How To Troubleshoot A Bad Control Board! Fan Wont Come On

แชร์
ฝัง
  • เผยแพร่เมื่อ 29 ส.ค. 2024
  • All my favorite HVAC tools: www.amazon.com...
    In this video we walk you through how to diagnose or troubleshoot a bad control board. This same technique applies for A/C as well if your fan isnt running, you'd jump R and Y instead of R and W. Then you'd check for voltage between the neutral pin and COOL instead of Heat. I hope you found this video informative! If so make sure and leave it a like and subscribe to our channel!
    IF YOU ARE IN NEED OF GUIDANCE WITH YOUR HVAC SYSTEM, whether it is diagnosing a bad part, replacing your system, or help with sizing, check out our membership program here: / diyhvacguy
    For a small monthly fee of $50, you will get assistance from myself when it comes to your hvac needs, whether it's sizing, diagnosing, or locating the correct equipment.
    ⚠️ Disclaimer:
    This video is for educational purposes. Any and all HVAC repair work is done at your own risk. The DIY HVAC Guy channel is not responsible for any possible damages or injuries caused by the use or misuse of the provided information.
    The DIY HVAC GUY is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com.

ความคิดเห็น • 120

  • @tensecondbuickgn
    @tensecondbuickgn 7 หลายเดือนก่อน +8

    As a retired ASE master automotive tech, these videos are fantastic to watch. Very clear and precise and dumbed down enough for the average Joe

    • @YouTube_T45K
      @YouTube_T45K 5 หลายเดือนก่อน

      My thoughts exactly

  • @Hxneybee395
    @Hxneybee395 3 หลายเดือนก่อน +2

    Had a customer short a board on an inverter system watching one of these videos. Keep cranking them out!

  • @henryayala9657
    @henryayala9657 8 หลายเดือนก่อน +3

    Thanks for all your videos. I had the same unit with the same problem. The root cause was a cold solder joint on a white terminal connector. This was caused by the weight of the wires and an unbalanced blower. Having the control board mounted to the blower housing is probably not the best design but the stock wires did not allow relocating for me.

  • @nvatlanticcity3
    @nvatlanticcity3 ปีที่แล้ว +6

    Great tip on testing the blower by connecting it to the transformer near the door. Thank you for your easy to follow video.

    • @diyhvacguy
      @diyhvacguy  ปีที่แล้ว

      Yea! Definitely using that truck next time I’m diagnosing a furnace with no blower!

    • @borshardsd
      @borshardsd 4 หลายเดือนก่อน

      Lolol was it the transformer or the DOOR SWITCH. who knows good luck ;)

  • @BeersHVAC
    @BeersHVAC 7 หลายเดือนก่อน +2

    Great tip on sending 120V directly to the blower speed tap! I will be using that one!

  • @bawipengcin8591
    @bawipengcin8591 10 หลายเดือนก่อน +2

    Thank you for the tips , Man. I was able to diagnose for Bad board by your knowledge sharing. Please keep up sharing you knowledge

    • @diyhvacguy
      @diyhvacguy  10 หลายเดือนก่อน

      Awesome . Glad to hear it

  • @andresbarragan8595
    @andresbarragan8595 8 หลายเดือนก่อน +2

    FROM CHICAGO IM YOUR #1 FOLOWING YOUR VIDEOS THANK YOU SO MUCH

  • @lego40404
    @lego40404 9 หลายเดือนก่อน

    I got a emergency service call this morning with identical issue on a Emerson, only difference was I had zero volts at heat stake on tab. I know those black box relays on the boards can stick as they get older so I did the tapping on them to see if I can free them up for now till I get a replacement. Nope. Being the weekend and the burbs of Buffalo, I needed a work around, hmm. My board has a tab just for constant fan run, (like you would set your thermostat to fan always on and circulating the air)that let me run unit without it tripping on thermal overload. It’s a temp fix so heat does operate properly and furnace shuts off when setpoint is met. Love your videos. I can’t remember if your the guy who did the video on the kiawets dmm amprobe but I’m glad I picked one up

  • @jaykeller1
    @jaykeller1 10 หลายเดือนก่อน +1

    great quick test for jumping out the blower thank you sir!

  • @ReverendRichie
    @ReverendRichie 8 หลายเดือนก่อน

    Thank you for your excellent videos; the above video makes total sense and is the source of my problem. Interestingly, the blower motor comes on when a call for FAN or Cooling is received but not for a Call for heat. It APPEARS that the call for heat and the call for the FAN to energize are two separate circuits. I ASSUME is for the blower to run at a lower rate during the demand for heat. I need to verify this, but it is the only thing that makes sense. Thanks for the simple motor test; that should help me immensely.

  • @JP-mk3bb
    @JP-mk3bb 8 หลายเดือนก่อน +1

    @The DIY HVAC Guy, firstly thank you for taking the time to film such clear and professional videos. I'm having this exact issue after following the instructions it seems as though my control board is bad. I have a lennox 80mgf3 60a-12 and have a surelight model # 50A62-121 control board. I've found one that says it's compatible but it's model # 50A66-123-01. Can you please let me know if that would work with my unit? Any help would be greatly appreciated. Thanks again!

  • @chrisgreen177
    @chrisgreen177 ปีที่แล้ว +6

    I'm an electronics troubleshooter and repairer by training. I was told that the control board was bad on my parents furnace and had to be replaced by a local HVAC service company. It was winter here in Wisconsin, so I paid $2700 to have the board replaced, because I didn't know how long it would take me to get around to troubleshooting the "bad board", replacing components and repairing it, but, I did request to keep the bad board after they replace it with new one. I was told that they did not leave bad components with the customer, and would not let me keep it. That made me very suspicious. For all I know, it could have been something as minor as a series of resistors, a relay, a capacitors, a cold solder joint, or some other components that very rudimentary board had that was degraded, shorted or open. I just found that very suspect, especially with him trying to charge $290 to replace a flame sensor that was only reading .30 ohms out of the +/- window tolerance. He didn't even offer to clean it for me.

    • @diyhvacguy
      @diyhvacguy  ปีที่แล้ว +5

      Sounds like you need to find a small family owned hvac business that’s trustworthy!

    • @hafeezurrahman1000
      @hafeezurrahman1000 ปีที่แล้ว +1

      Thanks for sharing your story.

    • @Nine_883
      @Nine_883 ปีที่แล้ว +4

      People do not generally repair these board, but if you have the skills then by al means. The being said a typical universal board will run the contractor between $100-$200 and takes less than an hour to replace. Maybe even 20 minutes depending on the board and accessibility. So even if he did it on Christmas Night Holiday rates and it took an hour he got you for at least $2000. The boards are pretty much plug and play with a few minor modifications (such as cutting jumpers) on a Universal type. That guy should be in prison.

    • @chrisgreen177
      @chrisgreen177 ปีที่แล้ว +1

      @@Nine_883 I was pretty disgusted with the cost. They have people at their mercy, especially during the winter. All this was after he tried every sales pitch in the book to get me to finance a replacement 90% efficiency furnace installed for $5800.

    • @ajahijernigan4051
      @ajahijernigan4051 ปีที่แล้ว

      @@Nine_883 agreed I don’t know anyone who repairs but that’s a lot of money but I will say due to circumstances idk how much they had to pay a guy to leave his family to do this

  • @marcosylvia5704
    @marcosylvia5704 ปีที่แล้ว +3

    Awesome video. You make it look so easy. Thank you.

  • @fernandofrancisco3106
    @fernandofrancisco3106 17 วันที่ผ่านมา

    Great video very informative thank you

  • @paull2089
    @paull2089 ปีที่แล้ว

    Thanks for showing us your trouble shooting skills

  • @ohiopat
    @ohiopat ปีที่แล้ว +6

    I bet if you pulled the yellow wire half off so that you could read the voltage with it hooked up it would have been 0. There are a lot of transient "ghost" voltages on circuit boards due to the nature of electronics.

    • @diyhvacguy
      @diyhvacguy  ปีที่แล้ว +2

      I did that and it still said 115. I didn’t show it but I replaced the blower motor because of that. Only to find that it did the same problem. The board was the fix for this one. That video comes out in a few days.

  • @billmcmaster7909
    @billmcmaster7909 6 หลายเดือนก่อน

    Some good information that I'll use down the road.

  • @byronsinclair3956
    @byronsinclair3956 หลายเดือนก่อน

    Great videos. I’m watching as much as I can. Gonna try and tackle new heat pump upgrade after watching many of your videos. Just trying to get through the summer heat before attempting it this fall.
    I know this pertains to the furnace/heat but could the same procedure/test be done to verify if the board bad if the blower motor unexpectedly cuts off/wont start when thermostat is calling for cooling? Basically instead of testing the heat pin (yellow/heat) and neutral, could you do the same voltage check for the cooling pin and neutral?
    The capacitor and blower motor are new (wish I had found this video a couple days ago). Freon flows, no obstructions/new filter, compressor functions. Fan stops less than a minute after stat calls for cooling. I’m wondering if it’s a faulty board and if this would be a good way to determine that.

  • @gotchaplumber
    @gotchaplumber 16 วันที่ผ่านมา

    Great tip!

  • @georgekern6528
    @georgekern6528 ปีที่แล้ว +2

    Great video! Well done! Cheers! George

  • @1255You
    @1255You ปีที่แล้ว +1

    Hey HVAC Guy, you have really excellent videos & I've learned a lot watching them. This is off topic for this particular video but I was hoping you could do a video on identifying the proper capacitor to use on the condenser side of the system. The original on mine has no identifiable markings I can use to obtain a replacement due to corrosion on it. Or perhaps you can just push me in the right direction to a video you may have already done on this issue. Many thanks in advance.

    • @diyhvacguy
      @diyhvacguy  ปีที่แล้ว

      Great idea! Until I make that video, if you’re trying to find the right capacitor right now, you can punch in the actual condenser model or serial number in repairclinic.com and it will give you a parts list for that particular unit. Or if your capacitor is still good and your system is running, you can use a multi meter to check the existing one, and then purchase a replacement. Hope this help! Cheers

  • @adolfovazquez8427
    @adolfovazquez8427 ปีที่แล้ว +1

    Great video thanks for sharing you are the best another tip for my book

  • @Jaylenn.
    @Jaylenn. 6 หลายเดือนก่อน +4

    Couldn’t you just jumper R and G to trouble shoot it ?

    • @jollyscaria1922
      @jollyscaria1922 24 วันที่ผ่านมา

      Pcb bord power checking trsding trsformd low volt rc rg comon cool and checking r using strge comrinv anx checking ry 24v rg ond ny fsn low high meom oin power met checkinvg

  • @binnsbrian
    @binnsbrian ปีที่แล้ว +1

    Great information. One problem i find is I went to a heating and air conditioning supply and they wouldn't sell me parts because I didn't has a licence.

    • @diyhvacguy
      @diyhvacguy  ปีที่แล้ว +4

      Yes that is a very common problem. A lot of times the parts can be found at repairclinic.com but you’ll have to wait a few days. Next time, send me a message at diyhvacguy@gmail.com and I’ll see if I can call in a part and you can go pick it up 🤘🏼

    • @binnsbrian
      @binnsbrian ปีที่แล้ว

      @@diyhvacguy Thanks

  • @mauriciomachado5227
    @mauriciomachado5227 7 หลายเดือนก่อน

    Great video and I learn a lot from them, so thank you. When the Red LED is blinking on the control board, does that mean the board is bad or does it blink all the time?

    • @WildChildRecovery
      @WildChildRecovery 3 หลายเดือนก่อน

      Some boards will have a blink pattern to specify a fault code. Usually the patterns are labeled on the cover or in a manual.

  • @user-gd5bn2qp2c
    @user-gd5bn2qp2c ปีที่แล้ว +2

    Really like the trick to test the fan motor from the switch! Has the problem been solved after the board was replaced? And have you got a chance to test the voltage from the switch? I wondered it was 120 or 115?

    • @diyhvacguy
      @diyhvacguy  ปีที่แล้ว +1

      Yes the main power wire off the switch comes right from the transformer. So it had 122 as well. And yes the board fixed it. That board replacement video comes out tomorrow I believe. Showing how to physically replace the board 👍🏼 cheers

  • @aftrwhlcrocs
    @aftrwhlcrocs 6 วันที่ผ่านมา

    Thanks!

  • @Nine_883
    @Nine_883 ปีที่แล้ว +3

    I would just jumper 120v to that motor to run 24/7 until I could get a board so the customer doesn’t freeze. Depends what day it is and what time of day it is. Running it all of the time won’t hurt. Run it through a relay so high speed kicks out low speed. Whatever it takes.

    • @diyhvacguy
      @diyhvacguy  ปีที่แล้ว +1

      Yea I asked them if they wanted me to do that but it didn’t get cold that night so they said just leave it off. Thanks for the tip though! Maybe it will help someone else on here :)

    • @Nine_883
      @Nine_883 ปีที่แล้ว

      @@diyhvacguy Yeah for anyone who might be interested. Back in the day when we had the bimetal fan switch and a fan relay we jumped that low speed fan switch out all of the time. Let it run 24/7 and it actually would keep the house at a more even temperature and it would prevent it from short cycling. When the AC or "fan switch" was turned on the relay would kick out the low speed so there was never both windings energized at the same time. I even ran my own house like that and and the temperature was a lot more consistent. When PCB's took over the controls you saw that less and less because then you would have to add a relay to make it work. A lot of people prefer that low speed fan running all of the time. The fan only costs pennies a day to run (or at least it used to be pennies). This was very common practice back in the days before disco! 🤣😜

  • @petersmart1999
    @petersmart1999 ปีที่แล้ว +4

    The voltage drop from the board is insignifigant,its plus or minus 10% 122 incoming to trans,an 115 out of board is not a problem. A bad fan relay on the board would be!

    • @diyhvacguy
      @diyhvacguy  ปีที่แล้ว

      The fan solenoid is before the heat pin for the fan, so how would the solenoid effect this if I’m getting 115 as soon as I hear the solenoid click?

    • @petersmart1999
      @petersmart1999 ปีที่แล้ว

      @@diyhvacguy voltage is voltage,it can be present without current flow!

  • @siroossoleimanian4813
    @siroossoleimanian4813 10 หลายเดือนก่อน

    Thank for very good explanation and troubleshooting.
    Could you please explain TWIN terminal which no wire connected to?
    Also what is the replacement card for 4633e Emerson card for Amana furnace?
    Thanks.

  • @globalkonnect2059
    @globalkonnect2059 2 หลายเดือนก่อน

    Cheat code thankyou

  • @zoubirgaoua7521
    @zoubirgaoua7521 9 หลายเดือนก่อน

    Another great trick. Thanks

  • @leelemon3373
    @leelemon3373 7 หลายเดือนก่อน

    As always 5 Stars 😎

  • @jimbarron8688
    @jimbarron8688 8 หลายเดือนก่อน

    Remove black wire from cooling speed terminal. Replace with yellow wire for heat speed. Select fan on at thermostat and call for heat. Fan will run continuously but heat will be on. Replace board... likely cause is pitted relay contacts in fan relay.

  • @anhpham8199
    @anhpham8199 20 วันที่ผ่านมา

    My blower motor won't start, but my unit is run by EMC Module. Can you help me fix it? Thanks so much.

  • @6ecortes
    @6ecortes 9 หลายเดือนก่อน

    Great video. I have a Trane furnace that shuts off because the blower keeps shutting off. I found that by pressing on the control board the blower will kick in and I will have heat again until the process begins all over again. Do you have any idea why? New sub here.

  • @giantkillin8278
    @giantkillin8278 ปีที่แล้ว

    adding to my knowledge bank.@ thanks

  • @GotchaplumberGotchahvac
    @GotchaplumberGotchahvac 9 หลายเดือนก่อน

    Question: When jumpering R & W, will the board allow the blower motor to come on without jumpering R/W/G?

  • @sonle-fz1xb
    @sonle-fz1xb ปีที่แล้ว

    Great video! Thank you so much.

  • @thomasmarshall7795
    @thomasmarshall7795 9 หลายเดือนก่อน

    Dave,replaced contractor in my Amana heat pump I thought all wires were replaced however I found 1 red wire that comes from defrost board marked cnt where on the contractor does it go? Thank you very much

  • @terrellherrin1661
    @terrellherrin1661 7 หลายเดือนก่อน

    So if all the wires to the thermostat have power, (24 vdc) the control board is bad?

  • @anhpham8199
    @anhpham8199 13 วันที่ผ่านมา

    My blower motor stopped working after a few days of running. It will start working again after I let it rest for a couple days. I suppose blower motor was over heat. How can I fix it? Please help.

  • @bachphi1
    @bachphi1 7 หลายเดือนก่อน

    One of the relays is bad, its contact did not switch . If you pull out the blue and/or red, I think it will run.

  • @Heyim18bro
    @Heyim18bro 11 หลายเดือนก่อน

    1:39 I think I added the jumpers while it was on and it blew out the blade fuse. Did that happen because it was on or is that an indication of something else?

  • @Randylazz
    @Randylazz ปีที่แล้ว

    Pretty Cool Tech Tips………..

  • @GotchaplumberGotchahvac
    @GotchaplumberGotchahvac 9 หลายเดือนก่อน

    Enjoy video.

  • @cutum
    @cutum ปีที่แล้ว +2

    Crazy. You'd think 115 would fire up the motor

    • @diyhvacguy
      @diyhvacguy  ปีที่แล้ว +1

      I know right, I was stumped by this one. But my buddy learned me the safety switch truck 😎

  • @eddieochoa6636
    @eddieochoa6636 ปีที่แล้ว

    Great video

  • @LukeWarmwater-yb5lx
    @LukeWarmwater-yb5lx ปีที่แล้ว

    Thank You.

  • @vernardking8067
    @vernardking8067 12 วันที่ผ่านมา

    My control board light is out and my unit not coming on my transformer isn’t getting any power

  • @renecuevas4128
    @renecuevas4128 7 หลายเดือนก่อน

    Is there a misspelling on the price? Ridiculous i would get a 2nd opinion and pay a svc call....most is 300 for board and 185 install for a rep co. With a warranty 1 yr parts and labor and if u want old part i leave it on top of AC if part do not resolve the issue No charge for part only svc call but most our customers have contract so they only pay for parts not under cont.. about 100 bucks This ia my co in my state....lowest temp here now 56

  • @stanleykania7184
    @stanleykania7184 ปีที่แล้ว

    Nice !! Thank you

  • @josephferguson3423
    @josephferguson3423 ปีที่แล้ว

    Excellent

  • @zurdohtown
    @zurdohtown หลายเดือนก่อน

    What happens if blower fan don’t stop

  • @Discovery123.
    @Discovery123. ปีที่แล้ว

    Question boss, did you go thru this career by apprenticeship program? I really like your video. Thanks!

    • @diyhvacguy
      @diyhvacguy  ปีที่แล้ว +2

      I learned most of what I know working with a friend of mine who had an hvac business back in Tennessee. Everything else has been self taught with the help of the Anti Diy Hvac channel as well as AC Service Tech! I did the 25 hr course to get your contractors license here in utah and took the test and that was it! Utah is really easy to get your license.

    • @Discovery123.
      @Discovery123. ปีที่แล้ว

      @@diyhvacguy Thank you Master!

  • @planetvance
    @planetvance ปีที่แล้ว

    What do you think of AirQuest vs. Goodman? HVAC Direct wants to substitute AirQuest for my Goodman order. Should I say OK?

    • @diyhvacguy
      @diyhvacguy  ปีที่แล้ว

      Yea Airquest is an offshoot of Carrier equipment. It’s a good brand and the same 10 year warranty can be had with Airquest.
      If you need some help with your replacement, check out our Patreon membership over at Patreon.com/diyhvacguy where for $50 I will give you one on one assistance with replacements, diagnosing, and even help with getting the full 10 year warranty on your equipment. Cheers

  • @donhgr
    @donhgr ปีที่แล้ว +2

    I been fooled by that before and you can see 115 mv and think it was volts and you really don’t have any, look closely at your meter when you see that because a lot of times it would run on 115 volts.

    • @diyhvacguy
      @diyhvacguy  ปีที่แล้ว

      What do you mean look closely?

    • @donhgr
      @donhgr ปีที่แล้ว

      @@diyhvacguy I missed it saying mv instead of volts and added 30 min to troubleshooting thinking I had AC,

  • @elkess1
    @elkess1 9 หลายเดือนก่อน

    How do you touch the yellow wire to the door switch while power is ON?

    • @diyhvacguy
      @diyhvacguy  9 หลายเดือนก่อน

      Pull one lead off the door switch on the back and touch yellow to it while closing the door switch

  • @derrtydungeon
    @derrtydungeon หลายเดือนก่อน

    Zip screw🙏🏿👍🏿👍🏿

  • @paulshlasko3608
    @paulshlasko3608 ปีที่แล้ว

    I don't think it was the 115 volts that was insufficient, I think it was lack of amperes.

    • @diyhvacguy
      @diyhvacguy  ปีที่แล้ว

      Interesting. Well the new board fixed it. I just wish I would have tried the fan motor to the safety switch trick before replacing the motor only to find out it was fine! Smh

    • @paulshlasko3608
      @paulshlasko3608 ปีที่แล้ว +1

      @@diyhvacguy You did it right, I am just mentioning things I have stumbled over. The test meters read a voltage that sometimes has no real meaning because negligible amperage will make it through when an actual load is applied. I think if you read the voltage with the load applied, it would drop to zero. Conversely, I have made another mistake when I tried to test an electronic low voltage transformer. It read no output, but if you put a bulb to it the bulb would light and you could read the volts and amps. Its just a thing that happens when you test an electronic device with another. Its just my experience; I have no formal training.

  • @vasileiosbakas9754
    @vasileiosbakas9754 ปีที่แล้ว

    I m confused, the heating speed sends 115 v and motor not running and after you send 115v and kicks on, how is this possible?

    • @FranciscoPerez-th2hw
      @FranciscoPerez-th2hw ปีที่แล้ว

      When he applied 122 from the door switch it turned on

    • @vasileiosbakas9754
      @vasileiosbakas9754 ปีที่แล้ว +1

      @@FranciscoPerez-th2hw 122 and 115 no difference

    • @diyhvacguy
      @diyhvacguy  ปีที่แล้ว

      Yea that’s what I thought, but there is a different. That was the point of this video. I learned a valuable lesson in testing the fan with the safety switch, that rules out the blower motor or capacitor being bad.

    • @diyhvacguy
      @diyhvacguy  ปีที่แล้ว +2

      I didn’t do the safety switch fan test the first time I diagnosed this, I just checked the board, saw 115v and went to the supply house and got a new blower motor. It was after I put a new one in and had the same problem that I knew it was the board. But had I done the safety switch test first I wouldn’t have had to do it twice!

    • @vasileiosbakas9754
      @vasileiosbakas9754 ปีที่แล้ว +1

      @@diyhvacguy Have never seen this before, i d say it s a bad neutral but the neutral of the blower goes back to the board and it was checked ok.
      Glad you got it fixed still seems weird to me

  • @takeiteasymac3206
    @takeiteasymac3206 9 หลายเดือนก่อน +2

    That filter is gross

    • @denisvigil1538
      @denisvigil1538 9 หลายเดือนก่อน

      😂 idiot they are made that way

  • @jesiscott6048
    @jesiscott6048 7 หลายเดือนก่อน

    Actually, your blower is not getting enough current. We know the control board's relay (for the yellow wire) is being turned on since you measured 115 VAC, so the relay contacts must be damaged! Just trying to send you my electrical knowledge in return for your great videos.

    • @diyhvacguy
      @diyhvacguy  7 หลายเดือนก่อน

      Interesting!! Thank you sir

    • @jesiscott6048
      @jesiscott6048 7 หลายเดือนก่อน

      I'm female, but it's all good! Very cool how your video shows how there can be the expected voltage but far too little current(amps) to run a motor.

    • @bachphi1
      @bachphi1 7 หลายเดือนก่อน

      The reason it did not get enough current because one of the other 'bad' relays. Pull out the red and or blue wire.

  • @jollyscaria1922
    @jollyscaria1922 24 วันที่ผ่านมา

    Bad bored ok damge power burinv ok replcing ssme modrls power high low voltges checking

  • @HoodHandyman
    @HoodHandyman ปีที่แล้ว

    Im still not sure its the board.

    • @diyhvacguy
      @diyhvacguy  ปีที่แล้ว

      It was, the follow up video that hasn’t posted yet shows how to replace the board and that was indeed what was wrong. Bizarre right? I put a blower motor in because I didn’t think to jump it from the hot wire at the safety switch until a friend of mine told me about that. After putting the new blower motor in, same thing. Sometimes ya gotta do things twice I guess! Cheers man

    • @diyhvacguy
      @diyhvacguy  ปีที่แล้ว +2

      You’d think 115v would be sufficient but it wasn’t

    • @HoodHandyman
      @HoodHandyman ปีที่แล้ว +1

      @@diyhvacguy I'm no major expert nor do i pretend to be but I would check the continuity on the wire before changing the board I am epa certified and have a diploma in HVAC :)

    • @MrConcord75
      @MrConcord75 ปีที่แล้ว +1

      @@diyhvacguy you’re correct. If the main voltage is 122 and you’re seeing 115 at the relay it’s a sign of voltage drop. I bet if you measured the voltage at the motor connector with the motor plugged in when triggered it would be even lower or zero because of the load.

    • @vasileiosbakas9754
      @vasileiosbakas9754 ปีที่แล้ว +1

      @@HoodHandyman agree with you 100%

  • @ericwilliams702
    @ericwilliams702 ปีที่แล้ว

    That filter is bad

    • @petersmart1999
      @petersmart1999 ปีที่แล้ว +1

      No,im sure its a carbon impregnated special order filter! Bahahaha

    • @diyhvacguy
      @diyhvacguy  ปีที่แล้ว +1

      You are correct. Carbon filter. They are good about keeping the filter changed, as crappy as the unit itself looks haha

  • @alfonsobenitez8574
    @alfonsobenitez8574 10 หลายเดือนก่อน +1

    The heat relay in the board is bad. Replace the board.