Extension Lead Repair - MK Panel Sockets

แชร์
ฝัง
  • เผยแพร่เมื่อ 21 ก.ย. 2024

ความคิดเห็น • 73

  • @colinritchie1510
    @colinritchie1510 ปีที่แล้ว +5

    Loved the "blowing away the asbestos dust" comment and also not aligning the screw heads just to annoy people! Brilliant as ever Mr Ward.

  • @Xclub40X
    @Xclub40X ปีที่แล้ว +17

    JW you are the EXTENSION to our lives. . .thank you sir for your great content . . . .

  • @gregf9160
    @gregf9160 ปีที่แล้ว +9

    Nice heavy-duty unit 😀 glad it's salvageable, and has a new lease of life. I would have been _very_ reluctant to have just tossed it away 👍

  • @tazz1669
    @tazz1669 ปีที่แล้ว +5

    Amazed you found sockets to fit, i wondered how you were going to replace them

  • @Mike_5
    @Mike_5 ปีที่แล้ว +2

    Serious cable at 2.5mm ready for heavy duty action - Nice one JW

  • @andyking8797
    @andyking8797 ปีที่แล้ว

    I enjoy watching your videos,. In particular I found your videos explaining lighting circuits uploaded several years ago very informative and useful in helping me extend my lighting circuit to include the loft. Lighting circuits were something I was unsure of and had never tackled before, your explanation on the subject helped enormously. 👍

  • @lumpyfishgravy
    @lumpyfishgravy ปีที่แล้ว

    You're right - that's a dual-branded Fluke-Robin unit, getting on for 20 years old. Good to see it still rocking.

  • @andrewschannel3635
    @andrewschannel3635 ปีที่แล้ว +16

    Disappointed that you blew the asbestos away, I would normally keep it to sprinkle on my dinner.

    • @farerse
      @farerse ปีที่แล้ว +1

      it's now saturated in the breathing air

  • @dollarama8652
    @dollarama8652 ปีที่แล้ว +5

    WOW! my neighbor sold his parents house, gave me all sorts of old goodies form the basement... this was one of the things :o

  • @andytownsend9163
    @andytownsend9163 ปีที่แล้ว +2

    Love those big wood screws holding the panel on, when im working at dads house everything is screwed in/on with flat head wood screws. Cheers JW 🍻 👍

  • @pikricky
    @pikricky ปีที่แล้ว +1

    Such a pity an IP65 outdoor socket couldn't have been mounted on there somehow,would have made all the difference to stop water or moisture getting in through the cpc socket,another great video,glad you are back John

  • @walseee
    @walseee ปีที่แล้ว +1

    Your voice goes from low to higher pitch every sentence.
    Great video, it was very entertaining

  • @benpatana7664
    @benpatana7664 ปีที่แล้ว +2

    Good job John. Should provide years of further service!

  • @paulf2529
    @paulf2529 ปีที่แล้ว +15

    I think the dust in the cable is actually just humble talcum powder.

    • @AngDavies
      @AngDavies ปีที่แล้ว +9

      Which, to be fair, is sometimes contaminated with asbestos, particularly industrial grade stuff like that. So probably best not to breathe it in :/

  • @Jako1987
    @Jako1987 11 หลายเดือนก่อน +2

    21:14 I call that 90% ruling. If you don't try to do everything perfect you get so much more done. 😎

  • @farerse
    @farerse ปีที่แล้ว +1

    I like these repair videos with wiring and tidying up

  • @shaun30-3-mg9zs
    @shaun30-3-mg9zs ปีที่แล้ว +1

    Nice repair ,looking good .Good work John👍.

  • @isoguy.
    @isoguy. ปีที่แล้ว

    Great tutorial, pleased to see you back..

  • @Petertronic
    @Petertronic ปีที่แล้ว +3

    Nice repair, well worth doing.

  • @imbenshephard421
    @imbenshephard421 ปีที่แล้ว +7

    No reel surprises here!

    • @Martin-oo4kn
      @Martin-oo4kn ปีที่แล้ว +2

      I see Watt you did there!

  • @HA05GER
    @HA05GER ปีที่แล้ว +2

    You know its old when its got domed flat heads back when stuff was built to last.

  • @Saravananmanivel135
    @Saravananmanivel135 ปีที่แล้ว +1

    With love from India

  • @skyll4141
    @skyll4141 9 หลายเดือนก่อน

    nice job. can you do more setting fire to random faulty electrical items please.

  • @alanwhite4427
    @alanwhite4427 ปีที่แล้ว +1

    Nice video, keep up the good work 👍

  • @6A8G
    @6A8G ปีที่แล้ว +1

    Thank you for this John, not only smartened up but safened up also. You didn't feel obliged to strip the '70's orange paint off to give it a 21st-century feel? Nice job sir:)

  • @richardbrobeck2384
    @richardbrobeck2384 ปีที่แล้ว

    Nice repair !

  • @markpunt9638
    @markpunt9638 ปีที่แล้ว

    Just lubricate the old ones? A squirt of magic spray?

  • @robputt
    @robputt ปีที่แล้ว +2

    Does the paint on the black panel affect it's CPC arrangements? (I presume it is normally bonded via the screw to the socket if it had bare metal available to contact with)

    • @jeffeloso
      @jeffeloso ปีที่แล้ว

      I agree.

    • @kevvywevvywoo
      @kevvywevvywoo ปีที่แล้ว

      it probably passed the bond tests in the factory as it was and the bean counters decided the seperate earth lead was an unnecessary expense.

  • @David.R.H
    @David.R.H ปีที่แล้ว

    Fascinating

  • @Xclub40X
    @Xclub40X ปีที่แล้ว +3

    This is a REELY good video. . . I hope you all agree

  • @christopherhulse8385
    @christopherhulse8385 ปีที่แล้ว +1

    At seat socket outlets on trains use these same round MK types.

    • @paulf2529
      @paulf2529 ปีที่แล้ว

      I knew I had seen them somewhere.

  • @IC225
    @IC225 ปีที่แล้ว

    "asbestos dust found in many cables".....i had to rewind that a few times lol, had me for a few seconds did that.....thatll make amateur DIY folks cry over wiring/re-wiring things up

  • @seanoconnor8843
    @seanoconnor8843 ปีที่แล้ว

    I ❤ JW

  • @Marcel_Germann
    @Marcel_Germann ปีที่แล้ว +2

    Twin-ferrules will also prevent that the wires come apart over time.

    • @mernokimuvek
      @mernokimuvek ปีที่แล้ว

      I have seen some cheap chinese ferrules which cut a few strands after crimping. When I make something for myself that only I will use I don't bother with ferrules.

    • @Marcel_Germann
      @Marcel_Germann ปีที่แล้ว

      @@mernokimuvek For me it is easy, I purchase ferrules according to DIN 46228. Everything is normalised:
      -dimensions and tolerances
      -materials
      -colour code of collars for the different conductor sizes.
      kvt-pro.ru/pdf/standarts/din-connection-46228-4-1990-09.pdf

    • @TestGearJunkie.
      @TestGearJunkie. ปีที่แล้ว

      @@mernokimuvek So get decent ferrules. Always use them here.

  • @roberthuntley1090
    @roberthuntley1090 ปีที่แล้ว

    OFF TOPIC - John do you know how to submit suggestions for the next UK Wiring Regulations review (and if so could you please forward this on). Thanks in advance.
    I was looking at an American TH-cam video about solar batteries, and in the pre-production phase of development they are working in batteries that take power from a wall socket when charging, and deliver power back to that socket to power the house later on. Technically, this should work AOK, but seems to be a concept that was never considered when the wiring regulations were written. Suggest that the idea needs expert scrutiny when the regulations are next reviewed. I don't believe they ever considered feeding power into a wall socket (and obviously, the device would need some pretty secure interlocks to prevent it powering up the plug pins when away from the socket.
    PS - They also mentioned that it could be used with a time of use tariff. The concept was it is a portable battery you can take with you when you move house. It looks to be a year or so away from going on sale.

    • @jwflame
      @jwflame  ปีที่แล้ว

      Suggestions or corrections should be sent to the IET, details on page 2 of BS7671.
      What you are describing is a product, which is not covered by the scope of BS7671.

    • @roberthuntley1090
      @roberthuntley1090 ปีที่แล้ว

      @@jwflame Many thanks for coming back so quickly.

  • @TestGearJunkie.
    @TestGearJunkie. ปีที่แล้ว

    What, no ferrules..?

  • @suchcone
    @suchcone ปีที่แล้ว +2

    Snazzy shirt!

  • @ConfidentialMeerkat
    @ConfidentialMeerkat ปีที่แล้ว +2

    Did anyone else hear the high pitch squeal when he turned the rcd on?

    • @ruben_balea
      @ruben_balea ปีที่แล้ว +2

      That was the beeper on the tester

  • @giz177
    @giz177 ปีที่แล้ว

    Any content coming on fault finding for AFDD trips how would you test a circuit for that ?

    • @jwflame
      @jwflame  ปีที่แล้ว

      No, because there is no way to test for something that trips an AFDD. An arc fault is only present while the circuit is energised, once switched off it won't be there.

  • @tarnmonath
    @tarnmonath ปีที่แล้ว

    The earth pin does play a part in opening the shutters in MK sockets. The shutters do require that both conducting pins are pushed home at the same time time, but they still remain locked in position until the earth pin has been pushed in. Thus the shutter mechanism is an enhancement on the original BS1363 specification, not an alternative to it.

    • @temp06j723-pmeighttq
      @temp06j723-pmeighttq 11 หลายเดือนก่อน

      Really?
      Then how on earth is 2-pin plugs be possible plugged into these kind of sockets??
      (I do see 'grooves' for 2-pin insertion on those LN shutters)

    • @tarnmonath
      @tarnmonath 11 หลายเดือนก่อน

      @@temp06j723-pmeighttq Sorry. I wasn't clear. I'm talking about British sockets, which Alec correctly said cannot be used unless the earth pin is inserted first, releasing the shutters.

  • @LoftInsulation-pj9dj
    @LoftInsulation-pj9dj ปีที่แล้ว +2

    Nice video john. However bear in mind that this type AC RCD is still not suitable for drills and vacuum cleaners because most power tools are coming with BLDC motors which work on DC and have some sort of circuitry. This extension lead is obsolete.

    • @gap9992
      @gap9992 ปีที่แล้ว

      Just fit a standard plug then and rely on the RCD in the Consumer Unit?

    • @_chrisr_
      @_chrisr_ ปีที่แล้ว +2

      You can have both RCDs providing protection - the type AC one may not be effective for certain types of loads where a DC component may be generated but if the installation has a type A RCD upstream then it wouldn't be afffected by the DC current present and so still provide protection. It's worth bearing in mind that many installations in UK will have type AC RCDs only and it is only mandatory for new circuts to have type A fitted so whilst it could be improved upon I wouldn't say it is obselete either
      .

  • @jeffeloso
    @jeffeloso ปีที่แล้ว +1

    Why was the black circular plate not explicitly earthed?

    • @samuelfellows6923
      @samuelfellows6923 ปีที่แล้ว +3

      Through the socket screws ✅

    • @jeffeloso
      @jeffeloso ปีที่แล้ว

      @@samuelfellows6923 But the paint is insulating the screws. I would have thought a dedicated earthing screw could have been added. The painted wood screws would have been useless for earthing too.

  • @POLITICAL-BIAS.
    @POLITICAL-BIAS. ปีที่แล้ว +4

    Good for another 50 years, I reckon.

  • @smellbag
    @smellbag ปีที่แล้ว

    Messrs. Cleese and Atkinson have no better inspiration for material, than the legendary John Ward.

  • @pradolover
    @pradolover ปีที่แล้ว +1

    Asbestos dust 😂 then blowing it away 😅😅😅😅😅

  • @line10cls
    @line10cls ปีที่แล้ว

    Colours on test lead ? to what standard ?

    • @jwflame
      @jwflame  ปีที่แล้ว +1

      All of them

    • @TestGearJunkie.
      @TestGearJunkie. ปีที่แล้ว

      Test leads don't have to adhere to a standard. It's assumed those using them have a clue.

  • @jensschroder8214
    @jensschroder8214 ปีที่แล้ว

    how do the English make a ring circuit with an extension lead ?
    In all other countries there are only branches and therefore a maximum of one 15A/16A fuse in the fuse box.

    • @tazz1669
      @tazz1669 ปีที่แล้ว +4

      There is a fuse rated for the flex in the plug, in this case with the bigger cable it will be 13 amp

    • @Mark1024MAK
      @Mark1024MAK ปีที่แล้ว +3

      We also have spur circuits that branch off the ring. All our 13A plugs have fuses in them.

  • @drcrusherdata
    @drcrusherdata ปีที่แล้ว

    say it's from the 1970's being orange.

  • @Droningonuk
    @Droningonuk ปีที่แล้ว +1

    Surprised that flex just comes through a metal hole without a grommet