- Hello everyone I am electrical engineer Farhan Ali dilbar hope you are doing well.
Keep your INVT inverters and VFDs running smoothly with this maintenance plan recommended by the manufacturer! In this video, we'll cover daily, 3-month, and 6-month checklists to help you identify and fix potential issues before they become major problems. By following these simple steps, you'll minimize errors, reduce downtime, and extend the lifespan of your equipment. Watch now and keep your industrial operations running efficiently!"
In this video I have try to explain the maintenance setting which the INVT company recommended about the short and minimize the errors of your three phase INVT VFD or inverter. This maintenance plan is contains on daily basis and monthly basis. In this video you will learn with very detail on the daily basis what things need to check if you have installed the INVTt inverter and on the monthly basis what thing need to check and have you can save your inverter from different errors.
#INVTInverter
#InverterMaintenance
#VFDMaintenance
#IndustrialMaintenance
#PredictiveMaintenance
#PreventiveMaintenance
#ElectricianTips
#IndustrialAutomation
#MaintenanceChecklist
#ErrorMinimization
#IndustrialEfficiency
#EquipmentReliability
#InvtInverter #InverterTutorial #SinglePhase #ThreePhase #PowerConversion #ElectricalEngineering #ParameterSettings #EnergyEfficiency #GreenEnergy #RenewableEnergy #DIYElectronics #ElectricalAppliances #TechnologyGuide #HowTo #ElectricalExpertise #EnergyConversion #EnergyOptimization #ElectricalSystems #Electricity101 #ElectricityTutorial #InverterConnection #TechnologyExplained #EnergySavings #EnergyManagement #EnergyConversionTips #ElectricalSetup #ElectricityKnowledge #TechKnowhow#INVT #invt #maintenance #dailymaintenance #dailychecking #monthlychecking
Apki videos hamesha information wali hoti hain❤
Thanks for appreciate. Keep watching
Good information
Thanks
ماشاءاللہ آپ کی ہر وڈیو دیکھتا ہو سچائی پر مبنی اور سبق آموز ہوتی ہے میرا آپ سے ایک سوال ہے کہ میرے پاس 22پینل ہوں اور دو سٹرنگ بناؤں ایک میں 10 دوسری میں 12 پینل لگا دوں تو کوئی مسلئہ ہو گا یا نہیں ؟؟؟
AoA. Dear pannel kitny watt k hain. Or ap ky output voltage kitny hoon gy ? Invt ki maximum input range 800 voltage Dc hy. Ap is baat ka khayal rakhna hy. Aap k input voltage 750 ki range main hoon ye best hy.
سر دونوں سٹنگ کے وولٹیج اگر برابر نہ ہوں تو کام چل جائے گا
@@MuhammadRamzan-gs2zunhi
good work
Thanks
very informative
Glad you think so!
sir g ek video banao jis ma tubewell ki setting batain
Very soon. Thanks for your comment. Keep watching 👍
Nice work sir
Thanks 👍
Also check these two videos
th-cam.com/video/BxPUtpx4B8c/w-d-xo.htmlsi=bfBI2Kb7n0lVcnct
And this one
th-cam.com/video/gsf4rji1Dug/w-d-xo.htmlsi=hDvh5LFS0tGBJFEn
Zabardast info..
Thanks 👍
Good
Thanks 👍
Also check these two videos
th-cam.com/video/BxPUtpx4B8c/w-d-xo.htmlsi=bfBI2Kb7n0lVcnct
And this one
th-cam.com/video/gsf4rji1Dug/w-d-xo.htmlsi=hDvh5LFS0tGBJFEn
👍👍👍👍👍👍
Thanks 👍. Keep watching
Good morning sir k .p saxena fatehpur up
Have a good day
hay sar Rajab Ali mob charging invest par video bnao sar
Okay dear
Also check these two videos
th-cam.com/video/BxPUtpx4B8c/w-d-xo.htmlsi=bfBI2Kb7n0lVcnct
And this one
th-cam.com/video/gsf4rji1Dug/w-d-xo.htmlsi=hDvh5LFS0tGBJFEn
G❤❤❤
Thanks 👍
انویٹر نیا ھے اور ۔موٹڑ بھی نی ھے پھر بھی او ایچ گیارہ کا کود اجاتا ھے
Dear ap wahan ka temperature 🌡️ check karain. Motor ki rating check karain . Aap ny motor inverter ki capacity se jyada ki to Nahin lagai Hui. Aur FIR aap iske cooling fan ki setting ko P8 group mein jakar change kar sakte hain. K fan musalsal chalta Rahe. Isase bhi iska temperature down rahega aur inverter per yah error Nahin aaega. Cable ka size b load k hisab sy check karain.
OH1 ka bhai kod ajata hai 11bijy
Assalamu alaikum dear.
Dear aap sabse pahle to yah check Karen ki aapka mahaul ka temperature kitna hai. Aap iske cooling fan ki jo setting hai usko yani ke P8 dot 26 Jo parameter hai usmein jakar tabdil kar len ki aapka calling fan lagatar chalta Rahe FIR yah aapke inverter ke temperature ko maintain rakhega. Dusra aap yah check Karen ki aapki motor ki capacity kitni hai aur inverter ki capacity kitni hai ya aapane Jo cable istemal ki hai uska size load ke hisab se theek hai. Aur terminal vagaira ki losing bhi check kar le ya FIR aisa bhi ho sakta hai ki aapane inverter ko aisi jagah per lagaya ho Jahan per dhup pad rahi ho uska temperature badh Raha ho.
सर आप हिंदी तो बोलते हैं पर हिंदी समझ नहीं पाते हैं क्या
Not understand Hindi