Bro GT la Yd11 connect panna circulating current form aahatha Bcs Generator um NGT pottu earth panni irrupanga trafo oda primary star ah irruntha athum appo Earth aahum la
Anna ipo Yd11 transformer LV side-delta (generation side) HV side star (Grid side) Ipo phase shift akura voltage gird(HV) la connect Panna ethavathu affect aakuma.
Really hats off you sir doing best thank you keep do more videos
Sir...nice explanation ...thx for your valuable efforts...
14:00 is ultimately useful interview information
15:10 18:40 awesome THALA VATHI ROCKING 🙄🌎🌏🐸😲🙏
thank you
Hormonic explain panuga
Thanks for the Vedio
Most welcome
Hi brother Yd1 and Yd11 winding connections shown same can you please clarify this one.
connection same but value point different
@@baranitechtamil can you please explain
bro understandable teaching please explain three winding transformer vector group and calculation
okay bro soon i will make video for you
@@baranitechtamil thanks bro wait for your video
@@chandrannarayanan1072 this coming month i will post bro
Thanks for your response
Why connecting yd11 R polarity to B non polarity
Also please explain directional relay
th-cam.com/video/mWJnH4_0kas/w-d-xo.html
Good job bro pls upload lightning arrester,ct pt connections,transformer tappings,
okay bro
Bro GT la Yd11 connect panna circulating current form aahatha
Bcs Generator um NGT pottu earth panni irrupanga trafo oda primary star ah irruntha athum appo Earth aahum la
Without Resistance grounding will create circulating current. but when we have NGR or NGT then i make high imp & high resistance path for This earth.
@@baranitechtamil ohho seri na thx
Please explain the derivation
soon i will make
bro im having one doubt .. .can u explain
please tell me bro if i know i will explain
Dy0 ?
DY0 vector group not possible thank you
Hii bro I think as per IEC Standard primary is not denotes capital letter and as well as secondary.. If it's wrong please correct me.
Bro as per IEC standard HV is denotes Capital and LV is denotes small letter.
Bro Hv side ah dhane capital la mention pannuvanga
@@vishvaaram8279 yes bro
@@baranitechtamil bro ungaluku group yatha irrunthici na ennium add pannuga please my number 9445993929
@@vishvaaram8279 in future maybe we can have group bro . if i create then i will add you in that group
yd9 correcta bro?
correct
Anna ipo Yd11 transformer
LV side-delta (generation side)
HV side star (Grid side)
Ipo phase shift akura voltage gird(HV) la connect Panna ethavathu affect aakuma.
while doing Synchronizing it will catch the angle. so no problem.
Super anna
English please .. We are Africans
th-cam.com/video/-7BkRGIsc6w/w-d-xo.html