Thank You so Much for guiding us in such a easiest way. But one thing can you please give us setup of Ashrae duct fitting software through Google Drive?
It's good practice to use softwares instead of manual calculation procedure because now a days you will have so many tasks to perform. So it's much better to use softwares. Anyways if you want to have manual calculation then I recommend you to use Ashrae/smacna standard handbooks there you find same tables I used in my video
very good and nice explanation... In case if we have other path, (which might not be farthest) but handles higher the CFM and has more bends than the farthest path diffuser, in that case this duct path might be having higher static than the farthest diffuser. Would like to have your advice on with respect to this. Thank you.
Yes that's right. Let's say if other path was little shorter in length than the longest path we had selected in our example and suppose that shorter path has more bends and fittings and have higher static pressure then that would be our critical path with more bends and fittings. Generally bends, fittings and special equipments have much more pressure loss than straight piece of duct
Hi. You can join channel membership to get access to required spreadsheet but if you need all spreadsheets then I recommend you to proceed through paypal which is one time payment option. Let me know your email address I will send you paypal invoice.
If you're talking about Revit software then you can change units by typing UN from the keyboard, units dialogue box will appear then you can change units. If you're talking about Ashrae duct fitting database then you can change units by going into utilities, under utilities you will find preferences and there you will find units tab to change units from IP to SI and vice versa
Precise# good videography# clear sound# to the point discription# best of all video
thankyou Brother
May Allah bless your good deeds. Can't really thank you enough for making this tutorial.
You have explained it in really easy and simple way. Thank u sir
Your way of explanation is so awesome and simple. I would like to see more videos on your channel. Thanks for sharing knowledgeable videos
Really well explained Sir. Thank you for one more helpful video
God bless you veri nice and easy way of explanation
You are a true inspiration for young engineers.
Thank you 😍
Very nice waqas Bhai... Hatts off to you..!!
Most awaited video,and all your videos are really helpful,can you make a video on Fire pump Room design , sprinkler design.
Yeah sure
How can I get this ashrae duct fitting data base software,I tried a lot any cracked version is there?
Hello Mr.Mohammed thanks for this vidéo it's very helpful .... it will be more helpful if you upgrade the audio quality... thanks for your time.
Sir you are doing a great JOB... Your all videos are very useful..i am kindly requesting to you pls make videos for PLUMBING DESIGN also..
Sure
Great tutorial with accompanying spreadsheets..
I pay you but not response
Send an email on syedmuhammadwATgmail.com along with payment screenshot
Very clear explanation, many thanks!
Awesome explanation Sir
Thank You so Much for guiding us in such a easiest way. But one thing can you please give us setup of Ashrae duct fitting software through Google Drive?
Sorry Ali this is CR software can't be shared that's why I didn't attach it
Awesome video Sir, really helpful for me. Thank you
That's really helpful video. Hats off
Very helpful videos by you.. Thank you very much. Kindly share Ashrae duct ditting database.
Sorry this software can't be shared because it's copyright material. You have to purchase it
Presentation is very Good. just let me know whether vertical head of duct converted into water column to be considered in static calculation.
Best explanation. Thanks sir
In this software, is it possible to calculate for plenum
For the shoe neck part how much to give and in date base which one need to be selected.
Good bro but we required manual calculation using data book bcz we are not using this software.
It's good practice to use softwares instead of manual calculation procedure because now a days you will have so many tasks to perform. So it's much better to use softwares. Anyways if you want to have manual calculation then I recommend you to use Ashrae/smacna standard handbooks there you find same tables I used in my video
Best video sir
Very helpful video sir
very good and nice explanation...
In case if we have other path, (which might not be farthest) but handles higher the CFM and has more bends than the farthest path diffuser, in that case this duct path might be having higher static than the farthest diffuser. Would like to have your advice on with respect to this. Thank you.
Yes that's right. Let's say if other path was little shorter in length than the longest path we had selected in our example and suppose that shorter path has more bends and fittings and have higher static pressure then that would be our critical path with more bends and fittings. Generally bends, fittings and special equipments have much more pressure loss than straight piece of duct
@@MEPEngineeringTutorials thanks for the clarification
I paid for membership yesterday, but have not received the xcel spreadsheet. Is it emailed, or do I access it through your channel?
Hi Brent, Kindly send an email to get excel sheet
Check your email
Very informative
Hi great tutorial
How can i purchase the excel sheet
Hi. You can click join button on channel to get channel membership, based on selected membership level material will be shared with you. Thanks
thanks you very much pro.
will the pressure loss be same if Air is going vertically upwards (From Floor yo terrace) and it is going vertically downwards(From Terrace to Floor)
Can you please explain how to calculate esp for plenum
Sir, what if the fan/AHU is ground/basement, and serving air to upper floor?.. Show we consider gravity resistance In this case?
Hi, such an intutive video. how the Fan Operating Airflow(CFM) is calculated or sized? would appreciate your response
Nice video sir, Please make more videos
Yeah sure
What absolute roughess value can be considered for PI Duct material!?
Great tutorials.. Maybe you can also include fans selection and duct sizing for ventilation system.. exhaust and fresh air system.. thanks
Can you tell me how you calculate pressure loss in plenum box....thanks
I tried replicate this on my Ashrae phone app and I got different results for different parts, can I know what temperature and humidity did you set ?
I got a different friction factor
Nice video!
Hi sir, If find of top to bottom static pressure in duct, how can I use this static pressure ? for this AHU,FCU etc. comment plz
Thanks for explanation
Hello Sir , How can I get that Excel? thank you
Hi. You can join channel membership to get access to required spreadsheet but if you need all spreadsheets then I recommend you to proceed through paypal which is one time payment option. Let me know your email address I will send you paypal invoice.
How can i get an excel sheet of External Static Pressure losses, please.
Dear Yousif kindly join TH-cam channel membership to get access to this spreadsheet
Thanks
Can I get the excel sheet please I could use this very much thank you
Good explanation, can u send me this excel sheet please
Thanks for the videos
Can you provide link to download software for calculation of pressure loss
Sorry rajiv this software is CR material, can't be shared
Sir please make it basic to advance
super
Sir I payed for getting excel sheet. But still cant access it.kindly do needful
May I know how did you pay?
@@MEPEngineeringTutorials
89
Sir I need Esp calculation Excel sheet.
Kindly mail me
rrajithp@gmail.com
I need to know how did you pay?? because there is no sign of membership besides your display name on TH-cam
@@rajithpattathil1840 can you send me the excel page bro
Sir can provide download link for duct fitting data base software
Sorry this is copyright material can't be shared. Rest of the material I already shared in my video description.
How to change units for this software.
If you're talking about Revit software then you can change units by typing UN from the keyboard, units dialogue box will appear then you can change units.
If you're talking about Ashrae duct fitting database then you can change units by going into utilities, under utilities you will find preferences and there you will find units tab to change units from IP to SI and vice versa
@@MEPEngineeringTutorials thank u very much sir.i am learning a lot of things from this channel.
i want excel sheet sir
Dear Feroz kindly join channel membership by clicking join channel button on this channel to get access to excel sheet
I sent email and didn't receive data yet
Dear Beshoy your email has not been received yet. kindly check the email address and re send an email. Thanks
Sir please send me the excel sheet
@Venu Akula kindly join channel membership to get access to excel sheet
I paye you but not response
Dear Anil, if you have paid sent an email on syedmuhammadw@gmail.com along with payment screenshot.