board.
I Started in 1980 and never fitted one, my first CU had MK 3871's Love your videos - keep em coming!
I was 1982 and same as you never fitted one my guess for that board is 1977 / 1978
It’s a later C50 board. It’s a lighter gray than the earlier ones . Also the amperage on the mcbs are yellow . On the early ones it was white .
@andysims4906 nice one. Thanks for the extra info mate 👊
Nice one John! as a learner, I enjoy your videos and this is something I've not seen before... more exposed copper than the Wylex wooden framed boards 🤔 thank f*ck that isolator is there and you can work happily.
I can't understand why they are called the Widow maker with the safety features it has.😂. Nice vlog John, thanks
Great content!
Spot on John 👌
Great vids these, learn a lot. Thanks
Perfect video
I know the fact
You know more the. Jordan
For sure
❤ he is more on bussiness marketing
But you know really good
Can you make video explaining 3 phase System pls
Thank you ❤
Will you be recommending that it's upgraded....I'll presume so, but interested to know how the report ended up.
@slservices6463 Yes there's was sockets that could be used externally with no rcd and a bathroom with no supplementary bonding so deffo recommend an upgrade 👍
Still got that DB in my house
Know of a house with a C50 CU..... Run & don't answer the calls!!! 💥
Dangerous... Pah it's only a single phase board.😅 At work we have loads of 3 phase C50's so gloves on anytime I have to open one up live! Also there isn't even an earth bar as you were supposed to put a lug and nut/bolt on the case, that is if there is a CPC as often they just used the conduit/trunking 😮
Did you go to the ESK curry night John
@@Dog-whisperer7494 I certainly did mate
A good video however the breakers are bakelite thus are ACMs and against the law to sell on. Many of these I have come across have been made safer by asbestos sheets placed over the exposed live parts. Who knew when it was done asbestos wasn't that safe.
John How are you? Enoch from Ghana 😂
@enochabban8086 I'm very well thank you mate 👊
👍🙏
vsauce secret assistant?
@@idoesstuff Have you ever seen me and Vsauce in the same room? #justsaying 😂
This needs to be changed