The rate of change helps you anticipate if your vacuum test will pass or fail. Therefore you waste less time. Example: say you gauge reads 500 and your targeting 1000 mics in 10 mins. if the rate of change is 100 mics per minute, you will reach your target in 5 mins. FAILED TEST However if your rate of change is 10 mics/ min then you will only at 600 in 10 mins. PASSED. Saves you the waiting time. Hope i explained correctly.
Eagle Mechanical Refrigeration/Hvac Durham N.C so after i pull a vacuum with this tool on a new condenser, and i backseat the king valves to release the freon into the system, wont the freon and oils and pressure get inside the micron gauge itself? or after vacuum i take micron gauge off before releasing freon but then the depressor will have a brief time to let the vacuum escape
I have owned two of these field Piece of Sh%@!Both had the same problem occur.They read Open line "OL"I will never buy another one, field piece dropped the ball on this product. I am not the only one with this problem.
Excellent demonstration I just bought one of these used Set it up just like you did to verify operation work great thank you
Do you have a video using the fieldpiece svg3 gauge on a mini split that don't need freon added
This comment doesn't make sense. This if for measuring a vacuum during the evacuation process
have tool check vacuum how many L/min ?
we intend to import to Viet Nam, but we scared if it had a problem , because we saw many comment
What does the rate of change mean?
The rate of change helps you anticipate if your vacuum test will pass or fail. Therefore you waste less time.
Example: say you gauge reads 500 and your targeting 1000 mics in 10 mins. if the rate of change is 100 mics per minute, you will reach your target in 5 mins. FAILED TEST
However if your rate of change is 10 mics/ min then you will only at 600 in 10 mins. PASSED.
Saves you the waiting time. Hope i explained correctly.
Why didn't you make it magnetic also.I guess that will be on the next one
Eagle Mechanical Refrigeration/Hvac Durham N.C so after i pull a vacuum with this tool on a new condenser, and i backseat the king valves to release the freon into the system, wont the freon and oils and pressure get inside the micron gauge itself? or after vacuum i take micron gauge off before releasing freon but then the depressor will have a brief time to let the vacuum escape
Deveria ser dublado este vídeo aqui tem muitos clientes brasileiro
Nice!!!
No İngilizce :(
I have owned two of these field Piece of Sh%@!Both had the same problem occur.They read Open line "OL"I will never buy another one, field piece dropped the ball on this product. I am not the only one with this problem.
TheHandofGod this only happens if there isn’t a good enough vacuum being pulled right?
I see OL at first too but then it begins to read.
I think it reads that when it has atmospheric pressures on it
🤔 is your vacuum pump working properly are the seals for the hoses and CPS VG sound did u change the vacuum pump oil
I love this micron gauge anyone who doesn’t obviously doesn’t know good tools and probably buys their tools at the local gas station
So far, I’ve had no problems with this tool.