Mitsubishi PLC to PLC Communication over Ethernet
ฝัง
- เผยแพร่เมื่อ 27 พ.ย. 2019
- This function allows data communications between specified devices at the specified timing just by setting simple parameters from the engineering tool for the CPU module. Specify one device (transmission source) to one device (transmission destination). The communications are performed between the specified devices.
---------------------------------------------------------------------------------------------------------------------------------------------------------------
Program Sample At:
automationsolutions.tk/
automationsolutionz.blogspot....
Download Sample Section
--------------------------------------------------------------------------------------------------------------------------------------------------------------- - วิทยาศาสตร์และเทคโนโลยี
Man im loving this new simple plc communication. Makes my life so easy.
Thanks a lot for video!!! It helps me
Nice. Thank you .
Thank you sir. What is the fastest execution time setting possible for sending and receiving from one plc to another?
Super. Thank You
So does this work as communication between master and another master PLC ? And not under master-slave configuration.
Thank you for the informative video! Will these settings work for communication between Q and FX5U PLCs as well?
Yes it can work for all 3E Frame compatible devices
@@Technocrats91 Awesome! And thank you for the quick reply! Definitely going to subscribe!
sir Will these settings work for communication between fx5u plc with any other device??????
Superb ! Do you know how to communicate over Ethernet IP between AB Plc and Mitsubishi using Ethernet configuration tool , while I am using RJ71EIP.... Ethernet module , can’t actually figure out Class1 am Class3 tag communication!
Sure i will upload it soon
How many PLC can be connect ?
Can't find simple plc setting.. I am using gxworks3 version 1.038Q
Can this communication method work between Multiple set of QCPU + QJ71E71-100 and an FX5U?
Yes
Hi , please explain how to use this when Communication setting execution interval is set to "On Request" , instead of fixed
As of now communication setting is fixed only, You can use socket communication for On request communication
can we do this similar connection in gxworks 2 also?? and how its physical connection should be??
yes it is available in gxworks 2, for q & r cpu
sir Will these settings work for communication between fx5u plc with any other device??????
@ technocrats
Other devices which can communicate are mentioned in setting
OK thank you sir
@@Technocrats91 sir can you upload video of fx5u plc communication with other device ethernet communication setting?????
hi ! you can simulator communication fx5u and modbus tcp?
Not Possible
Hi. I can't to write to 1st PLC program. There is written: Simple PLC Communication Settings has been enabled.... :-(
I didn't get you, kindly explain
sir can we do both cclink and ethernet communication with same plc ????
Yes
how to do this in GX works 2?? can you show it for GX Works 2? please, thank you
Simple Plc communication is available for q plc and ethernet card.
Go to parameters, you will find simple Plc communication settings
I can not find "Simple PLC Communication Settings " in my GxWork3... How to add that?
Update Gxworks 3
@@Technocrats91 Çöynü, I have version GXwork3 1.0380 What version do you use?
1.055H
@@Technocrats91 I updated the GXwork3 and solved the problem. Thank you so much for your help
Can you guide me how to do this in Gx works 2 for fx3u PLC
FX3u Does not have simple plc communication function, you can use socket communication
@@Technocrats91 Thanks for your prompt reply But I don`t seem to find socket communication setting in gx works 2, my selected plc is FX3U can you kindly guide further?
contact me @ facebook.com/technocrats.nil.3
Do u have any tutorial for cc link
I will upload shortly
While doing this for fx5u and iq+r series it showing simple plc communication setting enable for that it is not write to plc suggest how to solve this
Simple plc communication require firmware version 1.210 or above, check your PLC's firmware version
This is for fx5u
For R cpu its firmware version 35
I checked with my place it showing 1.069
Update the firmware