Just use a term alara, which means as low as reasonably achievable. So safe distance when testing, keep stored in the truck, close rod in the gauge before recording test results, don't open the case, use a mirror to check the shutter and when servicing
No that isn't true. The sources are 15mCi Cs137 and 40mCi of AmBe for density and moisture. Both sources are well shielded when the device is not in use and simply stepping back 10 feet or so while it does its thing gives negligible exposure to radiation. If you have concerns you can purchase an alarming dosimeter.
can you mention what radiation protective equipment is needed to work with toroxler gauging?
Just use a term alara, which means as low as reasonably achievable. So safe distance when testing, keep stored in the truck, close rod in the gauge before recording test results, don't open the case, use a mirror to check the shutter and when servicing
What is the radioactive source in these gauge?
cesium 137 for gammas (density) and americium-beryllium for neutrons (moisture content)
Is it true the gauge can cause infertility ?
No that isn't true. The sources are 15mCi Cs137 and 40mCi of AmBe for density and moisture. Both sources are well shielded when the device is not in use and simply stepping back 10 feet or so while it does its thing gives negligible exposure to radiation. If you have concerns you can purchase an alarming dosimeter.
that's is very done
#nucleargauges
Oath
could you mention what radiation protective equipment is needed to work with toroxler gauging?
None, just a dosimeter but even that isn’t necessarily needed. With proper alara technique there is literally no threat
A dosimeter, preferably the electronic alarming type. You won't get much exposure from these in normal operation. ❤