@@Powerplantgeniusu said in ID fan , iD fan loading will rise, but in my plant no iD fan and so we can't peek inside superheater by opening manhole, so for FD positive draft furnace how to detect tube leak
1 Id fan ki loding bad jaegi , 2 aph ka inlet temperature girne lagega . 3 coal consumption bad jaega . 4 boiler me tez sound banega . 5 boiler ka draft fluctuate karega . 5 boiler ka pressure bhi disturb ho sakta hai jyada leakege hone per . 6 boiler water consumption bad jaega .
Gazzab ka knowledge hai aapka 👍👍👍👍👍
Thankyou dear
Nice information
Thanks
Knowledgeable video
Thankyou dear
Thanks
Welcome
Agar force draft hai in superheater, then how to make sure that it is superheater tube leakage
i cant understand your question, plese clear yur question
@@Powerplantgeniusu said in ID fan , iD fan loading will rise, but in my plant no iD fan and so we can't peek inside superheater by opening manhole, so for FD positive draft furnace how to detect tube leak
Kitne mw me aap kam ker rahe hain dost aur kon sa boiler hai , thoda clear karenge, then am telling your answer
@@Powerplantgenius interview question hai, superheater tube leak hua toh kaise confirm karoge...kaunse process parameters change hoge
1 Id fan ki loding bad jaegi ,
2 aph ka inlet temperature girne lagega .
3 coal consumption bad jaega .
4 boiler me tez sound banega .
5 boiler ka draft fluctuate karega .
5 boiler ka pressure bhi disturb ho sakta hai jyada leakege hone per .
6 boiler water consumption bad jaega .