MR JE C Servo ( Home & Positioning) with FX5U Part 2 (CC link IE Field Basic)

แชร์
ฝัง
  • เผยแพร่เมื่อ 8 ส.ค. 2020
  • CC Link IE Field Network Basic is compatible Servo Amplifier MR-JE-C.
    GX-Works 3 Parameter Setting
    • Device Numbers Used For Read/Write Function
    • Communication Start Setting
    • Program Operation Modes - Velocity Mode
    Device Numbers used to Write from Master station to servo Amplifier and to
    Read from Servo Amplifiers to Master station
    ------------------------------------------------------------------------------------------------------------------------------------------
    Program Sample At:
    automationsolutions.tk/
    automationsolutionz.blogspot....
    Download Sample Section
    ------------------------------------------------------------------------------------------------------------------------------------------
    To operate the amplifier in velocity mode switch amplifier to “Profile
    Velocity Mode (pv)”.
    • To Switch the amplifier to “Profile Velocity mode (pv)” write value ‘3’
    (i.e. K3) to Control word (i.e. RWw00).
    • After switching to “Profile Velocity Mode (pv)” write “Target Velocity”
    to Speed Command (pv) (i.e. RWw00 + 07).
    • While operating the amplifier in “Profile Velocity Mode (pv)”, the “Bit
    No. 15” should be on with the start command.
    • To start velocity movement write value ‘32895’ (i.e.K32895) in control
    command. (i.e. RWw00 + 01).
    • Depending on the sign of “Target Velocity” direction of movement will
    be decide.
    (i.e. Positive velocity Forward-Rotation,
    Negative velocity Reverse-Rotation.)
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 31

  • @chetankatageri5845
    @chetankatageri5845 3 ปีที่แล้ว +2

    Thankyou for the video. I was having a lot of confusion, but after watching this video all my confusions got cleared......
    Thanks alott

  • @srinivasangopinath3793
    @srinivasangopinath3793 3 ปีที่แล้ว +2

    Thanks a lot for the part2. Most awaited one.

  • @user-uh8lo9op4t
    @user-uh8lo9op4t 4 หลายเดือนก่อน

    Very very good tech video you Are doing such a wonderful job... thank you so much 🙏

  • @jesusaliagapoma2428
    @jesusaliagapoma2428 2 ปีที่แล้ว

    Hello, excellent video, could you explain how it would be the case for an ethertnet communication using an EDS file of the servo drive for any controller. Thank you

  • @amitpathak3p825
    @amitpathak3p825 2 ปีที่แล้ว

    Thanks for to shared such valuable information, its help us lot. Can any one let me know how to read actual current (Amp. ) value from servo drive just like we can read from VFD.

  • @krishangoyal9739
    @krishangoyal9739 2 ปีที่แล้ว

    Sir once the positioning is done which bit will be high?

  • @maheswaran9727
    @maheswaran9727 2 ปีที่แล้ว

    What are the setting to be done at amplifier side

  • @krishangoyal9739
    @krishangoyal9739 2 ปีที่แล้ว

    Sir
    How can I reset D1003 ( present position).
    I want to get it zero at a specific condition.
    Can I do?

  • @sheikameer8235
    @sheikameer8235 2 ปีที่แล้ว

    WHY K31 AND K 95 ARE MOVED TOWARDS CONTROL WORDS

  • @hapham-qd4jl
    @hapham-qd4jl ปีที่แล้ว

    how to turn SON ON.( Servo ON). Don't use CN3

  • @gameshowhot6346
    @gameshowhot6346 3 ปีที่แล้ว +1

    Do you use the CN3 origin input?

    • @Technocrats91
      @Technocrats91  3 ปีที่แล้ว

      Parameter PT45 is set 37, which is for Data set homing method,
      You can use CN3 Pin No. 2 DOG For other homing methods.

    • @Technocrats91
      @Technocrats91  3 ปีที่แล้ว

      For more clarification you can refer manual
      MR-JE-_C SERVO AMPLIFIER INSTRUCTION MANUAL (PROFILE MODE)

    • @gameshowhot6346
      @gameshowhot6346 3 ปีที่แล้ว

      Can you give me gmail, or contact information

    • @gameshowhot6346
      @gameshowhot6346 3 ปีที่แล้ว

      If I am not using CN3, what home method do I use.

    • @Technocrats91
      @Technocrats91  3 ปีที่แล้ว

      himanshutech13@gmail.com

  • @SwarajSinghSTC
    @SwarajSinghSTC ปีที่แล้ว

    Sir please Send link of this User manual

  • @davidekadukowski4656
    @davidekadukowski4656 หลายเดือนก่อน

    What are the first 2 lines for?

    • @Technocrats91
      @Technocrats91  หลายเดือนก่อน

      To start communication between plc and cc link ie field basic device

  • @patelromilnareshbhai
    @patelromilnareshbhai 3 ปีที่แล้ว

    Can i write more than one point table at one time??

    • @Technocrats91
      @Technocrats91  3 ปีที่แล้ว

      Yes

    • @patelromilnareshbhai
      @patelromilnareshbhai 3 ปีที่แล้ว

      @@Technocrats91 then sir can you please mail me sample program of it or any video how to write multiple point table at same time
      romil1993@gmail.com

    • @patelromilnareshbhai
      @patelromilnareshbhai 3 ปีที่แล้ว

      Hello sir will you share any backup or sample for multiple poont table write in single time
      romil1993@gmail.com

    • @Technocrats91
      @Technocrats91  3 ปีที่แล้ว

      Sure

  • @rojor7458
    @rojor7458 หลายเดือนก่อน

    Dónde encuentro el documento Acrobat

    • @Technocrats91
      @Technocrats91  หลายเดือนก่อน

      From Mitsubishi Site or just type mr je c communication manual in Google

  • @muhammadfassil4726
    @muhammadfassil4726 3 ปีที่แล้ว

    MR configuration settings for MR- JE -C

  • @manorhydraulicsautomation2817
    @manorhydraulicsautomation2817 20 วันที่ผ่านมา

    Sir Contact detail please