An easier solution would be to plumb the exhaust from the heater directly into the cast iron radiator and use the heater output to blow across the radiator to circulate the heated air from both the heater exchanger and from the reclaimed heat from the exhaust through the radiator. Great video. Loved the clip of the firing view from the burner!
I thought that too but I think once the exhaust goes through the exchanger it would lose a lot of it's heat and might not be very effective in the large radiator
@@stefanospsikarakis8536 Hi, Kyle. How long is your baseboard and where did you buy it? Or was it used? That sounds like a great idea that I would like to try.
I give you an A for effort and hope you have a good carbon monoxide detector. The bubbles are created by the pump pulsing and if you don't want the error code 8 you have to mount the pump as vertical as you can with the outlet at the top and after that the fuel line must go up to the burner and not down. That way the fuel is always rising and with it the bubbles so they can't build up and cause a error code 8 which means lack of fuel.
! Thank you! The design of the vevor heater has the pump above the burner, and it is perpetually pushing a bubble, but it also does seem to work? But I think this makes sense, so for permanent install I will be sure to keep that in mind.
You don’t need to have it vertical . Needs to be at a 20 degree angle at least and every heater pump I’ve had always has a small bubble in it . Mount pump level or above tank. So you don’t flood the chamber once pump has some time on it
Fast det handlar inte om det...det handlar väl om att visa upp lite innovativa saker för hemmapulare. Denna video var ungefär som att någon uppfann trähjul till cyklar
Very creative and in my opinion , Well done ! It will need a drain for the condensation and have the unit tilt slightly to the other end to collect that moisture .
Very cool project. I'm guessing you're probably getting about the most energy you can get from a quart of diesel fuel. I would ditch the carbon filter and just run the exhaust outside somewhere. I'm impressed it got hot enough to run all 3 of those fans.😉👍👍👍
Kul att du fått upp visnings antalet på dina videos igen borde ha fler visningar på alla dina videos, så sjukt grymma videos glädjer mig alltid när din kanal går bra ha en fin dag 😊
I have done a setup that extracts the most out of a diesel heater with the exhaust using two exhaust gas recirculating units from vw Audi engines. And circulating water through them and off into a central heating radiator. Lots of extra heat and you get the same hot air from the heater as you would normally. I posted this on TH-cam about 12 months ago
Riktigt kul bygge, haft funderingar på ungefär samma... Men om man använder elementet med vatten glykol blandning, o istället för där du satte brännaren, sätter en vattenpump... O med avgaserna värmer upp elementet samt kunna använda värme utblåset som det är tänkt.... Bara en idé som farit runt i mitt huvud.... Bra jobbat!
Varför krångla till det? Ta avgasröret från värmaren och kör in i elementet så återvinner du värmen i avgaserna och får bättre verkningsgrad. Mycket enklare
Den här varianten av video är det sämsta jag sett. Jag tittade till slutet för jag trodde det skulle komma en förklaring .......men nej! Gör om och gör rätt, tycker enbart att det blev löjligt. Ingen tumme upp från mig!
@@RickardsGarageProbably worth welding a threaded insert at the slowest point of the radiator along with a bolt you can remove every now and then to get the water out.
Idén är ganska bra men inte om man inte leder ut avgaserna så ha allt inomhus nej det blir inte hälsosamt det finns folk som kör sån där diesel kanon inomhus och mår inte bra principen blir den samma
Fuel pump needs to be at least 45 degrees tilt. This prevents the bubbles. Look at how it’s mounted in the actual heater frame that it was originally in.
Tror Rickard vill få tittare utanför Sverige också vilket han förtjänar. Svårt att få mer än några hundralappar i månaden med enbart svenska tittare tyvärr. Han måste ju leva också.
@@LpG88exakt och det gynnar oss alla i längden. För det innebär att han har råd att köpa nya verktyg och maskiner att recensera och reservdelar till projekten och ibland nya projekt. Några såna här videos i halvåret kommer ingen dö av. Men det skulle lyfta hans kanal rejält. Man behöver ju inte ens titta på dem, om man tycker det är så extremt jobbigt som vissa verkar tycka.
Have you done anything with the air intake line on bottom or the other exhaust outlet on bottom of the machine I seen in this video look like nothing was connected to either
Put the heater at the top and exhaust at the bottom..this will prevent moisture collection at the bottom as all water vapour will be exhausted put...but if the exhaust is at the top there is a likelyhood of a water trap..
Jag har faktiskt en plan på att göra en liknande video. Effekten blir troligen bättre om det varma kommer in uppe och avgaserna ut nere men ett kul projekt! Det blir nog mycket kondensvatten i botten efter ett tag.
Your exhaust should be evacuated downstream to avoid condensation buildup in your exhaust pipes/ radiator. Condensation will not only accelerate oxidation of steel but it may accumulate and reduce the efficiency of the combustion...
fuel pump is supposed to be mounted at approx 45degre angle to expel the trapped air the bubble issue you have is caused by the green fuel line being a loose fit on the metal pipe
Tror Rickard vill få tittare utanför Sverige också vilket han förtjänar. Svårt att få mer än några hundralappar i månaden med enbart svenska tittare tyvärr. Han måste ju kunna leva också.
Kass var väl att ta i. Föredrar helt klart videor där han pratar och förklarar men detta var väl ingen raketforskning direkt. Hade du svårt att hänga med? Kör hårt Rickard! 👌👊
Detta är en klassisk click-bait video. Något alla youtubers måste göra då och då för att få fler tittare och interaktion med videon precis som du gjorde nu. Så även om du inte gillar det så hjälpte du honom nu med din kommentar. Så om du verkligen vill visa ditt missnöje så ska du inte klicka på ogilla eller gilla och du ska inte kommentera. Då får videon ingen reach. Vi fattar alla (inte du uppenbarligen) att detta är ett projekt som är bättre i tanken än i verkligheten. Ändå tar sig Rickard tiden att göra det. Ja avgasröret ska vara ut genom väggen istället! Alla fattar det. För att sammanfatta. Om du inte gillar en video, håll käften. Det gynnar dina och (som en bonus) våra intressen.
Bel progetto ⚡ *Ragnar!* ⚡ Ma soffocare così in verticale Non ti ha sporcato precocemente il bruciatore ? Rimane comunque un bel progetto Peccato che Per riscaldare casa Così il bruciatore non sia il massimo Troppi fili è bruciatore troppo esposto Io ho risolto da 4anni isolandolo all'esterno Prelevando aria dall'interno entra nel cinebasto È col tubo da 8 sparo dentro casa Sempre acceso da novembre a marzo al minimo È ci riscaldo 85mq ventilando tra ambienti forato da ø15 i muri è messi dei volgari ventilatorini USB da 5w pagati niente è super silenziosi Altro che canalizzare !🌹 *La pompetta ti si inchioda perché va tenuta appesa è inclinata di 35°* PS: comunque non sei riuscito a silenziare la pompa malefica 😂
”Tappat tråden?” Han är smartare än dig iaf, för du vet uppenbarligen inte vad som gynnar dig. Han gjorde en liknande video för bredare publik för ca ett år sedan. Den har han nästan en miljon visningar på(till skillnad emot vanliga snittet på ca 40-45k) = fler tittare = mer pengar = mer inköp av verktyg och maskiner som han kan testa, mer reservdelar, mer inköp av projekt = fler recensioner av verktyg och maskiner och fler ”vanliga” videos för dig att titta på och lära dig av. Det är ingen som dör av några såna här videos om året, det snarare gynnar alla som tittar på hans kanal.
As another subscriber said (A) for effort, but it seems to me that you’ve wasted your time by doing this. The original heater probably put out more heat and was safer by the exhaust being exhausted to the outside of the Building. it would be better to leave the heater, blowing the hot air into the building and the exhaust running through the radiator and being exhausted outside that may increase the heat value and certainly won’t kill you of carbon monoxide poisoning
Bonjour, Super invention ! Quand j'ai vu la découpe du bloc aluminium j'ai eu peur 😊 Quel est le poste à souder que vous utilisez svp ? Merci pour le partage de cette invention. Bien à vous
detta klipp påminner om jetmotorn som Colin Furze byggde för längesedan av en toaborstshållare och en gammal turbo. något du hade kunnat göra kanske. hade varit sjukt fett! B)
Är det här ett försök till att nå ut till dina tittare internationellt? Saknar ditt snack om vad som är på gång eller vad som är planerat. Tyvärr lite som att se Pakistanska gatuverkstäder som renoverar eller tillverkar otroliga saker. Kul och se, men saknar "Hej och välkommen till mitt garage"😁
Greetings from Finland. My second language is Sweden and still in most cases I miss the point of what he is doing in his normal videos. This is way better in my book.
You do realize that you are just absorbing the heat already being put out by the heater right ?? If you want to capture wasted heat run the exhaust of the heater through the radiator and then outside. You will then have the heat recovered from the exhaust and the heat blowing in the room from the heater.
Great idea, but this is very dangerous. If someone recreates this, they could die from all the carbon monoxide. This is not a joke, and this video should include a warning about it or be taken down. I respect that you want easy views and money, but giving people carbon monoxide poisoning isn’t the way.
If some do not see the danger of burning something inside your house or garage without proper ventilation or filtering, I call it nature's choice if something goes wrong. These are not for education.
@@Teknopottu exactly it common sense that he is using the excess exhaust heat and the exhaust should be vented properly from someone that is knowledgeable enough to take on this project.
I dont understand why people put videos on here and dont know the BASIC set up of these heaters.... ie full pump angle, exhaust angle and condense draining.
Error Code 8 Turn Fuel Pump on ANGLE 30-40 degrees eliminates Air Bubbles Silly Build Project 😂 No need to Butcher the Heater to achieve same result. Use old Tractor Radiator Use Flexible Aluminum or Steel Output Air Pipe into Tractor Radiator. Use 12v Electric Radiator Fan to Blow Air thru much smaller fins creating more BTU and better regulated heat. Project creates much better warm air flow 1/4 the effort 3/4 better results. Engineering Guru.
E sufficiente fare attraversare il tubo di scarico fumi, all'interno della parte bassa del termosifone. L'acqua all'interno del termosifone si riscaldera, sfruttando l'alta temperatura del tubo di scarico. mentre l'aria del cinebasto riscaldera un altro ambiente
An easier solution would be to plumb the exhaust from the heater directly into the cast iron radiator and use the heater output to blow across the radiator to circulate the heated air from both the heater exchanger and from the reclaimed heat from the exhaust through the radiator. Great video. Loved the clip of the firing view from the burner!
That is brilliant my friend 👏🏽👏🏽👏🏽 I love being able to read smart ideas in the comments.
What’s HUD spelled backwards? This was my first thought.
I thought that too but I think once the exhaust goes through the exchanger it would lose a lot of it's heat and might not be very effective in the large radiator
@kylersims6016 I used a forced hot water baseboard on mine and it works great!
@@stefanospsikarakis8536 Hi, Kyle. How long is your baseboard and where did you buy it? Or was it used? That sounds like a great idea that I would like to try.
denna är helt klart den bästa modden på kina brännare jag sett, respekt Rickard, men ut med avgaserna
Excellent workmanship and engineering! Increased efficiency. Well shown and good ideas.
Thanks 🤝😀
Absolutely wonderful! Thank you for showing us the process and its performance!!
I believe the fuel pump is to be mounted at a 45 degree angle to prevent air bubbles
Yes
I give you an A for effort and hope you have a good carbon monoxide detector. The bubbles are created by the pump pulsing and if you don't want the error code 8 you have to mount the pump as vertical as you can with the outlet at the top and after that the fuel line must go up to the burner and not down. That way the fuel is always rising and with it the bubbles so they can't build up and cause a error code 8 which means lack of fuel.
I didn't know about the pump so thanks!
! Thank you!
The design of the vevor heater has the pump above the burner, and it is perpetually pushing a bubble, but it also does seem to work?
But I think this makes sense, so for permanent install I will be sure to keep that in mind.
Good digamous
You don’t need to have it vertical . Needs to be at a 20 degree angle at least and every heater pump I’ve had always has a small bubble in it . Mount pump level or above tank. So you don’t flood the chamber once pump has some time on it
Pumpen skall monteras i ca 45 graders lutning. Ej liggandes horisontellt. Kolven i pumpen täcks inte av diesel annars.
Rett det. Luftbublar muste gå igjennom
Det lite roliga är att i videon han kopierar säger han exakt just det...
Min pump hänger i gummiband, som jag måste byta ut då och då. Ibland sitter den ”rätt”, ibland ”helt fel”. Fyra år senare fungerar den i alla fall.
Japp, påverkar ju även smörjningen negativt om den pumpar horisontellt läge.
@@celuldor hvilken video er det han kopierer? hadde vært gøy å se den og :)
Hello from France, superb vintage equipment, it never breaks down
Hello France! That is absolutely right!
Som andra redan nämnt, ta risken för kolmonoxid på allvar.
I övrigt ett inspirerande bygge. Tack!
Gnäll gnäll gnäll, tycker Rickard ska va stolt över sina framgångar. Kör hårt Rickard o skit i lipsillarna.💪
Fast det handlar inte om det...det handlar väl om att visa upp lite innovativa saker för hemmapulare.
Denna video var ungefär som att någon uppfann trähjul till cyklar
Very creative and in my opinion , Well done ! It will need a drain for the condensation and have the unit tilt slightly to the other end to collect that moisture .
Very cool project. I'm guessing you're probably getting about the most energy you can get from a quart of diesel fuel. I would ditch the carbon filter and just run the exhaust outside somewhere. I'm impressed it got hot enough to run all 3 of those fans.😉👍👍👍
Hjärnan full med idéer jag aldrig ens kommit i närheten av att komma på! Bra där Rickard! 👑
Dock helt fel ideer
Kul att du fått upp visnings antalet på dina videos igen borde ha fler visningar på alla dina videos, så sjukt grymma videos glädjer mig alltid när din kanal går bra ha en fin dag 😊
Outstanding. Top marks for ingenuity..
Glad you liked it! Thanks
That's pretty cool. Just wondering how do you discharge the condensate that builds up inside the radiator?
Haven't gone that far yet. Thanks !
I have done a setup that extracts the most out of a diesel heater with the exhaust using two exhaust gas recirculating units from vw Audi engines. And circulating water through them and off into a central heating radiator. Lots of extra heat and you get the same hot air from the heater as you would normally. I posted this on TH-cam about 12 months ago
Kul experiment 👍
Riktigt kul bygge, haft funderingar på ungefär samma...
Men om man använder elementet med vatten glykol blandning, o istället för där du satte brännaren, sätter en vattenpump... O med avgaserna värmer upp elementet samt kunna använda värme utblåset som det är tänkt....
Bara en idé som farit runt i mitt huvud....
Bra jobbat!
Varför krångla till det? Ta avgasröret från värmaren och kör in i elementet så återvinner du värmen i avgaserna och får bättre verkningsgrad. Mycket enklare
🤦♀️🤦
Avgasernas koloxid släcker ju lågan !
@ossanyberg EXAKT
@@andersolsson1198 nää
Många har testat det redan och det visade sig att man inte tjänade så mycket på det tyvärr
This guy makes some cool stuff.
Den här varianten av video är det sämsta jag sett. Jag tittade till slutet för jag trodde det skulle komma en förklaring .......men nej! Gör om och gör rätt, tycker enbart att det blev löjligt.
Ingen tumme upp från mig!
@@christerbrannebo8678 Jag tror Rikard försöker sig på en internationell karriär
Förklaring ? Du ser väl vad han gör.
@@andersolsson1198, men inte VARFÖR... 🙂
😂🤦♂️
@@christianjansson6806 Man behöver inte veta varför. (kanske för skojs skull)
Riktigt kul video Rickard, tummen upp. Hälsningar från Billinge
Glömde fråga, med tanke på hur mycket kolväten som förbränns rätt in i radiatorn....hur ser det ut med kondensansamlingen?
Tack! Har ingen aning ännu, den är i stort sett precis invigd.
Kul projekt, men tror ändå att den hade fungerat bättre hel och inte isär plockad :)
Nice build, inlopp och utlopp i elementet behöver dock byta plats för ökad effektivitet samt att ev kondens då också kan rinna ut. 👍
How do you solve the condensate problem?
Haven't gone that far yet
@@RickardsGarageProbably worth welding a threaded insert at the slowest point of the radiator along with a bolt you can remove every now and then to get the water out.
Stort tack! Intressant!
Uppfinnar jocke har fixat det igen..bra jobbat
L fan bracket mounted half way down causes fans to blow through radiator instead at the top, nice job chap!
your parents must be really proud of you
Trevlig video,i dag kom alla varor ,bra produkter,mycket bra packat, varför är du tyst,alltid trevligt att höra dig 😃👍
3-språkig video. Vår tusenkonstnär Rickard fixar det men blir nog jävligt struligt att lyssna på. 😂
Jag bytte till en silicon slang med mindre inner dia, då funkar det bättre
What about condensate? The rad needs to drain.
Haven't come that far yet but maybe
Bra denna video kommer få många visningar!
Intéressant: une idée , mettre une cale sous les pieds opposés à l'entrée d'air chaud, pour mieux répartir la chaleur émise .
härlig utmaning för dom konservativa med stumfilm =))
Underbar video igen, fiffigt helt klart
Idén är ganska bra men inte om man inte leder ut avgaserna så ha allt inomhus nej det blir inte hälsosamt det finns folk som kör sån där diesel kanon inomhus och mår inte bra principen blir den samma
Tips on locating old used steam radiators like the one used in this video?
Fuel pump needs to be at least 45 degrees tilt. This prevents the bubbles. Look at how it’s mounted in the actual heater frame that it was originally in.
Det är synd att du inte snackar i videon. Hur gick det med kolet, tog det bort avgaserna eller lukten?
Tror Rickard vill få tittare utanför Sverige också vilket han förtjänar. Svårt att få mer än några hundralappar i månaden med enbart svenska tittare tyvärr. Han måste ju leva också.
@@LpG88exakt och det gynnar oss alla i längden. För det innebär att han har råd att köpa nya verktyg och maskiner att recensera och reservdelar till projekten och ibland nya projekt. Några såna här videos i halvåret kommer ingen dö av. Men det skulle lyfta hans kanal rejält. Man behöver ju inte ens titta på dem, om man tycker det är så extremt jobbigt som vissa verkar tycka.
Han skulle kunna prata svenska och lägga till engelsk subtitle istället för att vara tyst 😢
Jag tror att avgaserna gjorde att talet försvann..
Tycker sällan dessa "none speaking videos" är särskilt bra. Känns bara mindre seriösa, lite öststats- känsla faktiskt!
Pumpen funker best vis den står i 30 grader vinkel. Å dem myke slangen der er ikke bra. Bedre med hvit litt hard slange. Ellers genialt😊
Have you done anything with the air intake line on bottom or the other exhaust outlet on bottom of the machine I seen in this video look like nothing was connected to either
I haven't done anything to the inlet, it uses tha air from the room at the moment
Put the heater at the top and exhaust at the bottom..this will prevent moisture collection at the bottom as all water vapour will be exhausted put...but if the exhaust is at the top there is a likelyhood of a water trap..
Why did you de-badge your Ryobi stuff?
Jag har faktiskt en plan på att göra en liknande video. Effekten blir troligen bättre om det varma kommer in uppe och avgaserna ut nere men ett kul projekt!
Det blir nog mycket kondensvatten i botten efter ett tag.
Det är fullt möjligt men dock så går ju ärmen upp. Lycka till 😀
@RickardsGarage Snyggt med kamin fläktarna😁 5 poäng!
Akta så att du inte blir förgiftad av avgaserna bara kolmonoxid är inget att leka med
Your exhaust should be evacuated downstream to avoid condensation buildup in your exhaust pipes/ radiator. Condensation will not only accelerate oxidation of steel but it may accumulate and reduce the efficiency of the combustion...
The creation of the oil fire furnace
Max length of exhaust tubing is 3 feet. Anything longer will cause problems.
fuel pump is supposed to be mounted at approx 45degre angle to expel the trapped air the bubble issue you have is caused by the green fuel line being a loose fit on the metal pipe
Skulle inte pumpen sitta vinklad har för mig att din danske vän höll på med de där
Jag skulle också skriva om det. att dom skulle sitta lutande.
Du vet när man ska kopiera någon annan måste man ju försöka vara lite originell :D
Inget prat, Inget berättande och inga förklaringar,.videon blir riktigt kass utan det! Snälla Rickard låt detta bli första och sista gången!
Det är inte första gången heller. Men Rickard får göra som han vill
Livet måste vara jobbigt för dig.
Tror Rickard vill få tittare utanför Sverige också vilket han förtjänar. Svårt att få mer än några hundralappar i månaden med enbart svenska tittare tyvärr. Han måste ju kunna leva också.
Kass var väl att ta i. Föredrar helt klart videor där han pratar och förklarar men detta var väl ingen raketforskning direkt. Hade du svårt att hänga med?
Kör hårt Rickard! 👌👊
Detta är en klassisk click-bait video. Något alla youtubers måste göra då och då för att få fler tittare och interaktion med videon precis som du gjorde nu. Så även om du inte gillar det så hjälpte du honom nu med din kommentar. Så om du verkligen vill visa ditt missnöje så ska du inte klicka på ogilla eller gilla och du ska inte kommentera. Då får videon ingen reach.
Vi fattar alla (inte du uppenbarligen) att detta är ett projekt som är bättre i tanken än i verkligheten. Ändå tar sig Rickard tiden att göra det. Ja avgasröret ska vara ut genom väggen istället! Alla fattar det.
För att sammanfatta. Om du inte gillar en video, håll käften. Det gynnar dina och (som en bonus) våra intressen.
Bel progetto
⚡ *Ragnar!* ⚡
Ma soffocare così in verticale
Non ti ha sporcato precocemente il bruciatore ?
Rimane comunque un bel progetto
Peccato che Per riscaldare casa
Così il bruciatore non sia il massimo
Troppi fili è bruciatore troppo esposto
Io ho risolto da 4anni isolandolo all'esterno
Prelevando aria dall'interno entra nel cinebasto
È col tubo da 8 sparo dentro casa
Sempre acceso da novembre a marzo al minimo
È ci riscaldo 85mq ventilando tra ambienti forato da ø15 i muri è messi dei volgari ventilatorini USB da 5w pagati niente è super silenziosi
Altro che canalizzare !🌹
*La pompetta ti si inchioda perché va tenuta appesa è inclinata di 35°*
PS: comunque non sei riuscito a silenziare la pompa malefica 😂
Vad är nu detta...Stumfilm...Du har tappat tråden nu Rickardo!
Blir helt ointressant med sporadisk å felöversatt textning
Tror att han är förkyld kanske
Oja jorden går under nu gå hem och böla med dig.
”Tappat tråden?” Han är smartare än dig iaf, för du vet uppenbarligen inte vad som gynnar dig. Han gjorde en liknande video för bredare publik för ca ett år sedan. Den har han nästan en miljon visningar på(till skillnad emot vanliga snittet på ca 40-45k) = fler tittare = mer pengar = mer inköp av verktyg och maskiner som han kan testa, mer reservdelar, mer inköp av projekt = fler recensioner av verktyg och maskiner och fler ”vanliga” videos för dig att titta på och lära dig av. Det är ingen som dör av några såna här videos om året, det snarare gynnar alla som tittar på hans kanal.
Rickard tyst i 20 min, nånting är fel :D
Sikken god ide de där. Tack.
kavitation i pumpe , 45 grader så funker den igen
As another subscriber said (A) for effort, but it seems to me that you’ve wasted your time by doing this. The original heater probably put out more heat and was safer by the exhaust being exhausted to the outside of the Building. it would be better to leave the heater, blowing the hot air into the building and the exhaust running through the radiator and being exhausted outside that may increase the heat value and certainly won’t kill you of carbon monoxide poisoning
Any idea what the btu output is for this mod vs the output of the original design?
Ännu en Vevor Diesel Värmarvideo, dom måste betala riktigt bra😁
Bonjour,
Super invention !
Quand j'ai vu la découpe du bloc aluminium j'ai eu peur 😊
Quel est le poste à souder que vous utilisez svp ?
Merci pour le partage de cette invention.
Bien à vous
Godmorning. I use a normal Mag welder 160Amp.Thanks!
detta klipp påminner om jetmotorn som Colin Furze byggde för längesedan av en toaborstshållare och en gammal turbo. något du hade kunnat göra kanske. hade varit sjukt fett! B)
If you don't want the bubbles, you need to mount the pump vertically (80-90 deg)
Snyggt Rickard! Men du måste ju snacka med oss! :D
Would an old car radiator work better? It's smaller, thinner and a Whole lot lighter.
Pump needs to be at a 45 degree upward setting ...
It will be easier and efficient more if you connect the exhaust to your oil heater
Then you must have a oil heater 😉
Vilken modell av vevor värmekamera har du?
Kolla på länken i beskrivningen av filmen
Missade det, tack för hjälpen 👍
Herre gud, ska man ha en sådan mackapär i varje rum, hur gick det med den tidigare vevorvärmaren, tacka vet jag värmepump.😵😵💫
En i varje rum?!! Du har ganska stora rum va eller ska du bygga bastu? 😏
Varför har du tagit bort alla ryobi dekaler på alla maskinerna?
säkert slut på sponsring
Står ju på batteriet? De är mer ”clean” att köra utan loggorna 🤓🤓
Hej du. Har du provat ta isär en yttre drivknut till bil och sätt ihop den igen?
Många gånger, det är mkt enkelt 😀
En tyst video, då får du förhoppningsvis ökning av tittare vilket säkert inte är fel. Lycka till.
I don't understand what you did with the exost outake. Where is it going. What about carbon monoxide
Är det här ett försök till att nå ut till dina tittare internationellt? Saknar ditt snack om vad som är på gång eller vad som är planerat. Tyvärr lite som att se Pakistanska gatuverkstäder som renoverar eller tillverkar otroliga saker. Kul och se, men saknar "Hej och välkommen till mitt garage"😁
Greetings from Finland. My second language is Sweden and still in most cases I miss the point of what he is doing in his normal videos. This is way better in my book.
You do realize that you are just absorbing the heat already being put out by the heater right ?? If you want to capture wasted heat run the exhaust of the heater through the radiator and then outside. You will then have the heat recovered from the exhaust and the heat blowing in the room from the heater.
Great idea, but this is very dangerous. If someone recreates this, they could die from all the carbon monoxide. This is not a joke, and this video should include a warning about it or be taken down. I respect that you want easy views and money, but giving people carbon monoxide poisoning isn’t the way.
If some do not see the danger of burning something inside your house or garage without proper ventilation or filtering, I call it nature's choice if something goes wrong. These are not for education.
@@Teknopottu exactly it common sense that he is using the excess exhaust heat and the exhaust should be vented properly from someone that is knowledgeable enough to take on this project.
I want one.
Det där tog emot fysiskt och psykiskt att vara tyst. Kul
Fin sag du har a? sånn vil jeg ha plass til i sjappa mi og!
Den tar ikke verst mye plass.
Dom engelska översättningarna får du nog jobba på.
I dont understand why people put videos on here and dont know the BASIC set up of these heaters.... ie full pump angle, exhaust angle and condense draining.
1 90% of the people don't have the tooling to make this . 2 the fuel pump needs to be at 45 degrees and the exhaust to be piped outside
Error Code 8
Turn Fuel Pump on ANGLE 30-40 degrees eliminates Air Bubbles
Silly Build Project 😂
No need to Butcher the Heater to achieve same result.
Use old Tractor Radiator
Use Flexible Aluminum or Steel Output Air Pipe into Tractor Radiator.
Use 12v Electric Radiator Fan to Blow Air thru much smaller fins creating more BTU and better regulated heat.
Project creates much better warm air flow
1/4 the effort
3/4 better results.
Engineering Guru.
Wouldnt it have been more efficient to just run the exhaust through the radiator so you still have a working heater and a radiator
I likes it
The radiator will fill up with water and carbon my friend , it wont work long term
Hello dommage pas de contrôle CO et CO2 en sortie de cheminée
Interesting, CO, CO2, has no oder, right?
😊ser gärna att du pratar svenska som vanligt.Det är inte lätt att hänga med. Du är så pedagogisk vanligtvis.
Så många fel i den videon.... Men vi är så få som märker det... 💯
Ja, alla är vi olika...
Instead of cutting it in half you could have given it to me! I would have provided it with a good home.
E sufficiente fare attraversare il tubo di scarico fumi, all'interno della parte bassa del termosifone. L'acqua all'interno del termosifone si riscaldera, sfruttando l'alta temperatura del tubo di scarico. mentre l'aria del cinebasto riscaldera un altro ambiente
Snart har varenda garagejocke slaktat en vevor
❤️👍👍👍
El ventilador no hace nada al quitarle el plastico ya que no lo dirige
fy fa,,, mangler din stemme... har du fået halsbetændelse ?? - fortsat god leg med ting og sager.. hilsen ifrån Danmark. ;-)
Came here to write this. Better this way in my book. Miss most of what he says in his normal videos anyway. Greetings from Finland.
Gratis energi?
I’m no expert, but I think you might have voided the warranty on that heater now.
Why are you destroying the heater!!!!
Klick video med Free energy trams som inte finns. Förstår är att är sugen på mer sub, klick och pengar men detta är ett lågvatten märke.