Ultrasonic Flow Meter Explained | Working Principles

แชร์
ฝัง
  • เผยแพร่เมื่อ 2 ก.ค. 2024
  • ▶ C'mon over to realpars.com where you can learn PLC programming faster and easier than you ever thought possible!
    ▶ You can read the full post here
    realpars.com/ultrasonic-flow-...
    ⌚Timestamps:
    00:00 - Intro
    00:54 - Ultrasonic flow meter
    01:20 - Physical principles
    02:00 - Mechanical principles
    02:49 - Electrical principles
    03:16 - Dynamics
    05:16 - Design considerations
    06:40 - Applications
    =============================
    There are many types of process flow meters:
    - Coriolis mass flow meters;
    - Positive displacement flow meters, such as turbine meters;
    - Volumetric flow meters, like the ultrasonic flow meter, just to name a few.
    Each type of flow meter operates on different physical, mechanical, and electrical principles.
    In this video, we will explore the working principles for Ultrasonic flow meters. We will demonstrate how a simple physical property, sound, can be used to measure the rate of flow of a fluid moving in a pipe.
    Ultrasonic flow meters measure the volumetric flow of the fluid, that is, the number of gallons or liters per unit time.
    Ultrasonic flow meters require the use and understanding of some basic physical, mechanical and electrical principles that allow ultrasonic flow meters to accurately measure flow rate over a wide range of flow conditions.
    Here are a few examples of using basic physical, mechanical, and electrical principles to measure the flow rate using an ultrasonic flow meter:
    1) When fluid flows through a pipe, it flows in one direction at a velocity that is influenced by many factors, such as temperature, pressure, fluid viscosity, and pipe size.
    2) Sound waves move through a fluid based on the transmission of vibrations through the fluid. These mechanical oscillations between molecules of the flowing fluid are passed to adjacent molecules, thereby transferring the wave to those adjacent molecules.
    3) An ultrasonic flow meter generates sound waves using a rapidly vibrating piezoelectric crystal. These special ceramic crystals deform when an electric current is applied. By rapidly changing the electrical signal, the crystal will deform in one direction, and then in the other, causing a high-frequency wave to be generated.
    An ultrasonic flow meter consists of at least one sensor and transducer pair. Each member of the pair can act both as a transmitter and a receiver.
    - When in transmit mode, an oscillating electrical current creates a vibration in the piezoelectric crystal, and an ultrasonic wave is sent through the flowing fluid.
    - When in receive mode, an ultrasonic wave passing through the fluid creates vibration in the piezoelectric crystal, and an electrical impulse is generated.
    A pulse that travels from the upstream element to the downstream element, or with the flow, takes less time to make the trip than the pulse returning in the opposite direction, or against the flow. The difference in this time of flight between the two pulses is directly proportional to the flow velocity.
    Since the volumetric flow rate is equal to velocity times the cross-sectional area of the pipe, which is fixed at the flow meter, this measurement yields the flow rate. This type of ultrasonic flow meter is appropriately named a time of flight flow meter.
    In order to eliminate differences in the flow profile across the pipe, additional pairs of sensors are added to ensure an accurate measurement. Each pair of transmitter and receiver forms what is called a chord.
    There are many different ways that the sensors are mounted in a time of flight ultrasonic flow meter.
    - The sound wave pulses can travel directly from transmitter to receiver or the pipe wall can be used to reflect the sound waves.
    - The sensors can be wetted, or built into the wall of the flow meter such that the sensors contact the fluid. Or the sensors can be strapped to the exterior of the pipe, where the sensors do not contact the fluid. The non-contact sensors are not quite as accurate.
    Ultrasonic flow meters are an excellent choice for high-pressure, high-flow applications.
    =============================
    Get a RealPars pro membership: learn.realpars.com/bundles/pro
    =============================
    Missed our most recent videos? Watch them here:
    realpars.com/structured-text
    realpars.com/hydroelectric-power
    realpars.com/pt100
    =============================
    To stay up to date with our last videos, make sure to subscribe to this TH-cam channel:
    bit.ly/realpars
    =============================
    TWEET THIS VIDEO: ctt.ac/7hTsP
    =============================
    Follow us on Facebook 👉 / therealpars
    Follow us on Twitter 👉 / realpars
    Follow us on LinkedIn 👉 / realpars
    Follow us on Instagram 👉 / realparsdotcom
    #RealPars #UltrasonicFlowMeter #Sensor

ความคิดเห็น • 106

  • @mohammedfatehkhan8091
    @mohammedfatehkhan8091 2 ปีที่แล้ว +5

    I was literally waiting for an ultrasonic flowmeter video.
    Thanks realspars.

    • @realpars
      @realpars  2 ปีที่แล้ว

      Hope you enjoyed it!

  • @emmanuelsanusi1389
    @emmanuelsanusi1389 2 ปีที่แล้ว

    Thank you Realpars

  • @MehrMoon1335
    @MehrMoon1335 2 ปีที่แล้ว +3

    Concise, precise and informative

    • @realpars
      @realpars  2 ปีที่แล้ว

      Thanks a lot!

  • @Daniel-yt6ls
    @Daniel-yt6ls 2 ปีที่แล้ว +1

    Just as usual, amazing job!

    • @realpars
      @realpars  2 ปีที่แล้ว

      Thank you, Daniel!

  • @CALeftHander
    @CALeftHander 3 หลายเดือนก่อน

    Perfect educational video for me. Thank you for sharing.

    • @realpars
      @realpars  3 หลายเดือนก่อน

      Glad you enjoyed it!

  • @danieldapilma141
    @danieldapilma141 ปีที่แล้ว

    Great video. Very informative and easy to understand. You have gained a subscriber!

    • @realpars
      @realpars  ปีที่แล้ว

      Awesome, thank you!

  • @sciencetech9204
    @sciencetech9204 2 ปีที่แล้ว +1

    Thank you for useful contents

    • @realpars
      @realpars  2 ปีที่แล้ว +1

      Our pleasure!

  • @pavunumuthu9510
    @pavunumuthu9510 2 ปีที่แล้ว

    Very information video respect full real pars. Ultrasonic video

    • @realpars
      @realpars  2 ปีที่แล้ว +1

      Big thanks!

  • @TrungLinhNguyennn
    @TrungLinhNguyennn ปีที่แล้ว

    Very useful clip, thank you for sharing

    • @realpars
      @realpars  ปีที่แล้ว

      Glad it was helpful! You're very welcome.

  • @SHOREHILLEYEWEAR
    @SHOREHILLEYEWEAR ปีที่แล้ว

    Thank you! This is awesome!

    • @realpars
      @realpars  ปีที่แล้ว

      Glad it was helpful!

  • @IngDzib
    @IngDzib 2 ปีที่แล้ว +1

    Thank you!!

    • @realpars
      @realpars  2 ปีที่แล้ว +1

      No worries!

  • @bitebonumbere1426
    @bitebonumbere1426 2 ปีที่แล้ว

    Thanks RealPars

    • @realpars
      @realpars  2 ปีที่แล้ว

      You're very welcome, Bitebo!

  • @mahdisharifi803
    @mahdisharifi803 2 ปีที่แล้ว

    Thanks real pars. Very good

    • @realpars
      @realpars  2 ปีที่แล้ว

      Always welcome!

  • @Belanak88
    @Belanak88 2 ปีที่แล้ว

    Thanks for your transfer knowledge

    • @realpars
      @realpars  2 ปีที่แล้ว

      It's our pleasure

  • @asadiqbal87
    @asadiqbal87 2 ปีที่แล้ว

    very informative thanks real pars make more videos on instrumentations

    • @realpars
      @realpars  2 ปีที่แล้ว

      Thanks for your support, Asad!

  • @Railbugman
    @Railbugman 2 ปีที่แล้ว

    Excellent video.

    • @realpars
      @realpars  2 ปีที่แล้ว

      Thank you very much, Jeff!

  • @roseelectronics4582
    @roseelectronics4582 2 ปีที่แล้ว

    Great!

  • @mfasiu
    @mfasiu 5 หลายเดือนก่อน

    Fantastic job

    • @realpars
      @realpars  5 หลายเดือนก่อน

      Thank you very much!

  • @nilfanwadood3923
    @nilfanwadood3923 ปีที่แล้ว

    Great explanation given thanks sir

    • @realpars
      @realpars  ปีที่แล้ว

      Always welcome!

  • @alterator
    @alterator 3 หลายเดือนก่อน

    Perfect

  • @logeshjeeva1231
    @logeshjeeva1231 2 ปีที่แล้ว

    Proud to be your subscriber.Thanks for this video.. 👍 Grabbing ease of learning in your videos..

    • @realpars
      @realpars  2 ปีที่แล้ว

      Thanks a lot, Logesh! Great to hear

  • @alikoohi8265
    @alikoohi8265 2 ปีที่แล้ว +3

    Great video...Can you make such an informative video on multi phase flow metering (with electrode and gamma ray source) principles??

    • @realpars
      @realpars  2 ปีที่แล้ว +1

      Hi Ali!
      Thanks for your comment and your suggestion. I will pass this on to our course developers!
      Thanks for sharing and happy learning!

    • @MrWaalkman
      @MrWaalkman 2 ปีที่แล้ว

      I remember beta gauges from the 80's. Nasty, dangerous things...

  • @rameshpram1444
    @rameshpram1444 2 ปีที่แล้ว

    Thank you

    • @realpars
      @realpars  2 ปีที่แล้ว

      You're welcome!

  • @mrb1222
    @mrb1222 2 ปีที่แล้ว

    Great

  • @yasinmuc
    @yasinmuc 2 ปีที่แล้ว

    Thanks I'm addicted to your uploads I don't miss any

    • @realpars
      @realpars  2 ปีที่แล้ว

      Glad to hear that!

  • @bunnandjenn9405
    @bunnandjenn9405 2 ปีที่แล้ว

    Thanks

    • @realpars
      @realpars  2 ปีที่แล้ว

      Our pleasure!

  • @cck1496
    @cck1496 2 ปีที่แล้ว +4

    As usual excellent work. Can anyone tell please:
    In which case, (for gases) we have to measure " mass flow rate" and in which case we will have to measure "volumetric flow rate"?
    Thanks.

    • @alexandernorman5337
      @alexandernorman5337 2 ปีที่แล้ว +2

      If you know the fluid you are measuring, and if you know the temperature and pressure that it is at, then you can always convert between mass flow rate and volumetric flow rate. You can measure either, bring the measurement into the process supervisory computer, and convert there if needed.

    • @MrWaalkman
      @MrWaalkman 2 ปีที่แล้ว

      I suppose in a mixing scenario where you are metering the proportion of one material to another. Basically, so many pounds of this, to so many pounds of that. But for gases?
      Like Alexander said, adding a temperature sensor (as well as some math) will give you your mass. One exception to this is for steam. For most applications you can count on what its temperature is going to be, and just plug that number in.
      Or so says the ABB rep that sold me my meters... :)

    • @cck1496
      @cck1496 2 ปีที่แล้ว

      @@MrWaalkman Thanks for your kind reply.
      For gas turbine, mass flow rate is measured but for domestic consumption, it's volumetric flow rate.
      I may be wrong.
      Thanks.

    • @cck1496
      @cck1496 2 ปีที่แล้ว

      @@alexandernorman5337 Thanks for your kind reply. Keep it up.

    • @MrWaalkman
      @MrWaalkman 2 ปีที่แล้ว +2

      @@cck1496 You're welcome of course!
      When it comes to (natural) gas meters, I'm familiar with the Roots style (positive displacement), Diaphragm (bellows) meter (which IMHO are pretty cool as to how they work), and turbine gas meters (not positive displacement).
      What they all have in common is that you can get a temperature compensating drive for your meter's dial to correct for changes in measurement due to temperature. These gauge faces are (usually? always?) painted red. And you will see both flavors out in the wild (some municipalities choosing not to use compensation. Most seem to). So either way you are correct. :)
      Some random rambling follows...
      You also can usually install a pulser such as the "Pulsimatic" transmitter which will give you a pulse for a given volume passed through the meter (like one pulse per 10 cubic meters of gas). The standard setup on these is a C-form contact block which can be ordered instead with an A-form contact block. It will last much, much, longer with the A-form contact block. I would know, one of my assignments at Schneider Electric was to intentionally break things to see how long they would last in the field. Great assignment! I had no problem causing the C-form contact block to fail, but I never managed to make the A-form one break. My other assignment at Schneider was in Okinawa, which was pretty nice too. :)
      And occasionally you will see "shadow" meters installed when a facility is concerned that the utility's meter in not functioning properly. The opposite is true as well. Utilities have fake transformer cans that can house a meter to see if a homeowner or business owner is stealing power from the utility.
      When it comes to metering Liquified Natural Gas (LNG) or Liquified Propane Gas (LPG), it's a completely different animal. LPG has a Centipoise of .1 (for reference, water has a Centipoise of 1, making it 10 times more viscous than LPG). Which makes metering and pumping LPG a bit of a bear to do.

  • @firedon
    @firedon 2 ปีที่แล้ว

    how would you compare these to thermal mass flow meters for compressed air flow measurement?

    • @realpars
      @realpars  2 ปีที่แล้ว

      Since most gas flows of this type are small, thermal mass flow meters have the advantage of a smaller footprint than ultrasonic flow meters. For flow rates in the l/min realm, thermal mass flow meters are the only viable option. Ultrasonic flow meters typically require entrained solids to be useful in gas applications, and for compressed air, that is not acceptable.

  • @MrWaalkman
    @MrWaalkman 2 ปีที่แล้ว +2

    Ultrasonic flowmeters have one outstanding advantage in that you can temporarily mount them to existing pipes. This means that you can make measurements on all of your piping with just one meter. This saves a ton of money compared to installing a flowmeter per pipe.
    The downside is that (in my experience) the external ultrasonic flowmeters are a bit finicky to set up. But that can be said for a number of flowmeters. When it comes to metering, there are lies, damn lies, and flowmeters.
    And ultrasonic flowmeters also require 10x - 15x of straight pipe before the flowmeter and 5x of straight pipe past it. But this is a typical requirement for most other types of flowmeters as well.
    What this means is that if your pipe is 2" in diameter, then you will need 20" to 30" of straight pipe ahead of the meter, and 10" past it. Not a big deal when your pipe diameter is small, but try it on some 60" pipes (ductwork) sometime. :)

    • @cck1496
      @cck1496 2 ปีที่แล้ว

      Very good information. Keep it up.

    • @realpars
      @realpars  2 ปีที่แล้ว +1

      Thank you for your comments on ultrasonic flowmeters. These "clamp-on" type flowmeters have a wide range of applications, especially for processes where it is either too difficult to physically install an in-line flow meter type or the process is not amenable to in-line metering. Upstream and downstream pipe runs are considerations that cannot be overlooked, especially if you want to have the best measurement accuracy. Again, great comments, and thank you for supporting Realpars!

    • @alexandernorman5337
      @alexandernorman5337 2 ปีที่แล้ว

      Well, you don't need to meet that requirement you cite for straight pipe. You need to meet that to achieve the highest accuracy. But if you only need to be within ~5% then you can work with a lot less.

    • @MrWaalkman
      @MrWaalkman 2 ปีที่แล้ว

      @@alexandernorman5337 Not according to almost every installation guide that I have ever read. Coriolis meters don't need straight pipe IIRC, nor do wafer mags and possibly positive displacement meters, but pretty much everything else does. And if your upstream bends are not on the same plane then you need even more straight pipe.
      And I don't know if I agree with the 5% inaccuracy limit, that would likely depend on the type of flowmeter more than anything else. And the brand of meter makes a difference of course, some being better than others. I've definitely seen worse than 5%.
      I do know that the thermal flowmeters that we installed in place of the wafer mag meters didn't have the 10x, 5x "smoothing" zones and performed very poorly. But the application allowed for a 50% error without causing any process problems (we just needed to know that material was flowing, we didn't really care what the actual flow rate was). And these meters were all over the place. Any given instant you might see a 50% change in flow. But for our purposes they did just fine.
      The thermal flow meters were *very* attractive because they were completely smooth on the inside without any obstructions whatsoever. Because we were running paint through the meters we had to be careful not to create a place for "dirt" to accumulate. "Dirt" in this case is paint shop slang for paint clumps. Not actual dirt. Basically we didn't want goobers to form and plug up the robots. We also have to keep the amount of "shear" to the paint at a minimum. Shear breaks down the paint affecting the finish. So positive-displacement meters such as Roots type meters are out as well. Flow straighteners are a no-no too.
      DP, vortex, and turbine meters would have contributed to dirt. Coriolis was too expensive, and we didn't have enough room for ultrasonic meters. So thermals it was.
      The thermal meters fit in where the mags once were, with some changes to the plumbing of course, as well as sacrificing the straight flow requirements. But it all fit within the allotted equipment space.
      But so be it. If nothing else engineering is a game of compromises...
      So why replace the wafer mags? They were purchased without fully considering what the properties of the materials were that were going to be running through the meter. The meters were there for measuring the flow of paint as well as solvent that was being circulated through the tanks to the robots and then back to the tanks. It turns out that the paint that we were planning on using was non-metallic (as well as the solvent of course), so all 37 wafer mags showed "Empty pipe?" on each meter when running.
      Wafer mag meters, or at least these wafer mags, require metallic particles to function. So 37 brand new wafer mags in the dumpster.

    • @MrWaalkman
      @MrWaalkman 2 ปีที่แล้ว

      @@realpars You're welcome! And it's always a treat to see a new video show up. :)

  • @user-hh3ev2ls4s
    @user-hh3ev2ls4s 7 หลายเดือนก่อน

    Its Great video, more informative ..we need paint flow detect device. We take trail on Keyence FD_Q , it sense hardener and thinner only. Paint flow quantity not detect. Pls suggest any other flow that's sense flow quantity & control flows of paint.

    • @ahmetcemturan
      @ahmetcemturan 5 หลายเดือนก่อน

      Look for a doppler us flowmeter.

  • @user-wn7xv6uy9m
    @user-wn7xv6uy9m ปีที่แล้ว

    I enjoyed the video. I have a question.
    Looking at the path that ultrasound crosses, it seems to pierce the wall twice in the middle. By the way, can ultrasound penetrate a blocked wall?
    My experiment showed that ultrasound couldn't penetrate the wall.
    So I wonder if ultrasound can pass through obstacles.

    • @realpars
      @realpars  ปีที่แล้ว

      There are two types of ultrasonic flow meters: wetted and external. Wetted meters do not need to transmit through pipe walls, so they are more accurate than external (or wrap around) sensors. Sound waves can penetrate metal pipe walls pretty well. It is the same as hearing a conversation in the next room through a thin room wall.

  • @7_of_9
    @7_of_9 6 หลายเดือนก่อน

    Whats a good one for reading water consumption wireless?

    • @realpars
      @realpars  6 หลายเดือนก่อน

      Thank you for asking such a valid question, which many others have also raised. However, I must maintain the same response I've provided previously. Without specific details about your application and not being part of your technical team, regrettably, I'm unable to offer a precise answer. Nevertheless, I can certainly offer you a link to the manufacturers, providing an opportunity for further exploration and deeper understanding related to your learning objectives.
      www.keyence.com/about-us/corporate/ www.omega.com/en-us/ www.emerson.com/en-us/automation/measurement-instrumentation
      Happy learning!

  • @sdy22khg
    @sdy22khg 2 ปีที่แล้ว

    Can i get a video on how analog input are processed in PLC analog card.??

    • @realpars
      @realpars  2 ปีที่แล้ว +1

      Thanks for the topic suggestion, Pravin!
      I will definitely go ahead and forward this to our creator team.
      Happy learning!

  • @neptune9443
    @neptune9443 ปีที่แล้ว

    I see you reply to almost every comment so I'm going to take my chances and ask you something. I'm learning a lot from your videos but I am still not sure what is the best type of flow meter is for my case and I would appreciate if you could help me.
    I want to measure the volumetric flow of water through a 3/4 or 1" pipe for a potable water vending machine I am planning to build. See Watermill Express as an example. Which type of flow meter do you think would be the best choice for this case? I know turbine flow meters would probably work well but (leaving the cost factor aside for a moment) is the ultrasonic even better? Is it more accurate?

    • @neptune9443
      @neptune9443 ปีที่แล้ว

      or is there any other better option

    • @realpars
      @realpars  ปีที่แล้ว

      A turbine meter is the most compact and easiest to install for this application. A small clamp-on ultrasonic flow meter can also be used fairly easily, but is not as accurate as a turbine meter. Both have pulse outputs which will require an interface card, which is typically small and not expensive. A compact magnetic flow meter could be used, as long as the conductivity of the water is greater than about 10 microsiemens/cm or so (depends on the specific flowmeter).

  • @jonwatson9765
    @jonwatson9765 2 ปีที่แล้ว

    You seem to suggest that turbine meters are positive displacement. They are not. They are inferential meters or velocity meters
    They usually have a limited viscosity range enhanced with helical rather than straight blades.
    Ultrasonic meters, multichord, can handle fluids with viscosities as high as 4000 cst.
    What you didn't explore but rather simply brushed over to say this was why you had multichord Meyers, I'd that the sound wave transits from transmitter to receiver and is influenced by the fluid velocity. Should that not be " mean fluid velocity"?.
    It would have been helpful to. Explore the relationship between the measured transit time difference and laminar flows, transitional flows and turbulent flows.i would have expected to that swirl would have some effect. Not discussed.
    However, a good basic explanation. Tks.

    • @realpars
      @realpars  2 ปีที่แล้ว +1

      Jon, you are correct. Turbine meters are velocity meters in their principle of operation. However, they do share the property of positive displacement meters in that a single revolution is equated to a specific volume of fluid flow, albeit for a turbine meter this volume is calculated from the fluid velocity instead of a chamber volume.
      As this is an introductory video to ultrasonic flow meters, we did not get into the details of differences in sound profiles through laminar and turbulent flow streams or the meaning of mean flow velocity. Ultrasonic meters are nearly linear in response in turbulent flow ranges, but in laminar or transitional flow ranges, special conditioning sections upstream of the meter are required.

  • @nicolasriart6549
    @nicolasriart6549 2 ปีที่แล้ว

    how do ultrasonic flow meters perform on curved pipes?

    • @realpars
      @realpars  2 ปีที่แล้ว +1

      Ultrasonic flowmeters need a straight run of pipe to work accurately. Bends in pipes tend to distort the flow patterns and can lead to void spaces as the fluid makes the bend. Both of these issues can degrade the flow signal. Typically, a straight run of 10 pipe diameters upstream of the meter and 5 pipe diameters downstream of the meter will provide a steady and consistent flow pattern to allow for accurate measurement.

    • @winner1338
      @winner1338 2 ปีที่แล้ว

      There are Electromagnetic flow meters from Siemens that has a Venturi shape inside. And they claimed it could be placed just about 1 meter before the curve.
      Maybe there are something like that for ultrasonic flow meters.

  • @JorgeFlores-mj5rl
    @JorgeFlores-mj5rl ปีที่แล้ว

    Are ultrasonic meters able to flow bidirectionally?

    • @realpars
      @realpars  ปีที่แล้ว +1

      No. The ultrasonic transmitter is positioned to send sound waves in the direction of flow, and the receivers are a few pipe diameters downstream of the transmitter.

  • @fahmietalife
    @fahmietalife 2 ปีที่แล้ว +1

    Is it more accurate then Coriolis?

    • @ashwinmurali1911
      @ashwinmurali1911 2 ปีที่แล้ว +1

      Coriolis flowmeter measures mass flow rate, ultrasonic flow meter tells velocity of flow. If you wish to find mass flow rate from ultrasonic flow meter, you need know density of the fluid which is temperature dependent. so unless you have compensation techniques it cannot give accurate reading

    • @fahmietalife
      @fahmietalife 2 ปีที่แล้ว

      @@ashwinmurali1911 im asking for comparison of accuracy for volumetric flow rate between these two

    • @MrWaalkman
      @MrWaalkman 2 ปีที่แล้ว

      Coriolis is considered the "Gold standard" for mass metering. Not necessarily for flow.
      As for volumetric flow, according to sciencedirect:
      "The Coriolis meter will oscillate at a specific frequency depending upon the density of the fluid in the flow tubes. ... With proper calibration, the density of the drilling fluid can be determined from the frequency. Mass flow rate is density times volume, so the volume rate of flow can be accurately determined."
      So your flow measurement is only going to be as good as your density calculation.

    • @fahmietalife
      @fahmietalife 2 ปีที่แล้ว

      @@MrWaalkman thank you sir. Thats the problem that we have with our application, we're using Coriolis to measure flow rate but once the fluid is not homogeneous, we're not getting accurate flow rate. That's why i wanted to know if the ultrasonic flow meter is more accurate for using in our application.

    • @MrWaalkman
      @MrWaalkman 2 ปีที่แล้ว

      @@fahmietalife Yes, I would think so. Coriolis (like any other meter) is great for what it does well, but in this case it sounds like it was a poor choice. This is where a good meter rep is your friend. Try to pick a rep who sells a lot of different meters or your "perfect" meter will be the one that his company makes. ;>
      What are you metering, and do you have a Reynolds number for it?

  • @ashutoshjoshi4306
    @ashutoshjoshi4306 2 ปีที่แล้ว

    How are ultrasonic meter calibrated?

    • @realpars
      @realpars  2 ปีที่แล้ว

      Ultrasonic flowmeters are typically calibrated gravimetrically, by collecting water flowing through the meter at different flow rates into a collection tank. Because the gain of the meter usually varies with % of maximum flow rate, 10-20 calibration points from 0 to 100% are measured and the gain (correction) factor is calculated at each point to develop a curve. This only needs to be done periodically (every 1 - 2 years), more often for dirty or coating fluids.

  • @sinanartemis6176
    @sinanartemis6176 2 ปีที่แล้ว

    hi why dont you make a pcs7 course on siemens

    • @realpars
      @realpars  2 ปีที่แล้ว

      We do have an Introduction to PCS7 course that is available through subscription on the Realpars.com website! It includes network, hardware, and program configuration as well as WinCC graphic development using a simple process example. There is also an extension to the WinCC course for PCS7 that includes writing C-language routines to int4eract with the graphics.