Fault finding on kitchen ring, wall chasing and capping, Exotic life of an electrician

แชร์
ฝัง
  • เผยแพร่เมื่อ 29 ก.ย. 2024
  • Sorting out dodgy Dave’s diy install on old kitchen ring,
    bit of wall chasing and capping,
    More video of hands on tools,
    armeg chisel bit i was using: amzn.to/2Pnl1pi
    let me know in the comments if you prefer longer 25-35 min videos or smaller but more often,
    My Instagram: / n_bundy_electrical
    This video is for entertainment purposes only and is in no way intended as a guide or 'how to'.
    If you would like to support me further I now have a Patreon page. If you would like to become patron please follow the link below. This will enable to me to create much more content for you, thank you!
    / nickbundyelectrical

ความคิดเห็น • 265

  • @JBE
    @JBE 5 ปีที่แล้ว +29

    It's never straight forward is it mate. Testing is everything in our game and I'm glad to see a professional approach towards dealing with that shitty wiring. Nice vid as always.

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว +2

      J Beck Electrical cheers dude 😘

    • @catsbyondrepair
      @catsbyondrepair 5 ปีที่แล้ว +2

      British wiring is dogshit

    • @uplightuk8924
      @uplightuk8924 4 ปีที่แล้ว

      YUKI JINJUJI At least we wire our sockets in a ring and it a radial

    • @kevinpickett7249
      @kevinpickett7249 2 ปีที่แล้ว

      @@uplightuk8924 90% of Uk homes have a ring main in them ( the radial is fine when correctly used though )

  • @paulkinsley730
    @paulkinsley730 5 ปีที่แล้ว +2

    Another quality video nick, full of content and useful information , a great help for those who are new to the industry like myself,keep up the good work.

  • @Chris_In_Texas
    @Chris_In_Texas 4 ปีที่แล้ว

    For god sake, what a mess you guys have to deal with. Someone needs a 6 pack or pints. All these buried junction boxes and stupid rings. I am so glad we don't have rings in the US. In theory no hidden junction boxes are allowed as well in the US although the do happen from time to time. Also so lucky for wooden wall construction, so much simpler than having to deal with the brick and cutting out races. Hats off to you guys.

  • @jondonnelly3
    @jondonnelly3 4 ปีที่แล้ว

    Good advert for the end of ring circuits. Fine when first put in but over time it turns into a mess then whole thing needs redone. Just run 4mm radical for kitchen sockets instead and put appliances on there own circuits.

  • @ashmanelectricalservices4318
    @ashmanelectricalservices4318 5 ปีที่แล้ว +2

    The wiring in that kitchen was a complete mess, glad you managed to sort it.

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว +1

      Alvin Ashman one of those jobs where I’m glad I had my camera, and it all came together eventually, I was just concerned I had Adam with me so late 😂

    • @ashmanelectricalservices4318
      @ashmanelectricalservices4318 5 ปีที่แล้ว +2

      @@NBundyElectrical Yes, you had him out way pass his bedtime 😂😂😂

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว

      😂😂😂

  • @joebristowtechnologicalbre2073
    @joebristowtechnologicalbre2073 5 ปีที่แล้ว +6

    In most cases for a new kitchen, I just allow to rewire the kitchen. You never know what you’re gonna find and you need that 32amp ring in a kitchen more than any other room in the house. By the time you’ve found the issues, you may as well just start again.

  • @smartchip
    @smartchip 4 ปีที่แล้ว

    Dodgy, it's usually a case in call outs, be it systems, electrical work or breakdowns on machines, being a detective and workout what someone else has done, being in industry and academia is rare, as its well audited and has a paper trail, imagine a multi million pound /dollar system with this level of cowboy electrician and Engineer work,

  • @calebtownson8888
    @calebtownson8888 3 ปีที่แล้ว +7

    So crazy the work you guys have to go through to run wiring and chase everything. Makes me feel like I have it easy fishing drywall/stick frame here in Canada

  • @deanholloway7755
    @deanholloway7755 3 ปีที่แล้ว

    At what stage do you think sod it I'm starting from scratch 😊

  • @unapologeticapologist5167
    @unapologeticapologist5167 5 ปีที่แล้ว +6

    This is so strange compared to how we do things in the US

  • @jeremykemp3782
    @jeremykemp3782 3 ปีที่แล้ว

    from here to there then over to, wait no, there, no here to there, here no , actually yes , to there and yes that's it : )

  • @snail5967
    @snail5967 5 ปีที่แล้ว

    Nick - quick question for a novice spark but how do you secure your capping - do you use raw plug or a particular type of screw like wall dogs? Great videos by the way - very real - I am dealing with the same problem in a kitchen ring that is reading open circuit in the line cables - just got to convince the client that I need to cut holes in her ceiling to check all the junction boxes I found hidden in the void!!

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว +2

      Hey snail, if it’s soft walls I just impact a screw straight in but harder walls I red plug and screw, yeah best to go digging abit 👌

  • @dharmeshmepani7800
    @dharmeshmepani7800 4 ปีที่แล้ว

    Hi what long nose pliers are you using in video look handy

  • @andyr4735
    @andyr4735 3 ปีที่แล้ว

    Im 34 and an office worker but looking at getting into the trade. My biggest fear is not being able to get to terms with the testing side of things. Earth to neutral ect can anyone explain it in layman's terms

  • @pepsinotmax
    @pepsinotmax 5 ปีที่แล้ว +1

    If there wylex nsb MCBs then potentially the 6A, 16A and 10A breakers need replacing as they have been recalled

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว +1

      Mitch Waite I’ll double check when I’m back Monday 👌 cheers for heads up

    • @pepsinotmax
      @pepsinotmax 5 ปีที่แล้ว +1

      Heres a link to the information, may not need it but defo worth a check. www.google.com/url?sa=t&source=web&rct=j&url=www.electricalsafetyfirst.org.uk/product-recalls/2010/10/electrium-miniature-circuit-breakers-mcbs/&ved=2ahUKEwjVwtebs4PkAhVpQEEAHW1RBK4QFjABegQIAxAB&usg=AOvVaw028_-WOJI9etKOpJEHgFx0

    • @richardwilliamson3624
      @richardwilliamson3624 5 ปีที่แล้ว +1

      Not all were recalled. You need to check the serial numbers.

  • @DerekHundik
    @DerekHundik 4 ปีที่แล้ว

    6:15 what are pliers ?

  • @jameswilliams7974
    @jameswilliams7974 5 ปีที่แล้ว

    Did you run 2 sockets of that spur? I thought it's only 1 allowed?

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว +1

      No just the one 👍

    • @jameswilliams7974
      @jameswilliams7974 5 ปีที่แล้ว

      @@NBundyElectrical cheers. How long had you been a spark before you set up on your own?

  • @alexdougherty4905
    @alexdougherty4905 5 ปีที่แล้ว +2

    Grab my strong hand 🤣🤣🤣🤣

    • @AndyK.1
      @AndyK.1 5 ปีที่แล้ว +1

      Alex Dougherty he had a fractured wrist a few months ago. Sound like it’s not healed. Poor self employed guy.

  • @chimairaxpsycho
    @chimairaxpsycho 4 ปีที่แล้ว

    at 6:16 what pliers are those?

  • @niceguy235uk1
    @niceguy235uk1 5 ปีที่แล้ว

    I'm not entirely sure about walking around with that t-shirt on.
    Anyhoo, when we are asked to price a kitchen refurb, we are way too busy.

  • @DaC-lt5mk
    @DaC-lt5mk 5 ปีที่แล้ว

    You said ring main so many times lol, it's a ring final my lad😂

    • @SparksDan
      @SparksDan 5 ปีที่แล้ว +1

      Never met a spark who says ring final 😂😂 doesn't roll off the tongue

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว +1

      Ring final it is from now on 👍

    • @DaC-lt5mk
      @DaC-lt5mk 5 ปีที่แล้ว

      @@NBundyElectrical hahaha don't change for me mate, great video as always xoxox

    • @uplightuk8924
      @uplightuk8924 4 ปีที่แล้ว

      I say ring main

  • @MagnetechSolidSolutions
    @MagnetechSolidSolutions 5 ปีที่แล้ว +1

    At this point we would just start to rewire the circuit..... (Magnetech Solid Solutions Ltd)

  • @acelectricalsecurity
    @acelectricalsecurity 5 ปีที่แล้ว +17

    A prime example why only electricians should do electrical work in the kitchen, there is no way a kitchen fitted would have found that, another job where you had no favours, leaving the kitchen in 🙄

    • @ashmanelectricalservices4318
      @ashmanelectricalservices4318 5 ปีที่แล้ว +3

      Agreed, such a pain trying to work round fitted units and appliances.

    • @motorone5301
      @motorone5301 4 ปีที่แล้ว

      I always get a plan of the kitchen drawn with dimensions. Much easier to set out as discuss with clients. I will even autocad all my own drawings and do proper dimensioned drawings. Then draw up electrical layout on that

  • @skamuk1
    @skamuk1 5 ปีที่แล้ว +3

    Typical shit wiring in a kitchen, I think 90% of kitchens we work on are in that state before we start. We tend to not bother trying to salvage anything and run it all in new where possible. Am in the habit of running 2 radials for a kitchen, with grid switches for appliances.
    I find it easier to run switched feeds to the top of the wall units for under cabinet lights and either somehow leave a draw wire for the ELV stuff or if your organised enough get the under cabinet lights on site for the first fix stage and run them in so the transformer or driver ends up on top of the cabinet rather than on the underside. Looks neater and is easier to work on in the future. We normally fit LED tape so we’d first fix the ELV cable that goes between the driver and the tape.

  • @artisanelectrics
    @artisanelectrics 5 ปีที่แล้ว +3

    What are those pliers you’re using?

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว +1

      Artisan Electrics www.amazon.co.uk/Telephone-pliers-Wiha-Insulation-approved/dp/B00ISP7L7E/ref=pd_aw_sim_60_1/262-3724520-8920540?_encoding=UTF8&pd_rd_i=B00ISP7L7E&pd_rd_r=a02335f5-af0d-4a58-980a-4c9f49638be3&pd_rd_w=Xwv1Q&pd_rd_wg=Qyjhe&pf_rd_p=4f3e997e-5715-4eb0-b5ff-04ed185317f1&pf_rd_r=HQCB7YBZYZBV577R15ZG&psc=1&refRID=HQCB7YBZYZBV577R15ZG really useful bud

    • @alexdougherty4905
      @alexdougherty4905 5 ปีที่แล้ว +1

      I like them!

    • @muzikman2008
      @muzikman2008 5 ปีที่แล้ว +2

      I noticed them lol..I have some VDE rated Draper Ergo ones angled like that but not with the shielded bit on the handle.

  • @keitho77
    @keitho77 5 ปีที่แล้ว +5

    Was that a multi tool you used for cutting outside lines for chases? What bit did you use?
    Grab my strong hand child! : )

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว +9

      keitho77 just normal wood bit that’s fucked so I angle grind big teeth in it to cut plaster bit easier and keeps costs down, 🖐🖐🖐🖐

    • @scratchblack
      @scratchblack 5 ปีที่แล้ว

      @@NBundyElectrical nice tip mate

  • @alanallington1001
    @alanallington1001 4 ปีที่แล้ว +1

    Radial for a kitchen? Dish washer 13a kettle 13amp

  • @artisanelectrics
    @artisanelectrics 5 ปีที่แล้ว +2

    Everyone loves a bit of fault finding!

  • @GiffordsElectrical
    @GiffordsElectrical 5 ปีที่แล้ว +2

    Great video tonight nick. Entertaining and informative. Nice to see a bit of fault finding. Shocked to see junctions in the wall like that. Just goes to show you never know what you’re gonna find at a job.

  • @bramcoteelectrical1088
    @bramcoteelectrical1088 4 ปีที่แล้ว +1

    4mm kitchen radicals nice and easy to add additional and changes I switch from 2.5mm rings in kitchens.
    Defo ripp that out lol not in prescribed zones🤣😎😉

  • @johnibbertson2960
    @johnibbertson2960 2 ปีที่แล้ว

    nick knowing you were going to all that trouble of re chasing your ring why bother finding that fault just renew ring? and rip cables out like you did yeh.

  • @itsallgravy_9437
    @itsallgravy_9437 5 ปีที่แล้ว +2

    Good video, nicely walked through and good explanation of your thinking. Cheers NB!

  • @ladcjd1
    @ladcjd1 5 ปีที่แล้ว +2

    Like horizontal wiring very safe not.

  • @supersparks9466
    @supersparks9466 5 ปีที่แล้ว +12

    I don’t entertain any existing wiring any more (for the most part) unless it’s looks like I done it. I always Install new as a default.

  • @DerekHundik
    @DerekHundik 5 ปีที่แล้ว +1

    better use 80 mm holesaw to cut the holes or go by the size of your palm . easy to patch it after

  • @UnkyjoesPlayhouse
    @UnkyjoesPlayhouse 4 ปีที่แล้ว

    in the US there is no way they allow hidden junction boxes in the wall without an access panel, nor are you allowed to run wires behind a piece of plastic covered with plaster... those would have to be run between studs or covered in metal conduit, and run outside of the wall, the UK plugs are great and I wish we had them here in the US.

  • @DerekHundik
    @DerekHundik 5 ปีที่แล้ว +2

    16:09 what's the tool whats the blade

  • @stevecraft00
    @stevecraft00 5 ปีที่แล้ว +2

    Cant wait to get stuck into stuff like this on my apprenticeship.

  • @supersparks7770
    @supersparks7770 5 ปีที่แล้ว +1

    I know it’s not your doing nick but according to the subtitles your putting in a ‘six mile feed’ 😂 just made me chuckle 😂😂😂

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว +3

      😂😂 voltage drop will bit a fair bit on that one 👀

  • @mattmedlicott8125
    @mattmedlicott8125 5 ปีที่แล้ว +2

    Great video again! Doesn’t look good for the rest of the house if the kitchen is like that 😂

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว

      I know right 😂 hope to god they don’t ask for a new CU

    • @simongreenidge6454
      @simongreenidge6454 5 ปีที่แล้ว

      Kitchen fitters can do horrible things to a previously well installed kitchen circuit.

  • @bramcoteelectrical1088
    @bramcoteelectrical1088 4 ปีที่แล้ว

    allow 900mm worktop height plus 150mm to the bottom of the box, based on if they have granite or other upstand you will clear it, a 150mm tile fits neatly underneath, it is one and a half 100mm tiles so you don't get a messy bit underneath or above the box, if they have tiles the size of paving slabs it goes in the middle of the tile anyway!

  • @tresslerj1985
    @tresslerj1985 5 ปีที่แล้ว +3

    Good job. It's a ring final though.

    • @supersparks9466
      @supersparks9466 5 ปีที่แล้ว +3

      Oh behave

    • @westinthewest
      @westinthewest 5 ปีที่แล้ว +2

      Not as bad as a label for 'Main Ring Main' I saw recently.

  • @jamievaughan6431
    @jamievaughan6431 5 ปีที่แล้ว +1

    Good vid Nick..👍🏻 9.5k views only 4k subs. 🤔

  • @AndyK.1
    @AndyK.1 5 ปีที่แล้ว +1

    I do wish you would give kitchens a
    Ring or 4mm 32A radial. With only 20A that is only 2 heavy appliances that can be on together.

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว +1

      Andy Kirwan the only heavy appliances that would be on would be micro wave and kettle as washer and dryer are in utility and cooker has its own 6 mm but I get your point 👍

    • @AndyK.1
      @AndyK.1 5 ปีที่แล้ว +1

      N Bundy Electrical ok. Also consider dishwasher, toaster coffee thing,

  • @jonshouse1
    @jonshouse1 4 ปีที่แล้ว

    Disclaimer I am not an electrician, but I notice the wiring seems to have a lot of vertical runs (pain for fitting cupboards), why not bring those down in the corners as well. Also wiring seems to change direction from horizontal to vertical without entering a backing box at some points, does that meet regs? I am never quite sure....

  • @pinchermartyn3959
    @pinchermartyn3959 ปีที่แล้ว

    Very good. Thanks.

  • @ste5210
    @ste5210 5 ปีที่แล้ว +1

    Hi nice video ... what were them long nosed pliers you were using at the start of the video?

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว +1

      Cheers bud and here you go
      www.amazon.co.uk/Telephone-pliers-Wiha-Insulation-approved/dp/B00ISP7L7E/ref=pd_aw_sim_60_1/262-3724520-8920540?_encoding=UTF8&pd_rd_i=B00ISP7L7E&pd_rd_r=a02335f5-af0d-4a58-980a-4c9f49638be3&pd_rd_w=Xwv1Q&pd_rd_wg=Qyjhe&pf_rd_p=4f3e997e-5715-4eb0-b5ff-04ed185317f1&pf_rd_r=HQCB7YBZYZBV577R15ZG&psc=1&refRID=HQCB7YBZYZBV577R15ZG

  • @asamitchell7948
    @asamitchell7948 5 ปีที่แล้ว +1

    Only place I dont use a radial is a kitchen too many loads for a 16 even a 20 amp circuit.
    Ring always for a kitchen then radials everywhere else.

    • @clickwithjonesy
      @clickwithjonesy 5 ปีที่แล้ว

      worked in australia for 6 years doing new builds. Never had a problem with overloading a 16a breaker on a radial for a kitchen.

    • @ashmanelectricalservices4318
      @ashmanelectricalservices4318 5 ปีที่แล้ว

      4mm 32A radial???

    • @westinthewest
      @westinthewest 5 ปีที่แล้ว +1

      I rarely find that 32A rings are necessary. Most kitchens are fine with 20A, especially if there's a separate circuit for the utility room. I left a datalogger running for two weeks at a recent kitchen installation and it only occasionally went slightly over 20A for a couple of minutes. If you do a load assessment of your own kitchen and apply diversity you'll probably get a similar result confirming that 20A is fine. Good design requires that you assess loads for each installation and consider all the available options rather than having a rule that you stick to regardless.

    • @abbottfamily6317
      @abbottfamily6317 5 ปีที่แล้ว

      @@ashmanelectricalservices4318 Yes!

  • @garylatto4191
    @garylatto4191 5 ปีที่แล้ว +2

    Yeah what are those please mate ?

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว +1

      Gary Latto www.amazon.co.uk/Telephone-pliers-Wiha-Insulation-approved/dp/B00ISP7L7E/ref=pd_aw_sim_60_1/262-3724520-8920540?_encoding=UTF8&pd_rd_i=B00ISP7L7E&pd_rd_r=a02335f5-af0d-4a58-980a-4c9f49638be3&pd_rd_w=Xwv1Q&pd_rd_wg=Qyjhe&pf_rd_p=4f3e997e-5715-4eb0-b5ff-04ed185317f1&pf_rd_r=HQCB7YBZYZBV577R15ZG&psc=1&refRID=HQCB7YBZYZBV577R15ZG
      Great bit of kit bud 👍

  • @Dal_Chris
    @Dal_Chris 5 ปีที่แล้ว +1

    Just a quick one regarding switches I was told on the grapevine newer installations require or a good to have naturals at the switches as future proof for dimmers ect. Is this true? (From an older industrial focused electrical apprentice)

    • @willr937
      @willr937 5 ปีที่แล้ว

      You don't need a neutral for switching purposes , including dimmers

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว +2

      It’s becoming a newer thing to do, helps with smart switches

    • @Dal_Chris
      @Dal_Chris 5 ปีที่แล้ว +1

      Thanks both, good videos nick thanks for the content mate.

    • @ashmanelectricalservices4318
      @ashmanelectricalservices4318 5 ปีที่แล้ว

      It's good practice, I can't see it becoming a requirement though.

  • @iankerr4380
    @iankerr4380 3 ปีที่แล้ว

    Hi Nick, sorry to be picky with your work, but I would never use the wall corner join in a kitchen, as a future precaution, as most kitchen fitter would be drilling/fixture fitting in corner for cabinets, better using ceiling/wall zone then drop down to accessories

  • @ofrimashiah2
    @ofrimashiah2 5 ปีที่แล้ว

    Hi mate 😀i have a quick question
    i can buy 650 w 850 w and 1050 w angle grinders. I will need one for some tiling around the house. And also i wanna do some chasings. What model should i buy? The 650 i believe is too weak. The 850 is good for tiling. But is that enough for chasings? Or it will burn down? And also can i do chasings with a rotary hammer? Or i should just get a 50 usd grinder?

  • @nicnic578
    @nicnic578 4 ปีที่แล้ว

    Shower of shite. Seems you know what your doing but as a plasterer, I was crying at the way your smashed your way through this one 👀👀

  • @fut_tczc8589
    @fut_tczc8589 ปีที่แล้ว

    Look at adam😂😂😂

  • @johnschlesinger2009
    @johnschlesinger2009 5 ปีที่แล้ว +4

    I would have put in a separate radial for the dishwasher, to give more generous capacity, or alternatively, installed one 32A radial, in 4mm sq. t&e.

  • @nathanmemmory4981
    @nathanmemmory4981 5 ปีที่แล้ว +1

    What is the tester you are using great videos keep them up. Whats the hager gang thanks

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว

      cheers nath, and megger met 1552, and its when you post a picture on instgram of a hager fuse board you have fitted and they send you a t-shirt

    • @nathanmemmory4981
      @nathanmemmory4981 5 ปีที่แล้ว

      Why not sign up to the hager insight team if you fit hager

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว

      Never heard of it what’s it for?

  • @rowles13
    @rowles13 5 ปีที่แล้ว +1

    Rip it all out and rewire

  • @davidyounie7802
    @davidyounie7802 5 ปีที่แล้ว +1

    Your videos are great pal, keep them coming 👍

  • @zjzozn
    @zjzozn 5 ปีที่แล้ว +1

    Why don’t you install 10mm2 for cooker circuit?

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว +2

      zjzozn unesserary for the size of cooker they are having

    • @zjzozn
      @zjzozn 5 ปีที่แล้ว

      N Bundy Electrical Ok gas hob I see 👍

  • @simonradford3863
    @simonradford3863 5 ปีที่แล้ว +1

    Hi nick can I ask you where you got those plyers in this video thank you

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว +3

      My local whole saler, go you want me to find you an amazon link?

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว +4

      www.amazon.co.uk/Telephone-pliers-Wiha-Insulation-approved/dp/B00ISP7L7E/ref=pd_aw_sim_60_1/262-3724520-8920540?_encoding=UTF8&pd_rd_i=B00ISP7L7E&pd_rd_r=a02335f5-af0d-4a58-980a-4c9f49638be3&pd_rd_w=Xwv1Q&pd_rd_wg=Qyjhe&pf_rd_p=4f3e997e-5715-4eb0-b5ff-04ed185317f1&pf_rd_r=HQCB7YBZYZBV577R15ZG&psc=1&refRID=HQCB7YBZYZBV577R15ZG

  • @sparksparky9592
    @sparksparky9592 5 ปีที่แล้ว +1

    Another good video, you made the chasing look easy, what sds bit were you using?.

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว +1

      Spark Sparky cheers mate it’s the armeg angled wall chase bit, it’s a dream ❤️

    • @sparksparky9592
      @sparksparky9592 5 ปีที่แล้ว +1

      Thanks Nick

    • @peterthomas9440
      @peterthomas9440 4 ปีที่แล้ว

      Good old fashioned lump hammer and bolster still does the job. Still can’t fit forearms into shirts though...

  • @chazvirdee2012
    @chazvirdee2012 5 ปีที่แล้ว +1

    Great video. What tool did you use to do the chasing ?? Please send a link to buy

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว

      Chaz Virdee Armeg G225B4CC50 55mm Channelling Chisel www.amazon.co.uk/dp/B00MISDOX2/ref=cm_sw_r_cp_api_i_MoCwDbB7XYBQ6

    • @chazvirdee2012
      @chazvirdee2012 5 ปีที่แล้ว +1

      @@NBundyElectrical thank you

  • @03bestrob
    @03bestrob 5 ปีที่แล้ว +2

    What downlight are they you've fitted?

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว +1

      Robert Best bell down lights mate 👌 great lights

    • @03bestrob
      @03bestrob 5 ปีที่แล้ว +1

      @@NBundyElectrical Will have to give them a go. Who stocks them? V50's are my go too all day long.

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว +1

      My local supplier in Stafford, give me 2 and I’ll grab a link

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว +2

      www.lectri-call.co.uk/ProductDetails/?code=08187

    • @03bestrob
      @03bestrob 5 ปีที่แล้ว +2

      @@NBundyElectrical Cheers man, they look a dream...

  • @GunnyRabbit
    @GunnyRabbit 4 ปีที่แล้ว

    Do ya boots up!! Ya wouldn't be much good trippin over them running out if someone threw a grenade in there with ya!! Great vid.. Keep em coming!

  • @politic17
    @politic17 4 ปีที่แล้ว

    When a piece of rock is stuck inside my boot but I'm so freaking busy and don't have a stupid second to take it off and get it out, and I, eventually take it off and get rid of it after I'm done with everything always makes me laugh.
    PS: And the fact that I try to move it around my foot inside the boot so that it doesn't hurt me while I'm busy to simply remove it is hilarious, hahahahaha.

  • @micssticksnpipes
    @micssticksnpipes 5 ปีที่แล้ว +1

    Nice work.

  • @olibadcock9713
    @olibadcock9713 3 ปีที่แล้ว

    When installing some USB sockets they do say not too test the insulation resistance because they can interfere and in some cases cause issues

  • @StephenWaldenUK
    @StephenWaldenUK 5 ปีที่แล้ว +1

    Another interesting video Nick, keep up the good work.

  • @markyd2633
    @markyd2633 5 ปีที่แล้ว +1

    Another great vid...well done

  • @albertsteptoe3710
    @albertsteptoe3710 5 ปีที่แล้ว +1

    Cracking job again mate 👍👍

  • @charliemarie4360
    @charliemarie4360 3 ปีที่แล้ว

    I detest those nasty junction boxes - metal capping is nasty too.

  • @Benjamin-David
    @Benjamin-David 3 ปีที่แล้ว

    Does British code allow you to run a new radial path circuit?

  • @gd-bq7em
    @gd-bq7em 5 ปีที่แล้ว +1

    How many sockets do you usally say on a radial. is it a 20amp radial I always makes me think it's going to trip especially in a kitchen how many appliances would you say is ok off a radial
    Likening the videos mate keep em coming

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว +2

      greg davies as long as the cooker has its own supply being either a 6mm for higher rated ovens for its own 2.5mm radial if it’s over 2.6 kW then I find kettle micro and toaster fine to run on its own radial, but when u have a washer dryer and dish washer on to that much better running a ring 👍

    • @gd-bq7em
      @gd-bq7em 5 ปีที่แล้ว +1

      @@NBundyElectrical sound mate in my kitchen I have a small radial washer ,under counter freezer, microwave and the 3 amp spark for gas cooker I reckon that's about the limit lol

    • @gd-bq7em
      @gd-bq7em 5 ปีที่แล้ว +1

      @@NBundyElectrical also mate how deep do you go on your chasing in

    • @richardwilliamson3624
      @richardwilliamson3624 5 ปีที่แล้ว +3

      If in doubt run 4mm and up your OCPD

    • @dannybrown4124
      @dannybrown4124 5 ปีที่แล้ว +2

      @@richardwilliamson3624 if your doing that why not just make it a ring?

  • @ronaldomac4918
    @ronaldomac4918 3 ปีที่แล้ว

    Your video's are boss and very informative...... :)

  • @abbottfamily6317
    @abbottfamily6317 5 ปีที่แล้ว

    Why double up on the 1362 fuses, with one in the fused connection unit and one in the appliance plug?

  • @kennethkristensen5537
    @kennethkristensen5537 4 ปีที่แล้ว

    What is the brand and model the shorts you Are using?

  • @jcamerz
    @jcamerz 5 ปีที่แล้ว +1

    Top video 👍

  • @johnnomassive3797
    @johnnomassive3797 4 ปีที่แล้ว

    I love watching these videos cool guy and explanation

  • @philipallen6921
    @philipallen6921 5 ปีที่แล้ว

    if you have boxes next to each other link then using a galvanised coupler and bushes , bring one ring leg into each box and throught the coupler form the link, will we have to return to metal capping in some cases for the 18th , ps had some fun on kitchen electrical problems over the years good video thanks

  • @vicar19
    @vicar19 5 ปีที่แล้ว

    Stumbled upon your videos by accident. Subscribed instantly. Brilliant videos mate. All the best.

  • @_tmmy_
    @_tmmy_ 5 ปีที่แล้ว +1

    Great content👍

  • @adammccabe531
    @adammccabe531 5 ปีที่แล้ว

    New to channel great work finding those joints. Can i ask why did you only run a radial circuit when you where going back to dis board any way or did i miss somthing as kitchen has high demand items wouldnt a ring bw better? 👍👌😊

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว

      Adam Mccabe hey mate, being the washer and dryer are on their own ring and cooker is on a 6 mm didn’t see it necessary to be honest 👍

  • @robertsingleton2364
    @robertsingleton2364 4 ปีที่แล้ว

    Hiya how many d/sockets on a radial

  • @supersparks9466
    @supersparks9466 5 ปีที่แล้ว

    Another 20 years nick and you won’t be working past 3 let alone gone 6.30

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว +1

      Supersparks lol I’ve got a good few years left in me 👌

  • @liammartin9540
    @liammartin9540 5 ปีที่แล้ว

    Anyone got a link to the SDS drill bit he was using for chasing out the brick? TIA

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว

      Armeg G225B4CC50 55mm Channelling Chisel www.amazon.co.uk/dp/B00MISDOX2/ref=cm_sw_r_cp_api_i_ySVvDbNCZZRD2
      There you go bud

  • @bigdai85
    @bigdai85 5 ปีที่แล้ว +2

    Why is there no main isolator on that consumer unit?

    • @AndyK.1
      @AndyK.1 5 ปีที่แล้ว +1

      David Masson looked like an rcd being used as main switch. Not uncommon back in the day in a TT system.

    • @bigdai85
      @bigdai85 5 ปีที่แล้ว +1

      @@AndyK.1 Looks like someones replaced the main switch for an rcd at a later date to me. No discrimination between rcds.

    • @muzikman2008
      @muzikman2008 5 ปีที่แล้ว +2

      @@bigdai85 Discrimination? not very 18th edition?..lol ;-)

    • @bigdai85
      @bigdai85 5 ปีที่แล้ว +1

      @@muzikman2008 Haha you sound like my niceic inspector!

    • @ashmanelectricalservices4318
      @ashmanelectricalservices4318 5 ปีที่แล้ว +4

      @@bigdai85 Isn't is call 'selectivity' now?

  • @jamiedockerill4576
    @jamiedockerill4576 5 ปีที่แล้ว

    Hi nick. Good to see how people do things differently that’s why I watch these videos for ideas and different products ppl use in different areas. I use Makita chaser and dust extract works amazing had it for years so much easier and I always use oval rather than capping I can’t see the point in chasing a 50mm wide chase when you can do one line with the chaser and put in 25mm oval much better job to look at in my opinion.
    I also don’t chase across the wall at all I would have gone in the ceiling void and straight down to the hood supply.
    If I see you at elex I say hello 👋

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว

      Im gonna try the oval stuff soon I think, and yeah If u see me give me a shout 👌

  • @doncodman913
    @doncodman913 5 ปีที่แล้ว

    Hi . On your video at 14:30 you said a double socket under sink for dishwasher.... my sparky told me my kitchen failed because their was not an isolator switch above the kitchen surface to isolate the undercounter dishwasher. Wondered what your thoughts were. It is amazing the thought process of some people that think burrying junction boxes is acceptable. Look forward to hearing from you. Regards Don Codman

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว +3

      Hey don, to my knowledge a socket located in a cupboard ie socket fixed inside a kitchen cab not behind it, as long as it’s accessible it’s fine, it’s when there is a socket behind an appliance and it’s inaccessible so you would need a spur on work top to isolate it

    • @doncodman913
      @doncodman913 5 ปีที่แล้ว +1

      @@NBundyElectrical aaah ... many thanks .... I see the logic now. Many thanks . Have a good bank holiday.

  • @wayneosullivan1549
    @wayneosullivan1549 2 ปีที่แล้ว

    Nice job nick 👍

  • @carlgriffiths5427
    @carlgriffiths5427 5 ปีที่แล้ว

    How much would a job like this cost

  • @naiemar222
    @naiemar222 4 ปีที่แล้ว

    Nick you legend

  • @djukamali6341
    @djukamali6341 5 ปีที่แล้ว

    What brand and type of pliers do you use in 6:17 ?

  • @ivanthegreat79
    @ivanthegreat79 5 ปีที่แล้ว

    Well done. Learned from you. Keep it up. By the way what camera are you using please?

  • @whatevernamegoeshere3644
    @whatevernamegoeshere3644 4 ปีที่แล้ว

    20:42 My teammate on group projects seen on the left

  • @jamesworrell4773
    @jamesworrell4773 5 ปีที่แล้ว

    Hood isolation circuit, gies from FCU up then right angle to unswitched socket. Isn't that outside the permitted zones?

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว

      No bud, the permitted zone from the fused switch is straight up and zone for the socket is up, down left and right level with the socket

    • @jamesworrell4773
      @jamesworrell4773 5 ปีที่แล้ว

      @@NBundyElectrical I dunno I dont think so the zones state going from accessories or to walls horizontal or vertical therefore that right angle shouldn't be there. Look at you orm site guide it will not show anything like that

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว

      Page 82 on the on site Gide
      “ be protected by a 30 mA our RCD and installed in a zone either horizontally within 150 mil of the top corner wall or partition or vertically within 150 mil of an angle formed by two walls or run horizontally or vertically to an accessory or to consumer unit where the wall is 100 mil thick or less and location of the accessory or consumer unit can be determined from the reverse side the zoning arrangement is protected through the wall”

  • @dang8795
    @dang8795 5 ปีที่แล้ว

    What do you reckon to the wiha telephone pliers? Worth buying?
    Great video as per usual!

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว

      Yeah love them, good for poking and pulling not very good at doubling over 2.5mm

  • @jafarsunny1762
    @jafarsunny1762 4 ปีที่แล้ว

    great again nick

  • @jonesconrad1
    @jonesconrad1 5 ปีที่แล้ว

    Totally agree with J Beck's comment, keep the videos coming.

  • @MARTINA-gc3tq
    @MARTINA-gc3tq 5 ปีที่แล้ว

    what a great reason for not running rings especially in a kitchen......2.5 cable rated for max 24 amps running through a 32amp breaker......

    • @MrPete1664
      @MrPete1664 5 ปีที่แล้ว

      , it's 27 amps if clipped direct

    • @MARTINA-gc3tq
      @MARTINA-gc3tq 5 ปีที่แล้ว

      Peter Baker
      Still max 20amp breaker.

    • @MrPete1664
      @MrPete1664 5 ปีที่แล้ว

      Totally agree

    • @NBundyElectrical
      @NBundyElectrical  5 ปีที่แล้ว

      its on a 20amp breaker, not a 32

  • @otmanlara
    @otmanlara 5 ปีที่แล้ว

    Good work friend