Abhishek - i have found in you one of the best technical expert n brilliant communication skilled engineer i have found on TH-cam World of Knowledge, CONGRATS MAN 🍾🍾🍾🍾 love frm other side of the border. May God keep u happy n intact Ameen
@@electricalwithabhishekjoshi Dear Abhishek, _I have a tech query regarding transformer testing to calculate its internal winding & core losses _ also i wud request u to pls tag me when u make the video about my query, thanks .. : Has there been so far a scientific development for calculating transformer's internal losses at rated power and rated voltage? As core losses being calculated (and attached to traffo namplate) at no-load cannot give exact hysterisis & eddy current losses as the magnetic flux at rated power will be different, same for short circuit test - only 10 to 20% rated primary voltage is applied and so winding impedence losses (again in nameplate ) wil be different at rated primary voltage & rated power ..
Nice explanation sir thank you. But now a days digital education with animation and graphics so please provide that type of platform, like khan sir GS research. We are with you.
Sir my big confusing question is Jab 1000A ki ACB ko over load pe setting kiya 800A to iss setting value ki according S,I,G value set karna padega ya fir 1000A ki according set karna padega? Plz sir it's vry urgent..
Abhishek - i have found in you one of the best technical expert n brilliant communication skilled engineer i have found on TH-cam World of Knowledge, CONGRATS MAN 🍾🍾🍾🍾 love frm other side of the border. May God keep u happy n intact Ameen
Thank you so much Ammad Asim.. 🙏
@@electricalwithabhishekjoshi Dear Abhishek, _I have a tech query regarding transformer testing to calculate its internal winding & core losses _ also i wud request u to pls tag me when u make the video about my query, thanks .. : Has there been so far a scientific development for calculating transformer's internal losses at rated power and rated voltage? As core losses being calculated (and attached to traffo namplate) at no-load cannot give exact hysterisis & eddy current losses as the magnetic flux at rated power will be different, same for short circuit test - only 10 to 20% rated primary voltage is applied and so winding impedence losses (again in nameplate ) wil be different at rated primary voltage & rated power ..
the best teacher in youtube....
Very good explained
Brilliant explanation... simple language which helps a layman as well understand
Generally good video.
U shld hv explained how the figure of 2.55 is arrived at ?
Also need to make a circuit when it is under fault ??
Very informative video
Sir please make a video on how to start an Acb & Vcb
The way you explain no one explains in that way....keep going brother..
You explain quality very easy and adorable
Well done 👍
Bro. Thanks for the very important inputs.
You are a born lecturer. thanks once again
Thanks sir aaj concept clear ho Gaya🙏 love you sir❤️
Nice explanation sir thank you. But now a days digital education with animation and graphics so please provide that type of platform, like khan sir GS research. We are with you.
Very nice illustration on circuit breaker current, thanks a lot 👍
Sir,
Kindly make video on Ics, Icu, Icw with respect to breaker
Bhut aach ta video sir
Best explanation
Well defined difference between making and breaking current capacity with fine line between them.
Your way of Explanation is very very good, really amazing 🤩, thankyou so much for this video and keep it up
Dear Abhishek
OC-0.3sec-CO
Now during Close open cycle the CB interrupt breaking current or making current current?
Thank you for such a beautiful explanation. Also please make a video on duty cycle test.
Very Informative Bro.. Thank you for guiding us.
Thanks a lot for explaining this sir
Fabulous work done sir
Thanks bro. Nicely explained
Most welcome..
abhishek great knowledge
Can you please made one video about satutary compliance about DG
electrical inspector visit
Excellent speech, thank you .
Sf6 circuit breakers name plate explained sir ❤plz...
Sir mccb ka breaking capacity kaise calculation karna hai. Please bataiye
Very nice explained.
How to find values of making and breaking current of Breaker according to existing electrical load.
Please make video.
Okay..
PLEASE EXPLAIN
Out of phase breaking current. & Line
charging breaking current OF cb?
Thanku sir ❤️
Bro. Can you make detailed video on ACB operation step by step
Excellent sir
Well explained sir!
Sir pls tell me How we can select the braking capacity rating of a MCCB
Sir v c b ki wireing Pannell c.t wire ka kya coad hota hai.
Please make the video on ATS panel
Sir Ek VCB hota ek VCR
Dono ka difference aur main Khan pe VCR choose krunga
Very nice 👍👍👍
HT AND HVAC IS MY WORLD
Sir plz upload video how to read breaker control ckt
👍👌good information thanks
Excellent sir, thanks
Vfd parameters video banaa dijiye sir plz
Sir i have question why we our Relay setting hig set and low set can you explain it
Bhai konse business aur unit me ho
Thanku❤
Most welcome Shruti..
Dear Sir,
I have a question related to timer
When we do operation o/c time value is less as per operation time of open or close?
Thank u so much
Nicely explained 👍
Thanks ❤️
Circuit breaker ka making & breaking capacity kitna hona chahiye
Thanks for the information
Nice
nicely explained
Sir switch ki complete testing pr video a to z thk please
thank you sir
Nice video sir could you make me understand about bus reactor
Okay vishal.
We will make video on this.
@@electricalwithabhishekjoshi thx sir actually sir I'm also working at 765/400/220/33kv sub-station
Thank you
Sir my big confusing question is
Jab 1000A ki ACB ko over load pe setting kiya 800A to iss setting value ki according S,I,G value set karna padega ya fir 1000A ki according set karna padega?
Plz sir it's vry urgent..
Bro your In 1000 rating of c.b but your setting requirement 800A so your In 800A all setting consider
Fault condition me 2.55time current carry karega so my question is without any fault condition making current kitna lega
How to breaking current calculated
Sir playlist m relay protection wali video nahi dikh rahi h
Excellent 👍👍👍
Thank you....
Thank u sir...
How to calculate the breaking capacity of breaker
sir what is the" Energy class "of circuit breaker?
👍👍👍👍
❤
It depends on X/R ratio.
Please make video in English
🙏🙏
Kaysa contact Kara apsa sir
Sir ...why it is 2.55
what is the meaning of 380 /132 substation
It means 380KV to 132KV substation
icu Ics Icw Ui Ue Uimp In ye sab ka kya matlab hota hai
Thank you sir