Installing a back up sump jet

แชร์
ฝัง
  • เผยแพร่เมื่อ 6 ม.ค. 2025

ความคิดเห็น • 15

  • @MrSoulMonk
    @MrSoulMonk ปีที่แล้ว +1

    Just superb! What a pro!

  • @nealgiddings2496
    @nealgiddings2496 9 หลายเดือนก่อน

    1. You can connect them to the same discharge pipe? I always wondered why not but everyone says not to. Not sure why its a problem(non plumber here) as because the whole point is to just have a back up for the malfunctioning pump that's no longer working. 2. what are those metal rods that so nicely hole things in place specifically called so I can order thanks. Again non plumber and not a super handy guy but a home owner and having to learn this stuff...paying someone cost my first child now a days lol thanks.

  • @devavilluri
    @devavilluri ปีที่แล้ว

    Do we need to install the double check wall assembly you added for this sump jet to work?

    • @davejoseph5615
      @davejoseph5615 11 หลายเดือนก่อน

      The problem is that you are connecting your drinking water system up to a dirty old sump pump. You need to be very careful.

    • @Seashea
      @Seashea 7 หลายเดือนก่อน

      @@davejoseph5615what if you add a check valve on the 3/4 supply that feeds the back up pump

  • @salvenezia1817
    @salvenezia1817 9 หลายเดือนก่อน +1

    can you explain that regulator you install the purpose for that

    • @joshuarivera2422
      @joshuarivera2422 3 หลายเดือนก่อน

      Rpz valve, is a type of back flow preventer but that drips water when it malfunction, so it's way more expensive than a normal backflow preventer. The purpose is so that the contaminated water if the sump pump does not flow back into the house water line.

  • @davejoseph5615
    @davejoseph5615 11 หลายเดือนก่อน

    Yeah, I bought one of those Sump Jets and a Zurn 720A but I'm not confident enough to install it, so it is still sitting in the box.

  • @familydad3241
    @familydad3241 6 หลายเดือนก่อน

    What you charge for a job like this?

  • @fluffynutz730
    @fluffynutz730 ปีที่แล้ว +1

    Awesome Job ! Keep Posting :) What state are you licensed in ?

    • @plumbingsk8r
      @plumbingsk8r  ปีที่แล้ว

      New York

    • @johngraves8561
      @johngraves8561 8 หลายเดือนก่อน

      In Lewiston NY, you need 2 discharge lines per code.

    • @scow01
      @scow01 21 วันที่ผ่านมา

      ​@plumbingsk8r what part of ny? I have a sumpjet I'm going to install after my basement flooded when the main pumps switch got stuck. Trying to find out the code requirements for the DC backflow preventer. In albany ny. Cannot find the requirement of whether I need what you installed (007m3qt or other nys approved versions) or the significantly more expensive rpz versions.

    • @fluffynutz730
      @fluffynutz730 20 วันที่ผ่านมา +1

      ​@@scow01 Here in Illinois we have to install a Double Check valve with an atmospheric vent. 👍

  • @rustyme1122
    @rustyme1122 10 หลายเดือนก่อน

    A 90 deg vent elbow on the discharge pipe. Really?