* Is the motor on delta or star connection ?? * If star connection on your motor is 380 v and you connect the star connection ... Does this affect the torque of the motor or not ??? * What is meant by input 240 v single phase and the output is 240 three phase as i found this in many VFDs ?!?! And please tell me more about the motor description plate and the VFD manufacture details 😊😊 Thank you ❤️i loved that you used the avometer to confirm your connections 👌👌
Hello i have VFD delixi 11kw. how can we connect the pressure switch to VFD so that it will automatically start if the air is low? please reply THanks.
Hello Sir, I need your help, please. I have air compressor 10hp, and i bought the VFD 11kw. Input is 220v output 380v 60hz. I know the wiring is R T for input and U V W for output. How about for the air pressure sensor wiring how to hook up to VFD for automatic ON and Off? Hoping you can help me, please.
I need manual book inverter input 1phase 220volt to 3 Phase 220vt .I can't setting because I not have manual book. can you help me send manual book to me?
Why star connection at the input of motar...why not delta?
What is the wire size for the uvw in this vicdeo? Can I use 5.5sqm THHN wire?
How number diode zener to igbt?..my inverter short diode..
Sir agr 10 hp 220 par chale to 220 par amp kia ho ge
Bang itu ga pake resistor brake ap gpp?
What does it mean when the ECOGOO 9100 shows 0CH as an error? code is not in the manual. thank you
Please set P1.29=1 back to factory settings ,and send to my email johnpei2012@foxmail.com
Kalu boleh tau apa merk nya dan belinya dimana, makasih
If I have input voltage less than 380 volts. Then would the vfd drive run the motor at lower frequency or just trip?
price kya h sir
* Is the motor on delta or star connection ??
* If star connection on your motor is 380 v and you connect the star connection ... Does this affect the torque of the motor or not ???
* What is meant by input 240 v single phase and the output is 240 three phase as i found this in many VFDs ?!?!
And please tell me more about the motor description plate and the VFD manufacture details 😊😊
Thank you ❤️i loved that you used the avometer to confirm your connections 👌👌
The 380V is star connect . this one is single phase 220V input ,3 phase 380V output ,can you send to my email ? johnpei2012@foxmail.com
@@johnpei5400 10hb moter and adr 15hb amposepil
@@naseerkhan3268 can you take a photo about the nameplate and send to my email ? johnpei2012@foxmail.com
@@johnpei5400 a.o.a
Hello i have VFD delixi 11kw. how can we connect the pressure switch to VFD so that it will automatically start if the air is low? please reply THanks.
x4 and common
you have to change one parameter
Hello Sir, I need your help, please. I have air compressor 10hp, and i bought the VFD 11kw. Input is 220v output 380v 60hz. I know the wiring is R T for input and U V W for output. How about for the air pressure sensor wiring how to hook up to VFD for automatic ON and Off? Hoping you can help me, please.
Sir paleez one kowischan single fas 220enput adr three fas 11kv ka VFD 10hb moter dariv amposepil
Can u please let me know What are the specifications of drive
Please send to my email johnpei2012@foxmail.com
I have 2 hp 3phase moter
Which vfd is required sir
N from where I can purchase it
No need of adjusting speed
The link for this product : www.aliexpress.com/item/32800613734.html?storeId=2949111&spm=2114.12010612.8148356.51.3b671298bA5d4B
Can you help me sir
I need manual book inverter input 1phase 220volt to 3 Phase 220vt .I can't setting because I not have manual book. can you help me send manual book to me?
Bro Can It Run 10Hp Motor
PLEASE Reply Me Fast...
Yes ,it will be ok
@@johnpei5400 10 hb mother dariv be VFD11kv
Nice video but subtitle update
Electro type apa ya
Hello, three phase motor power
YES
this link is the same 220V to 380v VFD www.szkarda.com/en/product/products-0-12.html
What is the wire size for the uvw in this vicdeo? Can I use 5.5sqm THHN wire?