HVAC PM Training Video

แชร์
ฝัง

ความคิดเห็น • 143

  • @Miketec81
    @Miketec81 4 ปีที่แล้ว +48

    Funny how everyone talking bout what he should had done or should not do when In the midst of summer y’all probably don’t even do a quarter of that

    • @nathannutt1743
      @nathannutt1743 4 ปีที่แล้ว

      I would

    • @samiayyat4826
      @samiayyat4826  4 ปีที่แล้ว +10

      Sorry for the late reply, but I completely agree. its easy to be a know it all, but not anyone knows it all.

    • @chriswhalen5711
      @chriswhalen5711 3 ปีที่แล้ว +9

      Your forgetting crap boss always trying to rush it. “ I want a 3hr job done in 15min” lol

    • @moeselec
      @moeselec 3 ปีที่แล้ว +4

      @@chriswhalen5711 Yes sir , They want you do all the of that and you have to up sale .

    • @Hvacmania
      @Hvacmania ปีที่แล้ว +1

      Maintenance should pretty much just be washing the coils checking caps , contactor , belt , drain , loose connects , changing filters. Anything else is a service call

  • @goofy3908
    @goofy3908 5 ปีที่แล้ว +23

    thank you for an organized step by step pm check. Im actually gonna write down the sequence. Nice job

  • @JB-yq9bn
    @JB-yq9bn ปีที่แล้ว +3

    For demonstrating the value of your service I recommending greetings 1st doing the maintenance and taking readings after so you can show the improvement that the maintenance has created for the customer. Creating value oftentimes means you can charge more. It also helps to reduce resistance when you make recommendations that the customer will have to pay for. They've seen a track record of what you are doing and the improvements you are making. It also helps you to understand what are the items that will get you the best result for the customer so if you have to give them a budget option you can get the biggest Bang for the buck

  • @ianagar805
    @ianagar805 4 ปีที่แล้ว +8

    tech trades show how smart a person can be. i love it!

  • @Kissfann77
    @Kissfann77 4 ปีที่แล้ว

    Great video very detailed on the preventative maintenance

  • @djish3223
    @djish3223 ปีที่แล้ว

    I f****** love this video. Thank you dude I'm a rookie technician inland Empire California.

  • @mariobryant8803
    @mariobryant8803 4 ปีที่แล้ว +11

    Definitely awesome explanation in the steps of doing maintenance on an air conditioning unit

  • @IIUzzymanII
    @IIUzzymanII 4 ปีที่แล้ว +9

    Man, you should check a drain regardless. I've been to way too many homes where the drain is clogged and the pan is perfectly clean. You have a hose right there, go through the breather on the u-joint! If it's a heat pump just uncap and go from there. Wont hurt a fly and doesn't take any time at all. Could save thousands and thousands in damages just from checking a drain properly.

  • @Timothyapollo220
    @Timothyapollo220 4 ปีที่แล้ว +8

    This was very helpful, good job 👍🏽

  • @TATerry
    @TATerry 27 วันที่ผ่านมา

    Nice video, I’m in school for HVAC. Looking forward to doing commercial work one day

  • @jakehartung3655
    @jakehartung3655 3 ปีที่แล้ว

    Solid video, very informative.

  • @matthewrodriguez4787
    @matthewrodriguez4787 2 ปีที่แล้ว +4

    Thanks for the info man , I’m a new tech here fresh out of school and new to the commercial side so I’m new to all this . Your been a big help .

    • @EastDallasKicks
      @EastDallasKicks ปีที่แล้ว

      How you doing in commercial? Those controls look scary af

    • @jonnygang5838
      @jonnygang5838 ปีที่แล้ว

      I graduated school struggled to find a job and 2 years later finally found a job in commercial HvacR and Tommarow I am bout to start pms

  • @1515alaro
    @1515alaro 4 ปีที่แล้ว +1

    Great video!! Thank you for sharing !!

  • @dougjones4987
    @dougjones4987 2 ปีที่แล้ว +1

    Thanks,great video-just what i was looking for

  • @tthack84
    @tthack84 4 ปีที่แล้ว +20

    Good video. I will give you a Pro tip, NEVER stand in front of a disconnect while energizing or de-energizing a disconnect. Always off to the side while facing away.

    • @user-vb8jl6nf4k
      @user-vb8jl6nf4k 4 ปีที่แล้ว +1

      Compensation totally agree I’ve burned once

    • @samiayyat4826
      @samiayyat4826  4 ปีที่แล้ว +5

      Thanks for the tip, so many things to cover it is easy to miss some detail. hell, if we can get guys just to pull out the hose and wash coils we have achieved total success. lol

    • @49ersempirefaithful7
      @49ersempirefaithful7 3 ปีที่แล้ว

      Facts

    • @Hvacmania
      @Hvacmania ปีที่แล้ว

      Why off to the side and facing away ? In case it blows up ?

    • @tthack84
      @tthack84 ปีที่แล้ว

      @@Hvacmania yeah, the arc flash will blow outwards when it blows the door off. There are some videos floating around showing it. But be careful what you watch as some were incidents with people involved who didn't make it. I think there is a 20 amp service disconnect that they tested on a dummy so look for that.

  • @brettlafleur27
    @brettlafleur27 2 ปีที่แล้ว

    Love this man, good job.

  • @Brownbutterbabii
    @Brownbutterbabii 3 ปีที่แล้ว +1

    great video the will help me as a tech

  • @g_dub
    @g_dub 3 ปีที่แล้ว

    Fools a straight up G, thanks for the help brother 🙏

  • @MrRalph438
    @MrRalph438 3 ปีที่แล้ว

    Good stuff! Very professional. subscribed.

  • @Kissfann77
    @Kissfann77 3 ปีที่แล้ว

    Great video very detailed 👍🏼

  • @YourActualMother
    @YourActualMother 4 ปีที่แล้ว

    awesome video! best video on youtube

  • @jorgearzeta4852
    @jorgearzeta4852 5 ปีที่แล้ว +7

    Keep uploading!!

  • @btrained8760
    @btrained8760 3 ปีที่แล้ว

    Great video!!
    Thanks Jason!

  • @Ishutyoudown323
    @Ishutyoudown323 3 ปีที่แล้ว

    Thank you for this video 🙏 I am 20 and will in a few months study for this career

  • @JuanMartinez-df1lc
    @JuanMartinez-df1lc หลายเดือนก่อน

    I’m going to start my first hvac job doing commercial residential. I even don’t apartment maintenance 14 years. We only had residential type hvac systems 2 ton. Any suggestions or tips starting to n field as a tech ? I would appreciate any advice. Really great videos by the way

  • @llamacebu216
    @llamacebu216 2 ปีที่แล้ว +2

    If you're new technician, stick with old school gauges over the smart probes. Smart probes are for EXPERIENCED techs. Only reason I'm typing this is bc all the responses to the probes. It's not a good choice for a beginner. Learn your pressures. Learn txv. Buy shutoff valves. You'll release hardly any refrigerant and it's equalivant to the probes, no difference. Be fast.
    You'll also have to send the probes in to get recalibrated and pay for it.

    • @MarkCarpenterHVAC-me2jg
      @MarkCarpenterHVAC-me2jg ปีที่แล้ว

      I don't agree that smart probes are only for the experienced techs. If your are truly interested in learning the trade, the learning curve is much faster with the newer equipment than the old.
      I can't even imagine going beck to a micron gauge that I couldn't plot on my phone. What a learning tool that is for a new tech to actually be able to see the difference in a leak and refrigerant or water gassing off in the system.
      Unlike analog gauges, smart probes allow the tech to easily think in saturated temperature rather than pressure from day one! That's priceless! New refrigrant comes along there's no difference in the saturated temperatures.
      How many new or old techs are going inside to sling a sling psychrometer, when charging a piston?
      The problem isn't the new technology! It's employer's that don't want to put any training into their employees. An apprentice needs a year or two following an older tech in the field and then support for a few years after that. If he can give me good measurement's over the phone we can walk through most any refrigerant problem. Then to top it all off the manufactures are cutting back on tech support at at time when their equipment is getting more and more complicated for new and old techs alike.
      Apps like MQ can give the newer tech confidence in their diagnosis, if it is used after they make an attempt at diagnosing the system first. If it doesn't agree then they need to dialup a senior tech and get advice .
      There's place for analog gauges like when diagnosing a TXV that is hunting or setting the cut in and cut out on a refrigeration system,. Other than that I don't really see the need for them.

  • @jeffgrant6914
    @jeffgrant6914 4 ปีที่แล้ว +1

    Nice training video 👍

  • @jeremyvega9749
    @jeremyvega9749 4 ปีที่แล้ว

    Overall good video 👌

  • @twotimes87
    @twotimes87 4 ปีที่แล้ว

    Great video

  • @tgram4894
    @tgram4894 หลายเดือนก่อน

    Good video. What about pressure reading , superheat , sub cooking ? How often do you take those?

  • @arjhanpardom2511
    @arjhanpardom2511 2 ปีที่แล้ว

    Can you leave a link so I can buy the thermometer that you used to check the temp on the return and vent?

  • @jakehartung3655
    @jakehartung3655 3 ปีที่แล้ว +1

    What kind of multi meter is that? I’d like to get the same one.

  • @vipleather
    @vipleather 5 ปีที่แล้ว +1

    Bravo!

  • @acservicedaytona386portora3
    @acservicedaytona386portora3 4 ปีที่แล้ว

    Good video...

  • @alicepet1994
    @alicepet1994 4 ปีที่แล้ว +7

    You should use Fieldpiece smart probes to do maintenance check since your LONG gauge hoses will remove a lot refrigerant from this system

    • @samiayyat4826
      @samiayyat4826  4 ปีที่แล้ว +2

      agree on the smart probes, i use Testo myself. for the average PM guy, it is difficult to purchase such a pricey tool, not many techs can afford it especially starting out. Often times they forget the fundamentals that is why we stick to mechanical gauges and PT charts.

    • @llamacebu216
      @llamacebu216 2 ปีที่แล้ว +1

      I find that false. Shut off fittings and you'll release hardly nothing. The only thing smart probes are good for is, time. For people starting off, especially doing PMs then you should learn the gauges first and the pressures. BecUse guages do things the APP won't tell you unless you're an EXPERIENCED Tech. TXV is a main reason for guages
      Here the other issue,
      You have to send them in to have it recalibrated. I can recalibrate my Brutes with my thermostat screwdriver. Guess what. I have all three pairs. When you second guess the probes you go back to ol trusty... So no, smart probes are not worth it and it's horrible advice to give to new people

    • @Hvacmania
      @Hvacmania ปีที่แล้ว +1

      Is there another way of checking the refrigerant charge without putting on the gauges? Like a temperature difference delta t type method?

  • @jamesaldrich9238
    @jamesaldrich9238 2 ปีที่แล้ว

    You should’ve release tension on the motor and retention after putting the belt on

  • @jordanmitchell6635
    @jordanmitchell6635 4 ปีที่แล้ว +1

    I liked the video and definitely worth while to do all these things on a pm as long as your company is allowing the time. However I dont think its worth while to put gauges on the system unless you suspect there is an issue with the cooling performance just cause always pull a small amount of refrigerant out of the system everytime you put them on, that will definitely cause a problem after a while especially if you do that every quarterly pm

    • @calvinwindsor4461
      @calvinwindsor4461 3 ปีที่แล้ว

      Always put refrigerant that’s in the hoses back in through suction side to prevent refrigerant loss. Or use pressure fishes with no hoses to check, this will prevent it also 👍

    • @CreativeMaintenanceSolutions
      @CreativeMaintenanceSolutions 2 ปีที่แล้ว

      Fieldpiece smart probes would fix this issue :) Or any type that does the same thing without hoses.

  • @nicholasnicholas9821
    @nicholasnicholas9821 3 ปีที่แล้ว +6

    I just started Hvac, there going to put me as a PM tech, I'm excited good pay

    • @samiayyat4826
      @samiayyat4826  3 ปีที่แล้ว +2

      its a great trade, you can never stop learning. Learn as much as possible, do good work and your reputation will carry you to a great career.

    • @whyYoustalking
      @whyYoustalking 3 ปีที่แล้ว

      Learn more = more overtime

    • @engelperez4641
      @engelperez4641 3 ปีที่แล้ว

      How long was the course?

    • @4oh4n0tf0und
      @4oh4n0tf0und 3 ปีที่แล้ว

      I'm also going to be starting in the trade of HVAC in a few weeks. How have you been doing so far?

    • @romane9548
      @romane9548 3 ปีที่แล้ว

      @@4oh4n0tf0und I start on on the 18th😝

  • @theaustinite5320
    @theaustinite5320 2 ปีที่แล้ว

    Thanks for the video, how often you need to do the PM ?
    Thanks

  • @Bhakto_ke_Jijaji
    @Bhakto_ke_Jijaji 4 ปีที่แล้ว

    Good job

  • @49ersempirefaithful7
    @49ersempirefaithful7 3 ปีที่แล้ว

    Why gauge up on pm u can check by coil temp supply an return temp threw heating Nd cooling with splits

  • @brotherjoeradosti
    @brotherjoeradosti 2 ปีที่แล้ว

    That's a thorough exam!

  • @hashtagrossi_beats3444
    @hashtagrossi_beats3444 2 ปีที่แล้ว

    Great example.

  • @05genim
    @05genim 2 ปีที่แล้ว

    Amazing

  • @user-mz5kj4xi2d
    @user-mz5kj4xi2d 3 หลายเดือนก่อน

    How much usually costs maintenance of the same unit for customers?

  • @sajidmehmood2913
    @sajidmehmood2913 2 ปีที่แล้ว

    Very good

  • @PBS-nm1uu
    @PBS-nm1uu 4 ปีที่แล้ว +1

    this would have been a great presentation if the camera angle was right.

  • @punkisinthedetails1470
    @punkisinthedetails1470 3 ปีที่แล้ว +1

    Artic as in articulated like a truck or arctic as in cooool af

  • @Weird_1
    @Weird_1 ปีที่แล้ว

    Nice work. Not that I do it personally but a lot of belt companies and engineers recommend not rolling the belts on or off due it allegedly tearing fibers. My work changes filters and belts every quarter no matter the condition so it’s not as big of a deal to us. Nice video

  • @gercio2782
    @gercio2782 5 ปีที่แล้ว

    nice!

  • @jonathanallen5603
    @jonathanallen5603 3 ปีที่แล้ว

    I recognized the gloves smart move

  • @cpaul57
    @cpaul57 4 ปีที่แล้ว +3

    My old company wanted blow and go PMs. In and out, unless you try to sell something

  • @11dayzjourney
    @11dayzjourney 2 ปีที่แล้ว

    Why is there two contactors in this unit??

  • @engelperez4641
    @engelperez4641 3 ปีที่แล้ว

    Do all of these AC function the same way and have the same components if so it this stuff sounds really technical however I assume in time its repetitive.

    • @samiayyat4826
      @samiayyat4826  3 ปีที่แล้ว

      Thank you for the question. For the most part a Basic AC unit, split system or a package unit is usually operates in the same manner with same or similar components. Some manufactures may have some complex electronics, Variable speed drives or de humidification that may be a bit more advanced. Overall, you work on a few at the start of your career and they become easier. Attend seminars that manufactures have, this helps you in some ways understand and also gives you the opportunity to ask questions. My main type of work is supermarket refrigeration, i will be posting some vids soon.

  • @prithwishdey6708
    @prithwishdey6708 4 ปีที่แล้ว

    #sir please one video make on hvac compressor part winding cannection cannection.

  • @user-im8rm4wl4k
    @user-im8rm4wl4k 2 ปีที่แล้ว

    Do you always work in shirt?

  • @mohdvakeel7902
    @mohdvakeel7902 4 ปีที่แล้ว

    Nice

  • @mrgreen9086
    @mrgreen9086 4 ปีที่แล้ว

    I don't guage up on the unit unless my delta t seems off

    • @agx012
      @agx012 3 ปีที่แล้ว

      I always check pressures just because ive seen some units with a 20° differential between return and supply,,, but with a higher than normal head pressure and superheat, usually causing a higher amp draw as well,, caused by either a restriction in the metering device or in the filter drier.. either way its just good to always check

  • @tedallen9078
    @tedallen9078 4 ปีที่แล้ว

    amp draw taken from the blower motor is the proper method to determine belt tension. consult tech support for further information.

    • @Fryloc87HVAC
      @Fryloc87HVAC 4 ปีที่แล้ว

      belt tension tool is the proper way. amp draw will tell you a lot of other things though.

    • @tedallen9078
      @tedallen9078 4 ปีที่แล้ว

      @@Fryloc87HVAC belt tension tool will set the belt's deflection. amp draw will tell you the motor's performance at any given deflection. check with the manufacturer. don't take my word. the manufacturer will provide the required specifications.

    • @samiayyat4826
      @samiayyat4826  4 ปีที่แล้ว +1

      some motor you can't reach especially with the door off, safer not to put your hands where there are moving part regardless of what the manufacture says. they don't pay you for workman comp, some of the customers dictated where they want this done. Thanks for your input.

    • @petersplat6164
      @petersplat6164 3 ปีที่แล้ว

      If the amp draw is good, and the belt is flopping like a fish, what are you going to do, leave it? Don't be a hack. If the amp draw is good, you may improve it by adjusting the belt properly, and that would be a job well done.

    • @tedallen9078
      @tedallen9078 3 ปีที่แล้ว

      @@petersplat6164 the amp draw would never be ok with a flopping belt. amp draw and belt tension are one and the same. check the manufacturer's specification.

  • @dineshkumar-kl4hm
    @dineshkumar-kl4hm ปีที่แล้ว

    👍

  • @brennansulton340
    @brennansulton340 5 ปีที่แล้ว +2

    Fans moving to slow- bad capacitor. When you check anything on the unit the door must be on some what on for real readings lol 8/10 video thanks for sharing

    • @trials6502
      @trials6502 4 ปีที่แล้ว +1

      If the fan is moving too slow the motor itself could be failing as well. But we could ignore all that, the speed youre seeing isn't accurate due to frame rates. Can even hear how choppy it is in the audio.

  • @TheGuitaronfire76
    @TheGuitaronfire76 2 ปีที่แล้ว +1

    Whoever is filming needs to get really close to what your hands are doing. Sometimes someone is watching the video that doesn’t know anything about HVAC and wants to learn.

  • @DankTank374
    @DankTank374 3 ปีที่แล้ว

    Hey thankyou

  • @nobetter7747
    @nobetter7747 4 ปีที่แล้ว +1

    im thinking of going to school for hvac . done construction and at 29 im over it and want a career change. is it too late? is it worth it? difficult? opinions and such is more then welcome.

    • @nobetter7747
      @nobetter7747 3 ปีที่แล้ว +1

      @@JulianPardenilla i jumped the gun and decided to get my epa licenses took two tries but i got universal and enrolled in a hvac trade tech school program my city has. really want to apprentice

    • @nobetter7747
      @nobetter7747 3 ปีที่แล้ว

      @@JulianPardenilla how does the whole union thing work. never joined one out of stupidity on my part. i want to make as much as possible and get as far as a can because i have every intention to submerge my time and money on getting set up. im only getting older and my kids are too ya know how that goes

  • @Sandalphonn
    @Sandalphonn 3 ปีที่แล้ว +1

    holding a hose about 15 inches down is just showing off water pressure, we should all be so lucky

  • @tedallen9078
    @tedallen9078 4 ปีที่แล้ว

    proper tension of the belt is done by amp draw

    • @tedallen9078
      @tedallen9078 4 ปีที่แล้ว

      @k bone amp draw take a few seconds

  • @jeremyvega9749
    @jeremyvega9749 4 ปีที่แล้ว +1

    Uh that garden hose is no match for that double coil

  • @noidy1381
    @noidy1381 3 ปีที่แล้ว +1

    I always make sure the system is working first before I start PM. You could be blamed that you unit was working fine until you touched it. 😂

    • @samiayyat4826
      @samiayyat4826  3 ปีที่แล้ว +3

      Most of the customers we serviced when i was at this company had energy management services. we often would contact that service to force all the units on so that we could check operation. Also, some EMS companies will allow you access via app on your phone so that you may cycle on and all stages of heating and cooling. In larger supermarket operation, you will have EMS units such as Danfoss, E2, Novar etc that your able to graph and read logs that give you alot of important information. Most PM's are set at a low cost to the customer or they are not charged. This allows the contractor to service a customer and produce found on work. Meaning, if you show up, run the unit and find the Condenser fan motor not running, you would quote it out. Every customer has different rules especially with large Box stores and large retail chains. I always recommend for everyone to understand your companies goals and processes. understand the customers contract so that you can play within their rules. be very descriptive with your information and detail your report with high accuracy. take tons of photos this way you can show your customers exactly what they need and build that trust with you and your work. best of luck hope you found this to be helpful.

  • @darrenbeavers8099
    @darrenbeavers8099 11 หลายเดือนก่อน

    You must of shut the main off if you were checking the top side of that disco. Lol

  • @gringoloco543
    @gringoloco543 9 หลายเดือนก่อน

    You SHOULD NOT hook up service gagues doing a PM.
    A clever technician can get all the information they need by reading temperatures.

  • @clevc112
    @clevc112 3 ปีที่แล้ว

    Discharge the capacitor before you touch its connections.

  • @Shane.vanilla
    @Shane.vanilla 5 ปีที่แล้ว +1

    Draining lines?

    • @knust5707
      @knust5707 4 ปีที่แล้ว

      I would have hit the drain regardless of pan condition.

  • @Unknown_user558
    @Unknown_user558 4 ปีที่แล้ว

    goat

  • @Blackera44Avidd
    @Blackera44Avidd 5 ปีที่แล้ว +2

    Any advice for someone thinking about enrolling in an Hvac course versus a plumbing course?

    • @HERO-RIC
      @HERO-RIC 5 ปีที่แล้ว +2

      I'm going to HVAC school this fall. I think it'll be worth it. you have to go all in bro if you're going to do it!!!

    • @kylehotchkiss1491
      @kylehotchkiss1491 5 ปีที่แล้ว +7

      im 35 with a nine year old, no job at the moment, already 23+ hrs into the 600 hr. course . will be done in 5 3/4 months. Just get it done. Sacrifice now to have a job paying 30+an hour later.

    • @kareemwalton1
      @kareemwalton1 5 ปีที่แล้ว +3

      Rick Rodriguez bro so am I. I’m 24. School starts next week aug 19th. I’m excited. I’m doin pm classes

    • @catrinacraft
      @catrinacraft 4 ปีที่แล้ว +1

      I would ask a plumber personally but it depends on what you want to tolerate as far as hours and outside weather. It's more than $30 an hour....

    • @Fryloc87HVAC
      @Fryloc87HVAC 4 ปีที่แล้ว

      plumbers have to deal with poopy water on the regular lol. keep that in mind. HVAC has been good to me so far (4 yrs)

  • @greatestever5775
    @greatestever5775 5 ปีที่แล้ว

    Is this in Rancho?

    • @michaelc5943
      @michaelc5943 4 ปีที่แล้ว

      Greatest Ever artic mechanical is based out of rancho Cucamonga ,Ca

  • @whyYoustalking
    @whyYoustalking 3 ปีที่แล้ว +1

    Is coil cleaning really involved in a P.M?

    • @johnstewart2767
      @johnstewart2767 2 ปีที่แล้ว

      Depends on the season. In the spring, for sure. In the winter, not as much.

    • @whyYoustalking
      @whyYoustalking 2 ปีที่แล้ว

      @@johnstewart2767 I've never once in my life done a coil cleaning when doing a PM 🤷🏼‍♂️. Here in New York City those are two different jobs.

  • @nathannutt1743
    @nathannutt1743 4 ปีที่แล้ว

    No super heat or sub cool .
    I personally like to see it .
    S-man 4 will help you out alot man .
    I have learned sometimes installers leave it on 240 when it's 208 I didn't notice it .

    • @samiayyat4826
      @samiayyat4826  4 ปีที่แล้ว

      Great points you make Nathan, unfortunately the average new tech struggles enough to understand super-heat or Sub-cooling or even read a PT chart. the S-man and other similar digital gauges are great to use, but when the simple things such as cleaning coil or identifying how to test a unit are missed by your average PM guy, The S-man may be a bit too much tool for him or her. As i get the opportunity to create more content, we will definitionally use more advanced tool on things like start up where they can be really useful.

    • @michaelc5943
      @michaelc5943 4 ปีที่แล้ว +1

      Why would u check Subcool or superheat on a Maintenance package unit call unless u suspect problems.

  • @xingadogx
    @xingadogx 3 ปีที่แล้ว

    Don’t forget LOTO.

  • @clevc112
    @clevc112 3 ปีที่แล้ว

    Forgot to lock it out.

  • @Ricky32908
    @Ricky32908 3 ปีที่แล้ว

    he didn’t check the subcooling???????? no superheat? bruh 💀

    • @samiayyat4826
      @samiayyat4826  3 ปีที่แล้ว

      You certainly can, having proper pressures and knowing your ambient you can do the math without having to check every single unit.

  • @edgarfernandez5460
    @edgarfernandez5460 5 ปีที่แล้ว +1

    Did he say Jamon Lemis. 😂😂😂

    • @samiayyat4826
      @samiayyat4826  4 ปีที่แล้ว

      His nickname is tasty lemons

  • @deavonsanchez3084
    @deavonsanchez3084 5 หลายเดือนก่อน

    New Foo unlocked. This foo comes with the clear shades for maximum saftey. He forgot his kneepads and elbow pads

  • @brettlafleur27
    @brettlafleur27 2 ปีที่แล้ว

    Turn it back on lol

  • @DankTank374
    @DankTank374 3 ปีที่แล้ว

    Can I subscribe lol

  • @Traci3815
    @Traci3815 4 ปีที่แล้ว +2

    I strongly recommend when replacing belt that you should loosen the motor first then install belt then tighten as needed. DON'T SNAP BELTS ON. Snapping a belt on can stretch belt and cause internal damage to the steel belting and shorten the life of the belt. The only time I don't do that is on critical running units where down time is critical.

    • @samiayyat4826
      @samiayyat4826  4 ปีที่แล้ว

      Thank you for your feedback, Time is of the e sense on a PM. It is definitely a point worth making but for the sake of time we did not cover this on this video. we will discuss this on larger units such as build ups on a three, four or five groove pulley with larger turbines such as forward curve blowers etc.

    • @jayr4980
      @jayr4980 4 ปีที่แล้ว +1

      Perhaps, but how much stretch & stress was inflicted on the drive belt by installing with that method? And by how much does it really shorten its life? There is no way a technician will have time to loosen every motor. These drive belts are manufactured to sustain such stress before fully failing

  • @vladimpaler2651
    @vladimpaler2651 3 ปีที่แล้ว

    Not as good as others. No detail information really visible.

  • @s550wulf9
    @s550wulf9 ปีที่แล้ว

    Video is informative but wrong off the bat. You DO NOT take pressures during a PM. One you can remove refrigerant from another system, and you aren’t vacuuming down you’re gauges every time to make sure no contamination. Thank god you’re not in the medical field. You check if the split is off. Rookie rookie rookie. Come on dude. You didn’t check the indoor blower bearings, you need to clear the drain every time and drop in you’re tablets. You add pan tabs to avoid build up. I can’t watch past 6:25 the hackery there. Please tell me you put the panels back on, NOPE damn dude