How to bypass a Defrost Heat Pump Board to allow cooling

แชร์
ฝัง

ความคิดเห็น • 77

  • @michaelcostello6991
    @michaelcostello6991 5 ปีที่แล้ว +5

    Good video. It clarifies the functions of the defrost board and the fact that it is just needed really for heating and some safety interlocks

  • @zmanjz2001
    @zmanjz2001 3 ปีที่แล้ว +5

    Great tutorial my Board went out. It's on backorder and it's been 102° here. This worked great and the temp is dropping as I type. Thank you!!

    • @Alienspecies635
      @Alienspecies635 2 ปีที่แล้ว

      I’m about to try this tonight for a customer that got a bad board on a new unit 🤦🏻 3-5 days for the board to get in then I have to go pick it up and install it

  • @Ajax2341
    @Ajax2341 6 ปีที่แล้ว +1

    Thank's Good Video. Ive worn out a couple of supercool slide rule already. a lot of information on that card. I use it all the time.

  • @sultanramza9379
    @sultanramza9379 8 ปีที่แล้ว +2

    Thank you for this video. I followed the steps and it worked perfectly. Just two issues I'd like to highlight to help others:
    1. Please refer to the wiring schematic for specific colors of the reversing valve. Mine were black.
    2. Also I blew the fuse at the a/c handler in this process so my thermostat wasn't working. One I found that and replaced it everything worked well.

  • @michaeljennings3485
    @michaeljennings3485 6 ปีที่แล้ว +14

    Good video but when you connected the common lead for the thermostat you connected it to the black lead on the board and not to the thermostat wire I think it was the grey wire

    • @ricoswavae512
      @ricoswavae512 3 ปีที่แล้ว +1

      Yeah i saw that too, good catch.

  • @andrewlaurice8227
    @andrewlaurice8227 10 ปีที่แล้ว

    Great information! Thanks.
    Andrew Laurice

  • @btknowlton
    @btknowlton 9 ปีที่แล้ว +8

    If you have comments that are helpful or suggestions on how to improve a video please post it but if you don't have anything valuable to add then please keep it to your self.

  • @herbertvega749
    @herbertvega749 3 ปีที่แล้ว +2

    Good job !!!!! thank you for sharing !!!!!

  • @manuel12888
    @manuel12888 2 ปีที่แล้ว

    Thank you so much for your help

  • @RifullOfTheWest
    @RifullOfTheWest 6 ปีที่แล้ว

    @SuperCool Slide Rule" can you make a video on how to make yourself a light wieght, small home built window defogger wire setup. I have a velomobile I need to make a defogging wire setup, but can't figure out how to do it, and where to get the wire.

  • @Onatena
    @Onatena 2 หลายเดือนก่อน

    thanks for this great Video
    I was struggling with one heat pump
    I was getting 24v but the board was not working well, after watching this video I end up bypassing it and it worked 😂

  • @nitrofan917
    @nitrofan917 5 ปีที่แล้ว

    Do the red and blue wires that you jumped get plugged back into the relay? Thanks.

  • @TalentNetworked
    @TalentNetworked ปีที่แล้ว

    Great videos. Can an ohms OL on a Solenoid cause the 3amp fuse in the AH to keep failing? Can’t get Low Voltage on Contactor, changed contractor, same issue.

  • @mickeylojkar5769
    @mickeylojkar5769 4 ปีที่แล้ว +5

    Why get a common from the board if your bypassing the other wires? Shouldn't you get common from the tstat wires?

    • @1251PrintHouse
      @1251PrintHouse ปีที่แล้ว

      Yes you should.I was thinking the same thing

  • @gotchaplumber
    @gotchaplumber 4 หลายเดือนก่อน

    Great video!

  • @sarahgracebrooks2629
    @sarahgracebrooks2629 8 ปีที่แล้ว

    What if you don't have a RV and your indoor fan is wired with the unit....Package/A/C and GAS??

  • @aadilali1510
    @aadilali1510 7 ปีที่แล้ว

    THANK U SO MUCH

  • @matthewcrews4034
    @matthewcrews4034 3 ปีที่แล้ว +1

    Hi how are you can you make a video .showing how to bypass the condensor fan relay on board for defrost and add and external relay to allow cooling and heat I've replaced this carrier board 3 times in a year and a half .just put a new board and new condensor fan motor just in case old fan motor was pulling to high of laps causing the relay to fail . However the board failed a week later anyway I've had the whole system checked over and voltage tested they found no issues but the board keeps failing the last unit I had the man installed a external relay for the fan which worked perfect until I had to get a new unit due to outdated freon thanks and I hope you can help

  • @PBS-nm1uu
    @PBS-nm1uu 6 ปีที่แล้ว

    please do one on how to read the control board.

  • @aarongreen8784
    @aarongreen8784 10 ปีที่แล้ว +3

    Okay, in the beginning you moved the black (C) wire out the way, @ 1:43 to 1:53, and tried to put the red wire from the contactor to the light blue (C) wire from the thermostat. Then later you put the black (C) wire from the board with just the red and orange (C) wire and the light blue (C) wire was not connected. Now which wires need to be connected in that stage? All light blue, black, red and orange which equals four wire or does just three need to go together, black or light blue with red and orange?

    • @drouse365
      @drouse365 5 ปีที่แล้ว

      Aaron Green Just the light blue,orange, and red. Forget the black coming from molex plug (board).

  • @RM-gw8ue
    @RM-gw8ue 3 ปีที่แล้ว

    How can you bypass the control board and still retain the ability to use the heat strips ?

  • @romeshthomas7949
    @romeshthomas7949 7 ปีที่แล้ว

    How to wire up a hot water coil to an air handler using two relays and an aquastat

  • @JuanDiaz-vm1pv
    @JuanDiaz-vm1pv 4 ปีที่แล้ว +1

    Thank you for your time. Question: my AC/Heat Pump is freezing up around the indoor unit coil. No AC at all. Thermostat and inside fan are working, filter and A-frame are clean, drain plug is NOT clogged. Outside fan and compressor are working too. I haven't measure capacitance, but assume dual capacitor is good since compressor and fan both run. I haven't check for low refrigerant yet (R-410A). What could possibly be the problem? Would the defrost control board have anything to do here (it's spring time and only inside is freezing). Thank you much in advance!

    • @bhaskarper909
      @bhaskarper909 2 ปีที่แล้ว

      What did you do to fix it, I have similar problem?

    • @musclemoney4479
      @musclemoney4479 2 ปีที่แล้ว

      @@bhaskarper909 low refrigererant

  • @abnergallo6960
    @abnergallo6960 ปีที่แล้ว

    Thank you so much

  • @louisg4567
    @louisg4567 10 ปีที่แล้ว

    you right Aaron he messed up.. the red wire from the contactor is suppose to connect to the common on the thermostat wire coming from the air handler and that completes your 24v coming from the transformer the other yellow wire which is your call for cooling he has correct

  • @viper22304
    @viper22304 5 ปีที่แล้ว +1

    Thanks for the video. Can you do this with rudd and rheem?

  • @giorgioguidolin
    @giorgioguidolin 3 ปีที่แล้ว

    Thank you

  • @michaelpope2946
    @michaelpope2946 5 ปีที่แล้ว +2

    Shouldn't you connect to the valve end of the orange wires not the board end? I tried this and burned up my transformer not sure what I did wrong.

    • @boobieloc9734
      @boobieloc9734 3 ปีที่แล้ว

      That's what I'm thinking.. because how would it power the valve. why wire the board if you're bypassing board

  • @chadoxdcfan
    @chadoxdcfan 4 ปีที่แล้ว

    Could I just jump yellow and orange and leave common alone? Shouldn't common still be present no matter what?

  • @WilliamBelliard
    @WilliamBelliard 9 ปีที่แล้ว +2

    I enjoyed your video thank you for the education, I do have a question. I have a temp star unit and I replaced the contractor, defrost board and fan board along with a new honey well digital thermostat. All looks well, the ac blows cold air but I did notice that the condenser fan is always running/spinning even when the blower inside is not blowing anything. Also the air power of the air coming out of the vents inside is not as strong and the other units. Can you please help

    • @btknowlton
      @btknowlton 9 ปีที่แล้ว +3

      William Belliard
      You may want to ensure that the wires feeding the condenser fan are connected to the load side of the contactor instead of the line side (they should be on the side opposite the incoming high voltage wires). Hope this helped.

    • @WilliamBelliard
      @WilliamBelliard 9 ปีที่แล้ว

      Bryan Knowlton Thank Bryan. Is the load side L1 or L2 correct? I mean have you heard of this? Could the fan motor be bad as well? Or if it spins that means its good. By making these changes will it increase the speed of the fan outside thus increasing the air blowing inside?

    • @michaelkranz2529
      @michaelkranz2529 7 ปีที่แล้ว +2

      Oh ya , if you can speed up the out door fan , it will surely blow like hell inside , dude stay away from this trade , your scaring me .

    • @luishernandez5394
      @luishernandez5394 ปีที่แล้ว

      Sounds like you wired the low voltage incorrectly and by that I mean maybe at the furnace you installed the y wire on the r terminal instead of it being on y and therefore your your condenser is always running. Or you wired your fan high voltage going too the line side of your contactor that you replaced something is mis wired need more input.

  • @OcRefrig
    @OcRefrig 6 ปีที่แล้ว

    Good video !

  • @christopherpaul2938
    @christopherpaul2938 9 ปีที่แล้ว +24

    Bryan the way you ecplained it is for.experienced technicians, it seemed a bit confusing, the easiest way would be to just unplug the two orange reversing valves wires from the defrost board and simply connect them on the each side of the contactor so the valve can get its 24 volt. The valve will always be energized when ever there is call for cool. Great vedeo though!!

    • @SombraLocs
      @SombraLocs 8 ปีที่แล้ว +3

      exactly!

    • @michaelkranz2529
      @michaelkranz2529 7 ปีที่แล้ว +1

      Ya I think this guy want's to show off his electrical engineering degree , but any tech can do that task in way less moves than his dumb ass video , Oh ya , why are we bypassing the control anyway ?

    • @Seawolfvital
      @Seawolfvital 6 ปีที่แล้ว

      Christopher Paul what if condenser fan motor relay stuck open? U energized reversing valve but cond fan motor won't run. I would never bypass defrost bord(SW Florda) unless it's late call and I'm unable to get replacement part (most cases -next day in the morning it is installed).

    • @osiriscorporation1265
      @osiriscorporation1265 6 ปีที่แล้ว +1

      simplicity at its finest, thanks smart brother!!

  • @danpan4425
    @danpan4425 6 ปีที่แล้ว

    Can you bypass the board for heating and cooling?

    • @Ggg77777
      @Ggg77777 3 ปีที่แล้ว +1

      Yes but different way

  • @saltrue1555
    @saltrue1555 6 ปีที่แล้ว

    Nice tks

  • @manna5610
    @manna5610 7 หลายเดือนก่อน

    So, I wanted to bypass the defrost board for heating, then just leave the reversing as is.

  • @DJatVRR
    @DJatVRR 9 ปีที่แล้ว +1

    You should make another video with a more simplistic explanation of a simplistic solution and correct your mistake while you're at it.

  • @914peru
    @914peru 10 ปีที่แล้ว

    thanks for you help I'll buy you slide rule I'll buy my defrost board in October

  • @Carskinify
    @Carskinify 9 ปีที่แล้ว +1

    The defrost cycle doesn't work during the summer so if you just use the summer ac,why would you need to bypass the defrost cycle?

    • @acoustic4037
      @acoustic4037 9 ปีที่แล้ว +1

      Carskinify You don't "bypass the defrost cycle" as you put it. You bypass the defrost board. The board can burn out (a relay on the board) and not pass power (24v) to energize the main contactor and not allow the system to run or cool at all. I'm still new at hacks so I just get the replacement board and install it. People go hot for a few days, thats life.

    • @foghornleghorn8536
      @foghornleghorn8536 9 ปีที่แล้ว +1

      acoustic4037 Sounds like you should probably be doing installs. Leave the service work to an actual technician.

    • @acoustic4037
      @acoustic4037 9 ปีที่แล้ว +1

      Foghorn Leghorn your comment serves no purpose except to insult. Why bother if you can't be constructive or helpful.

    • @foghornleghorn8536
      @foghornleghorn8536 9 ปีที่แล้ว +1

      Merely pointing out that by making this statement "People go hot for a few days, that's life." You clearly indicated that you should not be a service technician.

  • @OnePointLander
    @OnePointLander 2 ปีที่แล้ว

    Why would a defrost board fail?

    • @jeffjula
      @jeffjula 2 ปีที่แล้ว +1

      because it's a man-made item.

  • @outlawguitar1
    @outlawguitar1 9 ปีที่แล้ว +1

    Something wasn't right, I wired it exactly after spending an hour repeating the steps, plugs mine in and 60 seconds later, a loud pop!!! Maybe redo this video and rethink the wiring and be a little more in detail, thanks

  • @trickyanims7852
    @trickyanims7852 8 ปีที่แล้ว +2

    Basically just take the low voltage cooling wire out of the board and connect it at the contractor. 🆒

  • @BradMillsXRP
    @BradMillsXRP 9 ปีที่แล้ว +1

    I tried this and it burned my house down. So my laywer is wanting your General Liability policy number

    • @michaelkranz2529
      @michaelkranz2529 7 ปีที่แล้ว

      Excellent reply , I love it , people like him don't realize that people shouldn't be attempting modification like that , leave it to qualified service company , I would sue the shit out of him , he is an accomplice to disaster.

  • @davidjackson3069
    @davidjackson3069 2 ปีที่แล้ว +4

    You just cut half the words in the unit when all you had to do was run the "Y" wire directly to the contactor. Land the fan wire on the L1 terminal of contactor. Then you could have placed a common wire on the opposite side of the contactor and boom when the contactor pulls in you have air conditioning now you have to unspice all those wires and fix it all back ridiculous amateur status.

    • @johnj2496
      @johnj2496 9 หลายเดือนก่อน

      what about the reversing valve wire
      just move the input wire down to the extra connection next to the yellow control wire on contactor

  • @kaster2014
    @kaster2014 4 ปีที่แล้ว

    Good video ... but very bad explanation

  • @hg2.
    @hg2. 5 ปีที่แล้ว +1

    Not good for beginners. "Don't do this at home.