Checking the Correctness of the Socket ANENG AC11 Tester

แชร์
ฝัง
  • เผยแพร่เมื่อ 6 พ.ย. 2024

ความคิดเห็น • 12

  • @ElectroCarpintero
    @ElectroCarpintero 8 หลายเดือนก่อน +2

    This equipment is very good and accurate for fast testing in home facilities.
    When it shows INCORRECT, you must turn the instrument. When it shows CORRECT, then you can make of RCD test.
    The RCD test did not work, because you were using the equipment with rechargeable batteries, which will operate at 1.2V, and this equipment works at 1.5V, with Alkaline batteries.
    Greetings

  • @okaro6595
    @okaro6595 ปีที่แล้ว

    The beeping is because it detects the voltage near the ground contact. This can save lives as you immediately hear if the ground contact is hot. This can be case on TN-C if someone has messed with the wiring.

  • @LeoGerritsen
    @LeoGerritsen ปีที่แล้ว +3

    this kind of socket does not have a prescribe method for the orientation of L and N, turn the tester
    180 degree and see what happens

    • @ricardoribeiro8037
      @ricardoribeiro8037 ปีที่แล้ว

      Rubbish, the tester is very accurate if any wires are wrong in the socket. I found a problem in one place with it as Line and Neutral were interchanged and the tester showed it.

    • @okaro6595
      @okaro6595 ปีที่แล้ว +2

      ​@@ricardoribeiro8037If you rotate the tester then it shows a different result. Different countries have different standards where the phase and the neutral are connected. In Finland the phase iso the right. Germans seem to prefer to put it on the left. It really does not matter as you can plug the plug either way.
      Note same applies to Aldo the French plugs that cannot be reversed. French put the phase on the right whike Czech put it on the left.

  • @williamnot8934
    @williamnot8934 ปีที่แล้ว +2

    Clean that tiled wall please.

  • @deepblueskyshine
    @deepblueskyshine 8 หลายเดือนก่อน

    Предраг, дали фазата се е паднала отляво или отдясно се разбира и с фазомер за 50 цента (за Шуко няма норма от коя страна да е), а като погледнеш таблото с предпазителите и видиш такива с двойна ширина и малко бутонче, значи инсталацията има диференциална защита и работата и се проверява с натискане на бутончето, а ако няма ... такъв е живота ;)

  • @WALLACE7084
    @WALLACE7084 ปีที่แล้ว

    It obviously won't do a RCD test because it's detected that it's wired wrong and could possibly cause a bigger problem by trying to trip the RCD.

    • @VeslinovPredragandroid
      @VeslinovPredragandroid  ปีที่แล้ว

      Could there be any problems?

    • @ricardoribeiro8037
      @ricardoribeiro8037 ปีที่แล้ว

      The Instructions weren't followed correctly if i'm not mistaken

    • @okaro6595
      @okaro6595 ปีที่แล้ว

      It likely tried but it does not trip of the neutral is where it expects the phase. The sockets necessarily were not wired incorrectly, just differently from what the tester expected. Schuko is used in dozens of countries each with different codes, standards and practices.

  • @malikproductions6661
    @malikproductions6661 ปีที่แล้ว +1

    I'm watching from jammu and kashmir india