Raza shah sahib . Mujhe 132 kw ki motor lagani hai . 550w ki plate hai.. 14 amp 49 volt . String kese banegi.aur breaker Konsa lagana hai. Mujhe 4 unit lagane hain
Sir wapda 3pphase 480 volt and solar panels 16 16 2string 750 volt pb 4 90 and pb5 30.00 sirif sooler plates per chlain to fercunci jump Kar rahi ha setting bbtain
Main ny 10 hp ki motor jo phely sirf solar py chal rehi thi,us ko 3phase wapda k connection ker k chalya ha, Aub problem ye ha k solar py motor 11 amp ly k sahi chalti ha or jub wapda py kerty hain to inv 8 amp py slow chalata ha. renmayi chaiy.
Chacha RST k connection ko change karne se koi fsrq nai parta motor ki rotation men kyon k RST Sirf DC convert karta tu connection kahin bhi lagao DC hi banega
Assalamu alaikum bhai jaan RST mein se Kisi do ko change karna padta hai aap teenon ko change kar rahe honge isiliye chakar change Nahin ho rahe honge aap r ko serf s sy change kr den
Assalam o alehukam. Shah g mainy wapda k thee phase connection vfd ko dy kr or pb 05 ki setting ko 00.00 kr dia phr Jb chalaya to masla yeh ha k motor sara load wapda sy lati ha solar sy bulkul nahi lati. Iski kya wajah ha. Vfd chf-100 ha. Plz lazmi jawab dy kr rehnumai krye ga.
Bhai jaan Jo ab new vfd a rahi hai in my auto detect hai lekin jo purani vfd thi UN mein auto detect nahin tha hamari khud ki ek vfd kharab ho gai thi usko humne pahle solar per chalaya hua tha FIR humne solar ko band Karke wapda se chalaya FIR humne donon ko mix Kiya to vfd mein dhamaka ho Gaya FIR humne use bande se rabta Kiya tha jisse humne vfd li thi fir usne hamen bataya ki aapane solar band karne ke bad wapda se motor Chala kar Uske RPM check karne the ke chakkar sidhe Hain ya ulte agar sidhe hote to tab jakar aapane solar mix karna tha aapane direct solar aur wapda comics Kiya hai jiski vajah se program confuse ho gaya hai.
Je je Bhai bilkul apne theek Kaha pb05 50hz sy oper NI hota reset mein. Lakin agar ap frequency KO 60hz py fix kren Tu fir 60hz tak jata hy . Bilkul ferfect hy apki bat
Bhai hamare pass 2 phase wapada ka ha agr hm 2phase wapada se solar band kr k wapada pr tube well chalaye tu vfd me konse setting hoge bhai zaroor as ka vedio banay
جی جی سنگل فیز کو مکس کرنے کیلئے vfd کو واپڈا دینے سے پہلے ایک سپلائی لگانی پڑتی ہے جو آپ کے سنگل فیز کنکشن کو تہری فیز میں تبدیل کرتی ہے۔اگر آپ کو وہ سپلائی ضرورت ہو تو آپ مجھ سے رابتہ کر سکتے ہیں۔
بھائی جان پائدار چیز تو وی ایف ڈی لیکن اس کے لیے اپ کو موٹر چینج کرنی پڑے گی کیونکہ خراد مشین پر عموما سنگل فیز موٹر لگی ہوتی ہے جو کہ وی ایف ڈی سے نہیں چل سکتی کیونکہ وی ایف ڈی تھری فیز ہوتی ہے اس لیے اپ کو اپنی موٹر پہلے تھری فیز کرنی پڑے گی چاہے اپ اسی موٹر کو تھری فیز کروائیں یا اس کو پیج کر تھری فیز موٹر لے لیں اگر اپ اسی موٹر کو تھری فیز کروائیں گے تو اپ کی دو ہس پاور کی موٹر جب تھری فیز ہوگی تو وہ تین ساڑھے تین حاس پاور کی بن جاتی ہے یا اپ اس کو بیچ کے تھری فیز موٹر لیں تو تین ہارس پاور کی تھری فیز موٹر بھی 20 سے 30 ہزار روپے کے درمیان مارکیٹ میں اپ کو مل جاتی ہے انورٹر جو ہے چاہے گھر میں بھی اج کل لگ رہے ہیں وہ کوئی اتنی پائیدار چیز نہیں ہے بہت جلد خراب ہو جاتے ہیں دوسرا انورٹر ٹارک بھی برداشت نہیں کرتا جب خراد مشین کی موٹر اپ سٹارٹ کرتے ہیں تو اس کا ٹارک جو ہے دو ہارس پاور کی موٹر کا کم از کم 40 ایمپیئر ہوتا ہے اس کے لیے انورٹر اپ کو کافی بڑا لگانا پڑے گا اس لیے بہتر یہی ہے اپ موٹر کو تھری فیز کر کے وی ایف ڈی لگا لیں شکریہ اللہ حافظ
السلام علیکم بھائی صاحب اب تھوڑا سا غلطی کر گئے ہیں جب ادھر سے اے سی دیتے ہیں تو اگے یہ بھی ڈی سی بنتی ہے اور پلیٹوں کی بھی ڈی سی بنتی ہے جو چکر اے سی پہ ہوں گے وہ سولر پہ بھی وہی چکر ہوں گے چکر الٹ نہیں ہوتے کبھی بھی یہ تھوڑی سی اپ کی مسٹیک ہے پلیز ذرا اپ یہ چیک کریں میں نے جو کہا ہے وہ صحیح کہا ہے یا غلط کا ہے
وعلیکم السلام جی بھائی اپ کی بات بھی ٹھیک ہے لیکن اصل میں مسئلہ یہ ہے کہ وی ایف ڈی کے اندر جو سافٹ ویئر ہوتا ہے اس کو وقت کے ساتھ ساتھ انجینئر لوگ اپڈیٹ کر رہے ہیں کچھ وی ایف ڈیز جو پہلے سے مارکیٹ میں موجود ہیں یعنی پرانی وی ایف ڈیز ان کا ان کا جو سافٹ ویئر تھا اس میں وی ایف ڈی اٹومیٹک ترتیب درست نہیں کر سکتی تھی جس کی وجہ سے عموما ہوتا یہی تھا کہ جب ہم سولر سے چکر سیدھے کر کے موٹر کو چلاتے تھے اس کے بعد واپڈا کے کنکشن دے کر ہم دونوں کو مکس کرتے تھے تو جو پرانی وی ایف ڈی ایم ہے اس کی بات کر رہا ہوں جس کا سافٹ ویئر پرانا ہے تو وہ دھماکے کی طرح پھٹتی تھی اگر اس کے چکر واپڈا کے اور ہوتے تھے اسی لیے میں نے ویڈیو میں یہ سمجھانے کی کوشش کی ہے کہ اگر کوئی دوست جس کے پاس پرانی وی ایف ڈی بھی ہو وہ بھی اور جس کے پاس نئی ہو وہ بھی وابڈا اور سولر کو مکس کرتے وقت کسی بھی بڑے حادثے سے بچ سکے ورنہ اپ کی بات بھی ٹھیک ہے جو نیو سافٹ ویئر ہے اس میں وی ایف ڈی خود بخود سیکونس درست کر سکتی ہے لیکن وہ بھی کچھ ماڈلز ایسے ہیں جن میں ڈیٹیکشن سسٹم نہیں ہے لہذا محتاط رہنا چاہیے
ماشاءاللہ بہت شکریہ بھائی آپ نے بہت خوب سمجھایا
JazakAllah
Zabardast ustad g
Good work......❤❤❤
Thanks
Good work
Good
So 👍👍 thanks again
informative vedeo
Badi meherbani bhajan
جزاک اللّہ
جزاک اللہِ
Bhai single phase wapda ki setting btai h ap na ya 3phase
Free drive vfd ki bhe yahe setting hai chaing hai
Raza shah sahib .
Mujhe 132 kw ki motor lagani hai . 550w ki plate hai..
14 amp 49 volt .
String kese banegi.aur breaker Konsa lagana hai. Mujhe 4 unit lagane hain
132kw?
Sir wapda 3pphase 480 volt and solar panels 16 16 2string 750 volt pb 4 90 and pb5 30.00 sirif sooler plates per chlain to fercunci jump Kar rahi ha setting bbtain
Pb05 ko zero kr den
@@shujabadi191jab. Wapda bnd ho jay to pb.05 ke zero krny se uu to nhi ay ga
Q K only solar pr pb.05 ko 10 se km krny se fault aa Jata he
Main ny 10 hp ki motor jo phely sirf solar py chal rehi thi,us ko 3phase wapda k connection ker k chalya ha,
Aub problem ye ha k solar py motor 11 amp ly k sahi chalti ha or jub wapda py kerty hain to inv 8 amp py slow chalata ha.
renmayi chaiy.
Aap PB,05 ko zero q kerwa rehy hain??
pl inform me.
sir ye single phase VFD main laga k 3 phase motor ko chalanay ka treka bataya hai ya 3 phase wapda say he mix ho sakta hai
Three phase wapda mix
Bhai single fase se wapda mix krna hai kyase kryn?
Sr agr wapda 2phese 380 ho to kia hum wapda ka crant vfd ko de sakty he
Dy sakty hen lakin settings Karni ho gi vfd mein
AP help kr sakty he vfd inverx ki he
🎉🎉🎉🎉😊😊😊😊😊
Chacha RST k connection ko change karne se koi fsrq nai parta motor ki rotation men kyon k RST Sirf DC convert karta tu connection kahin bhi lagao DC hi banega
Mixing mein program distrub ho sakta hy warna wapda sy koe farq ni parta agar solar sath na ho tu
Sir many single phase sa 3 phase motor chali ha invt vfd sa wapda shairing bhi hogai ha lakin sirf wapda pa motor thori si slow chal rahi ha
Apka cntct nbr brother?
Kch information chahye the
Slam sir
Ap ne single fase se there fase motr kyase chla li?
Invt vfd ka through chali ha
Bhai chf 100 or ed 600 ko malom Karne ka trica
Uspy likha hota hy model
Sir rst ko change krne se chakar change nhi hute ham ne bhut dafa Koshish ki nhi hute seting se chakar change kr skte hen
Assalamu alaikum bhai jaan RST mein se Kisi do ko change karna padta hai aap teenon ko change kar rahe honge isiliye chakar change Nahin ho rahe honge aap r ko serf s sy change kr den
Assalam o alehukam.
Shah g mainy wapda k thee phase connection vfd ko dy kr or pb 05 ki setting ko 00.00 kr dia phr Jb chalaya to masla yeh ha k motor sara load wapda sy lati ha solar sy bulkul nahi lati. Iski kya wajah ha.
Vfd chf-100 ha.
Plz lazmi jawab dy kr rehnumai krye ga.
03075253678
Rabta kren whatapp py
Sar wadpa aur solar per jo hai na vah chakkar ek hi rahte the vah change Nahin hote Hain
Bhai jaan Jo ab new vfd a rahi hai in my auto detect hai lekin jo purani vfd thi UN mein auto detect nahin tha hamari khud ki ek vfd kharab ho gai thi usko humne pahle solar per chalaya hua tha FIR humne solar ko band Karke wapda se chalaya FIR humne donon ko mix Kiya to vfd mein dhamaka ho Gaya FIR humne use bande se rabta Kiya tha jisse humne vfd li thi fir usne hamen bataya ki aapane solar band karne ke bad wapda se motor Chala kar Uske RPM check karne the ke chakkar sidhe Hain ya ulte agar sidhe hote to tab jakar aapane solar mix karna tha aapane direct solar aur wapda comics Kiya hai jiski vajah se program confuse ho gaya hai.
Sir pb o5 oo ho to wapda ka ilawa too ni chalay ga
Je pb 05 00 ho tu wapda k ilawa ni chaly gi bilkul
سر یہ برج کیا ہوتا ہے
Bridge dc KO ac m convert kerny k liye lagaya jata hai
Pb05 50HZ sy oper ni hoty bhai jan ap 80 bol rahy hu
Je je Bhai bilkul apne theek Kaha pb05 50hz sy oper NI hota reset mein.
Lakin agar ap frequency KO 60hz py fix kren Tu fir 60hz tak jata hy .
Bilkul ferfect hy apki bat
🐪🐪🐪🐪🐪🐪
Bhai hamare pass 2 phase wapada ka ha agr hm 2phase wapada se solar band kr k wapada pr tube well chalaye tu vfd me konse setting
hoge bhai zaroor as ka vedio banay
Bhai wapda par chalany k lye vfd ko 3 phase ke zrorrat hoti hy singal phase py ni chal sakta.
Han agar vfd sy pehy suply lga do tu fir ban jae ga.
@@shujabadi191 Bhai wapada ka 2 phases pr tu chala rhe ha
@@shujabadi191 Bhai pehy supply Kia ha
اگر واپڈہ کنیکشن سنگل فیز ہو تو کیا واپڈہ اور سولر کو مکس کیا جا سکتا ہے ؟
جی جی سنگل فیز کو مکس کرنے کیلئے vfd کو واپڈا دینے سے پہلے ایک سپلائی لگانی پڑتی ہے جو آپ کے سنگل فیز کنکشن کو تہری فیز میں تبدیل کرتی ہے۔اگر آپ کو وہ سپلائی ضرورت ہو تو آپ مجھ سے رابتہ کر سکتے ہیں۔
Sar supply kitne Ki Hai
@@shujabadi191supply single ko 3 phase kitnai ke mil jai ge
Bhai chf 100 ed model ko malom Karne ka trica
@@ahsanulhaqawanahsanulhaqaw24976:34
سینگل فیز بجلی دے سکتا ہے
جی جی
لیکن کامیاب نہیں ہے سنگل فیز پر
@@shujabadi191agar 2phase available hu
میری دوکان خراد والی ہے میں vfd لگو یا inviter لگاو
بھائی جان پائدار چیز تو وی ایف ڈی لیکن اس کے لیے اپ کو موٹر چینج کرنی پڑے گی کیونکہ خراد مشین پر عموما سنگل فیز موٹر لگی ہوتی ہے جو کہ وی ایف ڈی سے نہیں چل سکتی کیونکہ وی ایف ڈی تھری فیز ہوتی ہے اس لیے اپ کو اپنی موٹر پہلے تھری فیز کرنی پڑے گی چاہے اپ اسی موٹر کو تھری فیز کروائیں یا اس کو پیج کر تھری فیز موٹر لے لیں اگر اپ اسی موٹر کو تھری فیز کروائیں گے تو اپ کی دو ہس پاور کی موٹر جب تھری فیز ہوگی تو وہ تین ساڑھے تین حاس پاور کی بن جاتی ہے یا اپ اس کو بیچ کے تھری فیز موٹر لیں تو تین ہارس پاور کی تھری فیز موٹر بھی 20 سے 30 ہزار روپے کے درمیان مارکیٹ میں اپ کو مل جاتی ہے انورٹر جو ہے چاہے گھر میں بھی اج کل لگ رہے ہیں وہ کوئی اتنی پائیدار چیز نہیں ہے بہت جلد خراب ہو جاتے ہیں دوسرا انورٹر ٹارک بھی برداشت نہیں کرتا جب خراد مشین کی موٹر اپ سٹارٹ کرتے ہیں تو اس کا ٹارک جو ہے دو ہارس پاور کی موٹر کا کم از کم 40 ایمپیئر ہوتا ہے اس کے لیے انورٹر اپ کو کافی بڑا لگانا پڑے گا اس لیے بہتر یہی ہے اپ موٹر کو تھری فیز کر کے وی ایف ڈی لگا لیں شکریہ اللہ حافظ
السلام علیکم بھائی صاحب اب تھوڑا سا غلطی کر گئے ہیں جب ادھر سے اے سی دیتے ہیں تو اگے یہ بھی ڈی سی بنتی ہے اور پلیٹوں کی بھی ڈی سی بنتی ہے جو چکر اے سی پہ ہوں گے وہ سولر پہ بھی وہی چکر ہوں گے چکر الٹ نہیں ہوتے کبھی بھی یہ تھوڑی سی اپ کی مسٹیک ہے پلیز ذرا اپ یہ چیک کریں میں نے جو کہا ہے وہ صحیح کہا ہے یا غلط کا ہے
وعلیکم السلام جی بھائی اپ کی بات بھی ٹھیک ہے لیکن اصل میں مسئلہ یہ ہے کہ وی ایف ڈی کے اندر جو سافٹ ویئر ہوتا ہے اس کو وقت کے ساتھ ساتھ انجینئر لوگ اپڈیٹ کر رہے ہیں کچھ وی ایف ڈیز جو پہلے سے مارکیٹ میں موجود ہیں یعنی پرانی وی ایف ڈیز ان کا ان کا جو سافٹ ویئر تھا اس میں وی ایف ڈی اٹومیٹک ترتیب درست نہیں کر سکتی تھی جس کی وجہ سے عموما ہوتا یہی تھا کہ جب ہم سولر سے چکر سیدھے کر کے موٹر کو چلاتے تھے اس کے بعد واپڈا کے کنکشن دے کر ہم دونوں کو مکس کرتے تھے تو جو پرانی وی ایف ڈی ایم ہے اس کی بات کر رہا ہوں جس کا سافٹ ویئر پرانا ہے تو وہ دھماکے کی طرح پھٹتی تھی اگر اس کے چکر واپڈا کے اور ہوتے تھے اسی لیے میں نے ویڈیو میں یہ سمجھانے کی کوشش کی ہے کہ اگر کوئی دوست جس کے پاس پرانی وی ایف ڈی بھی ہو وہ بھی اور جس کے پاس نئی ہو وہ بھی وابڈا اور سولر کو مکس کرتے وقت کسی بھی بڑے حادثے سے بچ سکے ورنہ اپ کی بات بھی ٹھیک ہے جو نیو سافٹ ویئر ہے اس میں وی ایف ڈی خود بخود سیکونس درست کر سکتی ہے لیکن وہ بھی کچھ ماڈلز ایسے ہیں جن میں ڈیٹیکشن سسٹم نہیں ہے لہذا محتاط رہنا چاہیے
❤ good ❤
ویڈیو بنانے کا شوق ہو تو پہلے سیکھ بھی لیا کرو RPM الٹے سیدھے کرنے پر آپ نے غلط بتایا ہے اس سے کسی کا نقصان ہو گا
Sorry apne ghalat bola h
Sir your no