    Hello guys good day
    Merun n nmn akong video na nagpapaliwanag sa isang dahilan na maaring makatulong bakit nag hign ampere ang compressor kahit bagong palit... at me kunting paliwanag na rin po sayu about ulit sa loose compression.... at bukod dun me kunting idea na rin po sa inverter compressor kung bakit hindi sia pwede irekta sa 220V. At pagpapalinawag na rin sa C S R. Baka po malito yung iba sa sinabi kong alin ang mababa yun ang common at pinakamataas ang start.. sa baguhan po dun sa 3 pin na sinasabi ko is alin pinakamababang reading mo sa 3 pin(common) na sinukat mo. At ang alin ang mas pinaka mataas na nasukat mo sa 3pin(start)... at automatic yung natira is running
    Muli maraming salamat sa viewer at comment..
    Pa subscribe like and share ng ating video.
    God bless

ความคิดเห็น • 403

  • @manuellazam2605
    @manuellazam2605 3 หลายเดือนก่อน +1

    salamat sa tutorial kabayan.

  • @danilomaynite3606
    @danilomaynite3606 ปีที่แล้ว +1

    HVAC po ako d2 sa oman Salamat sir at may natutunan ako...

  • @alfreddelmundo9309
    @alfreddelmundo9309 9 หลายเดือนก่อน +1

    Good advice sir👍👍👍👍

  • @ramongarciano1738
    @ramongarciano1738 ปีที่แล้ว +1

    Sir, I like your attitude. I wish all technicians would be like you, honest and helpful. Mabibilang na lang ang katulad mo. Good luck, sir, and I wish you the best!

  • @gilbertlazaro9787
    @gilbertlazaro9787 2 หลายเดือนก่อน +1

    Salamat master

  • @douglascatampo8357
    @douglascatampo8357 2 หลายเดือนก่อน +1

    Maraming salamat sir

  • @reynoldvenuszambrano2481
    @reynoldvenuszambrano2481 3 ปีที่แล้ว +4

    Nice video po sir malinaw na malinaw ang turo nyo,more power...stay safe po sa abroad...god blessed

    • @marlonvillafuerte8347
      @marlonvillafuerte8347 3 ปีที่แล้ว

      gud pm po.sir,bago ko lang po kayo natagpuan dito sa youtube channel n'yo.at lahat po ng videos ninyo accurate po ang inyong mga turo.salamat po ng marami sa inyo sir💕sir,may tanong po ako.ang 2 unit po namin na ref ay puro inverter.ang brand po ay whirlpool.parehas na pong sira.'yong dito sa canteen namin natest ko na po ang compressor.grounded po.'yong sa house po namin.kasisira lang po noong isang araw.ang problema po,ayaw umandar ng compressor.pero 'yong ilaw sa loob at blower gumagana naman po.natest ko 'yong compressor ok naman po kasi pare-parehas ang reading ng terminal ng compressor.ano po ba dahilan bakit hindi umaandar ang compressor? 1995 po ako naggraduate sa Meralco foundation.Quiapo branch.hindi ko po kasi kabisado ang power board ng inverter ref.dahil hindi naman namin napag-aralan ang inverter ref and aircon.maraming-maraming dalamat po sa inyo.

  • @loretojr.martizano3663
    @loretojr.martizano3663 2 ปีที่แล้ว +1

    Ganda ng paliwanag mo sir, newby po ako

  • @patricioagustin7660
    @patricioagustin7660 ปีที่แล้ว +1

    Perfect explanation thank you very much

  • @PauloDigo6
    @PauloDigo6 3 ปีที่แล้ว +1

    thanks sir..hndi k madamot na tao..may natutunan ako..

  • @kutkuterongutoy4814
    @kutkuterongutoy4814 3 ปีที่แล้ว +1

    My puso k sir godbless po

  • @richardcalimlim6805
    @richardcalimlim6805 ปีที่แล้ว +1

    goodwork po bossing

  • @glynb.5592
    @glynb.5592 ปีที่แล้ว +1

    matutu ako nito sir salamat

  • @FrancoFishing
    @FrancoFishing 2 ปีที่แล้ว +2

    Salamat master ..ang laking tulong ng Vlog mo po.. naayus ko na rin yung ginagawa ko 3 beses kong binabalikbalikan.. nag hi. amp sya.

    • @FrancoFishing
      @FrancoFishing 2 ปีที่แล้ว

      Ngayun chineck ko yung Flare type na Drier barado pala.. puro na tubig.. ngayun pinalitan ko na at bago na rin Refrigerant. OK NA PO SYA..SALAMAT NG MARAMI PO😍

    • @FrancoFishing
      @FrancoFishing 2 ปีที่แล้ว

      Ngayun chineck ko yung Flare type na Drier barado pala.. puro na tubig.. ngayun pinalitan ko na at bago na rin Refrigerant. OK NA PO SYA..SALAMAT NG MARAMI PO😍

  • @robertocumbe1920
    @robertocumbe1920 4 ปีที่แล้ว +1

    Alam na alam mo mabuting tao at di madamot sa kaalaman sana dumami pa kagaya nio sir

  • @rolandomartinianojr3669
    @rolandomartinianojr3669 3 ปีที่แล้ว +1

    Kuya tnx sa explenasyon ... ang lupit sa dmi ng napanood ko sa inyo klng po nalinawan n mabuti skt ng compresor,

  • @eduardopadoga
    @eduardopadoga 2 ปีที่แล้ว +1

    tnk. sir sa mga paliwanag mo sir.

  • @marcosespinosa7889
    @marcosespinosa7889 3 ปีที่แล้ว +1

    Maganda yan marami kang natutulongan

    • @jhayjaybuena8162
      @jhayjaybuena8162 3 ปีที่แล้ว

      Ano ang sira ng ref ang bba ng ampere completo na man ang preon.

  • @markjosephmatol294
    @markjosephmatol294 2 ปีที่แล้ว +1

    salamat master sa kaalaman

  • @thorenciso5964
    @thorenciso5964 3 ปีที่แล้ว +1

    Salamat master Tama po kayo tulongan dapat stay safe po lage dyan

  • @alexdelacruz8236
    @alexdelacruz8236 3 ปีที่แล้ว +1

    Sir thanks po nasagot sa dto vlog nyo ang tanong ng problema ko.God bless po & more power...

  • @williamconcepcion5483
    @williamconcepcion5483 3 ปีที่แล้ว

    salamat sir at malinaw ang paliwanag nyo at hindi kayo madamot s mga dagdag kaalaman.

  • @junolea9966
    @junolea9966 3 ปีที่แล้ว

    Boss salamat sa magandang mga skilled na share mo.Mabuhay ka

  • @shainasvlog316
    @shainasvlog316 3 ปีที่แล้ว +1

    Thank you boss,clear explanation...

  • @reybautista5970
    @reybautista5970 3 ปีที่แล้ว

    Sir maraming salamat sa pagbahagi ng iyong kaalaman may natutunan na nman ako God Bless at ingat po kayo dyqn sa abroad

  • @robertocumbe1920
    @robertocumbe1920 4 ปีที่แล้ว +1

    Sir maraming salamat sana marami pa kasunod na video, more power sau😄

  • @mateodelarosa1981
    @mateodelarosa1981 3 ปีที่แล้ว +1

    Grabe sana lahat ng Tech katulad niyo Sir. Nakailang pa check na ako ng ref ko puro na lang check iba iba ng diagnosis may curable and merong di terminal na ang hatol may nag pabili ng piyesa di naman na pala babalik at makokontak puro agency pa yon...😔😔😔

  • @triplexxxtv1868
    @triplexxxtv1868 2 ปีที่แล้ว +1

    Salamat master nagawa Kona ref filter pinalitan ko ok napo. Salamat

  • @wesavetosharetv7326
    @wesavetosharetv7326 3 ปีที่แล้ว +1

    God bless po and More Power!🙂🙂🙂

  • @alexsup5237
    @alexsup5237 3 ปีที่แล้ว

    Galing master naiintindihan ko na maliwanag na sa akin salamat malaking tulong huwag kang mag sawang tumulong sa freon.

  • @redtexmaniaa3504
    @redtexmaniaa3504 3 ปีที่แล้ว +1

    salamat sir sa vlog mo.nasagot na ang problema ko sa ac

  • @amorantoedangal5190
    @amorantoedangal5190 3 ปีที่แล้ว +1

    Ser...tama kpo...idol na kita ser...galing mopo

  • @leomardelator7966
    @leomardelator7966 ปีที่แล้ว +1

    Nakakamis din ganitong mga vlog mo boss,kaso ngayon nasa australia kna medyo nag iba na!

    • @MrGerbee2
      @MrGerbee2  ปีที่แล้ว

      Yes boss kakaiba busy dito hindi ka pagod pero sa ngayun sinusulit ko Panamanian at kung anu anu pa si ce para akong nakulong sa africa

  • @realheart0078
    @realheart0078 2 ปีที่แล้ว

    tama po..bawat blink me value yan kng anu ang error. kaya need nang kodigo!hahahahha..

  • @bongescora572
    @bongescora572 3 ปีที่แล้ว +1

    Thanks 4 great info bro!

  • @juanitoredondo8698
    @juanitoredondo8698 3 ปีที่แล้ว +1

    Thanks Gerbee god bless..

  • @labvlog26
    @labvlog26 3 ปีที่แล้ว

    Thanks. More knowlege po samin. Salamat

  • @ronalduy8529
    @ronalduy8529 3 ปีที่แล้ว

    Nice attitude sir. 👍

  • @ERLIN_BHONG
    @ERLIN_BHONG 3 ปีที่แล้ว

    Nice sir I salute u

  • @arisbaliton5291
    @arisbaliton5291 3 ปีที่แล้ว

    Nice one idol. Maliwanag ang explanation mo

  • @clemencitoperez5089
    @clemencitoperez5089 2 ปีที่แล้ว

    Very nice videos nio po. marami po akong natutunan. As amateur tech. May tanong lang po ako.

  • @Randztechenginering6573
    @Randztechenginering6573 ปีที่แล้ว

    Salamt idol

  • @allanluna5711
    @allanluna5711 3 ปีที่แล้ว +1

    Thank you sir ,simple at claro paliwanag nyo. Looking forward on your tutorials.

  • @williamcababat5007
    @williamcababat5007 3 ปีที่แล้ว

    Salamat sir sa Yung kaalaman n naibahagi mo

  • @restyjungay7781
    @restyjungay7781 4 ปีที่แล้ว

    ayos sir 😊😊 more videos sa ganitong truoble salamat sa idea

  • @janitolangcamon7911
    @janitolangcamon7911 3 ปีที่แล้ว

    Ok sir thank you sa vedio keep safe din dyan sa ibang bansa

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Thank you boss

  • @raymartbroncano8281
    @raymartbroncano8281 4 ปีที่แล้ว

    Salamat sa kaalaman sir..Ingat din jan

  • @donhatsrac7463
    @donhatsrac7463 4 ปีที่แล้ว

    Nice vedio and advise boss

  • @carloscaron5230
    @carloscaron5230 3 ปีที่แล้ว

    Salamat Sir sa info.

  • @reynaldoguimbaolibot2521
    @reynaldoguimbaolibot2521 3 ปีที่แล้ว

    Salamat....boss sa tips

  • @jerwinvarias4375
    @jerwinvarias4375 2 ปีที่แล้ว +1

    more power 2 u idol... tanung lang poh pag ba2 taas ang amp... tas grounded ang plug ano poh kaya sira nun... masagot nyo poh sana para dag2 kaalaman...

    • @MrGerbee2
      @MrGerbee2  2 ปีที่แล้ว

      Pag taas baba amp sa ac or ref bnagbabara sia. Pag grounded sira na rin malimit mag trip na rin yan sa mga bagong breaker

    • @jerwinvarias4375
      @jerwinvarias4375 2 ปีที่แล้ว +1

      @@MrGerbee2 maraming salamat poh... more video sana para marami p pong matulungan...

  • @renetalip7059
    @renetalip7059 3 ปีที่แล้ว

    Salamat sa info boss

  • @isidroflorendo8971
    @isidroflorendo8971 2 ปีที่แล้ว

    Sir galing nyo sir God bless po

  • @ericgarces2852
    @ericgarces2852 3 ปีที่แล้ว +1

    sir tanung kulang anung problem bakit namamatay ang refrigerator compressor,at nag high ampere,,ok naman po ang relay at overload...rated current 0.7,actual nya ay 5.5 Ampere na.

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Boss masyado na mataas 5.5 sa isang ref compressors baka sira na sia..pero try mo palitan capasitor or if mahugot mo sa tube connection paandarin mo sia mag isa pag nag normal ok pa pag hindi wala na pero sa 5.5 baka stock up na yan...

  • @dagohoyplz2675
    @dagohoyplz2675 2 ปีที่แล้ว +1

    Sir puede pa bang paandarin and isang stacked up na compressor

    • @MrGerbee2
      @MrGerbee2  2 ปีที่แล้ว

      Depende bos sa pagkkasira. Iba pwede pa iba tyga buksan lalo sa mg nag aaral pa lang

  • @ninocuerdo338
    @ninocuerdo338 3 หลายเดือนก่อน +1

    Sir Bago ref ko Panasonic di inverter .. 2 weeks ko palang magamit ..tapos nun 1 linggo na ..nag block block kuryente nag block out na diko natanggal na saksakan ..nun sinasaksak Kona gumana naman maya maya nawala na dina Siya umiinit at dina din gumagana metro namen

    • @MrGerbee2
      @MrGerbee2  3 หลายเดือนก่อน

      Pati metro? Metro ng kuryente? Bak shorted po yan

  • @junirtgalindez1745
    @junirtgalindez1745 ปีที่แล้ว +1

    Galindez Junirt

  • @jarmarielamao5952
    @jarmarielamao5952 3 ปีที่แล้ว +1

    Sir gud Eve po,tanong ko lng po,may ginagawA po ako na freezer na vaccum ko n po nagpalit na din Ng filter naflasing Marin po kaso nilagyan ko Ng refrigerant ayaw po uminit lahat ung condenser,half lng ko po uminit,tnx sa sagot

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Baka nnn compressor mo hindi na kaya mag bomba check mo presre if nakakaabot pa 300psi

  • @MichaelB.BaltazarIII-bz5cb
    @MichaelB.BaltazarIII-bz5cb 8 หลายเดือนก่อน +1

    Sir bago lang akong technician, may ginawa akong upright freezer, ayaw nang lumamig, chenik ko ang basic ang plug ,relay,olp at csr ok naman, nag palit ako ng acces valve sa charging kaso wala ng refregerant, so nag flushing ako at ang daming both condenser at lalo na sa evaporator, so to make the story short nag karga na ako ng freon , nag ha high amp. Ok naman po ang rating ng compressor ano ho kaya problema ?

    • @MrGerbee2
      @MrGerbee2  8 หลายเดือนก่อน

      Sure kaba hindi nagbabara? Or baka me tama na compressor mo hindi na nya kaya pag me karga

  • @alzkeithtv3104
    @alzkeithtv3104 ปีที่แล้ว

    Sir ung kakabili Kong ref...
    Ang nakalagay sa rated current po Niya is .55 amp.
    Tpz Nung sinasak ko mataas.. tpz Nung 12 hours mahigit na nakasak sak is pumapalo po sa .70

    • @MrGerbee2
      @MrGerbee2  ปีที่แล้ว

      ok lng po yan as long as ok lamig,, di nmn po eksaktong accurate mga nakalagay sa actual kasi sa kuryente me affect din if ore than 220 or below

  • @kevinantenero1829
    @kevinantenero1829 3 ปีที่แล้ว

    Sir advice naman. Bakit madalas nangyayare sa daikin inverter . Mababa ang amperahe nya tapos ang taas ng karga. Kahit di rin sya nag hihigh speed at hirap ang compressor. Kahit kaka reprocess lang. Salamat po . Godbless

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Boss kung nasasabi mo mababa ampere tapos mataas karga loose compression kna po...kaya sia hirap kasi mataas na karga mo... mag test ka alone sa compressor para malaman mo kaya nga pa bang mag pump or hindi na

  • @jaredmugar7334
    @jaredmugar7334 2 ปีที่แล้ว

    Sir good day ask ku lang po! Meron akung compressor na may code number FFI 6 HAK embrako na brand anong capacity ng compressor! Na to? I hope u can give some info! Thanks sir!

  • @r4inim4tion
    @r4inim4tion 3 ปีที่แล้ว

    S mkatuwed kahit 1000Amps pa ang charger basta same voltage ang requirement sa device wlang problema pero kung mas mtaas ang V at same AMPS eh msisira nga nmn amg device diba

  • @turoym.o.t9813
    @turoym.o.t9813 6 หลายเดือนก่อน +1

    SER GUD PM PO, BALAK Q PO SANANG GUMAWA NG DIY N AIR COMPRESSOR, ASK QPO SANA KUNG ASAN PO UNG LINE1 AT LINE2? SLMAT PO.

    • @MrGerbee2
      @MrGerbee2  6 หลายเดือนก่อน +1

      Tester boss malalaman mo sa compressor

  • @robertsuiza1516
    @robertsuiza1516 ปีที่แล้ว +1

    Any compressor Inverter pwede isalang any brand

    • @MrGerbee2
      @MrGerbee2  ปีที่แล้ว

      Pwede basta same ang sukat at alam mo ang connection iba kasi baligtad

  • @jobjabil4175
    @jobjabil4175 5 หลายเดือนก่อน +1

    Sir good morning bakit Po nagkabit Ako ng Bago compressor at nagkarga Ako bakit taas baba Ang karga tapos uminit agad Ang compressor ano advice nyo Po thanks

    • @MrGerbee2
      @MrGerbee2  4 หลายเดือนก่อน

      Barado po.. if magpalit ka compressor sa ac po palit ka rin cappiliary for your safety

  • @fredericonatividad8316
    @fredericonatividad8316 ปีที่แล้ว +1

    Sir may itatanong lng po ako about sa ref ko n maliit build in po sya di ko mabuksan sa likod OK nman thermostat, OLP, RELAY nya sa likod po parang may kumukulo bandang taas ano po yun parang Doon lumalabas ang lamig..

    • @MrGerbee2
      @MrGerbee2  ปีที่แล้ว

      hissing sound po ata nadidinig nyo which is normal sa mga fridge

  • @venjotv04
    @venjotv04 3 ปีที่แล้ว

    Sir ask ko lang normal lang ba sa ref yung halus hindi humihinto walang patayan yung compresor. Bagong bili lang kc namin ung panasonic econavi no fros inverter namin. Napansin ko kc halus hindi na mamatay kahit sobrang yelo na yung mga laman ng freezer. Nani bago lang ako yung dati kc namin ref na sinaunang ref kada 10 mins yata na mamatay. Yung bago kc namin ref ngayun hindi sya nag aautomatic namamatay halus kalahating araw yata bago mag automatic namamatay normal lang ba yun sir

  • @dhorskie9188
    @dhorskie9188 3 ปีที่แล้ว +2

    Sir salodo ako sayo sana ganon lahat ang isang katulad mo

  • @diosdadomendoza9359
    @diosdadomendoza9359 3 หลายเดือนก่อน

    good evening. nagtritrip ang overload protection ng ref motor saglit lang naka-on ang motor. ano po ba dahilan favor naman sir. salamat

  • @ricdasalla4993
    @ricdasalla4993 ปีที่แล้ว +1

    Sir, yong ref namin naiwanan bukas ng konte magdamag bandang taas Po. MAy possible ba na maubusan ng freon kasi di na Po nalamig naugong nman Po yong fan at nailaw din...medyo umiinit Naman Po ng konte yong compressor nya di tulad ng dati mainit sya pati tong tubo na maliit... frost free Po ref namin sir... salamat

    • @MrGerbee2
      @MrGerbee2  ปีที่แล้ว

      If naiwan magdamag at umingay baka namuo yelo sa loob kaya me maningay observe mo pa. Pag ganun pa rin try to manual defrost mo iwan mo bukas pinto ng naka off

  • @topheraquino7434
    @topheraquino7434 ปีที่แล้ว +1

    Sir,salamat sa kalaman,,,sir natural lang ba na uminit ang compressor at nmamatay tapos aandar ulit ,pero pag namatay cya mairinig mo tonk yan ang tunog,hingi kolang maliit na freezer 24 litters lang sya lumalamig naman Yun nga pag lamig nya mamatay pag Wala nang lamig aandar nanaman,,, natural lang ba yung tunog pagnamatay?,salamat sir new subscribers po ako na gustong matuto...

    • @MrGerbee2
      @MrGerbee2  ปีที่แล้ว

      Opo normal sa lahat ref nag off compressor then aandar ulit pag nakiha lamig stop sia then andar pag bumaba lamig

    • @topheraquino7434
      @topheraquino7434 ปีที่แล้ว

      @@MrGerbee2 salamat sir ng marame,,,nag aral ako kahit wala akong alam sa electronics,,,sana matuto ako sa iyo, salamat po ulit,,,

  • @painitanelimar
    @painitanelimar 2 ปีที่แล้ว

    boss pwede po b kau mag hone service??

  • @jeromemaster2103
    @jeromemaster2103 3 ปีที่แล้ว +1

    Boss ok lng ba ikabit yung 240 v na overload sa freezer khit 110 v lng sya

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Yes pwede overload lang sia pero maging problema lang is check mo if baka kuntin init cut off na pwero if hindi nmn is ok lang

  • @wilfrandonapay6017
    @wilfrandonapay6017 3 ปีที่แล้ว +1

    Sir meron akong washing machine media brand po.ayaw po kasi lumabas ng tubig po.twin po ung washing machine ko.pano ko po ba matatangal ung mga dumi dun po.salamat inadvance po.gid bless po

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      If tein tub po baka me bumara na medyan malimit or baka hindi na nahira yung drain wire nya kya hindi nabukas drain valve sa likod buksan nyo po me makikita kayung salikod na para me plastic cable na humihila sa drain valve

  • @leonardovallesduransolonia7122
    @leonardovallesduransolonia7122 3 ปีที่แล้ว

    Sir bakit Ang window type na air-con pag pina andar within 3hrs magtitrip shut down Ang circuit breaker nya..tapos Ang compressor sobrang init.

  • @gwapzolavides2404
    @gwapzolavides2404 3 ปีที่แล้ว +1

    Paano po kpag malamig nman ang buga peru nag high ampere pdn po?
    Nag plit nku bago capacitor bagong linis. Ndn ung unit. Ganun pdn. Nag high ampere pdn.

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Pwede po kasi barado ang high side pag nag high amp... pero pwedeng compressor na... pwede ring sobra sa karga... ma check lng yan pag nakahulog connection nya then paandarin compressor if mag hign amp comp na nga pero pag nag normal pwede na dun sa ibang nasbi ko

  • @melchorsungaben3623
    @melchorsungaben3623 ปีที่แล้ว +2

    Sir normal po ba mag turbo ang andar ng inverter compressor tanggal na ang discharge at suction line..at tumataas ang amperahe nya..?

    • @MrGerbee2
      @MrGerbee2  ปีที่แล้ว

      Opo me brand or model kahit tanggal na discharge mag full speed sia merun nmn di nag full speed kasi wala sia na sense na lamig depende sa design ng main board

    • @MrGerbee2
      @MrGerbee2  ปีที่แล้ว

      Yes inverter mababa amp then habang nag speed sia tataas din amp nya

  • @user-rr4wk3dq2n
    @user-rr4wk3dq2n 6 หลายเดือนก่อน +1

    Bakit po yung kinargahan ko lang after3-4days nag highamper na sya patay sindi na sya ok naman yung relay at olp

    • @MrGerbee2
      @MrGerbee2  6 หลายเดือนก่อน

      Baka po nagbabara sia? Or sadyang ma.sira na compressor. Na try mo ba me capasitor kasi ibang compressor na ayaw umandar nilalagyan ko capasitor naging ok na

  • @jefryduranan1740
    @jefryduranan1740 ปีที่แล้ว +1

    Boss gomez pwd po bangmag OJT sa company'snyo po

    • @MrGerbee2
      @MrGerbee2  ปีที่แล้ว

      boss yan video na yan africa pako nasa australia napo ako ngayun...me vdeo ako panu nakarating dito pahanap na lng baka makatulong po sa inyo

  • @alfredolopez954
    @alfredolopez954 3 ปีที่แล้ว

    sir,magandang araw po.bka matulungan mo ako LG washing machine [front load 6 kg] paano magcheck ng door switch at mag buypass?

    • @alfredolopez954
      @alfredolopez954 3 ปีที่แล้ว

      inverter washing machine po ang unit

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Me mga unit ng inverter pwede i bypass if mabuksan mo door switch then picturan mo pwede ko ma check alin line nya.. tech po ba kayu? Mas madali if tech ka mas madali ko maipaliwanag baka pwede i bypass me 2 wire ka lang na pagdikitin

  • @crisologosagun7589
    @crisologosagun7589 2 ปีที่แล้ว

    Sir ang tanong ko lang po umpisa noong naiwan bukas ung ref nmin ng matagal (d nmlayan ng anak ko na d pala niya naisara ng maayos) tapos noong npansin ng asawa ko cguro mga 4 hrs syang nkabukas ung ref po kinapa ng asawa ko ang tagiliran ng ref sobrang init po hindi na ung dating init niya grabe tlagang init..kaya pinatay nlang ng asawa ko..mga after 1hr..pina on niya ung ref na grabe tlaga sobrang init tlaga ..nkakatakot ung init niya ..ano kaya ang problema sir?

  • @chrismore9198
    @chrismore9198 3 ปีที่แล้ว +1

    Bos Anu normal starting amper Ng 110volts na refrigerator

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว +1

      Double lang sa 220v halimbawa sa 22ov na amp is .7 so sa 110b is 1.4

  • @nextjob4229
    @nextjob4229 2 ปีที่แล้ว +1

    Bro pano kaya ung ac ko nag high amps po ok nmn ung mga capacitor napansin ko lang ung compressor winding ung nakuha ko 1.7ohms 1.8omhs at 3.4 halos magkapareho po ung running at starting.

    • @MrGerbee2
      @MrGerbee2  2 ปีที่แล้ว

      Almost ok nmn po sa windong resistance at high amp hindi magbabago ang resitance kaya sia high amp means stock up comp kasi maka start ng maayus

  • @edwinvillaceran245
    @edwinvillaceran245 3 ปีที่แล้ว +1

    Sir kung barado po ang system ano ang dapat gawin

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Boss reprocess lang tanging solusyon sa brado system

  • @jadztv6192
    @jadztv6192 3 ปีที่แล้ว +1

    Paano I flashing ang baradong system sir dikopa na try un ref

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Madaming pwede gamitin pero me mha video ako na nah flushing ako

  • @ronniearwita437
    @ronniearwita437 3 ปีที่แล้ว

    Nkakainis nga minsan pag nbasa ung mga comment na un...mhaba ung post n nangngailangan ng advise o tulong...sbay marami magrply PM SENT...feeling ko nag uunahan pa cla...minsan sbihin pa 5yrs ako nagwork abroad,,-tesda crtified ako...hehehe sbihin agad san location mo....

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Ganun talaga boss diko maisip bakit pm pwede nmn sumagot na lang pag maganda nmn sgot mo sure tatawag client

  • @mariopangan9877
    @mariopangan9877 3 ปีที่แล้ว

    Maraming salamat po.
    Yung ac unit ko po na panasonic 1hp ganun po ang problema.
    5.3 rated amperes po niya pero umaabot po ng 8.2.
    Ano po ba dapat gawin pag ka ganyan sa ac unit ko?

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      0ag nayaas amp nya halimbawa una normal.pag tagal nataaas amp either madumi unit mo or baka kulang sa gas or nagbabara system

  • @jamesrosales5715
    @jamesrosales5715 2 ปีที่แล้ว +1

    Boss pagkulang ba ang oil ng compressor maghigh ampere ba xa o stay lng din ung ampere salamat po godblzzz

    • @MrGerbee2
      @MrGerbee2  2 ปีที่แล้ว

      If kulang sia pero merun pa rin wala sia kinalaman sa high ampere.. as long as merun aandar sia mag high amp sia if sira na talaga like stock up or barado... maging cause ng kulang sa oil halimbawa is mababa sa half aandar sia pero di tatagal... yung iba nga kunti oil naandar pa pero di tatagal compressor.

  • @romaricocaalaman4291
    @romaricocaalaman4291 2 ปีที่แล้ว +1

    Sir panu Ang gagawen Kung nagbabara o barado, Anu Ang mga papalitan o aausin? Ung Sakin po kc omorder ako Lazada Ng olp high amp paren kc

    • @MrGerbee2
      @MrGerbee2  2 ปีที่แล้ว +1

      Boss pag nag high ampere nmn kasi madaming hindi lang dahil barado kundi dahil siran na rin comp po...

    • @romaricocaalaman4291
      @romaricocaalaman4291 2 ปีที่แล้ว

      @@MrGerbee2 maraming salamat po sir

  • @bhabeby16
    @bhabeby16 2 ปีที่แล้ว +1

    Master pa notice po Yung freezer ko American Home brand po umaandar po cya nag Yeyellow naman po pero after 1hr namamatay po cya, anu po kaya problem nito Master?
    Pa notice po please!!!!
    Salamat in advance

    • @MrGerbee2
      @MrGerbee2  2 ปีที่แล้ว

      Ok lang namamatay at as long as nakakabuo yelo kasi pag na reach nya na temp na set mo mamatay talaga sia minsan in 15min or 30 depende sa setting mo pero pag namamatay tapos di nakakabuo yelo baka me iba probleam

  • @rogelioalingcastre9674
    @rogelioalingcastre9674 ปีที่แล้ว +1

    boss bakit po nag hi high umper yung compresor ng outdoor

    • @MrGerbee2
      @MrGerbee2  ปีที่แล้ว

      Baka po stock up na sia kaya high amp na pwedeng naging cause nawalan gas or barado system

  • @milmarlife6735
    @milmarlife6735 3 ปีที่แล้ว +1

    Sir stuck up po thermostat ref.ko anu sira.

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Pag stock napo palitan if di kay s spray ng wd40

  • @kingmanicat587
    @kingmanicat587 3 ปีที่แล้ว +1

    sir pag good nman ang ampere pero nag yeyelo at mahina na ang lamig anu kya posible na problema ..

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Boss anubg unit po? Ref or ac

  • @gerrydiesta8692
    @gerrydiesta8692 3 ปีที่แล้ว +1

    Good day Po sir,,Kung ilang po standard charging ng r600 sa freezer upright

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว +1

      Sir 0-1psi lang po karga ng R600 moslty pag nag karga ako nahsisimula ako sa 30psi then pag andar na comp saka nako mah dagdag gang sa mah normalized sia sa 0-1 psi

  • @bjornphilipbarcelon3438
    @bjornphilipbarcelon3438 2 ปีที่แล้ว +1

    Kuya bakit po kaya ang aircon nmin ay mabubuhay pagnamatay wala na ang lamig sa kwarto bago sya mabuhay ulit

    • @MrGerbee2
      @MrGerbee2  2 ปีที่แล้ว

      Pwedeng natigil compressor or baka me iba pa sira like sensor or madumi

  • @user-pn7vh3wx6b
    @user-pn7vh3wx6b 2 ปีที่แล้ว +1

    tanong k lng kng anong problema ng compressor ng refregirator ko kc mababa ang coil resistance ng starting at runing ng coil?

    • @MrGerbee2
      @MrGerbee2  2 ปีที่แล้ว

      Boss mababa nmn talaga resistance ng mga compressor... 3 pin yan iba iba pero hindi parepreho...

    • @MrGerbee2
      @MrGerbee2  2 ปีที่แล้ว

      Mas mababa ba sia pag sa common mo nilagay?

  • @carlmiciano6121
    @carlmiciano6121 2 ปีที่แล้ว

    Sir asap po baka matulungan nyo ako yung ref kasi namin ilang palit na ako ng overload protector nasusunog po ang OLP ano po kaya problema

  • @marcosespinosa7889
    @marcosespinosa7889 3 ปีที่แล้ว +1

    Paano kung sumusoka na ng langis idol

    • @MrGerbee2
      @MrGerbee2  3 ปีที่แล้ว

      Depende sa suka nya madami naba pag ganun me tama na pero test mo compression nya if kya nga pa mag hold ng pressure

  • @turoym.o.t9813
    @turoym.o.t9813 ปีที่แล้ว +1

    SER, TNONG PO ULIT AKO, BALAK Q PO SANANG I CHANGE OIL UNG COMPRESSOR KC DAMI PONG TUMAGAS AT KULAY BROWN N PO UNG LANGIS NYA, ANO PO TAMANG PAG CHANGE OIL AT DAMI? SLMAT.

    • @MrGerbee2
      @MrGerbee2  ปีที่แล้ว +1

      100 ml lng nmn nilalagay ko.

    • @turoym.o.t9813
      @turoym.o.t9813 ปีที่แล้ว +1

      @@MrGerbee2 K SLMAT PO MULI.