Furnace Filter - Which Furnace Filter is Best?

แชร์
ฝัง
  • เผยแพร่เมื่อ 16 ก.ย. 2024

ความคิดเห็น • 534

  • @bikeriderful
    @bikeriderful 2 ปีที่แล้ว +22

    WOOD 5000!!!! HILARIOUS brother 🤣 😂 😆

    • @WordofAdviceTV
      @WordofAdviceTV  ปีที่แล้ว +1

      Lol glad you liked it man! 😄😄

    • @Jon-hx7pe
      @Jon-hx7pe ปีที่แล้ว +1

      @@WordofAdviceTV ya where do I buy the wood 5000 at 16x25x1? my high limit switch needs some exercise - wouldn't want it to get fat.

    • @animejanai4657
      @animejanai4657 ปีที่แล้ว +1

      @@WordofAdviceTV People buy at Costco with confidence. Since Costco has just the 3M Filtrete 2200 as well as their own Kirkland Signature 2200 equivalent, lots of people are using filters more restrictive than your Filtrete 300 or 600 filters. Maybe one day, you could include an updated furnace filter demonstration of the Filtrete 2200 and Kirkland 2200.
      You could even create a new video where you used all of your leftover filters until your manometer reading reached the point where you considered it was unacceptable such as 0.301 inches of water since you said normal filters should be within 0.10 to 0.30 inches of water. With the restrictive filters, it might be only a week before you decided the Kirkland 2200 filter was too plugged up! Who knew that Costco sold a filter that only lasts one week (per good restrictive air flow practice). Or you could test the filter longevity until it reached 0.50 inches of water in order to fit within equipment manufacturers' typical guidelines for pressure across the filter.

  • @thepacketnarc7634
    @thepacketnarc7634 3 ปีที่แล้ว +94

    For anyone wanting to skip to specific filters.
    4:15 Finally Untangles his leads for the meter
    6:05 Slightly Used 300 Amazon Filter
    6:54 New Fresh 300 Amazon Filter
    9:00 Poly Glass Fiber Filter (if you can even call it a "filter")
    11:00 600 Filtrete
    12:00 1200 Filtrete
    13:10 1500 Filtrete
    15:00 1900 Filtrete
    18:00 Demonstrating dirty filters from home with pets, high contaminant environment

    • @shellzdabest80
      @shellzdabest80 2 ปีที่แล้ว +3

      Thank you

    • @jonnyincognito899
      @jonnyincognito899 ปีที่แล้ว +2

      Not all hero's wear a cape 👍

    • @chodkowski01
      @chodkowski01 ปีที่แล้ว +1

      Engineers designed their units to use a merv 1 filter. I used a merv 1 filter for my 25 year old Trane A/C and never replaced any parts on it. I clean my A frame every year and to replace my unit I’m getting quotes of $5,700+ dollars. Is it cheaper to use a high merv filter and replace my A/C every 10 years.

  • @stevenvachon9745
    @stevenvachon9745 2 ปีที่แล้ว +115

    It's seems to me that there should be an indicator on the furnace that lights up when the air flow drops below a certain level, ie: when you need to change your filter, if it can cause damage to your furnace.

    • @dadgarage7966
      @dadgarage7966 2 ปีที่แล้ว +12

      That's what a manometer is for. Anyone can buy one and install them on their furnace like this guy did. Get a mechanical one -- no batteries, no electrical connection, etc.

    • @JohnDoe-gv9jv
      @JohnDoe-gv9jv 2 ปีที่แล้ว +3

      That is a great point. We need to invent that and sell it to homeowners. By the time you read this, they probably will already be selling them. I like this idea.

    • @stevenvachon9745
      @stevenvachon9745 2 ปีที่แล้ว +2

      I think there is an indicator on when to change your filter on some thermostats but they are based on hours of operation rather than air flow.
      I've had problems with my furnace not igniting but was pointed out that the filter was restricting air flow. It was a bit dirty but because it was a merv 11, it didn't take much to restrict air flow and the furnace is extra sensitive to this. Lesson learned and the idea was born.

    • @otallono
      @otallono 2 ปีที่แล้ว

      @@JohnDoe-gv9jv Duh, lots of things are like this. HVAC companies will lose money if they do this, so they don't. Why do you think we say all the time: They don't make them like they used to. World revolves around dollar signs. AC units don't even last as long as they used to, despite improved technology.

    • @michaelripplinger2169
      @michaelripplinger2169 ปีที่แล้ว +3

      Now, there you have it. Take the guess work out of when to replace the filter. No more reliance on a recommended interval (good guess) to protect your furnace. A permanently installed manometer would allow you to select a more protective filter and replace it when necessary, based real time time data. It could be blue tooth capable to alert your smart thermostat to shut down the system when damage is likely due to a dirty filter. Alerts through your smart phone, messages sent to Amazon to automatically order replacement filters, links to local air polution monitors recommending upgrading your filter to protect you from recent air quality threats, ie.local forest fires (Oregon). Dare I mention twiter?

  • @Monkeyseemonkey79
    @Monkeyseemonkey79 3 ปีที่แล้ว +46

    The 3M 1900 at 14:50 is the superstar filter. The key design feature is the number of pleats. It allows you to add MERV 13 filtration to your old HVAC without restricting airflow like most MERV 13 filters do. All allergy sufferers should be buying that filter. Just make sure you inspect it ever 4 weeks and plan to replace it every 8-12 weeks. Chances are the first time you run it in an old home, you will need to replace it after 2-4 weeks. After it has cleaned up your air by catching all the gunk in the first filter, the subsequent filters should last considerably longer.

    • @niameanspurpose
      @niameanspurpose ปีที่แล้ว +2

      thank you for sharing that! I have an old condo and the dust was crazzyyyy..i forgot to change the air filter..seems i need to do it once a month...didnt know it had to be cucled out...great tip!

  • @2explore1
    @2explore1 4 ปีที่แล้ว +30

    Your demonstration is the best one I've seen. Excellent clarity and easy to follow. Great demonstration explaining the static air pressures and restrictive issues with higher rating filters.

    • @coleyleclair
      @coleyleclair ปีที่แล้ว +2

      MERV rating is only half of it. The other half is surface area/pleats of the filter. The 1900 has way more pleats, which explains the low pressure drop.

  • @antmax
    @antmax 5 ปีที่แล้ว +12

    I was wondering about this. I had two capacitors die over 5 years and the last time I was told that the furnce door safety switch had melted and had to be replaced for $150, I went and had a look, found the switch had been bypassed with a solid core piece of insulated wire and the switch had melted into nothing. I ordered a new switch for $15 on amazon.
    I knew nothing about HVAC but am pretty handy and did a lot of practical electrical stuff as a kid at school in the UK. I can see how both these problems might be caused by using those 1500 alergy filters reducing air flow, heat build up and making more work for the blower hence capacitors dying.
    Thanks for your video. I only noticed the air seemingly cleaner for a few days after a filter swap with those expensive filters. And they certainly didn't last the full recommended lifecycle. I guess I will be getting the cheaper bulk filters and changing more regularly now too.
    Thanks for the excellent video.

  • @RyeGuy97
    @RyeGuy97 2 ปีที่แล้ว +16

    Great video and very helpful information. Thank you! One of the most insightful furnace filter videos I have found so far. I'm surprised that the "candle" filters were more clogged than the "pet" filter.

  • @BibleExposition2022
    @BibleExposition2022 4 ปีที่แล้ว +7

    I removed the grills and installed the fiber glass green filters at the intake location and inside the furnace. I used this filter since day one for 15 years and has no issue. If you change out the filter regularly, it will not make the coil inside the furnace dirty. My vent produce 50 degrees or lower temperature. About $3-3.25 for 4 at Walmart is excellent price for the green fiber glass filters. I recommend it highly because other so called premium filters restrict air flow, make the system works harder and caused even more electric bill.

  • @jhancock1575
    @jhancock1575 2 ปีที่แล้ว +7

    Great video. I check my filter once a month using a reminder on my calendar. I usually replace once a month it even if it’s little dirty. In rare situations, I’ll go 2 months. Filters never last what they claim on the label. Filter replacement is cheap maintenance.

    • @reck0n3r
      @reck0n3r ปีที่แล้ว

      What about electrostatic filters? We just had a geothermal unit put in that came installed with a pleated filter, but because it was a new install with higher air flow requirements, a lot of the prior dust/debris got pushed to the filter pretty early on and needed replacement within 2 months instead of the "rated" 6 months - to be expected for a new install I guess.
      But I've since ordered one of the same pleated filters for now, just to monitor initial energy usage with the unit to make sure it's running the way it should, but also got an electrostatic one that, according to the manufacturer, should last a lifetime, or 20+ years. Will put that in once I have an understanding of the power usage.

  • @themikeroberts
    @themikeroberts ปีที่แล้ว +10

    Your results show that the Filtrete 1900 is the least restrictive, which is what Filtrete shows on their packaging (which is now required thanks to California law).
    Here's Filtrete's Data:
    MPR 600: 0.24" pressure drop.
    MPR 1000: 0.23"
    MPR 1200: 0.26"
    MPR 1500: 0.22"
    MPR 1900: 0.19"
    MPR 2200: 0.21"

  • @keithcress1335
    @keithcress1335 4 ปีที่แล้ว +12

    Liked your thorough run down!
    I wanted to correct one misconception. It's this! The less filter restriction the MORE load the motor experiences. Not the common misconception that more restriction causes the motor to work harder. This is because the actual work a motor does consists of moving the 'mass' of air. The MORE air a blower moves the harder it works. Hence, restricting the air flow unloads the motor. This can very easily be shown by using a watt meter to monitor the power the motor uses with various filter restrictions.
    It can also be seen in the HVAC world by blowers having minimum flow ratings on their information plates. That's a rating that states that a minimum restriction is required. This is because less restriction than that would result in the blower motor being overloaded.
    As an additional example of this most people when using a vacuum cleaner and blocking the nozzle hear the vacuum get louder and speeding up. This leads to the almost universal belief that the vacuum motor is being 'worked harder'. In reality it's completely the opposite occurring. The vacuum motor is completely unloaded (not moving any mass) when the nozzle is blocked and the result is the completely unloaded motor simply speeding up.
    Your furnace motor not working hard is still a problem because it means the heat exchanger is likely being overheated since not a lot of air is carrying the heat out of the exchanger and into your home's air.

    • @ahhchu
      @ahhchu 4 ปีที่แล้ว +1

      Thanks for this explanation.

  • @Ryan-323
    @Ryan-323 3 หลายเดือนก่อน +3

    Love the video with real world information on why you should change your filter regularly.
    Like putting oil in your car!
    You can be lazy on a lot of preventive maintenance. Your filter should not be one of them.

  • @munozyoshi
    @munozyoshi 3 ปีที่แล้ว +5

    The plywood in the return blew my mind. Thanks for the video! Awesome demo.

  • @khashkhashak
    @khashkhashak 3 ปีที่แล้ว +6

    This is the best, and the most scientific, review on the internet

  • @omma-llama7860
    @omma-llama7860 5 ปีที่แล้ว +15

    Hi. I'm posting here on your most recent video to say "Thank You!" ... you see we had been told by a local contractor that out old r22 condenser was shot and our entire system needed to be replaced. I came across your videos while doing my own research, and after watching about four or five of your videos on outside units, I was able to go outside end for about $20 in parts get my old one working again. In my case, I had a bad 5 minute delay board. I much prefer to bypass the board then spend 6500 on a new system. I know it's coming in the future, but I'd like to get as much life out of this old system as I can. Thank you so very much.

    • @MrJeromegon
      @MrJeromegon 4 ปีที่แล้ว +2

      Old r22 systems lost efficiency with time. High Electricity Bill.So holding to one is asking for spending money in repairs no matter how many videos you watch. Newer 410 systems are much efficient and better on your light bill. Keep that in consideration.

    • @DS-fb9te
      @DS-fb9te 2 ปีที่แล้ว +1

      Star saving, is coming soon

  • @FA-44
    @FA-44 ปีที่แล้ว +3

    Nice video, thank you. I have the same furnace branded as a Trane and started out with 1 inch filters, but eventually converted to a 5 inch filter. Just as an FYI, the total static pressure across the entire furnace/AC coil system is specified not exceed .5 inches water column. Most manufactures will spec .5. My furnace came with a nylon mesh screen, but I always used the 1 inch filters from day one. When I started seeing the filters being sucked toward the blower motor as shown in your video, I realized my static pressures were very high just as you demonstrated. So I converted the furnace over to a 5 inch, Merv 16, charcoal impregnated filter (Merv 11 filters were also available in the 5 inch size). I found that I can actually leave the filter in for a full year. Here are the numbers that I recorded: on low heat fan, the brand new filter showed .20 inches, after a year, that rose to .24. On the AC blower speed, which would be higher, I started at .24 inches and rose to .28 inches one year later.

  • @jasonjorgensen9888
    @jasonjorgensen9888 4 ปีที่แล้ว +5

    Thank you! Ive been looking for this exact information for a long time! My tech had me set a google calendar reminder to change my filter every 2 weeks in the hottest part of summer and coldest part of winter to keep the house the most comfortable and the furnace happy. I also use the 3M 300 Basic, or equivalent. All the manufacturers should put their pressure drop numbers right on the packaging! New and used, like dump 1 cup of flour in front of it to simulate use.

  • @frankinsensed8058
    @frankinsensed8058 ปีที่แล้ว +1

    Great video! A plugged filter from the previous owner made my rooftop TRANE HVAC stop working (even after a new filter was installed). I fixed it by going on the roof, taking the covers off and vacuuming it out (in December when all the HVAC companies were busy). I got a pair of washable electrostatic filter now (wash monthly, switch filter to allow long drying time) and it works great! Jay is a great tech and teacher! Thanks!

  • @Level-333
    @Level-333 3 ปีที่แล้ว +37

    So this is confusing. The more expensive filters are supposed to be too restrictive. But, the filterite 600 had worse airflow than the expensive one. Yet, fiberglass let in too much debris. I’m very confused on what to buy.

    • @ZomBeatBrainZ
      @ZomBeatBrainZ 2 ปีที่แล้ว +10

      On the back of Filtrete filter it has flow rates. Merv 8 had less flow than all the other higher Merv filters.

    • @trippplefive
      @trippplefive ปีที่แล้ว +1

      @@ZomBeatBrainZ if they made a merv 8 with more pleats it would have better airflow

    • @Nick-Salv
      @Nick-Salv 2 หลายเดือนก่อน

      Same 😂 I feel like the answer is like most things, which is to find something right in the middle in terms of filtration and restriction, so that there’s both solid air flow but also blocking the air pollutants 🤷🏻‍♂️

    • @beammeupscottsp7952
      @beammeupscottsp7952 หลายเดือนก่อน

      @@Nick-Salv3m 1900 is the best, more airflow and filtrates more. Best of both worlds, you just need to be on top of changing them out more often

  • @henryt9254
    @henryt9254 3 ปีที่แล้ว +10

    The more pleats the filter has, the less restriction. Thats because there is more filtration area. That applies to old filters as well because the surface area is bigger. If you look at the 1900 vs the 300, there are more pleats on the 1900. So all things being equal the 1900 blocks more particles, but offset the restriction by having more filtration area. That's why they are more expensive, but the lag time for changing them does not require more frequent changes because of more filtration area.

    • @ebelray6890
      @ebelray6890 ปีที่แล้ว

      Thank you for this comment, as I replaced and FPR9 filter which was dirty, with and FPR7 and I could tell the A/C was struggling more which made no sense to me. Then I read your comment about the pleats. The FPR9 filter which was Honeywell had 28 visible pleats and the FPR7 filter which was generic brand only 23 pleats. I'm going to get a better brand now. You get what you pay for, lesson learned..

  • @SparkY0
    @SparkY0 3 ปีที่แล้ว +12

    More pleats mean more surface area. More surface area in the filter media means more space for air to flow through. So it makes sense that the more densely pleated filter has higher flow.

    • @jove1155
      @jove1155 ปีที่แล้ว

      Uh, no. The cross section area of air flow is the size of the filter.

  • @dvddmc
    @dvddmc 4 ปีที่แล้ว +6

    have been using the 1200 to 1500 filter changed every about every 2 months and have not been having any issues also wanted to note that have not been sick as much either and have pets as well so need that extra protection

  • @LouisWilen
    @LouisWilen ปีที่แล้ว +2

    Very helpful video. Nice to see someone quantitatively evaluate filters instead of just relying on manufacturers' claims and homeowner filter-lore.

  • @glasser2819
    @glasser2819 5 ปีที่แล้ว +11

    "furnace whistling" is from all the dirty air bypassing the filter... so a plitted 300 filter actually filter more because it keeps the bypass minimal yet still filter well unlike the see through green fibers.

  • @TonyWadkins
    @TonyWadkins 4 ปีที่แล้ว +6

    Thanks for your video. I believe you meant to say a dirty filter will lower the amps on a standard centrifugal PSC blower motor as it actually is working less hard. Now electronic ECM motors and their kind may work harder. However as you stated the system suffers due to less air moving across heat exchanger or coil causing high temps or icing.

  • @twodaend
    @twodaend 5 ปีที่แล้ว +6

    Thanks for this video. Perfect timing. I've been using the premium filters until this past cold spell of 2019. My furnace was constantly running but eventually the fan was just going with no heat coming out of the vents. Turns out the filter was caved in. I've replace with a more middle of the road filter and will see how it works out.

    • @thegr8rambino
      @thegr8rambino 2 ปีที่แล้ว

      How’d it work out bro?

    • @twodaend
      @twodaend 2 ปีที่แล้ว +1

      @@thegr8rambino I've switched to just the basic blue filters, similar to the green ones shown in the video. I noticed that even with the middle of the road filters, they still clogged in a pretty short time. When I changed them, they were caved in just like his. The only difference now is that I change the cheaper ones much more often considering they are pretty cheap. I did not change the others ones as often because they were more expensive and they were "supposed" to last longer without getting clogged. That wasn't the case for me.

  • @billybbob18
    @billybbob18 5 ปีที่แล้ว +2

    I smacked a failing gas valve once and as far as I know, the thing is still working. The pressure switch is also a great component to "snack into operation". I explained the reasoning for the Fonzorelli treatment and told them I smacked it in a way that would make it last a while longer. They opted to leave the same valve in and pay my hourly rate. They needed heat and I gave it to them instantly without warranty. Most people have me go ahead and order them a new replacement, but if it's someone just trying to sell a house....

    • @WordofAdviceTV
      @WordofAdviceTV  5 ปีที่แล้ว +1

      The smacking treatment does prove very effective at times! :) I've had it work many times for me before. A stuck fan relay on a control board can be fixed that way too heh. Thank you for sharing!

  • @OleGimletEye
    @OleGimletEye 4 ปีที่แล้ว +6

    I’d like to point out that the unit motor does not over-work as you mentioned with a dirty filter in fact the more the filter is clogged the less the motor works. This can be easily checked by amperage draw of motor which is another way of checking for a dirty filter that has to be replaced. I do like your videos 👍

    • @mikelewis4260
      @mikelewis4260 4 ปีที่แล้ว +1

      Do you check the blower motor with the door closed or open? If open then off course it will run lower.

  • @williamsumrall333
    @williamsumrall333 4 ปีที่แล้ว +4

    I enjoy all your videos - very informative. As a side note, I have used a fiberglass filter (the same one) for 45 years in Texas. I usually wash it twice per season. Never had ‘A’ coil checked. When first turn on a/c in spring, aim infra-red thermometer at vent to check if temperature same as previous year. Most recent A/C at least 6 yrs old. Knock on wood :-)

  • @irishsausage6
    @irishsausage6 2 ปีที่แล้ว +4

    This was such an informative video on understanding filters. I have struggled with finding the best filters to keep the efficiency high but our air "cleaner" since we also have 2 cats... we can also fit the wider filters in our system which are supposed to have better airflow so I would love to see how 4" vs 1" compare right off the bat but also just how long they last since the cost is significantly higher and after seeing this I feel like those should still be switched every 2-3 months, not the 6+ like they may advertise. I also just replaced a filter that I thought was clean but in fact looked like your dirty white one when I compared it to a fresh filter. At least I know that means these are in fact filtering out particles.

  • @kevinminner9090
    @kevinminner9090 4 ปีที่แล้ว +13

    The white dust on your filter can be caused by an "ultrasonic" humidifier, it's most likely minerals(calcium) in your water. You may try moving the humidifier further from a return, or try using distilled water. Informative video. Thanks

  • @richpeterson3646
    @richpeterson3646 16 วันที่ผ่านมา +2

    I just changed my furnace filter. Thanks for the reminder.

  • @Ryan-323
    @Ryan-323 3 หลายเดือนก่อน +2

    I have a very similar furnace in my house and I do run the high end. I think it was 1800 filtrate model and I do have to change my filters about every 4 to 6 weeks. They start off white and they come out to Grey. I have a dog. If you start to see your filter, bow change it you’re hurting your compressor or your fan blower. Great way to cause a coolant leak and if you have an old filter like mine are R22 is rare and expensive.
    Just ask my neighbor, who forgot to change her filter for two years her bill all I have to say ouch.

  • @HomieG-fl9wk
    @HomieG-fl9wk 9 หลายเดือนก่อน +2

    I keep coming back to this video since getting a pressure meter. I started weekly measurements to get a graph going on how often it reaches my set threshold before changing it.

    • @shaolin95
      @shaolin95 3 หลายเดือนก่อน

      Which one did you get?

  • @chodkowski01
    @chodkowski01 ปีที่แล้ว +2

    I use the $1 merv filter and change out every month and clean my A frame every year. My 25 year old Trane blows strong and still has the original parts. Engineers designed my unit with a merv 1. I’ve been quoted $5,700+ to replace my A/C but as long as it does it’s job I’m fine. I’m hoping to get 30 years from my A/C.

  • @GilmerJohn
    @GilmerJohn 4 ปีที่แล้ว +6

    Gad! THE reason for the pleats is to increase the effective filter area. That's why an effective filter doesn't necessarily have a hugh pressure drop.

  • @dcairns61
    @dcairns61 3 ปีที่แล้ว +4

    I put a GeneralAire G99 air filter gage on my unit and it gives a visual indication of the air pressure difference so you can know when to change the filter. This saves having to open up and visually check the filter. Although not as cool as the manometer used in the video, it is cheap.

  • @fredmotschman6050
    @fredmotschman6050 5 ปีที่แล้ว +4

    Hi J
    Thumbs up for your video content. When using inexpensive filters as I do spray intake side of filter with hair spray it increases the amount of dust particles , dander and crap the filter catches.
    You’re videos rock

    • @WordofAdviceTV
      @WordofAdviceTV  5 ปีที่แล้ว +1

      Thank you for the great suggestion Fred! Glad to hear you like the videos!

  • @jimhoelle4013
    @jimhoelle4013 4 ปีที่แล้ว +5

    Nice video. I'm thinking the pressure drop is a function of both the MPR rating and the filter surface area. Since the filters increase in pleats as they increase in MPR, it could explain the lower pressure drop with the 1200 and 1900. That said, it seems like a filter having both an MPR of 300 and a lot of pleats would really be good.

  • @AlexK-ew1mo
    @AlexK-ew1mo ปีที่แล้ว +2

    You drilled holes into your unit for us. That's dedication

  • @VIDSTORAGE
    @VIDSTORAGE 3 หลายเดือนก่อน +3

    I use to buy the expensive filers and found out most were awful because of restriction and the Flanders EZ Flow will catch dust very efficiently and gets better as it catches more dust

  • @averypitts7621
    @averypitts7621 3 ปีที่แล้ว +5

    Best air filter video i ever seen.good job.

  • @njhbgy98
    @njhbgy98 3 ปีที่แล้ว +13

    AWSOME video. Did you know K&N Car Air Filter maker made a washable HVAC MERV 11 filter too? I just found out. I was wondering if you could do a comparison test as brand new vs. after 3 months of use & after it has been washed. To see if the air flow has dramatically changed. What do you think?👍

  • @d.j.robinson9424
    @d.j.robinson9424 3 ปีที่แล้ว +3

    I always told homeowners to shut off the system when vacuuming. Also used 3M spray adhesive on the cheap fiberglass filters...👍👍💚

    • @stellaherrick7462
      @stellaherrick7462 3 ปีที่แล้ว +2

      did you look to see what was in the 3M adhesive - one is a carcinogen.

    • @d.j.robinson9424
      @d.j.robinson9424 3 ปีที่แล้ว +1

      @@stellaherrick7462 no, I didn't realize that. Thanks for the information 👍👍

    • @richardlapera77
      @richardlapera77 3 ปีที่แล้ว

      Good vacuums have hepa filters and should create very little dust. Also, let the furnace clean what does arise vs letting it settle in the rooms.

  • @sharondjmj
    @sharondjmj 4 ปีที่แล้ว +1

    it's getting coldrer in CA, so checking out the filter thing. This is my first year to take care my 1 year old furnace. so glad that I bought the right cheap filter, and I will change them often if I use it everyday.

  • @TheRealoldcar
    @TheRealoldcar 4 ปีที่แล้ว +2

    The 3m 1900 rating starts out at the Lowest static drop at its highest rated CFM than their lower or higher rate MPR models. And since it will have a high dirt capture rate , the static drop will increase fast depending on the interior condition such as carpet, pets, etc. As I tell my customers in Northern California area, they have a choice, if they want better cleaning of their circulated air, use the higher MPR (Merv) rated filters, but do understand that it will need to be changed about once a month, and in many cases the blower motor will be running slightly harder and may draw slightly more power. The plus is that the insides of the furnace will stay cleaner or not get as dirty as fast as using the basic fiberglass filter. I left out a lot of details , but my home system return air supply is oversized so that it can use the 2800 or higher 3 M Filtrete filter mainly to keep the furnace and supply ducting as clean as possible for as long as possible so me being as lazy as I am don't have to work so hard cleaning the ducting and furnace especially the blower wheel because the furnace is in the attic and I am not as slim as I was in my younger days. With all the recent California fires, nearly all my customers have requested the highest rate MPR models that are available for their systems, the feedback has been that they do notice an inside air improvement, albeit subjective of course.

    • @Zebra_3
      @Zebra_3 2 ปีที่แล้ว +1

      having a clean house helps...also no candles, smoking, and keep your filthy animals in the barn.

  • @delc9876
    @delc9876 4 ปีที่แล้ว +3

    Filtrete makes a 2800 filter. When using higher rated filters, they have to be changed more frequently. Using PuraClean filter spray can enhance a filters' ability to capture dust as it apparently is a tacifier and imparts a static charge.

  • @mikestevens3023
    @mikestevens3023 2 ปีที่แล้ว +5

    Project Farm did a similar video. His results suggested that higher mpr/merv filters static pressure was higher initially but did not increase as much for a given load of dirt. The reason being that more pleats means more surface area which means less debris were square inch. Someone needs to do more definitive testing testing. In the meantime, it seems clear furnace filters are like engine oil.... change them frequently...dont wait 60-90 days!

    • @marcsmith3881
      @marcsmith3881 2 ปีที่แล้ว +1

      I agree 100% I have a house full of allergy sufferers, including myself so I can live with the little restriction, much cleaner air. Dust is not welcomed in my house, I change them every month like you mentioned.

  • @tracyavent-costanza346
    @tracyavent-costanza346 4 ปีที่แล้ว +5

    this is the way that science should be done. great job. the drama is in the numbers.

    • @WordofAdviceTV
      @WordofAdviceTV  4 ปีที่แล้ว +1

      Thank you! Glad you liked the video :)

  • @publicmail2
    @publicmail2 5 ปีที่แล้ว +3

    I use a honeywell F50 HV air cleaner it has a SP of .1 at 1500 CFM 3 ton and never gets worse then that even when cells need to be cleaned in dishwasher. If you don't use that type get a filter housing for a 4 inch pleated. High static pressure will cost you money big time especially on AC.

  • @AutoAddiction
    @AutoAddiction 4 ปีที่แล้ว +2

    Another great video! I hope you're loving Hawaii, just saw your latest update. I just replaced my blower motor and serviced my AC system using your channel! Thanks a ton.

  • @tedkobel5002
    @tedkobel5002 4 ปีที่แล้ว +16

    I was very interested to see results, however right up front I noticed you placed the static pressure tubes incorrectly. Look like you have them pointed down. That puts the holes in the tube normal to the flow which means you're reading total pressure not static pressure. For static pressure you should place the probes parallel to flow. The difference will be that the total pressure includes the velocity pressure component which will vary depending on pressure drop. That throws off your results. Otherwise it would have been a great test. Hope you try it again sometime with the correct orientation of the tubes.

    • @AmbachtAle
      @AmbachtAle 3 ปีที่แล้ว +4

      In this case it probably doesn't make much difference since he is measuring where there are turns and the air is not laminar.

  • @qqqqcccc5937
    @qqqqcccc5937 ปีที่แล้ว +1

    Was having heating issues, followed your recommendation, removed the filter and...problem solved! Using a less restrictive filter...Thank you!

  • @3xt1Collatz
    @3xt1Collatz 4 ปีที่แล้ว +5

    I’m glad I bought the MPR 1900

  • @coffeeabuse
    @coffeeabuse 2 ปีที่แล้ว +3

    1:13 The 1500 filter you tested is 16X24X1. The rest are 16X25X1. So you could have had leaks on that one filter. Haven't checked the rest of the comments to see if anyone else noticed that...

  • @classic287
    @classic287 5 ปีที่แล้ว +4

    I switched to the green filters years ago. The house cools faster and I save on electricity. I like your videos. You’re helping me maintain my own a/c, because you can get ripped off real bad
    down here in Florida...

    • @WordofAdviceTV
      @WordofAdviceTV  5 ปีที่แล้ว +1

      Glad I could help! Stay cool! :) Looks like you went through quite a few of my videos. Thanks for watching! ;)

    • @MRrwmac
      @MRrwmac 5 ปีที่แล้ว +3

      classic287 Please explain green filters? Do you mean the fiberglass ones like the one he demonstrated? Thank you.

  • @chabirajpersaud3001
    @chabirajpersaud3001 2 ปีที่แล้ว +2

    this was such an informational video man.... do keep up the good work

  • @MrMarcus5191
    @MrMarcus5191 3 ปีที่แล้ว +4

    Here's a cheat that really works...have done this for many years...I use cheap fiberglass hardware store filters, the kind in a 3 pack for $5.....I lightly spray them with WD-40 then lay them out in the sun to let the solvent evaporate and odor to dissipate. They collect much more dust so I change them frequently but the furnace fan, motor and aircon evaporator coil remain spotless.

    • @Drew-bv9rc
      @Drew-bv9rc 3 ปีที่แล้ว

      What does the wd40 actually do, if you don't mind me asking

    • @MrMarcus5191
      @MrMarcus5191 3 ปีที่แล้ว

      @@Drew-bv9rc The WD40 remains slightly sticky and captures more dust..I change the filters monthly...

    • @countryfella94
      @countryfella94 2 ปีที่แล้ว +1

      @@Drew-bv9rc it’s the same idea of oiling a filter on a motorcycle or lawnmower

    • @kurt5490
      @kurt5490 2 ปีที่แล้ว

      I used to work on a crew that cut rumble strips. The asphalt dust would plug up the radiators of all the equipment in about a month. So used polyester pillow fill to cover the radiators and spray them with aerosol spray starch. Worked great. You could even reverse the matting to use both sides. Spray starch is preferred because any that got on the radiator would cook off and not build up.
      WD-40 is a good idea!

  • @ethanletzer3507
    @ethanletzer3507 3 ปีที่แล้ว +7

    Thank you for the great info!! Please do testing on higher MERV rating filters. MERV 12-16 would be amazing!

    • @themikeroberts
      @themikeroberts ปีที่แล้ว

      The MPR 1900 he tested here has a MERV 13 rating according the manufacturer, 3M/Filtrete, and there's no need for a higher MERV rating as that's already basically HEPA quality.

    • @ethanletzer3507
      @ethanletzer3507 ปีที่แล้ว

      @@themikeroberts Well considering a HEPA filter has a minimum MERV 17 rating I would have to disagree on all points. There is always a reason to use a specific rated filter but that also comes with other issues which is why I made my original comment.

  • @65stanger1
    @65stanger1 2 ปีที่แล้ว +3

    I am curious what you think about the washable stuff out there. K and N now has a home air filter that they state is MERV 11 and is washable. They make not mention of the static drop but do brag about the flow rate. Great video as usual!

  • @GPstar87
    @GPstar87 4 ปีที่แล้ว +8

    This is excellent information and exactly the type of video I was looking for. Thanks for the work you put into this!

  • @sptrader6316
    @sptrader6316 3 ปีที่แล้ว +1

    We have to have a combination of free flowing and still have effective cleaning, seems to be a balance of the two that is needed. The better the cleaning, the more restrictive the filter. I use a Merv 3 pleated and it seems ok, in my dusty climate. I may try a fiberglass next time, I didn't know that they were so much less restrictive. I really enjoyed the test.

  • @1987019870
    @1987019870 5 ปีที่แล้ว +6

    I really had little idea about how restrictive filters could get when you compared them to your plywood. Thanks!!

    • @WordofAdviceTV
      @WordofAdviceTV  5 ปีที่แล้ว +4

      Glad I could show you something interesting :)

  • @dougstearns6746
    @dougstearns6746 2 ปีที่แล้ว +1

    Two thumbs up as always. You are the most helpful on you tube for HVAC. Thank you!

  • @rzh3443
    @rzh3443 6 หลายเดือนก่อน +1

    Interesting! Just saw this on the YT “reading list”. The installers push those “ thick” filters when they try to upsell. I said fine, but show me that you can keep below the max static pressure spec for the furnace and for how long. That shut them up. I use the Filtrete 1085 s, or equivalents, and change them out every six weeks. My A coil is clean after 8 years. The filter manufacturers don’t make it easy to compare efficiency though. Everybody has a different system and , I suspect , different processes to cost the pleats.

  • @originalradman9491
    @originalradman9491 4 ปีที่แล้ว +2

    Thank you very much for this video. I'm planning to run the premium filters anyways - but I will ensure that I just change them more often! Furthermore - I might even invest in a manometer to check on the actual health of the filter I'm using. I'm also using the 5" thick filters - and hoping they don't cause as much resistance overall. Wish me luck!

  • @sergiotorres583
    @sergiotorres583 4 ปีที่แล้ว +6

    I would like to see how one of those k&n home air filter do, see how restricted those are.

  • @stevewarren3051
    @stevewarren3051 5 ปีที่แล้ว +9

    It would be interesting to see a vid that proves your theory that a clogged high efficiency filter restricts more than a low efficiency one.

    • @WordofAdviceTV
      @WordofAdviceTV  5 ปีที่แล้ว +3

      Yeah.. Sorry, I didn't have an example of a very dirty premium filter. I wish I would have kept some of those extreme examples from previous jobs. It would have been interesting to see how big or small the pressure difference would have really been.

  • @HamHamHampster
    @HamHamHampster 2 ปีที่แล้ว +2

    Thanks. I have pretty severe allergies so I needed something with a high rating, but was worry about airflow. I will give 1900 a try.
    3M said they can last 3 months but I am not sure if it can last that long.

  • @brianklein6387
    @brianklein6387 5 ปีที่แล้ว +2

    I had an a/c company fix mine it ran great & next day I put in some super thick high $ filter & later that day it froze & got hot air he came back put in his filters & let everything thaw & it's been working great for 2 years

    • @KeithsTVHD1
      @KeithsTVHD1 3 ปีที่แล้ว

      What kind of filter did he put in?

  • @jesserobledo3439
    @jesserobledo3439 5 ปีที่แล้ว +3

    Best video ever perfectly explained you helped my save my ac unit and money thank you i learned a lot

    • @WordofAdviceTV
      @WordofAdviceTV  5 ปีที่แล้ว +1

      @Jesse Robledo You're welcome! Thank you for watching!

  • @alexl3383
    @alexl3383 4 ปีที่แล้ว +16

    Can you test the new k&n air filters

    • @ruz6135
      @ruz6135 4 ปีที่แล้ว

      I was super bummed that wasn't on there.

    • @jshapiro34
      @jshapiro34 4 ปีที่แล้ว +3

      Test the k&n and also run the 1200 and 1900 for 31 days and check it's flow rate......if it's not killing the hvac even at 31 days they are well worth the money

  • @krazyangel917
    @krazyangel917 4 ปีที่แล้ว +3

    NaturalAire is a good brand from American Air Filters (AAF Flanders) for pleated. This is the same manufacturer who makes the EZ Flow Fiberglass one in this video.

  • @Spinonemaster
    @Spinonemaster 4 ปีที่แล้ว +1

    I just installed a new F/A system and all new ducting/flex, etc ... and ran it a few seconds a few times without a filter to make sure my intake/output was balanced .... having 2 big hairy dogs I installed Merv2 (green glass) at the returns to catch the big stuff (sprayed with filter charger) and then a Merv 6 at the furnace ... it worked well, good flow/balance .... (and I'm a fanatic about changing filters once a month to keep unit from working too hard, buy in bulk from amazon, cheap insurance in my book as an experienced builder) ..... I accidentally ordered 6 Merv 11's mid heating season ... and noticed immediately the air flow was restricted, and really restricted in a short time 2 weeks or so .... so it's always a balancing act ..... too bad manufactures don't test and put the new filter differential number on their products .... although I do have a Manometer and probes to test as you did here .... anyway, very informative, i always learn, or relearn things when I watch one of your video's ... good info without loosing the DYI person by getting to mysterious or technical .... I have another tip if you buy in bulk packages, besides using a spray on charger (available on amazon) store your filters in a warm/dry place ... I'm in eastern PA right on the Delaware in a 150 year old house .... dampness and mold are always a problem here .... bulk filters without plastic wrap in a cardboard box got moldy quickly ... so I store upstairs in a big contractors box to keep them clean and mold free .... late Aug, and I tossed the last few Merv 11's so need to reorder some Merv 6's on amazon when I get off here .... thanks for the vid, I've been subbed for a while

  • @scottwebber652
    @scottwebber652 3 ปีที่แล้ว +2

    I have a4” filter space but 20$ a pop had to find a cheep alternative. I went back to the 1” fg butusefour n apply furniture polish to the lead filter. I alternate them n only toss the front one periodically much easier on my wallet n works great !!

  • @rw3880
    @rw3880 5 ปีที่แล้ว +11

    Love the plywood fliter, sending this video to friends in the field. Will you do a video on how to size a furnace or an A.C.!

    • @WordofAdviceTV
      @WordofAdviceTV  5 ปีที่แล้ว +5

      Glad you liked it, thank you! About the sizing.. Thank you for the video suggestion but I have never been an installer, I only do service. So I don't think I would be a good candidate to make a video like that.

  • @fredbloggs6080
    @fredbloggs6080 3 ปีที่แล้ว +1

    I have owned my current house for 11 years, and a good-quality Trane air conditioner was put in two years before I moved in. I have almost always used the Filtrete 1900, except for a few years after Home Depot stopped carrying them and switched to Honeywell, of which I used the MERV 13 Premium version, that were not any cheaper than the Filtrete 1900. I don't know if they were as effective, but they had much wider pleats and were much flimsier, and would bow inwards under the negative pressure of the air conditioning unit, although the frame still provided a seal. When I discovered the Filtrete were being sold on Amazon I resumed using the 1900 version in 2017. At first in this house, I would change them after a month, as recommended by the air conditioning service people, but then I went to a month and a half, then two months, and for the last year or two have been leaving them in for three months. After three months they do get a light gray color (I accidentally left one in for close to six months one time when I was having eye problems). I can't tell if it is putting a strain on the air conditioning unit or not, but I never had to service the motor, and never had to clean the coils and this air conditioner was unit was installed in 2007. When I moved in I had the air ducts enlaged, especially to the front bedroom/office and had another vent put in that room near the original one, as it wasn't getting as cool as the other rooms. (This current air conditioner is also a larger size unit than it replaced, before I moved in, I believe). But I don't burn candles or even grill things in the kitchen--I had a cat in the house for the first six years but that didn't seem to affect the filters much--I don't have rugs. I noticed that dust does still accumulate in the living and dining room areas and the kitchen and actual bedroom, but hardly at all, comparatively, in two other rooms, the front bedroom set up as an office but not used much, and the small middle bedroom, which is used as a library, where the door is kept shut for the library and almost shut except for about 2 inches, for the front bedroom/office which is at the end of a short hallway. So unless the extra dust comes in during the brief times the front and back doors are open I'm not sure why it is dustier in the living areas, with just one person in the house, unless it comes from a couch or more leaking of air from of the windows or sliding glass doors in those areas.
    PS I just reordered six of the Filtrete 1900 filters from Amazon, but I didn't discover until they were delivered in a day or two, but somehow the item was switched in my cart when I placed the order to the wrong size, so I have to return them for refund, and the correct size says it will ship in 1 to 2 months. Looking at the 3M website it says no distributor available at this time. I wonder if they are short supply because they had to repurpose the 1900 spec material for respirators a year ago.

    • @chevelleflorida
      @chevelleflorida 2 ปีที่แล้ว

      I just saw the no distributor available at this time on their website but the 1900 is available at Lowes. Currently, if you buy 4+, they are $14.38 each. Glad to hear that you've had a good experience with them.

    • @fredbloggs6080
      @fredbloggs6080 2 ปีที่แล้ว

      @@chevelleflorida Oh, I thought you meant it was not available on Amazon, you meant the Home Depot. Although I have four filters left and one in use with a couple months remaining, I ordered six more from Amazon in case they becomes scarce. The dimensions of mine are probably not as common as some other sizes. They are something like $116 for 6, $110 if you subscribe for delivery, on Amazon. I looked on the Lowe's website and they do not have the 1900 or anything about 1500 MERV in my size filter.

  • @caseyward4092
    @caseyward4092 4 ปีที่แล้ว +2

    I live in South Florida, I change my 3 month filters every 2 weeks!

    • @stellaherrick7462
      @stellaherrick7462 3 ปีที่แล้ว

      I live in the Tampa Bay area and replace the filters every 2 weeks on the beach.

  • @michaeld.9890
    @michaeld.9890 3 ปีที่แล้ว +1

    Great demonstration! Thank you for your all your time. I’ll be buying different filters as my “new” home with new filters is struggling after about 3 weeks with only 1 cat. I have the 3M 1200 filter

  • @shaneehurd7342
    @shaneehurd7342 ปีที่แล้ว +2

    Very educational video.
    Thank you for clear, understanding explanations.

  • @pfitz4881
    @pfitz4881 ปีที่แล้ว +1

    Great job providing readings on various filters!!! BUT.. There is absolutely no way a dirty filter is worse than plywood. It amazes me the wild false clams that are made by TH-camrs.

  • @wildburpp
    @wildburpp 4 ปีที่แล้ว +5

    Good video.. I use the 1500 for allergies. I want to convert from 1in to 4in. Filters.

  • @Dcc357
    @Dcc357 4 ปีที่แล้ว +2

    I had an electrostatic filter for forever and never realized how much it blocks flow. I switched to a Merv 11 by 3M and I can just hear the difference in noise alone. Feeling more airflow from all vents too.

    • @reck0n3r
      @reck0n3r ปีที่แล้ว

      That's weird because electrostatic filters tend to have MERV 8 or less. How often were you cleaning your electrostatic? My minimal understanding is that they should be cleaned once a month.
      Appreciate the comment though. We just picked up an electrostatic filter and I'll probably have it in within a couple months.

  • @tylermack954
    @tylermack954 3 ปีที่แล้ว +3

    Awesome video! Love all the info. I guess expensive isn't always better. IDK what the FPM rating is but the only one home depot sells in my size Rheam cheap pleated filter 3 for $10 seams to be the way to go!

  • @joa8593
    @joa8593 ปีที่แล้ว +1

    Increasing pleats both increases airflow *and* filtration (because face velocity is lower the shaper the angle of the pleat). This is why the high rating filters sometimes rate better than the next step down.
    Some manufacturers just use more restrictive material though. It's very important to use one by a legit manufacturer like 3M or Honeywell.
    Also, a clogged filter of any rating will eventually get to 1+. More pleats will last longer, but they filter smaller particles so for the same filter media the higher filtration one should last longer (i.e
    600 last longer than 300, 1900 longer than 1500)

  • @PanicDontPanic
    @PanicDontPanic 4 ปีที่แล้ว +10

    Thanks for this. I would love to see these tests done with the Nordic Pure filters, as they seem to be affordable but I'm worried about the pressure drop in my HVAC system.

    • @MS-st1zb
      @MS-st1zb 3 ปีที่แล้ว +1

      I just went through that, weird. The new restrictive filter, restricted too much, the flow was not right, it was like it would build up pressure in the ducts and when the house and ducts leveled off the duct would make a pop sound, pressure is not right. I can do a paper towel test near the intake with the new filters and barely hangs on to the vent, hardly a sound, new nonrestrictive filter ( old type), works perfect. They tell us through the years clean your filter to save, these new filters clean are worse than any dirty filter I have ever have, am I saving money with the new very expensive filters, what are you doing to my equipment?.

  • @smacleod69
    @smacleod69 3 ปีที่แล้ว +3

    On your manometer The readinf should be "INWC" not "INWG". Unless UEI and Fieldpiece are labeled differently

  • @seanefrem9226
    @seanefrem9226 2 ปีที่แล้ว +2

    Use up to 4 to 7 and use the cheap one on really hot days

  • @dannypoorboy906
    @dannypoorboy906 2 ปีที่แล้ว +1

    Thanks for the info . It is like do you want to heat the house or clean the air you can't do both . I heat the house with the open filter . Then clean the air with air cleaner machines.

  • @dontderockmeriz4546
    @dontderockmeriz4546 4 ปีที่แล้ว +7

    I just use the cheap fiberglass ones. They do just fine imo.

  • @Ryan-yi6su
    @Ryan-yi6su 3 ปีที่แล้ว +4

    If you have matching filters I would suggest weight them both in seeing what the difference is.
    If you only have 1 lb difference or less and it becomes very restrictive versus a 5-in pleated with 1 lb and it's less restrictive than we know that the 5-in is the better value, and won't make your motor work as hard

  • @guberandhayalan3510
    @guberandhayalan3510 4 ปีที่แล้ว +6

    Informative. Great Job on explaining it nice and clear. I am going to settle with 300 MPR.

    • @WordofAdviceTV
      @WordofAdviceTV  4 ปีที่แล้ว +4

      That's all I use and never have problems :) Thank you for watching and leaving a comment!

    • @bunnybubs757
      @bunnybubs757 3 ปีที่แล้ว

      What is a 300? Mine says 4 , 7 etc

    • @bunnybubs757
      @bunnybubs757 3 ปีที่แล้ว

      What is the merv? I see 7 … no number 300 etc

  • @soaredwood162
    @soaredwood162 ปีที่แล้ว +1

    This video should be getting millions of views, but people are more interested in watching crap from millionaires who don’t give a rats a$$ about them.
    Great video! Very educational and informative!

  • @geeznogoodname
    @geeznogoodname 3 ปีที่แล้ว +3

    Thank you for the great information and a well done video on furnace filters! Maybe you can do an update and include washable filters. Although they are not for me (too much trouble cleaning them), I have friends who swear by them. Again thank you!

  • @stuuuporman
    @stuuuporman 2 ปีที่แล้ว +1

    Not only do many pleats usually filter out more stuff (Depending on the filter material), they also last longer. 10' of material vs 30' over the same time.

  • @creamofbotulismsoup9900
    @creamofbotulismsoup9900 ปีที่แล้ว

    We use the 3M 2200 filters from Costco, usually pick up a 3 pack or 2 when they go on sale so they end up costing around 12 bucks each. The pleats are very dense, so they shouldn't be that restrictive when they're new similar to that 1900 filter. Just change them out when I hear them start to whistle, roughly 1-3 months depending on how much the HVAC system is being used.
    One benefit of use a high MERV filter is that the evaporator fins of the AC system stay cleaner and require cleaning less often. Though I am thinking of transitioning to a less restrictive filter for the HVAC and using a secondary filter system that runs 24/7 to keep the air in the house cleaner. Probably something like a Corsi Rosenthal box because I'm a bit of a cheapskate.

  • @theanswer1221
    @theanswer1221 3 ปีที่แล้ว +6

    Hey what are your thoughts on electronic air cleaners? Thanks in advance i love your videos

  • @bart1meuz
    @bart1meuz 5 ปีที่แล้ว +7

    Paper filters are all merv 3 which is trash. People forget to change them out monthly and they end up getting sucked into the blower motor. Kills the motor. Do yourself a favor and get a electrostatic filter which are merv 11. Or even better get an Aprilaire filter installed.

  • @Bowhunters6go8xz6x
    @Bowhunters6go8xz6x 8 หลายเดือนก่อน +1

    Great Tests, would have been interesting to see if the fan motor got hot with restricted air flow. Wouldn't be great for the motor though. LOL Thanks. Informative.

    • @WordofAdviceTV
      @WordofAdviceTV  8 หลายเดือนก่อน +1

      That's a good point! I didn't think to measure the temperature of the motor. Maybe in another future video. 🙂

  • @victorstandiford9724
    @victorstandiford9724 หลายเดือนก่อน

    Between the 600 and 1200 filters, you are witnessing filter construction coming to bear. The pleats on the 600 are allowed to flop over, in other words, they are not braced like the 1200 filters. ( notice the difference in filter construction). The 1200 is supported and held in place more rigidly. This creates a noticeable difference in airflow..