Why we use mostly YNd1 to Dyn11 or YNd11 to Dyn1 this vector group in Transmission line

แชร์
ฝัง
  • เผยแพร่เมื่อ 24 พ.ย. 2024

ความคิดเห็น • 43

  • @supremesoul1835
    @supremesoul1835 หลายเดือนก่อน +1

    nice one brother. so much appreciate your effort to make us enlighten.👌🏿

    • @baranitech
      @baranitech  หลายเดือนก่อน

      thank you and most welcome

  • @muhammadismail630
    @muhammadismail630 3 ปีที่แล้ว +2

    I really appreciate your teaching method and I am watching your videos everyday . Wish you best health.

    • @baranitech
      @baranitech  3 ปีที่แล้ว

      thank you very much

  • @petarsimic2303
    @petarsimic2303 5 ปีที่แล้ว +3

    Thanks for video! Can you cover all transmision line protection and automation functions in detail after you finish series with transformer protection lectures?

  • @rukmagoud
    @rukmagoud 3 หลายเดือนก่อน +2

    There is a mistake in drawing . You are showing Ynd11 from generator. Generator is star connected and it is connected to step up transformer with vector group Ynd11. Here Y is always high voltage side. But in drawing you are showing in reverse way. Please check

    • @baranitech
      @baranitech  3 หลายเดือนก่อน

      this is ref. schematic diagram from site

  • @user-ur2mc2bo7e
    @user-ur2mc2bo7e ปีที่แล้ว +1

    Hi thanks for the video ,but I didn’t get why we need phase displacement. If we transmit it with zero degrees and distribute it with zero degrees what will happen?

    • @baranitech
      @baranitech  ปีที่แล้ว

      when we make DY transformer it will naturally make phase displacement.

  • @tufailalam6438
    @tufailalam6438 5 ปีที่แล้ว

    Thank you for this video... Please upload more videos like this... Please make video on distance relay

  • @yuvanraj9966
    @yuvanraj9966 2 ปีที่แล้ว +1

    Thank you sir your video very like fully that

    • @baranitech
      @baranitech  2 ปีที่แล้ว

      your most welcome

  • @wongsabarchannel1335
    @wongsabarchannel1335 3 ปีที่แล้ว +2

    When Step up transformer (11/500kV) is YNd1, then Unit Aux Transformer (11/6.3kV) is Dyn11, the Distribution Transformer (6.3/0.4 kV) Should use Dy11 or Dyn5 or we can used both, what is the Reason?
    Above is for in SLD.

    • @baranitech
      @baranitech  3 ปีที่แล้ว

      it will compensated the angle different

    • @wongsabarchannel1335
      @wongsabarchannel1335 3 ปีที่แล้ว +1

      @@baranitech It still not answer my question.. Can you check my question?
      Should use Dy11 or Dyn5 or we can used both, what is the Reason?

    • @baranitech
      @baranitech  3 ปีที่แล้ว

      @@wongsabarchannel1335 you can use DYn11 or DYn5 . over there. both have same value only.

    • @wongsabarchannel1335
      @wongsabarchannel1335 3 ปีที่แล้ว

      @@baranitech What different when use Dyn5 and Dyn11? The advantage maybe

    • @rjshtk
      @rjshtk ปีที่แล้ว

      @@wongsabarchannel1335 The Dyn5 trafo can be used to supply the excitation system with incoming ac that gets converted and controlled by thyristors. The harmonics produced in the exxcitation circuit due to the semi con devices is prevented from reflecting on the upstream CTs by using the Dyn5 type transformer. The Dy11 is used for normal station auxiliary loads.

  • @gopalpillai9190
    @gopalpillai9190 ปีที่แล้ว +1

    Good video.

    • @baranitech
      @baranitech  ปีที่แล้ว

      Thanks, and welcome.

  • @rjshtk
    @rjshtk ปีที่แล้ว +1

    at 5:30 of the video, you have shown the Generator stator side of GT as Star. That would be wrong. It has to be delta!

    • @baranitech
      @baranitech  ปีที่แล้ว

      if you use GT as Delta then distribution should be low voltage. in this video i have show for HV

  • @Nikhilkumarsah-vk5ti
    @Nikhilkumarsah-vk5ti 11 หลายเดือนก่อน +1

    Very Well Xplained!!! can you Have the video over other

    • @baranitech
      @baranitech  10 หลายเดือนก่อน

      i will try to make for other also.

  • @DebjitDas93
    @DebjitDas93 4 ปีที่แล้ว

    What will happen if the phase shifts to 60 deg in a combination?

  • @sagarraj.trajtt9634
    @sagarraj.trajtt9634 4 ปีที่แล้ว +1

    Thkz for the information

  • @varadharajanelectricalengi5954
    @varadharajanelectricalengi5954 3 ปีที่แล้ว +1

    This is the most wanted explanation 💪🙄🌎🌏🐸😲🤔

  • @joaquinsebastian9209
    @joaquinsebastian9209 4 ปีที่แล้ว +1

    Hi does it really requires to bond Neutral and Earth in the Secondary for Dyn11 Transformer?

    • @baranitech
      @baranitech  4 ปีที่แล้ว

      Its depends on which application your going to use.

  • @jaynandan9937
    @jaynandan9937 4 ปีที่แล้ว

    Sir can I connect parallel of two transformer having vector group ynd11 or ynd1

  • @arifmehmud5677
    @arifmehmud5677 4 ปีที่แล้ว +1

    sir which software used for making this video????

  • @SunnySingh-ei3rp
    @SunnySingh-ei3rp 5 ปีที่แล้ว

    Sir thank u nice explanation.
    There's can be many transformer in between generator transformer and distribution system so how this phase matching helpless.

    • @rjshtk
      @rjshtk ปีที่แล้ว

      All those in between transformers will be YNyn0 type. So these will just carry forward whatever phase angle from the Generator Transformer side to the Distribution Transformer.

  • @surendrakverma555
    @surendrakverma555 4 ปีที่แล้ว +1

    Good

  • @sagarraj.trajtt9634
    @sagarraj.trajtt9634 4 ปีที่แล้ว +1

    Pls upload TTR test.....

    • @baranitech
      @baranitech  4 ปีที่แล้ว

      i will make soon

  • @akibkhan2274
    @akibkhan2274 ปีที่แล้ว

    why it is needed?

    • @baranitech
      @baranitech  ปีที่แล้ว

      yes taking lv side star and to avoid 3th harmonic on HV

  • @tugsmandalpurewdorj1815
    @tugsmandalpurewdorj1815 4 ปีที่แล้ว

    Thanks