Sir, Please tell how to measure Staging measurement. Wheatger we will give staging measurement for both 1.Concrete 2.Reinforcement. Or one time it's enough..
Dear Sir.. In the Case form work Opening upto 0.4 SQM is not deducted.. But in the Case of Opening if Column Cross section more than 0.4 SQM is deducted or not .. Opening is not mentioned ... My Client deducted opening of Colum from Slab Shuttering... Please Guide
In shuttering Labour bill Tie rod measurement? 1.In RC wall both inner and outer tie rod fixed. One plywood - 8Tie rods connected. How many nos we will give measurement 8 nos or 16 Nos
मेरा दो सवाल है, 1॥डबल height shuttering me सिर्फ कॉलम की height क्लेम होती है या और भी कुछ. 2.agar slab का thickness 200mm से ज़्यादा है तो एक्सट्रा item के तौर पे हम क्या क्लेम कर सकते हैं
Sir mera 1 sawal he ki mera water tank kam chalo he 12mm ka steel he 150c/c he jo niche me lag gaya he upper lep karna to khatam hogaya he but mere pass only 8 mm ka steel he to me ushka lep ketna c/c karo kg b mech karna he steel ka ye wall k leye poch raha hu PL answer jaror dena sir.
Sir ydi secondry beam m aakr koi dusri secondry beam judti hai.. To us conditions m seondry beam ki side se jo beam ka jo cutout area bnta hai... Vo minus hoga ya nhi... Reply plz...
sir edges of slab jo hoti h usko running metre may measure krtay h ki ni . sir generally shuttering square metre may krtay h pr kaha kaha pr running metre may krtay h . plz reply me.
Shafat Ali All kind of shuttering / form work measured in sqm as per IS Code, and Only touch of concrete area measured for payment in footing, column, slab, beam etc.
According to IS 875 Part 1 ( Page No. 16) density of plywood should be 700kg / cum minimim, used for construction works, also you can watch my video Density of Building Material
Good morning sir, sir IS1200 part 5 k page no 7 pr (m) serial no h usmay jo likha h edges of slab and breaks in floor and walls . sir yeah point smja diyay muje.
Yes you are right End edges of slabs / balcony are measured in running meters upto 200mm thickness, but practically end of edges merged in outer side of beamand most of BOQ items of measured in sqm due to various thikness of slabs,
Sir ye ab bhi clr nhi hua ho ske to ek sketch bna kr dal dijiyegaa... Ki end edge kaise running meter m nape... Kyoki hm to balcony slav ko bhi area m napte hai
In case we claim shuttering extra for height more than 3.5 mtr. Can you let me know how to claim for height of 6 mtrs. Plan area can be considered 100 sq mtrs. Please do reply
Dear Ram, Scaffolding measured in two types Sqm OR Cum, as 1. paint, plaster, masonry, vertical surface works in Sqm and 2. Under shuttering case for slab supports in cum
If any questions, please comment below.
Sir hieght wali bat code m nhi h
Sir column ki shuttering kis height tak ayegi?
sir when we take measurements in running meter.if its less than 200 mm or 150 mm
Single layer scaffolding ER schedule rate Kaya ha..
Is 100 mm Pcc shuttering payable?
Good Work Sir... keep posting such informative videos
Sir column ki shuttering slab bottom tak consider karenge ?
Bhai pasand nhi bhot pasand aai aap ki video
Thanks
Very knowledgeable video thanks a lot
Sir,
One doubt
In over head tank
RC wall inner side another wall continues then inner side shuttering shall we deduct or not..
Is PCC shuttering quantity to be consider in billing as per IS 1200?
Very knowledgeable video
Sir,
Please tell how to measure Staging measurement.
Wheatger we will give staging measurement for both
1.Concrete
2.Reinforcement.
Or one time it's enough..
Sir Rcc slab me kaun kaun s openings area and kain Kaun s duct deduct hota hai contractor k Area nikal kr bill dene ko sir...
Dear Sir..
In the Case form work
Opening upto 0.4 SQM is not deducted..
But in the Case of Opening if Column Cross section more than 0.4 SQM is deducted or not ..
Opening is not mentioned ...
My Client deducted opening of Colum from Slab Shuttering...
Please Guide
column cross section area will be deduction from the slab area its site rules (ultra tech cement Ltd Tadipatri, APCW line project)
Amazing video sir
Ek cover area billing video banaye sir
In shuttering
Labour bill
Tie rod measurement?
1.In RC wall both inner and outer tie rod fixed.
One plywood - 8Tie rods connected.
How many nos we will give measurement
8 nos or 16 Nos
8
Nice sir
Thanks
Factual knowledge ....good one
Nice
Great
sir,
plz suggest me which book is best for QS and Billing engineer which book can use by experienced person.
मेरा दो सवाल है,
1॥डबल height shuttering me सिर्फ कॉलम की height क्लेम होती है या और भी कुछ.
2.agar slab का thickness 200mm से ज़्यादा है तो एक्सट्रा item के तौर पे हम क्या क्लेम कर सकते हैं
Sir can we take shuttering qty for PCC side face?
Sir Billing Engineer k liye koi course launch kijiyega Plz.. Sir How i can contact you
Sir mera 1 sawal he ki mera water tank kam chalo he 12mm ka steel he 150c/c he jo niche me lag gaya he upper lep karna to khatam hogaya he but mere pass only 8 mm ka steel he to me ushka lep ketna c/c karo kg b mech karna he steel ka ye wall k leye poch raha hu PL answer jaror dena sir.
Sir if I take slab area for shuttering,if columns opening area less than 0.4 m2 ,there will be no deduction for column area sir
Yes you are right.
spacing between two props under the beam and slab both.
Kya slab thickness deduct hoga? In case of inner side column shuttering. IS code m yeh baat nhi di hui hai. Pls reply.
Di hui h, column should be measured upto bottom of slab
@@FactualCivilEngineering Thanks Sir. Also explain reason behind that.
Sir ydi secondry beam m aakr koi dusri secondry beam judti hai.. To us conditions m seondry beam ki side se jo beam ka jo cutout area bnta hai... Vo minus hoga ya nhi... Reply plz...
Ek main minus hoga
Very good
th-cam.com/video/go78MA158yQ/w-d-xo.html
Agar column ka size 2.0 m ka hai or Beam ka size 1.0m X 1.5m hai to kya deduction nahi hoga
Dear,
I need bs and us standards.
Also Redbook and Fidic.
Regards
Alphyn P
What is height of column taken in formwork if slab height floor to floor 3.6 m and slab thickness is 0.15m.
Sir
Edge of slab and breaks in floor and wall ki measurement kaise lenge.
sir edges of slab jo hoti h usko running metre may measure krtay h ki ni . sir generally shuttering square metre may krtay h pr kaha kaha pr running metre may krtay h . plz reply me.
Shafat Ali All kind of shuttering / form work measured in sqm as per IS Code, and Only touch of concrete area measured for payment in footing, column, slab, beam etc.
sir BOQ may diya h usmay muje 1 doubt h.
If it is described in BOQ item than we meaured in running meters,
Sir 3mm thick polycarbonate sheet ka rate analysis karna hai DAR me nhi mil raha labour and material ka sheet ka price 70 rs per sqft hai
Ok, i will prepare for it
@@FactualCivilEngineering thanku sir
Sir maine apko mail kiya tha kal cash flow ki sheet ke liye sir mail kardenge to help ho jayegi meri thodi
🙏 🇮🇳 👍 😍
sir 1200 k aur Bhi part upload kryay. plz
Please send your mail id, i will send you SP27 book for all IS 1200
@@FactualCivilEngineering pls s nd me SP 27
Sir column waala point fir se samjha dijiye
Is there any mode of measurements for solids concrete block work
Shahul Hameed its depend on work order BOQ Item, generally its measured in sqm for 100mm & 200mm thick block works
@@FactualCivilEngineering sometimes it is only measured in sqmt for 100mm and more than that can be measured in M3.
sir apnay antitermite aur backfilling ka video ni upload kiya.
Main aur secondary beam wala agar dimension consider krke smjhate toh aur jyada clear hota, smjh mei aaya hi nahi.
Main beam
length 5m width 0.3
Secondary beam
Length 4m width 0.3
Then
Shuttering will be
5*0.3=1.5 sqm
4*0.3=1.2 sqm
Cutout wala smjh nhi aaya
Please uplaod all parts
Sir extra iteam ke lie konsa is code kahta
Sir ht wali line to code m h hi nho
Arch का shuttering and concrete Qty का फॉर्मूला क्या है
Sir plywood ka density kya hota hai..
According to IS 875 Part 1 ( Page No. 16) density of plywood should be 700kg / cum minimim, used for construction works, also you can watch my video Density of Building Material
Good morning sir, sir IS1200 part 5 k page no 7 pr (m) serial no h usmay jo likha h edges of slab and breaks in floor and walls . sir yeah point smja diyay muje.
Yes you are right End edges of slabs / balcony are measured in running meters upto 200mm thickness, but practically end of edges merged in outer side of beamand most of BOQ items of measured in sqm due to various thikness of slabs,
Sir ye ab bhi clr nhi hua ho ske to ek sketch bna kr dal dijiyegaa... Ki end edge kaise running meter m nape... Kyoki hm to balcony slav ko bhi area m napte hai
Dear Mayank, its only horizontal for slab fins case
In case we claim shuttering extra for height more than 3.5 mtr. Can you let me know how to claim for height of 6 mtrs. Plan area can be considered 100 sq mtrs. Please do reply
6 - 3.5 = 2.5 mean 3 times of plan area (3 x 100 Sqm) for a seperate rate of extra height for per metre height
गोल calumn की shuttering निकलने का फॉर्मूला क्या है
Kindly tell me scaffolding measurement
Dear Ram, Scaffolding measured in two types Sqm OR Cum, as 1. paint, plaster, masonry, vertical surface works in Sqm and 2. Under shuttering case for slab supports in cum
@@FactualCivilEngineering I tnk cum not come.
=(L+b)*h
Like this come this also comes under sqm
Sir ye hieght wali bat to code m h hi nhi
Thanks