Siemen's SIPART PS2 Manual Calibration ! SIPART PS2 Calibration in Hindi

แชร์
ฝัง
  • เผยแพร่เมื่อ 16 มิ.ย. 2019
  • Today I'm here explained that how to calibrate a siemens SIPART PS2 smart positioner in “ Manual Mode ”.
    This is the only video on TH-cam explaining Manual Mode calibration exclusively for you guys so please watch carefully.
    Also I request you to please share this special video and comment if there is any doubt/trouble during calibration.

ความคิดเห็น • 158

  • @unfilteredwithprakash6970
    @unfilteredwithprakash6970 4 ปีที่แล้ว

    Sir, nicely explained, impressive. Keep doing such great work

  • @sreenubabu6488
    @sreenubabu6488 3 ปีที่แล้ว

    Thank you my friend..good job and very useful information

  • @pareshrathod1482
    @pareshrathod1482 4 ปีที่แล้ว +1

    Thank you very much for great video
    Good work bhai

  • @vinaysane5435
    @vinaysane5435 ปีที่แล้ว +1

    Excellent Sir & Very Thanks for showing how to calibrate Siemens Sipart PS 2 Positioner.
    Very Thanks Sir.
    💐💐💐💐💐💐💐🙏🙏🙏🙏🙏🙏🙏

  • @sureshkumarverma5094
    @sureshkumarverma5094 3 ปีที่แล้ว

    Thank you very much . Good information.

  • @Ram-sx5mv
    @Ram-sx5mv 3 ปีที่แล้ว +1

    बहुत बहुत धन्यवाद भैया ये वीडियो बहुत helpful ह मेरे लिए ओर भी वीडियो बनाओ
    God bless u sr💐💐

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 ปีที่แล้ว +1

      शुक्रिया, आपका आशिर्वाद बना रहे 🙏🙏

    • @Ram-sx5mv
      @Ram-sx5mv 3 ปีที่แล้ว +1

      @@shantilaldhakar9967 भगवान से प्राथना करते ह आप हमेशा तरक्की कर ऐसे ही लोगो का भला करते रहे हेल्प करते रहे🙏💐😊

  • @vthls
    @vthls 5 ปีที่แล้ว

    Comprehensive! Thank you sir..

    • @shantilaldhakar9967
      @shantilaldhakar9967  5 ปีที่แล้ว

      You are welcome

    • @pravinchavda9226
      @pravinchavda9226 4 ปีที่แล้ว

      Plz ...any vacancy for Instrument technician I am diploma in instrumentation and control engineering with 8year experience.plz give me your WhatsApp number...Pravin CHAVDA Gujarat Jamnagar

  • @Marafeq344
    @Marafeq344 2 ปีที่แล้ว +2

    Thank you for the video

  • @himmatgarg2239
    @himmatgarg2239 5 ปีที่แล้ว

    Wa. Bhai .. Superb....

  • @mr.nizamulhoq851
    @mr.nizamulhoq851 4 ปีที่แล้ว

    excellent and so more helpful presentation

  • @vinaysane5435
    @vinaysane5435 9 หลายเดือนก่อน

    Very Good &Knowledgeable Video.👍👍👍👍👍💐💐💐💐💐🙏🙏🙏🙏

  • @kishoreKumar-wt4vi
    @kishoreKumar-wt4vi 4 ปีที่แล้ว +1

    Thanks ji for good posted. please do more videos on Siemens positioner troubleshootings also.

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 ปีที่แล้ว

      Thanks for appreciation and I will accept your feedback regarding video on troubleshooting.
      Thanks again...

  • @Hewagej
    @Hewagej 2 ปีที่แล้ว +1

    Very good video
    Thank you so match

  • @rajeshsinghcimac
    @rajeshsinghcimac 4 ปีที่แล้ว +1

    Thanks a lot. nice presentation. (y)

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 ปีที่แล้ว

      Sir, Thank you very much for your appreciation.
      I'm glad that my small video is helping thousands of people across the globe which was my main Moto for this upload.

  • @BhagwanSingh-sv3kh
    @BhagwanSingh-sv3kh 2 ปีที่แล้ว

    Thank you helpful video

  • @waqashabib1674
    @waqashabib1674 4 ปีที่แล้ว +2

    Nice representation, done the same and valve was properly calibrated

  • @aamirkh4064
    @aamirkh4064 2 ปีที่แล้ว

    Thank you very much

  • @iqbalmehedi3423
    @iqbalmehedi3423 4 ปีที่แล้ว

    how can i attach a position feedback module?

  • @sunilrathod663
    @sunilrathod663 11 หลายเดือนก่อน +1

    Thanks bhai

  • @rajarajan6291
    @rajarajan6291 4 ปีที่แล้ว

    Good job

  • @manikr9465
    @manikr9465 3 ปีที่แล้ว +1

    It was good informative video that who worked in instrumentation filed especially in fild side.if you possible plse put more different type of positioner configuration and caliberation. For instance azbil

  • @surajkumarkhunte1181
    @surajkumarkhunte1181 2 ปีที่แล้ว +1

    thank you

  • @kunalpareta5908
    @kunalpareta5908 2 ปีที่แล้ว

    Great job 👍

  • @MdAli-vg2ko
    @MdAli-vg2ko ปีที่แล้ว

    Nice

  • @hadiyalshailesh9748
    @hadiyalshailesh9748 4 ปีที่แล้ว +1

    Good

  • @AshokPrajapati-ec3qh
    @AshokPrajapati-ec3qh 2 ปีที่แล้ว

    Good sir

  • @madhavrabari4756
    @madhavrabari4756 2 ปีที่แล้ว

    🙏 Thanks 🙏

  • @PradeepKumar-qk3qo
    @PradeepKumar-qk3qo 3 ปีที่แล้ว +1

    Good work

  • @abhijitpadhiary4349
    @abhijitpadhiary4349 3 ปีที่แล้ว +1

    Thank you 🙏, Nicely explained.

  • @pushpasahu1910
    @pushpasahu1910 4 ปีที่แล้ว

    Sir Forbes Marshall positioner ka callibration ka video bnaeye

  • @dalimnath614
    @dalimnath614 3 ปีที่แล้ว +1

    Thank you

  • @soumyaranjanjilu7816
    @soumyaranjanjilu7816 2 ปีที่แล้ว

    Thanks for this video bt sipart ps2 all models calibration plz video make

  • @Ajayyadav-nh3qb
    @Ajayyadav-nh3qb ปีที่แล้ว

    how to set her feedback deviation

  • @himanshushekharpandey7186
    @himanshushekharpandey7186 6 หลายเดือนก่อน

    Thnx via

  • @devispatel50
    @devispatel50 4 ปีที่แล้ว

    👍

  • @jitendrakumarsahu4087
    @jitendrakumarsahu4087 4 ปีที่แล้ว +1

    Parameters ka video banaye plz

  • @jitubabusay2826
    @jitubabusay2826 หลายเดือนก่อน

    19 mA mai 100% open karna hai to kya kare please batayiye

  • @402san
    @402san 4 ปีที่แล้ว

    y end 1&2 ka limit set krne k liye - aur + ko ek saath press krna he kya

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 ปีที่แล้ว

      Press & hold “ - ” button and note that control valve is fully closed, set it as your “ Yend 1 limit”.
      Similarly, press & hold “ + ” button and note that control valve is fully opened. This will be your “ Yend 2 limit”.

  • @PradeepKumar-qk3qo
    @PradeepKumar-qk3qo 3 ปีที่แล้ว

    Eska full video dekhao with industry ka sir

  • @mdfarhan3259
    @mdfarhan3259 4 ปีที่แล้ว

    Sir hm jb bhi esko calibrate karenge manual mode me le Jake hi krenge.auto me nhi Kar sakte hai kya

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 ปีที่แล้ว +2

      Auto mode me bhi kar sakte hai.
      Parameter no. 4 access karke “ + ” button Ko 5 seconds k liye hold karo to auto calibration start ho jayega.
      Also I had made a seperate video for auto calibration procedure so please watch that stuff on my TH-cam channel.
      Thanks

  • @GauravKumar-xu9gh
    @GauravKumar-xu9gh ปีที่แล้ว

    I have confusion for parameter 7 and 38 could anyone can explain please.

  • @haidarquarrar8848
    @haidarquarrar8848 ปีที่แล้ว

    Sir auto calibration me run 2 me fans jaraha aur P 8.1 uske niche fault ka symbol and up 1 show kar raha Hai kaise setting karenge

    • @shantilaldhakar9967
      @shantilaldhakar9967  ปีที่แล้ว

      Valve is either jam or may not open/close properly.
      There may be air leakage from seal/diaphragm in output side.
      Check for these issues

  • @thomaselsen1672
    @thomaselsen1672 2 ปีที่แล้ว

    after a manual calibration, i am getting a negative number on the positioner display because the valve is seating which is desired but the negative number is not. How do i make the display read zero when going under the lower set point of the manual calibration?? Please Help!

    • @shantilaldhakar9967
      @shantilaldhakar9967  2 ปีที่แล้ว

      Your Positioner is mounted on which system i.e. Air to open/close actuator or power cylinder?
      Case 1: If ‘Air to Close’ type pneumatic actuator then check air pressure and ensure that it does not exceed specified limit.
      Case 2 : If power cylinder then you adjust through cushioning screw.
      And then repeat manual calibration procedure as explained in this video.

    • @thomaselsen1672
      @thomaselsen1672 2 ปีที่แล้ว

      @@shantilaldhakar9967 it is a fail to close valve. On a diaphragm actuating control valve. The system set points requires the valve to jump up to 20% open as soon as any Ma signal is applied. So the valve was manually calibrated to set the lower limit to that 20% open so when Ma is applied it would automatically go to 20% open and achieve desired set points. Since the new 0% is manually calibrated to 20% open and the positioner closes the valve all the way to its seat once it gets the close signal. the display will read a negative number now because it thinks it is -20% to the seat. I was wondering if there is any way to zero that number out on the display or a better way to set up that valve to be able to achieve those set points. Thanks for the Help.

  • @vipulgp9843
    @vipulgp9843 4 ปีที่แล้ว +1

    auto caliberation ke time run2 me up 1 error dikha raha hai....kya problem ho sakta hai???

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 ปีที่แล้ว

      It's upper limit or open limit is not in the range that's why that error arises.
      So adjust the feedback positioner link with control valve and adjust in open condition with the help of friction clutch gear available on positioner.

  • @atanuhalder322
    @atanuhalder322 4 ปีที่แล้ว

    Sir my calibration is running at run4 continuously is not going at run5 please help me

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 ปีที่แล้ว

      Dear friend,
      RUN 4 step during calibration “ Determine the minimum increment length ” means positioner will increment command by smaller fractions in decimal points & simultaneously check feedback and if it doesn't match then positioner stucks in RUN 4.
      Solution::
      (A) There may be leakage from fittings/diaphragm so check all fitting tightness.
      (B) The position FB link may be loose so check tightness.
      And then calibrate again you will definitely success.
      Thanks for your query and I hope this information helps you a lot.

  • @haidarquarrar8848
    @haidarquarrar8848 2 ปีที่แล้ว

    Open karne keliye EK button ya do boton EK sath push karna zaruri Hai kya

    • @shantilaldhakar9967
      @shantilaldhakar9967  2 ปีที่แล้ว

      Single button se slowly open hoga
      and Two buttons ek sath press karne se fast open hoga.

    • @haidarquarrar8848
      @haidarquarrar8848 2 ปีที่แล้ว

      @@shantilaldhakar9967 thank you sir for reply

    • @haidarquarrar8848
      @haidarquarrar8848 ปีที่แล้ว

      Sir EK problem Araha Hai valve auto calibration karne ke baad bhi valve 20 % hai aur command bhi 20 % araha Hai auto mode me lekin dcs me 0%show kar raha Hai valve kya karun ki valve fully close hojayye valve hamara fail to close Hai

  • @RizwanAhmad-wg6fs
    @RizwanAhmad-wg6fs 4 ปีที่แล้ว

    How to solve hunting and overshoot problems. There is no tube leakage but also hunting.

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 ปีที่แล้ว

      Check air leakage after positioner output from tube joints and actuator diaphragm.
      If this check is found normal then check the feedback positioner link connection. It may be loose or very tight so adjust link and properly tight again.
      After all that please make positioner calibration, I think your problem will get resolved.

  • @SonuKumar-ju2ok
    @SonuKumar-ju2ok 2 หลายเดือนก่อน

    Zero karne ke liye bhi +ve and -ve button ek sath press kar rahe h and 100 karne ke liye bhi same kar rahe h ?

    • @shantilaldhakar9967
      @shantilaldhakar9967  2 หลายเดือนก่อน

      Action fast karne k liye Aisa Kiya ha.

    • @shantilaldhakar9967
      @shantilaldhakar9967  หลายเดือนก่อน

      +ve button press & hold and then press -ve button
      In this way your action become fast.

  • @nikhilkapoor4561
    @nikhilkapoor4561 2 ปีที่แล้ว

    Positioner display is not getting power on ....22 v DC ... What will be the solution

    • @shantilaldhakar9967
      @shantilaldhakar9967  2 ปีที่แล้ว

      If power is healthy then it's interface card may be faulty.
      Solution: Contact to supplier/vendor for repairing/replacement.

  • @RamSingh-nj8mr
    @RamSingh-nj8mr 2 ปีที่แล้ว

    If positioner not operate in manual mode & not vary the opening percentage during manual command from positioner
    Plz help & how to contact you

    • @shantilaldhakar9967
      @shantilaldhakar9967  2 ปีที่แล้ว

      My contact number 8003228484

    • @shantilaldhakar9967
      @shantilaldhakar9967  2 ปีที่แล้ว +1

      May be air supply pressure is not sufficient or control valve/actuator is mechanically jammed.

  • @sbibhureddy2255
    @sbibhureddy2255 3 ปีที่แล้ว

    Me Ra ek positioner auto/manual calibration nehi leraha he. Next Kia karunga

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 ปีที่แล้ว

      Please what's app your query/screenshot of error so that I may help you in a better way.
      What's app number 8003228484

  • @instrumentpower6380
    @instrumentpower6380 2 ปีที่แล้ว

    सर मैं जैसे ही End1 देकर hand press कर रहा हूं Range लिखा आ रहा है End 2नही आ रहा है क्या चेक करू

    • @shantilaldhakar9967
      @shantilaldhakar9967  2 ปีที่แล้ว

      “Range”means your range selected in “End1” or “End2” is incorrect. Please set it inbetween 10% to 85% at zero and span respectively. 👍

  • @pradipkumaryadav252
    @pradipkumaryadav252 3 ปีที่แล้ว

    If 41 blinking on screen then what will do

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 ปีที่แล้ว

      Check the Instrument air pressure, if it is not sufficient to open/close valve then this error occurred 👍

  • @hooshangalizadeh637
    @hooshangalizadeh637 3 ปีที่แล้ว

    how to adjust the display contrast ?

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 ปีที่แล้ว

      please share details/model no. of your Siemens positioner.
      It will be like “ 6DR5051 or 6DR5052” .

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 ปีที่แล้ว +1

      I had gone through the positioner manual but did not find any information about contrast control.
      FYI 👍

  • @sajidaziz2862
    @sajidaziz2862 3 ปีที่แล้ว

    AoA
    sir my control valve ps2 positioner continue stuck on RUN 5 but not show finish option please giuide me

    • @sajidaziz2862
      @sajidaziz2862 3 ปีที่แล้ว

      if stroke 20 mm then we select 90 or 30
      but now i select 90 and selector switch on 90 same as follow in parameter 2 according to manual

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 ปีที่แล้ว +1

      @@sajidaziz2862 please select 33° angle and then lock that position at 33°.

    • @sajidaziz2862
      @sajidaziz2862 3 ปีที่แล้ว

      ok i will try now

    • @sajidaziz2862
      @sajidaziz2862 3 ปีที่แล้ว

      @@shantilaldhakar9967 sir but when we select 90??if stroke is more than 20??

    • @sajidaziz2862
      @sajidaziz2862 3 ปีที่แล้ว +1

      @@shantilaldhakar9967 Thanks for guidelines my job is done.

  • @Diwa94
    @Diwa94 ปีที่แล้ว +1

    up and down dono saath me push karte ho , ye to bolte nhi ho

  • @kirtandas1974
    @kirtandas1974 3 ปีที่แล้ว

    Sir ek problem hai 100% command pe 66 % arha hai... Input
    Kya kare
    12 no parameters me ja ke chenge kar ke dekh liya par ho nahi rha .
    Please iska kya problem hai btae

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 ปีที่แล้ว

      Factory reset your positioner and then re-calibrate in manual mode. If you got any issue then feel free to comment regarding problem.

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 ปีที่แล้ว

      RESET :: Go to parameter no. 50 and then press and hold “+” button for 5 seconds. This action will factory reset your positioner.👍

    • @Pawankavlog24
      @Pawankavlog24 ปีที่แล้ว

      @@shantilaldhakar9967 sir mere positioner me zero command dene pe 20% command aa rha h to kya problem hoga command zero nhi aa rha

  • @tariqueanwer9329
    @tariqueanwer9329 2 ปีที่แล้ว

    Sir mera actuator 0mm tk close nahi ho raha hai please help

    • @shantilaldhakar9967
      @shantilaldhakar9967  2 ปีที่แล้ว

      Check your actuator specification and if it is air to close type actuator then set air pressure.
      Also, you may set pressure 5-10% higher than rated pressure.
      Secondly, if above things checked and ok but problem not resolved then ensure that actuator spring tension is ok or not.
      It may be due to high spring tension of actuator so adjust it properly. 👍

  • @sbibhureddy2255
    @sbibhureddy2255 3 ปีที่แล้ว

    Siemens positioner ko kese single action karenga.?

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 ปีที่แล้ว

      Make one output lower side port dummy and connect connect control valve to the remaining port.

  • @manekmanek2617
    @manekmanek2617 4 ปีที่แล้ว

    Good brother what about hantting

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 ปีที่แล้ว

      Hunting problem caused due to these possibilities ::
      1. Instrument air pressure drop after positioner output by any means including ALR failure or air leakage problem.
      2. If the spring tension is loose than required then it happens.
      Thanks for appreciation and query.

  • @odishabirdlovers3827
    @odishabirdlovers3827 ปีที่แล้ว

    Mera position reverse may kam kar rahahey kya karu

    • @shantilaldhakar9967
      @shantilaldhakar9967  ปีที่แล้ว

      Check parameter no. 7 and select proper parameter i.e. “rise” or “fall”.
      Your problem will be resolved.

    • @odishabirdlovers3827
      @odishabirdlovers3827 ปีที่แล้ว

      @@shantilaldhakar9967 thanks

  • @jitendrakumarsahu4087
    @jitendrakumarsahu4087 4 ปีที่แล้ว

    VEnd2 ke baad Range ka option aa rha hai , calibration nhi hota hai ,,kya kru bataye

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 ปีที่แล้ว

      Please adjust the zero and span range and accordingly it's feedback too.
      The difference must be greater than 80% and then calibrate using above explained procedure.
      Thanks buddy

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 ปีที่แล้ว

      Operate the valve using + & - buttons on positioner and set Feedback 0 at zero check and atleast 80 to 86 at span check.
      Then calibrate the positioner in auto/manual mode.

    • @jitendrakumarsahu4087
      @jitendrakumarsahu4087 4 ปีที่แล้ว

      @@shantilaldhakar9967 span and zero kaise set kare? Hindi me bataye sir

    • @jitendrakumarsahu4087
      @jitendrakumarsahu4087 4 ปีที่แล้ว

      @@shantilaldhakar9967 Jab Range ka Option aata hai us time + button press karne se Vend2 aa jata hai fir se

  • @sagarmali8393
    @sagarmali8393 ปีที่แล้ว

    What is meant by U- di error

    • @shantilaldhakar9967
      @shantilaldhakar9967  ปีที่แล้ว

      means positioner feedback is inappropriate with respect to command signal.

    • @shantilaldhakar9967
      @shantilaldhakar9967  ปีที่แล้ว

      futher you may adjust it by roller gear mounted just below display.

  • @8899122246
    @8899122246 2 ปีที่แล้ว

    Feedback kaise set krenge

  • @mrinmoysahoo8626
    @mrinmoysahoo8626 2 ปีที่แล้ว

    Agar run 1 ya run 4 ma error ageya to kya karna chahiye

    • @shantilaldhakar9967
      @shantilaldhakar9967  2 ปีที่แล้ว +1

      Error in RUN 1 means either actuator/power cylinder is jammed or air pressure is not sufficient.
      Please check air pressure, pressure seal condition and jamming of valve/actuator.

    • @mrinmoysahoo8626
      @mrinmoysahoo8626 2 ปีที่แล้ว

      @@shantilaldhakar9967 thanks

    • @mrinmoysahoo8626
      @mrinmoysahoo8626 2 ปีที่แล้ว

      Or run 4 kya matlab hai

    • @shantilaldhakar9967
      @shantilaldhakar9967  2 ปีที่แล้ว +1

      @@mrinmoysahoo8626 It's my pleasure to help you 😊

    • @shantilaldhakar9967
      @shantilaldhakar9967  2 ปีที่แล้ว

      @@mrinmoysahoo8626 RUN 4 : Positioner check and determine the minimum increment length so if error means there may be air leakage through actuator/power cylinder pressure seal parts.
      Please check and ensure that their is no any such leakages. 👍

  • @parmarashvin3993
    @parmarashvin3993 3 ปีที่แล้ว

    Sir ye 90°And 33 ° me kush samj nahi aa raha kush jyada jankari de sakte he please... Sir...

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 ปีที่แล้ว

      In case of linear actuators, if valve stroke is less than 20 mm then we select 33° transmission ratio else for valve stroke more than 20 mm we select 90°.

    • @parmarashvin3993
      @parmarashvin3993 3 ปีที่แล้ว

      @@shantilaldhakar9967 ok thank you sir

    • @mayankparmar4850
      @mayankparmar4850 3 ปีที่แล้ว

      Muje bi isme samaj nahi aaraha hy

  • @SurenderSingh-sk3kn
    @SurenderSingh-sk3kn 3 ปีที่แล้ว +1

    Bhai maan ge chorre

  • @alijee4876
    @alijee4876 4 ปีที่แล้ว

    Yar agir new install karna hai tu kary ga

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 ปีที่แล้ว

      Same procedure will be followed for newly installed positioner.

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 ปีที่แล้ว

      Please share your email ID so that I may help you by providing sufficient documents.
      Thanks

    • @alijee4876
      @alijee4876 4 ปีที่แล้ว

      alijee.aj137@gmail.com

  • @parmarnil4748
    @parmarnil4748 3 ปีที่แล้ว

    0 jaga pe 100%dikhae और 100 % जगा 0 dekha to kya karne ka

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 ปีที่แล้ว

      केवल फीडबैक गलत आ रहा है या कंट्रोल रूम से कमाण्ड ही गलत आ रही है।

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 ปีที่แล้ว

      Check parameter No. 7 and 38.
      If position feedback is just reverse then change parameter no. 38 from rise to fall and vice versa.
      And if command signal is reverse then change parameter no. 7 as explained above.
      I hope you got solution, further feel free to contact if you have any query.
      Thanks

  • @mayurparmar104
    @mayurparmar104 5 ปีที่แล้ว

    Control valve mera open hai to zero dikha raha hai.. Or close hone par 100 dikha raha esa kyu

    • @shantilaldhakar9967
      @shantilaldhakar9967  5 ปีที่แล้ว +1

      Please check perameter no. 7 & 38 both parameters must be selected “ rise ” instead of “ Fall ” and then calibrate in manual mode as described in this video.
      I hope your problem will be resolved.

    • @kishoreKumar-wt4vi
      @kishoreKumar-wt4vi 4 ปีที่แล้ว

      Yes correct ji.

  • @sreenubabu6488
    @sreenubabu6488 3 ปีที่แล้ว

    Friend if possible English language

  • @PradeepKumar-qk3qo
    @PradeepKumar-qk3qo 3 ปีที่แล้ว

    Can you learn me sir ji

  • @bhagwansinghlodha939
    @bhagwansinghlodha939 2 ปีที่แล้ว

    kavi kavi error aati h calibration nhi leta h wo

  • @sambalpurisongsulhabaysi.8343
    @sambalpurisongsulhabaysi.8343 ปีที่แล้ว

    har waqt kya dono + aur - button ko press kar k karna padega...agar nahi to dono ungli se kyon chek dete ho...

    • @shantilaldhakar9967
      @shantilaldhakar9967  ปีที่แล้ว

      Har waqt nhi,
      Jab quick open ya close karna ho tabhi Aisa karn ha.

  • @janmuhammad2751
    @janmuhammad2751 2 ปีที่แล้ว

    Good