Swagelok® Back Pressure Regulators Made Simple

แชร์
ฝัง
  • เผยแพร่เมื่อ 4 ก.พ. 2025

ความคิดเห็น • 8

  • @yuoyio1987
    @yuoyio1987 3 ปีที่แล้ว

    We have two! this is an amazing fix!

  • @prashantpopalghat7194
    @prashantpopalghat7194 4 ปีที่แล้ว

    Hello Team,
    For back pressure regulator, is there any impact on valve operation if downstream back pressure is higher that 80%

  • @prashantmutyala8222
    @prashantmutyala8222 8 ปีที่แล้ว +3

    A question on back pressure regulator. If I have a gas source at 800 PSI and I wanted to let it into a machine at say 3000 PSI, I will use a back pressure regulator. THE BPR will open when the back pressure is above 3000 PSI but what decides the amount of flow through the valve? Can I control the flowrate as well using a BPR? Would using a BPR lead to intermittent flow?

  • @prashantpopalghat7194
    @prashantpopalghat7194 4 ปีที่แล้ว

    what is locking zone in self regulating valve?

  • @Fatboy53
    @Fatboy53 5 ปีที่แล้ว +1

    At 1:45 the pressure reducing sense line is backwards. Other than that, great video

    • @christopherwiggins7417
      @christopherwiggins7417 5 ปีที่แล้ว +1

      For pressure reducers, the sensing line is downstream of the valve. The sensing line is shown correctly

  • @tibodeclercq2131
    @tibodeclercq2131 ปีที่แล้ว

    "Made simple"
    Makes a 25 min video ....