ID, AR, NCS PART 2 IGEM G 11 QUIZ, Gas unsafe situations procedure what gas engineers need to know

แชร์
ฝัง
  • เผยแพร่เมื่อ 26 ธ.ค. 2024

ความคิดเห็น •

  • @tomkatgastraining
    @tomkatgastraining  3 ปีที่แล้ว +1

    th-cam.com/video/SaZUY4fh10M/w-d-xo.html
    Link for part 1 if you haven’t seen it 👍🏻

  • @prsheating
    @prsheating 3 ปีที่แล้ว +1

    Excellent very helpful mate...been a Gas engineer for over 35 years...your ironing out these grey areas.

  • @Tony-sr7vq
    @Tony-sr7vq ปีที่แล้ว

    Hi Derek just like to say a big thank you for all your time that you do it is a big help. Thank you

  • @Neutron66
    @Neutron66 2 ปีที่แล้ว +1

    Ever since PME (protective multiple earthing or TNC-S) was utilised in the 80's, the risk of elevated voltages on different exposed conductive parts has increased. It is for this reason equipotential bonding is necessary. Neutral and Earth a marshalled together at the meter position (as well as the substation) and therefore the installation earth potential (that being the same as the neutral ) can be a number of volts different to true earth potential.

  • @patrickoregan7102
    @patrickoregan7102 2 ปีที่แล้ว +1

    Great videos,thanks Derek , a big help with up and coming ACS 👍

  • @williamhoughton1484
    @williamhoughton1484 2 ปีที่แล้ว

    Well done Derek , Keep them coming . It brings me up to speed!🤪

  • @mohammednadeem7274
    @mohammednadeem7274 3 ปีที่แล้ว +1

    Excellent video Derek on these unsafe situations. Its good to know what you will come across on jobs onsite. Thanks.👌👍👍😁😀

  • @aphroditenajad2603
    @aphroditenajad2603 2 ปีที่แล้ว

    Fantastic, Thank you, I love this questions and answer with explanations! Well done !

  • @pbernard6313
    @pbernard6313 5 หลายเดือนก่อน

    Thanks, very good teaching

  • @azimkhan9862
    @azimkhan9862 3 ปีที่แล้ว +1

    Fantastic video Derek, highly appreciated the best videos out there for unsafe situations are your videos part 1 and 2.
    Hopefully part 3 soon 😋

  • @wallmackari3885
    @wallmackari3885 2 ปีที่แล้ว

    the requirement of the equpotential bonding is clearly on the out let pipe from the meter , so I think it should be there to protect what ever inside the property regardless the inlet pipe or before the meter installation . if not there I think it should classify as AR and Not RIDDOR

  • @ryandow3954
    @ryandow3954 3 ปีที่แล้ว +1

    Really enjoying these videos 👍 keep them coming!

  • @msuk5957
    @msuk5957 2 ปีที่แล้ว

    Thank you Derek , Mohamed Hassan

  • @jerzyszczachor724
    @jerzyszczachor724 ปีที่แล้ว

    Interesting about bonding 18th edition amendment 2 dose not required bonding on incoming services to the building if they are plastic. However if no bonding on water mains any current leakage under ground could travel through water also so if no bonding current could be present on boiler body before travel through earthing from a spur but if you disconnected power supply and bonding the appliance body becomes live.
    Also there is a major issue where problem was found the nutreal on electricity supply become faulty the current found way through earthing path. So there was gas explosions cause by that and they found fault where on gas pipe 35A has been recorded .

  • @monikanader9454
    @monikanader9454 3 ปีที่แล้ว

    Great video, very informative. Thank you👍👍👍

  • @localtradesuk8572
    @localtradesuk8572 ปีที่แล้ว

    Hi Derek great videos, Can you make more videos like this as it does help. I got a questions does fly screen on a vent does that reduce air so you need a bigger vent or no? thanks

    • @tomkatgastraining
      @tomkatgastraining  ปีที่แล้ว

      No you can’t use a vent with a fly screen because it can get blocked by insects and spiders webs.

  • @paigedarby4997
    @paigedarby4997 2 ปีที่แล้ว +1

    Hi Derek
    Great videos. Would you be able to do more videos on Unsafe Situations and how to best classify them. Are there any techniques to better identify them or is it just literally a case of keep practicing and revising? I did well in this video but struggled on part 1. Any help would be great on how to best revise. Thanks for all your other video as they've helped loads.

  • @AnEyeScream
    @AnEyeScream 2 ปีที่แล้ว

    Thank you, Nikola Ditsov

  • @rayc1503
    @rayc1503 3 ปีที่แล้ว +1

    Strange IET electrical regulations state that if there aren't any extraneous conductive parts on the incoming mains and the incoming underground pipe is of non conductive material then no equpotential bonding is required. However according to BS 7671 regulations differ stating PEB must be fitted within 600 mm and before the first T branch in pipework. I can't understand why regulations differ through both industries. I'm completely for the installation of PEB however other electricians would argue that IET regs differ 🤷‍♂️.
    If on the Ecv there's a red ring present this indicates no PEB required. If there's no red ring downstream of the ECV then install a PEB clamp. It should be just below the ECV in any case.

  • @kelvinjones1995
    @kelvinjones1995 3 ปีที่แล้ว

    👍 Always something to learn from the Guru 😎

  • @saltnvinni1
    @saltnvinni1 3 ปีที่แล้ว

    Fantastic video

  • @martynlewis5901
    @martynlewis5901 3 ปีที่แล้ว

    Excellent, thanks. ACS due next year so this is all good prep. 👍🏻

  • @hussaingonoo959
    @hussaingonoo959 3 ปีที่แล้ว

    Another fantastic Video

  • @vahidkaregar8049
    @vahidkaregar8049 3 ปีที่แล้ว

    Brilliant, really informative , please keep them coming🙏

  • @hazelbulgin638
    @hazelbulgin638 3 ปีที่แล้ว

    Brilliant keep them coming 👏👍🏾

  • @stevehouse3904
    @stevehouse3904 2 ปีที่แล้ว

    GSIUR REG 7(1), PIPEWORK SUITABLE FOR GAS BEING USED IN AN INAPPROPRIATE LOCATION, would that include being less the 25mm from light switch?

  • @mj0n4id36
    @mj0n4id36 3 ปีที่แล้ว

    Brilliant video. I did better in this one than I did in part 1 😎. At 14:15 when talking about the flueless space heater and how it should be at least 1 metre away from a vent, how about a door? I saw this type of flueless space heater installed in a hallway not to far away from the main door to the house. What are the requirements for that? Thanks Derek. Much appreciated 👍🏻
    Asian Jon. Training.

    • @tomkatgastraining
      @tomkatgastraining  3 ปีที่แล้ว +2

      The door is not that much of a problem because it’s closed most of the time and it’s a big area. The ventilation being too close is a problem because it could stop the ASD shutting down and make the room vitiated.

  • @hamzaparvais3948
    @hamzaparvais3948 2 ปีที่แล้ว

    Brilliant thank really good mate

  • @leaturk11
    @leaturk11 3 ปีที่แล้ว

    Great stuff, keep them coming.

  • @aghasahib4703
    @aghasahib4703 3 ปีที่แล้ว

    Brilliant video. Thanks alot mate

  • @louisdisbury9759
    @louisdisbury9759 2 หลายเดือนก่อน

    Hi Derek regarding earth bonding on gas meters if its a propathene gas service coming in that will not act as an earth conductor but regardless the earth bonding on the gas meter is 10mm goes back to the Earth block on the consumer unit and will offer protection if gas appliances go to earth and incidentally RCD s will not operate if you do not have good earth, regarding flueless gas fires an engineer fitted one about ten years ago and never checked the operating pressure which was double what it should have been, The oxy pilot failed to operate because an air vent fitted close to the appliance fed fresh air to the pilot the result was the death of an 18-year-old girl and her dog overcome by monoxide fumes due to incorrect operating pressure the Installer was sentenced to 3 years in jail I think the minimum distance for ventilation to a flueless gas fire is 1 metre from the appliance but after learning about that Incedent my company no longer fits them.

  • @thomasblades4059
    @thomasblades4059 3 ปีที่แล้ว

    Top video

  • @jpfrench1496
    @jpfrench1496 3 ปีที่แล้ว

    Another great vid

  • @mdillon1976
    @mdillon1976 3 ปีที่แล้ว

    8 00 phone gas board 🤣🤣got one wrong derek cheers 👍

  • @abchannel3737
    @abchannel3737 3 ปีที่แล้ว

    Your are the best 🌹👍👌✌️

  • @timeintheuk
    @timeintheuk ปีที่แล้ว

    Helpfull ta

  • @lazylady81
    @lazylady81 3 ปีที่แล้ว

    so paint on a flue or boiler is AR?

  • @suewarrington8155
    @suewarrington8155 2 ปีที่แล้ว

    👍Sue Warrington

  • @marcinmasalski4183
    @marcinmasalski4183 3 ปีที่แล้ว

    Marcin Masalski 👍

  • @leaturk11
    @leaturk11 3 ปีที่แล้ว +3

    The meter had a open uncapped pipe, so I marked it as ID

    • @tomkatgastraining
      @tomkatgastraining  3 ปีที่แล้ว +1

      The question was about the meter being inside the property not the open end 😜

  • @M20DAN
    @M20DAN 2 ปีที่แล้ว

    tomkat👍

  • @joaovittoria2533
    @joaovittoria2533 3 ปีที่แล้ว

    👍👍

  • @SuperWayneyb
    @SuperWayneyb 3 ปีที่แล้ว

    🤘🤓🤘

  • @carlhutchinson3458
    @carlhutchinson3458 3 ปีที่แล้ว

    Medium pressure gas meter has an open end on outlet 🤔 is that no ID? 🤔

    • @tomkatgastraining
      @tomkatgastraining  3 ปีที่แล้ว +1

      The scenario was the medium pressure meter was installed inside not the open end that’s why I gave scenarios not just said what’s wrong but yes an open end is ID

  • @bryanwilliams3827
    @bryanwilliams3827 2 ปีที่แล้ว

    Bryan Williams

  • @andyjones7836
    @andyjones7836 3 ปีที่แล้ว

    👍

  • @viran8121
    @viran8121 3 ปีที่แล้ว

    👍🏽

  • @richardhodgson7443
    @richardhodgson7443 3 ปีที่แล้ว

    Great video again Derek, brilliant for revision. Would you mind being the first person to actually demonstrate / show the procedure of unsafe situations practically. Ie actually disconnecting appliance, capping off meter, etc. Thanks 🙏

  • @craighurst3599
    @craighurst3599 3 ปีที่แล้ว

    CH👍

  • @jon-paulward4580
    @jon-paulward4580 2 ปีที่แล้ว

    Jon-Paul Ward

  • @stephenhumphreys4099
    @stephenhumphreys4099 2 ปีที่แล้ว

    Stephen Humphreys

  • @mustafaakbari6231
    @mustafaakbari6231 2 ปีที่แล้ว

    Mustafa akbari

  • @danielcarragher6628
    @danielcarragher6628 3 ปีที่แล้ว

    Daniel carragher

  • @danielriglin9333
    @danielriglin9333 2 ปีที่แล้ว

    Dan Riglin

  • @stevehouse3904
    @stevehouse3904 2 ปีที่แล้ว

    I meant socket!

  • @steve250276
    @steve250276 2 ปีที่แล้ว

    steve ward

  • @secondchance4498
    @secondchance4498 3 ปีที่แล้ว

    ChrisTaylor

  • @mattrowntree3359
    @mattrowntree3359 ปีที่แล้ว

    15 Min into vid the gas meter has open end and you've classed it as ar and not Id 😮... the medium pressure one ..

    • @tomkatgastraining
      @tomkatgastraining  ปีที่แล้ว

      The question was about medium pressure inside a property not about an open end on a gas pipe. I said at the beginning of this section it represents not this is what you find so a medium pressure meter inside a property is AR. For your information there is a disk in the meter outlet also so still no open end.

  • @BrothersGrim2012
    @BrothersGrim2012 3 ปีที่แล้ว

    No Bonding

    • @tomkatgastraining
      @tomkatgastraining  3 ปีที่แล้ว

      Is that nor ID and riddor then

    • @BrothersGrim2012
      @BrothersGrim2012 3 ปีที่แล้ว

      @@tomkatgastraining no Earth bonding i would make a note on the cert, advise the customer to get a qualified electrician to get it done for them

    • @tomkatgastraining
      @tomkatgastraining  3 ปีที่แล้ว

      @@BrothersGrim2012 don’t you mean leave a bonding notice at the gas meter to advise the responsible person earth bonding could be required

    • @BrothersGrim2012
      @BrothersGrim2012 3 ปีที่แล้ว

      @@tomkatgastraining I’m only learning so far so just had a go without looking in book, if I’d of referred to book then I would of have a fuller answer

    • @tomkatgastraining
      @tomkatgastraining  3 ปีที่แล้ว

      @@BrothersGrim2012 a lot more training required joe but keep it up 👍🏻

  • @warmastermoran6418
    @warmastermoran6418 3 ปีที่แล้ว

    JD Moran-Campbell. Training

  • @chrisjones4500
    @chrisjones4500 2 ปีที่แล้ว

    👍👍

  • @lewisclarke4765
    @lewisclarke4765 2 ปีที่แล้ว

    👍🏻