Aapke smjhane K trika bhut acha h Sir very thankful video aagye mere dost v daikhengye shaire kr diye h nc no contact kaise bnte h instrument level jaise K presser switch practically
Bhai pressure switch ke connection wo drawing se mil jayega and kam kaise karta hai wo same as other pressure switch karta hai woise hi hai woise me us pe bhi video banauga with practical application.
Sir oo jo 3 pressure switch he, usme 1 seal pressure and 2 back pressure keliye he. So plz mujhe yeh bolia ki 2 pressure switch hum back pressure keliye q use karte he.
Sab to likhna possible nahi hai pur seal pressure na aye to direct pipe laga ke check kar lena chahiye ke air pressure utne bar ka hai ya nahi agar hai to dome seal replace kare agar nahi hai to air ko maintain kare
Ap sayad back pressure ke bare me bat kar rahe hai or seal pressure and conveying pressure hota hai ap thoda details me bataye to me ap ki kuchh help kar saku.
Agar pressure switch kam nahi jarega tab ap ka system healthy nahi batayega kyo ki no nc signal nahi milega and sov nahi kam kiya to ap ka system like power cylinder operate nahi hoga so ap easily identify kar sakte hai
Primafaice issue that cylinder not operate but after electrical rectified it working normal so I want to know from mechanical point of view, because generally electrical blame to mechanical dept.that cylinder is faulty etc, seal pressure 3.8kg , dome and cylinder proper alignment
Hi sir Mera dome seal or dome dono fail huva tha mene new seal and dome install Kya fir bhi second day seal break ho gya to ape reason bata sakte he. Sytem dome seal pressure:-5.5 -6 kg/cm2 rahta he Minimize ke liye koy idea 💡 bata do
And one more question What is the difference between Instrument air and conveying air? (I mean that conveying ke liye instrument air ka use kyu ni karte hai?)
@@eidilipsahani6800 Sir 1-Seal pressure, back pressure,aur conveying pressure Kya hote 2- pressure switch se kiska kiska signal jaata hai PLC ko Aur PLC kisko kisko signal bhejti hai kis sequence me Plz ache se bataaye If it's possible then solve these problem through a video
1 seal pressure it is for sealing the dome valve 2 Back pressure it is created when conveying line is jammed 3 conveying pressure it is for conveying the ash from vessel to sylo 4 ash handling plant working process. .Seal pressure is healthy then it's timmer will continue and operate the dome after that conveying is done and if line is jammed than back pressure form. In which total 2 sov and 3 pressure switches are use. Which I already told in this video also in this also you will get which singnal comming from PLC and to PLC. If you not getting then free to ask
It's may be poor quality of dome seal you got or may be your seal pressure is not maintain or may be your seal pressure is lower then conveying pressure there is many reasons bro
Air pressure bhi ho sakta hai Dome ka bhi isse ho sakta hai Normal operations ke badh wo thick ho jata hai wo bhi ho sakta hai Ap ko pehle wo pata karna padega
@@sajedursojib453 then why are you asking for purpose I think you better know that is it's use for and if you are facing any issue then I will give you suggestion buddy so must be reffer manual for its purpose
Vessel pressure high hone ka reason ash conveying line chocking hota hai so need to flush your ash conveying line and make back pressure less then 0.5 bar
Mere yaha seperate PLC panel hai so i can't show you dcs connection but both are same there are IO and you have to select chanel and io in dcs also need to create logics in programing for ash handling system.
Sir can u tell me that why does we speak master vessel to master? I mean master vessel ko master hi kyo bolte hai, aisa konse components hote hai ya aisa konsa design hota hai uska? Please tell me in detail.
Aapke smjhane K trika bhut acha h Sir very thankful video aagye mere dost v daikhengye shaire kr diye h nc no contact kaise bnte h instrument level jaise K presser switch practically
Thankyou
Valuable work ...... impressive ❤️
Bhai aap ka video content mast hai...keep it up..aur v video banao.
Nice work and congratulations for the channel nice informative video about APH.....keep it up👍👍👍
Jabardast mere bhai.....thank u 🙏🙏🙏🙏🙏🙏.....brother master and slave and different selection of mode.....kaise karte usape bhi video banaoo please
Sure buddy give me some time I will definitely make some videos on it.
Sir 1hi video h aapka jo sbse best h aur v bnaye sir instrument realated I'd fd pa
Thanks bhai plant Me kam jayada hai projects chal rahe hai time milte aur upload karta hu.
Thanks sir for this information
pressure switch ke connection aur kaise kaam karta hai btaye pls
Bhai pressure switch ke connection wo drawing se mil jayega and kam kaise karta hai wo same as other pressure switch karta hai woise hi hai woise me us pe bhi video banauga with practical application.
Nice. Good job 👍
I think a good video for education purpose.👍
Thankyou bahu अच्छा वीडियो h siR
Thanks
good information sir
Ash handling system prr interview questions banao
No one can ask of it but if u want to prepare it's details like size and capacity which are mention in your manual
Very nice sir
Nice explanation.
Thankyou
Good keep it up👍
Valuable knowledge ❤️sir
Thanku
very nice keep continues 🙏
Thanks
Very informative sir.
Too too good.
What should minimum pressure of seal and conveying in ash handeling system.
Seal pressure 5.5 to 6.5 bar
Conveying pressure 4.5 to 5.5 bar
Or as per your Manual.
@@eidilipsahani6800 Thankyou sir.
I'm waiting your next video
Welcome
Good for knowledge
Please prepare vedios regarding supercritical boiler operations.
Regards,
I'm not getting you buddy??
Achha video hai air banao👍
Nice explanation
Thanks❤
Thank you so much
Nice sir...
Thank you sir ❤
Thanks 🙏
Thank you 💕😊💕
Thak you sir
ESP ke d pump related video bhi Bana ke upload kariye.
I will
Aph system me seal pressure gauge me so karne ke liye alag se sov lagane ki jarurat padati hai sir ji
Already diya rehta hai gauge which I already discussed in my this video at panel area kindly visit and check out one more time
Nice
Nice sir
Thanks
Thanks 🙏🙏🙏 bro
Welcome
Sir! We need more Videos....
Thanks for the comment champ but due to work load i am not able to make a videos right now.
What is the reason if command goes to third field switch valve during second field conveying time.
Must be check your plc or DCS connection and logics for this kind of issues
Mster slave p video bnao sr🙏🙏
Jarur banauga
Nice video
Ser dom seal bar bar kat jata hai to kya karen
Cause kya hai wo pehle find out karo apka problems solve ho jayega
Sir Ji aap jo equipment lage hai use or details me video banaiye and uski jarurat kyo hai ye bataiye
Seal foult problem occurred frequently in my system pls suggest for 500mw unit
If you are provide some details like seal pressure set, dome is ok or it's created some edge?
Sir oo jo 3 pressure switch he, usme 1 seal pressure and 2 back pressure keliye he. So plz mujhe yeh bolia ki 2 pressure switch hum back pressure keliye q use karte he.
Kabhi kabhi system ko ye bhi pata hona chahiye ke conveying air pressure healthy hai ke nahi to uske liye ek aur pressure switch hai
Line change kaise karte h, aur image ke sath allpart ka name bataye
Plc ar dcs ka es system ka video bhi banaye
Kya hai ap ka question thoda detail me bataiye.
Sir ash handling system me air pressure ki puri cycle bataye ki air kaha se kaha jati he
Aur panel me seal pressure nahi aata to kya kar na he
Sab to likhna possible nahi hai pur seal pressure na aye to direct pipe laga ke check kar lena chahiye ke air pressure utne bar ka hai ya nahi agar hai to dome seal replace kare agar nahi hai to air ko maintain kare
Vessel pressure bhi hota h ? Iske baare m btayiye
Ap sayad back pressure ke bare me bat kar rahe hai or seal pressure and conveying pressure hota hai ap thoda details me bataye to me ap ki kuchh help kar saku.
Plc me sys chal raha hai but field nahi chal raha problem solve please ji
Sir please master or slave ke bare me bhi ak video bna dijaye
Already banaya hua hai ap dekh sakte hai
Sir isme kabhi pressure switch or sov kam nhi kr rhi he to kase check kare please reply me sir
Agar pressure switch kam nahi jarega tab ap ka system healthy nahi batayega kyo ki no nc signal nahi milega and sov nahi kam kiya to ap ka system like power cylinder operate nahi hoga so ap easily identify kar sakte hai
👌
Thanks
some times cylinder not operate properly( if it slightly t up manually then it open or close)
What would reason?
Check cylinder alignment
Same wording used by ele.dept.but I thought there pressure issue(not proper pressure to cylinder )
Pls explain all the issues if any parameters are abnormal etc so i can explain you mr dixit
Primafaice issue that cylinder not operate but after electrical rectified it working normal so I want to know from mechanical point of view, because generally electrical blame to mechanical dept.that cylinder is faulty etc, seal pressure 3.8kg , dome and cylinder proper alignment
There is no mechanical things i think im also from electrical instrumentation i can do all the things no need of mechanical in pneumatic systems
Hi sir
Mera dome seal or dome dono fail huva tha mene new seal and dome install Kya fir bhi second day seal break ho gya to ape reason bata sakte he.
Sytem dome seal pressure:-5.5 -6 kg/cm2 rahta he
Minimize ke liye koy idea 💡 bata do
Use heavy duty dome seal i think your problems will solve
Control valve and mov ka vedio banaye sir please
Liw k bare me v bataiye
2 we on of valve se pressure drope ho rha hai kya kre sir plz
Clear nahi ho raha hai ap kya kehna chahte ho achhe se batao??
Ok sir
Sir mai aap ko video bhej skta hu kis par bheju
7020173388 call me
Agar lagane ki jarurat ho to kaise laga sakte hai
Sir meko ye achhe se janna hai I'm a instrument technician jayaswal Neco
Padhai karo jan jaoge bhai
Sir c&i ka kya kam hai ash handling me kripya kar ke mujhe bataiye
Sab apna hi kam hai bhai jo video me dikh raha hai
Sir ji namaskr.. Ash handing start karte h to pahle preser kaun sa kholenge 1inch wala ya 1.5 inch presser plz clear me.. Ok
Dono
Sir our basic knowledge
I am not getting you can please explain
And one more question
What is the difference between Instrument air and conveying air?
(I mean that conveying ke liye instrument air ka use kyu ni karte hai?)
Instrument air ka cost badh jata hai because of dryer n all so we can't use in company our first priority to minimize the cost.
Sir 5/2 sov to double acting valve ke liye hai na fir aapne q single acting bola
Sorry for late reply its for double acting
sil pressure nahi aa raha hai sir... sab chek kar liya n sab sahi hai
System ka pic dikhao apne
Sir limit switch kis company ka hai or wo only air se kaam kr raha hai kya
Bhai limit switch Duncan make hai and ha wo sirf air se kam kare wohi application ke liye hai yaha par.
Bhai isko ek ek cheej ko aur jyada elaborate karke batiye....aur Kya Kya problem aati hai aur u he rectify kaise karte hai plz
Ap ko jo bhi problem ati ho ap muje batao i will definitely try to solve your problems
@@eidilipsahani6800
Sir
1-Seal pressure, back pressure,aur conveying pressure Kya hote
2- pressure switch se kiska kiska signal jaata hai PLC ko
Aur PLC kisko kisko signal bhejti hai kis sequence me
Plz ache se bataaye
If it's possible then solve these problem through a video
1 seal pressure it is for sealing the dome valve
2 Back pressure it is created when conveying line is jammed
3 conveying pressure it is for conveying the ash from vessel to sylo
4 ash handling plant working process.
.Seal pressure is healthy then it's timmer will continue and operate the dome after that conveying is done and if line is jammed than back pressure form. In which total 2 sov and 3 pressure switches are use. Which I already told in this video also in this also you will get which singnal comming from PLC and to PLC.
If you not getting then free to ask
Silo plant ki A to Z jankari bta do sar ji
Like what you want from silo?
Seal pressure.
Healthy nhi hoga to kya nuksan hoga
Dome and it's spigot may damage if it is not healthy
Vedio ka link hoga aapke kya
Konsa video??
Esp details..ka vedio
BAHUT ASSA VI
MASTER SLAV KE BADI ME
Jarur try karunga us pe bhi ek video banau
more information about ash handling ..
Like what?
Coil ka cnecosion rile me kyse krte hai
Thoda details me batao kya janna hap ap ko
Ash handling & Esp ka detail..chahiyen with pratical sir....plz
Ash handling given by om engineering and esp by thermax
Kese seal pressure check karte hain practicali bataie
Ap gauge me dekhiye show karega seal pressure pls check in my video 😊
Dense Phase & Line Phase please explanation .
Dome value not convingline solution?
Kindly elaborate your issue so i can understand and give the solution pls
Sir dome seal kaise change karte hai
Next time jab seal change hoga i will make practical video on it for you buddy
Stacker recklmer ke baare mein batayen
"Stacker reclaimer " I'm not working on it
What are the reason for continuosly dome valve seal and o ring damage
It's may be poor quality of dome seal you got or may be your seal pressure is not maintain or may be your seal pressure is lower then conveying pressure there is many reasons bro
How to find it seal got damaged
Compare with input air pressure and seal pressure if it is below then you can get it it's seal are damaged simple
Dom sill katne ka karan kya hai
Air pressure bhi ho sakta hai
Dome ka bhi isse ho sakta hai
Normal operations ke badh wo thick ho jata hai wo bhi ho sakta hai
Ap ko pehle wo pata karna padega
What is the purpose of this seal air? Why we have to maintain this pressure pls clarify?
Buddy I think you are need to study about this and if after that you have any Doubts you must be ask me.
@@eidilipsahani6800 ok. What is the purpose of ash vessel booster assembly pls clarify?
Are you working on it???
@@eidilipsahani6800 yes.
@@sajedursojib453 then why are you asking for purpose I think you better know that is it's use for and if you are facing any issue then I will give you suggestion buddy so must be reffer manual for its purpose
Full video banaiye na one by one
Vessel pressure high h to kya matlb
Vessel pressure high hone ka reason ash conveying line chocking hota hai so need to flush your ash conveying line and make back pressure less then 0.5 bar
Kis material ka hai plz name bhi btaiye
Kindly explain what are you talking about ?
Sir mujhe pressure switch ke bare me janna hai
Bhai usme me kya help kar sakta hu ap puchho
Mastr dom ketne prkar ke fart rhte hi
Means???
Iska connection jo dcs aaya h o btaye
Mere yaha seperate PLC panel hai so i can't show you dcs connection but both are same there are IO and you have to select chanel and io in dcs also need to create logics in programing for ash handling system.
Pressure switch ka kam kiya hai
Sir can u tell me that why does we speak master vessel to master? I mean master vessel ko master hi kyo bolte hai, aisa konse components hote hai ya aisa konsa design hota hai uska? Please tell me in detail.
Time milte hi master and slave pe video banauga bhai
seal pre.is not showing healthy then which types of prb.are created ..nd that time hows chek seal pre.
Already told in comment if it is not healthy then too system are running then its dome n its assembly may get damage and you can Easley check ok gauge
Sir mere ko pura tubing bataye ki kaise kare
Tubes ke bare me janna hai to ap ko uski manual padhni chahiye fir bhi na samjhe to ap mujse puchho me ap ko bataunga
ऐश हांडलींग के कितने प्रकार होते है
You must read on google
Sir plc control system samjaeye
Jarur ek video banata hu plc pe bhi bahot jaldi
Ballo Ka Kam Kaya Ha
Due to temperature line get expand so it will help and save the system
master and slave d pump ke bare share please
Sure give me some time buddy
Poppet vavle dismental Kar k Ripering and full name pepper vavle pats
I will try
Sir inst and service airline connection explain in esp line
For seal pressure used instrument air and for conveying we used service air
Sir
Ash handling yer Pressure kya hona
Tum ko kiska air pressure hona instrument air or conveying air pressure
2:55😢cylinder close hai aur aap usko open bol rahe ho ,3:00 mai open huwa hai toh aap close bata rahe ho
Watch it clearly buddy
Cylinder open hua means dome close hua and vice versa.
Hello Sir
Sir hamara system PE roj sil likes hojarahahe
Seal pressure and conveying pressure kitna hai and seal konsa use kar rahe ho?
SUV Mein oil a raha hai air filter se
Achhe se bataiye ho kya raha hai ?
Plz tell mi Master Slave operation
Ok
AAP ka awaz sahi Nehi hai
PS 1 PS2 PS3 ka matalab kya hai
It's pressure switch 1 2 3